N846AT, cancelled Aug 15, 2013
Service difficulty reports · 43
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N846AT' AND deregistration_id = 'N846AT-2013-08-15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N846AT' AND deregistration_id = 'N846AT-2013-08-15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AT0200055Power Supply · dischargedOVERWING EMERGENCY LIGHTS STAY ON WHEN BATTERY SWITCH IS OFF. REMOVED AND REPLACED BATTERY PACK POWER SUPPLY.SDR AT0200042Odor · detectedSTRONG ACIDIC SMELL FROM GALLEY AREA, COFFEE MAKER ON FORWARD SIDE OF AIRCRAFT RIGHT. TURNED GALLEY POWER OFF, SMELL DISSIPATE. REMOVED ALL 3 COFFEE MAKERS AND INSPECTED WIRING TO EACH, NO DISCREPANCIES NOTED. INSPECTED ALL WIRING INSIDE FORWARD GALLEY, NO SDR AT0100179Battery Pack · dischargedFOUND EMERGENCY LIGHTS CHARGING CIRCUIT BREAKER POPPED. REPLACED EMERGENCY NACELLE FLOOD LIGHT BATTERY PACK IAW DC9 MM 33-53.SDR AT0100005Power Supply · dischargedFOUND FORWARD OVERHEAD EMERGENCY LIGHT WOULD NOT ILLUMINATE. REMOVED AND REPLACED POWER SUPPLY LOCATED AT FORWARD AISLE OVERHEAD SERVICE ACCESS PANEL IAW DC9 MM 33-50.SDR AT0100082Skin · damagedNEEDED TO REPLACE SKIN AT BS 229-393. REPLACED SKIN IAW RES 00-11-86.SDR AT0100081Attach Angle · crackedFOUND RIGHT DORSAL FIN ATTACH ANGLE CRACKED. REPLACED ATTACH ANGLE IAW EO 09-5350-29-E1645.SDR AT0100080Stringer · corrodedFOUND STRINGER 21 AT BS 230-360 CORRODED BEYOND LIMITS. REPLACED STRINGER 21 IAW DC9 SRM 51-30-02 AND 51-10-03.SDR AT0100079Stringer · corrodedFOUND STRINGER 20R BS 230-360 CORRODED BEYOND LIMITS. REMOVED AND REPLACED STRINGER 20R BS 230-360 IAW DC9 SRM 51-30-02 AND 51-10-03.SDR AT0100083Rib · crackedFOUND LEFT FLAP INNER SUPPORT RIBS CRACKED. INSTALLED 2 ANGLE REPAIRS IAW DC9 SRM 51-10, 57-01, AND 51-10-02.SDR AT0000506Stringer · corrodedFOUND STRINGER 20R AND 21R BS 230 - 360 CORRODED BEYOND LIMITS. REMOVED AND REPLACED STRINGER 20R AND 21R BS 230 - 360 IAW DC9 SRM 51-10-03.SDR AT0000306Slide · dislodgedFOUND L-1 DOOR SLIDE PACK FELL OUT. REINSTALLED L-1 DOOR SLIDE PACK, IAW DC9 MM 25-62.SDR AT0000174Light · inoperativeFOUND OVERHEAD AISLE EMERGENCY LIGHTS AT ROW 2 AND 3 INOPERATIVE. CORRECTIVE ACTION: CLEANED BATTERY PACK CONNECTION IAW DC9 MM.SDR AT0000087Bulb · failedFOUND AFT EMERGENCY SIGN, NEAR AFT DOOR, HAS BURNT BULBS. RELAMPED, IAW DC9 MM 33-50.SDR AT9900844Spar · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LEFT WING LOWER AFT SPAR FLANGE TO BE CORRODED AT BS 477.35. FABRICATED AND INSTALLED SPAR IAW EO 99-1384.SDR AT9900856Spar · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LEFT WING AFT SPAR FLANGE CORRODED BEYOND LIMITS AT BS 550. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC9 SRM 51-30-02, 51-30-03, AND 51-30-05.SDR AT9900825Fitting · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LEFT FRAME ATTACH FITTING CORRODED BEYOND LIMITS AT FLOOR LEVEL. