TUL - FOUND HEAVY FRAME SPLICE STRAP ON UNDERSIDE OF FRAME CORRODED AT TWO NUT PLATE ATTACH POINTS STATION 616, LOWER AFT CORNER OF DOOR OPENING. REPLAED TAPERED STRAP AS PER SRM 51-10-1. (M)