What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CUSP WEB AT BS 238 RIGHT TO BE CORRODED AND CRACKED. REMOVED DAMAGED AREA FABRICATED REPAIR AND INSTALLED DOUBLER IAW DC9 SRM 53-01 FIG 4, 51-10-03, AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CUSP WEB AT BS 238 RIGHT TO BE CORRODED AND CRACKED. REMOVED DAMAGED AREA FABRICATED REPAIR AND INSTALLED DOUBLER IAW DC9 SRM 53-01 FIG 4, 51-10-03, AND 51-30-02.