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DC9 SRM 51-10-03, 51-30, AND EO 99-1357.SDR AT9900824Skin · dentedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND DENT AT BS 945. FABRICATED AND INSTALLED SKIN REPAIR AT BS 945 IAW RES 07441 AND EO 99-1364.SDR AT9900823Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LIGHTNING STRIKE AT CABIN WINDOW 32. BLENDED LIGHTNING STRIKE, FABRICATED, AND INSTALLED DOUBLER IAW DC9 SRM 53-05 FIG 111 AND EO 99-1341.SDR AT9900822Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LIGHTNING STRIKE AT CABIN WINDOW 4. BLENDED LIGHTNING STRIKE, FABRICATED, AND INSTALLED DOUBLER IAW DC9 SRM 53-05 FIG 111 AND EO99-1343.SDR AT9900821Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LIGHTNING STRIKE AT CABIN WINDOW 36. BLENDED LIGHTNING STRIKE, FABRICATED, AND INSTALLED DOUBLER IAW DC9 SRM 53-05 FIG 111 AND EO 99-1342.SDR AT9900820Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LIGHTNING STRIKE AT CABIN WINDOW 33. BLENDED LIGHTNING STRIKE, FABRICATED, AND INSTALLED DOUBLER IAW DC9 SRM 53-05 FIG 111 AND EO 99-1340.SDR AT9900819Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LIGHTNING STRIKE AT CABIN WINDOW 25. BLENDED LIGHTNING STRIKE, FABRICATED, AND INSTALLED DOUBLER IAW DC9 SRM 53-05 FIG 111 AND EO 99-1339.SDR AT9900818Skin · lightning strikeDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LIGHTNING STRIKE AT CABIN WINDOW 21. BLENDED LIGHTNING STRIKE, FABRICATED, AND INSTALLED DOUBLER IAW DC9 SRM 53-05 FIG 111 AND EO 99-1338.SDR AT0000129Trunnion · corrodedFOUND RIGHT MAIN LANDING GEAR TRUNNION MOUNT HOLE FOR FIXED SIDE BRACE HAS SURFACE CORROSION. REMOVED CORROSION, FABRICATED REPLACEMENT SHIM AND REINSTALLED FIXED SIDE BRACE IAW DC9 MM 51-10-3 AND EO 99-1370.SDR AT9900812Window Frame · gougedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND GOUGES IN PILOT'S SLIDING WINDOW FRAME. BLENDED OUT GOUGES IN PILOT'S SLIDING WINDOW FRAME IAW EO 991367.SDR AT9900807Frame · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK OUT OF LIMITS IN MAIN FRAME AT BS 718 LEFT. REMOVED AND REPLACED MAIN FRAME AT BS 718 LEFT IAW DC9 SB 53-131.SDR AT9900806Frame · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK OUT OF LIMITS IN MAIN FRAME AT BS 718 RIGHT. REMOVED AND REPLACED MAIN FRAME AT BS 718 RIGHT IAW DC9 SB 53-131.SDR AT9900811Doubler/Longeron · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK AT BS 230 LONGERON 21 LEFT. FABRICATED AND INSTALLED FILLER, DOUBLER, AND LONGERON SPLICE IAW DC9 SRM 51-10-02, 51-10-03, 51-10-04, 51-30, 51-30-02, 51-30-05, 25-52, AND EO 99-1335.SDR AT9900808Doubler · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND UPPER PRESSURE WEB DOUBLER AT BS 718 LEFT CORRODED BEYOND LIMITS. REMOVED, FORMED, AND INSTALLED NEW DOUBLER AT BS 718 LEFT IAW DC9 SRM 53-01 FIG 1, 51-10-02, 51-10-02A, 51-10-03, AND 51-10-04.SDR AT9900780Jamb · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND R-1 DOOR JAMB PAN TO HAVE CORROSION, HOLE, AND DENT IN AFT SIDE. REMOVED AND REPLACED TRANSITION PANEL, FLOOR SUPPORT, AND FORWARD SEAL ANGLE IAW DC9 SRM 51-10-04, 53-05 