N843AA, cancelled Feb 4, 2002
Service difficulty reports · 35
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N843AA' AND deregistration_id = 'N843AA-2002-02-04' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N843AA' AND deregistration_id = 'N843AA-2002-02-04' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20011828Battery Pack · dischargedDTW - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010367Terminal · disconnectedDFW - DURING OVERNIGHT MAINTENANCE, AFT AIRSTAIRS EMERGENCY EXIT LIGHT DIM. RE-SECURED AFT AIRSTAIRS EMERGENCY EXIT END TERMINAL LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010326Shear Tie · corrodedTUL - FOUND CORROSION BETWEEN BELL FRAME AND SHEART TIE STATION 720A STRINGER 28L-27R. CUT OFF SHEAR TIE FLANGE INSTALLED SHEAR TIE FLANGE PER SRM 53-10-04. (M)SDR AALA20010327Strap · corrodedTUL - FOUND HEAVY FRAME SPLICE STRAP ON UNDERSIDE OF FRAME CORRODED AT TWO NUT PLATE ATTACH POINTS STATION 616, LOWER AFT CORNER OF DOOR OPENING. REPLAED TAPERED STRAP AS PER SRM 51-10-1. (M)SDR AALA20010167Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AFT AIRSTAIR INOPERATIVE. RE-SECURED EMERGENCY EXIT LIGHT ASSEMBLY AT AFT AIRSTAIR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20001578Socket · dirtyMIA DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTS ABOVE ENTRY DOOR INOPERATIVE. CLEANED EMERGENCY EXIT LIGHT ASSEMBLY LAMP BASE AND SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20000153Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT LOWER SIDEWALL INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY FOR LOWER SIDEWALL. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20000152Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT OVER AFT AIRSTAIRS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY OVER AFT AIRSTAIRS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA2000102Web · crackedTUL - LEFT LOWER TORQUE BOX VERTICAL WEB CRACKED AT LIGHTENING HOLE. INSTALLED TYPICAL WEB REPAIR PER SRM 51-40-2. (M)SDR AALA200097Stringer · crackedFOUND STRINGER 18A RIGHT SIDE CRACKED AT STATION 940 FITTING AND SKIN CRACKED AT BOTTOM FORWARD HOLE, STATION 950. REPAIRED PER ESO 11697 DATED 1-13-00, SB727-53-172 AND REPAIR DRAWING 65C29069. (M)SDR AALA2000100Skin · dentedTUL - FOUND SKIN DENTED AND GOUGED STATION 1173 ABOVE STRINGER 24R. INSTALLED DOUBLER IAW SRM 53-30-3. (M)SDR AALA200099Shear Tie · corrodedTUL - FUSELAGE SKIN BULGED JUST ABOVE LAP SPLICE STRINGER 26R AT STATION 520, 2 INCH BY 3 INCH AREA, FOUND SHEAR TIE WITH CORROSION. NO CORROSION ON SKIN. INSTALLED NEW SHEAR TIE PER SRM PER SRM 51-20-1 PAGE 4. (M)SDR AALA2000101Skin · gougedTUL - DEEP GOUGE AND DENT IN LEFT AFT L-2 DOOR SKIN, AT UPPER FORWARD CORNER STATION 1045. INSTALLED EXTERNAL REPAIR TO LEFT AFT L-2 DOOR PER SRM 52-00-3 FIG 3. (M)SDR AALA991386Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS WERE INOPERATIVE. REPLACED CONNECTOR TO EMERGENCY FLOOR PATH LIGHTING. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA991334Valve · defectiveDFW - FLT 0092 - AFTER TAKEOFF DFW/EWR, CREW WAS UNABLE TO CONTROL PRESSURIZATION. AIRCRAFT RETURNED TO DFW, DUMPED FUEL, AND LANDED WITHOUT INCIDENT. REPLACED NR 3 ENGINE 13TH STAGE MODULATING VALVE. ACCOMPLISHED CHECK OF BLEED AND PRESSURIZATION SYSTEM. SDR AALA991192Light · defectiveTUL - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT SIDE MARKER LIGHT BY FORWARD SERVICE DOOR LOOSE FROM WALL. REPLACED EMERGENCY EXIT SIDE MARKER LIGHT BY FORWARD SERVICE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA991126Light · defectiveDFW - DURNG OVERNIGHT MAINTENANCE, AFT STAIRWELL EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AFT STAIRWELL EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA990334Wire · defectiveDFW - DURING MAINTENANCE CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS IN COACH CABIN INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH FLAT JUMPER WIRE AT SEAT ROW 16. SYSTEM GRUOND CHECKED NORMAL OPERATION. (M)SDR AALA990094Stringer · corrodedTUL - STRINGER 26 LEFT INBOARD LEG CORRODED UNDER FLANGE STATION 560. INSTALLED STRINGER SPLICE PER SRM 53-10-3, (M)SDR AALA990091Frame · damagedTUL - INSTALLED DOUBLER PER SRM 51-40-3, DOUBLER .071 7075 T-6, INSTALLED WITH 3 ROW OF 12 EACH .1875 HI-LOCKS. (M)SDR AALA990093Stringer · corrodedTUL - FOUND CORROSION ON STRINGER 27 LEFT AT STATION 527. INSTALLED STRINGER REPAIR AT STRINGER 27 LT STATION 527 PER SRM 53-10-3. (M)SDR AALA990092Stringer · corrodedTUL - FOUND STRINGER 28R CORRODED. DRILLED NEW PRODUCTION SPLICE. INSTALLED PER SRM 51-10-1. (M)SDR AALA981085Sensor · defectiveDFW - FLT 1503 - AFTER TAKEOFF EWR EN ROUTE DFW, RIGHT MAIN LANDING GEAR RED LIGHT ILLUMINATED AND REMAINED ON FOR DURATION OF FLIGHT. RIGHT MAIN LANDING GEAR RED LIGHT EXTINGUISHED WHEN GEAR HANDLE WAS LOWERED AND RECEIVED DOWN AND LOCK INDICATION. LANDED DSDR AALA981827Sensor · malfunctionedORD - FLT 1798 - EN ROUTE IAH-ORD, RIGHT MAIN GEAR RED LIGHT ILLUMINATED TWICE INTERMITTENTLY ON TAKEOFF ROLL. LANDED ORD WITHOUT INCIDENT. REPLACED DOWNLOCK SENSOR AT RIGHT POSITION. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980938Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, LEFT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED LEFT AFT OVERWING EMERGENCY LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980328Shear Tie · corrodedTUL - STA 580 ABOVE STR 27L - BULGE IN SKIN. REMOVED/REPLACED SHEAR TIE, SRM 51-10-1. TST: 58,400 HOURS. CYCLES: 37,776. (X)SDR AALA980311Skin · corrodedTUL - SKIN BULGED STA 512 AT STR 27R. INSTALLED SKIN REPAIR PER SRM 53-30-3 FIG 3 AND INSTALLED STRINGER REPAIR PER SRM 53-10-3 FIG 7. TST: 58,400 HOURS. CYCLES: 37,776. (X)SDR AALA970297Floor Pan · corrodedTUL - CORROSION LAV FLOOR PAN (AROUND DRAIN LINE THROUGH HOLE) STATION 1169 LBL 41 INCH AREA OF CORROSION 2.5 INCH BY 3 INCH LEFT AFT LAV. REPAIRED FLOOR PAN IAW 727 SRM 51-40-2. (M)SDR AALA970296Intercostal · corrodedTUL - STRINGER 20R INTERCOSTAL CORRODED STATION 360-370. REPAIRED STRINGER AND INTERCOSTAL 20R 53-10-3 PG 1-6 TYPE II. (M)SDR AALA970295Stringer · corrodedTUL - VERT FIN STATION 87 STRINGER 3R CORRODED AT ATTACH POINT TO NR 5 RIB. REPAIRED STRINGER 3R VERT FIN STATION 87 IAW ESO 11697 AND SRM 51-40-4. (M)SDR AALA970294Stringer · crackedTUL - STRINGER 15R CRACKED FORWARD OF WING LIGHT HOUSING STATION 720B PLUS 4 INCHES. REMOVED CRACKED STRINGER AND INSTALLED STRINGER SPLICE PER SRM 53-10-3 PAGES 1-4B. (M)SDR AALA970293Stringer · crackedTUL - STRINGER 15L CRACKED ON END TO FASTENER HOLE, AFT SIDE OF WING ICE LIGHT STATION 720B PLUS 15 INCHES. OVERSIZED FASTENER HOLE AND INSTALLED REPAIR DOUBLER PER SRM 53-10-3 FIG 2, E58 2061537. (M)SDR AALA970292Stringer · corrodedTUL - VERT FIN STRINGER 1L, CORRODED UNDER LEVELING COMPOUND AT RIB NR 5 ATTACH POINT. CUT OUT DAMAGED AREA, DRILLED UP AND INSTALLED REPAIR ANGLES AND CLIPS AND FILLER PER SRM 55-30-4. (M)SDR AALA951774Line · rupturedMAI - FLT NR 0827 - EN ROUTE FLL-DFW - AFTER TAKEOFF, WHILE TRYING TO RETRACT LANDING GEAR, HYDRAULIC SYSTEM 'A' QUANTITY AND PRESSURE WENT TO ZERO. BOTH MAIN GEARS STAYED DOWN, NOSE GEAR RETRACTED. MANUALLY EXTENDED NOSE GEAR AND AIR INTERRUPTED AND LANDED SDR AALA951625Eel Strip · defectiveDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PASSENGER SEAT ROWS 16D AND 19D INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT STRIP BETWEEN PASSENGER SEAT ROWS 16D AND 19D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)