FIG 55, 51-10-2A, 51-10-03,SDR AT9900756Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM TO BE CORRODED AROUND NUT PLATE HOLE. CUT OUT CORRODED SECTION AT BS 237 RBL 52 AND FABRICATED REPAIR ANGLE, FILLER, AND RUB STRIP IAW DC9 SRM 53-06 FIG 20A, 51-10-02, 51-10-03, 51-10-04,SDR AT9900809Cusp Web · corroded/crackDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CUSP WEB AT BS 238 RIGHT TO BE CORRODED AND CRACKED. REMOVED DAMAGED AREA FABRICATED REPAIR AND INSTALLED DOUBLER IAW DC9 SRM 53-01 FIG 4, 51-10-03, AND 51-30-02.SDR AT9900778Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND WEB SUPPORT AT BS 718 LBL 56 TO BE CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS. FORMED NEW WEB SUPPORTS AND INSTALLED IAW DC9 SRM 51-10-03, 53-01 FIG 1, 51-10-02, 51-10-04, AND 51-30-02.SDR AT9900817Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON OVERWING PRESSURE PANEL AT BS 705 LBL 50 BLENDING CAUSED OUT OF LIMITS. REMOVED CORROSION AND INSTALLED FILLER AND DOUBLER AT BS 705 LBL 50 IAW EO 99-1348.SDR AT9900781Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOORBOARD SUPPORT HAT CHANNELS BETWEEN BS 200 AND BS 218 TO BE CORRODED. REMOVED AND REPLACED HAT CHANNELS IAW DC9 SRM 51-30-02.SDR AT9900779Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORTS FROM LEFT TO RIGHT SIDE AT BS 200 AND FORWARD ENDS OF SEAT TRACKS TO HAVE CORROSION. REPLACED FLOOR SUPPORTS AND TREATED SEAT TRACKS IAW DC9 SRM 51-30-02 AND 51-10-03.SDR AT9900772Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON FLOOR SUPPORT AT BS 160 TO BS 200. REMOVED AND REPLACED FLOOR SUPPORT AT BS 160 TO BS 200 IAW DC9 SRM 53-11-01, 51-10-02, 51-10-03, 51-10-04, AND 51-30-02.SDR AT9900769Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT TO BE CORRODED BEYOND LIMITS. CLEANED CORROSION AT BS 153, FABRICATED NEW FLOOR SUPPORT AND INSTALLED AT BS 157 IAW DC9 SRM 53-01 FIG 1, 51-10-03, 53-11-01 FIG 13, 51-30-02, AND CALIPSDR AT9900810Spar Cap · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON RIGHT WING AFT SPAR UPPER CAP AT XRS 387-400. FABRICATED AND INSTALLED REPAIR STRAP AT XRS 387-400 IAW DC9 SRM 57-09 FIG 12, 51-10-03, 51-30, AND EO 99-1344.SDR AT9900773Skin · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION AT BOTTOM OF FORWARD CARGO DOOR JAMB. FABRICATED AND INSTALLED FILLER, DOUBLER, AND TRIPLER AT BS 370-427 IAW DC9 SRM 51-10-03, 51-10-04, 51-10-05, 51-30-01, 51-30-02, AND EO 99-1329.SDR AT9900759Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND COCKPIT FLOOR SUPPORT FLANGE CORRODED BEYOND LIMITS. FABRICATED FLOOR SUPPORT FLANGE AT BS 150 LBL 14 IAW SRM DC9 53-01 FIG 1, 51-10-02, 51-10-03 AND 51-30-03.SDR AT9900609Wire · brokenFOUND EMERGENCY PATH LIGHT DIM AT ROW 19. REPAIRED WIRING IAW MM 20-50-1. OPS CHECK GOOD IAW BRUCE INDUSTRIES MM 33-21-27.SDR AT9900077Power Supply · inopFOUND FORWARD SECTION OF EMERGENCY FLOOR TRACK LIGHTS WILL NOT ILLUMINATE. REMOVED AND REPLACED BATTERY POWER SUPPLY, SYSTEM OPS CHECK GOOD IAW MM 33-50.