N860GA, cancelled Jan 7, 2015
Service difficulty reports · 74
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N860GA' AND deregistration_id = 'N860GA-2015-01-07' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N860GA' AND deregistration_id = 'N860GA-2015-01-07' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2013122071794Acm · odorBOTH APU`S RUNNING A/C PACKS, EXHAUST ODOR IN CABIN. REMOVED AND REPLACED LEFT AIR CYCLE MACHINE. OPS AND LEAK CHECKED OK IAW AMM 21-51-01.SDR WX0A2013120400769Control Valve · burnedAPU SUSPECTED OF CAUSING CABIN ODOR. R & R APU LOAD CONTROL VALVE IAW AMM 49-50-01 PARA 2 A & B. BURNED OIL DISCOLORATION AT 7 O`CLOCK ON PREVIOUSLY INSTALLED VALVE.SDR WX0A2013090571683Battery · dischargedFWD AED LOW BATTERY. R & R FWD DEFIBULATOR BATTERY IAW AMM 25-60-01.SDR WX0A071353Skin · corrodedANTENNA CUTOUT BETWEEN STA 229 TO STA 237 DOUBLER/TRIPLER CORRODED, CUTOUT DAMAGED AREA. REMOVED AND REPLACED LOWER SKIN STATION 229 TO STATION 275 LONGERON 26R TO LONGERON 27L IAW MD80 SRM 53-04 FIGURE 12C.SDR WX0A071341Spar · corrodedLEFT WING O/B FLAP CENTER HINGE FITTING UPPER I/B ATTACH FITTING HOLE SURFACE CORRODED STA XRS267.00 OF WING REAR SPAR. REMOVED DAMAGE, FABRICATED FILLER, HFEL SPAR & BOND IN REPAIR PART IAW EA 14874IR 09/23/2012.SDR WX0A071320Pan · bentAFT CARGO DOOR ENTER PAN BENT AT FWD LOWER EDGE. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED IAW STS EA 12-2012-308 DATED 09/14/2012.SDR WX0A071319Longeron · corrodedAFTER INTERNAL OPEN UP OF AFT CARGO ANTENNAS, AREA AT LONGERON 30 IS CORRODED BETWEEN FS 1155 AND FS 1174. REPAIRED LONGERON 30 BY FABRICATING U-CHANNELS, SHIMS AND INSTALLING REPAIR PARTS IAW STS EA 10-2012-203.SDR WX0A071318Skin · dentedRIGHT FWD FUSELAGE STA 256 LONGERON 18R TO 20R HAS THREE SHARP DENTS. REMOVED DAMAGE STA 227 TO 269.5 LONGERON 18R TO 20R. FABRICATED ALL PARTS AND INSTALLED IAW MD80 SRM 53-04 FIG 12C.SDR WX0A071316Seat Track · corrodedAFT PASSENGER CABIN SEAT TRACK STA 1155 TO 1250 LBL 22 CORRODED. REMOVED AND REPLACED SEAT TRACK WITH SPLICE AT STA 1250 & 1871 IAW MD-80 SRM 51-30-1.SDR WX0A071263Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071182Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071181Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ASDR WX0A071156Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071155Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2012020371107Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN THE POWER SUPPLY BATTERY PACK. AN OPERATIONAL CHECK WAS ACCOMPLSDR WX0A2012012871095Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED BATTERY PACK IN THE POWER SUPPLY AND OPS CHECK WAS ACCOMPLISHED PER AMM 33-50-0SDR WX0A071088Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE PORTABLE EMERGENCY EXIT LIGHT ASSY ASDR WX0A070997Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070975Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070974Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070908Coalescer Bag · dirtyAIR RETURN DUE TO SMELL OF BURNING AND SMOKE IN CABIN. DROPPED PSU'S AND CLEANED PANELS, NO ODORS OR EVIDENCE OF BURNING NOTED. REMOVED AND REPLACED COALESCER BAGS, REF AMM 21-20-02 RAN ENGINES REF AMM 71-00-00 OPS CHECK NORMAL. AIRCRAFT RETURNED TO SERVICESDR WX0A070892Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE EMERGENCY FLASHLIGHSDR WX0A070781Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070776Membrane · crackedFWD CABIN FLOOR WEB MEMBRANE CRACKED AT STA 200, RBL 40 TO RBL 46. REMOVED DAMAGED WEB RBL 25 TO RBL 56 STA 200 TO STA 218. FABRICATED, LOCATED, DRILLED AND INSTALLED IAW MD80 SRM 51-30-2 AND SRM 51-30-5.SDR WX0A070775Angle · corrodedCABIN FLOOR UPPER CUSP ANGLE CORRODED AT R1 DOOR JAMB. CUT OUT DAMAGED AREAS, FABRICATED, LOCATED, DRILLED AND INSTALLED CUSP ANGLE, SPLICES SHIMS, DOUBLERS AND FILLERS IAW MD80 SRM 53-05 FIG 55.SDR WX0A070767Diaphragm · corrodedFWD CABIN MEMBRANE WEB CORRODED AND DENTED STA 200. CUT OUT DAMAGED WEB STA 160 TO STA 200, LBL 10 TO RBL 60. FABRICATED, LOCATED, DRILLED AND INSTALLED WEB REPAIR IAW MD80 SRM 51-70-4 FIG 2.SDR WX0A070766Doubler · corrodedDOOR WEB DOUBLER STA 160 TO STA 200, RBL 54 TO RBL 60 CORRODED. FABRICATED AND INSTALLED NEW DOUBLER IAW MD80 SRM 51-30-2.SDR WX0A070765Membrane · corrodedWEB MEMBRANE RBL 7 TO RBL 40 STA 120 TO STA 150 CORRODED. REMOVED, FABRICATED NEW AND INSTALLED MEMBRANE IAW MD80 SRM 51-70-4 FIG 2.SDR WX0A070764Seat Track · corrodedCOPILOTS INBOARD SEAT TRACK CORRODED. ORDERED AND RECEIVED NEW TRACK, LOCATED AND DRILLED IAW MD80 SRM 51-10-4.SDR WX0A070763Seat Track · corrodedCOPILOTS OUTBOARD SEAT TRACK CORRODED. ORDERED AND RECEIVED NEW TRACK LOCATED AND DRILLED IAW MD80 SRM 51-10-4.SDR WX0A070640Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070537Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070535Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REPLACED EMERGENCY LIGHT ASSEMBLY AS REQUIRED. A SATISFACTORY OPERATIONASDR WX0A070533Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070522Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070502Power Supply · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070417Battery Pack · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070389Web · corrodedIN WORK, BOW 1C/5C/S1 FOUND CORROSION ON SURFACE OF WEB.SDR WX0A070388Track · corrodedCORROSION ON RT TIE DOWN TRACK BETWEEN STA 1212 - 1322.SDR WX0A070387Track · corrodedCORROSION IN LT TIE DOWN TRACK BETWEEN STA 1220-1322.SDR WX0A070386Cargo Track · corrodedAFT CARGO LT TIE DOWN TRACK SPLICE CORRODED AT STA 1220. INSTALLED A SERVICEABLE TIE DOWN TRACK SPLICE PER SRM 51-30-05.SDR WX0A070385Skin · crackedCRACKS ON FUSELAGE SKIN STA 1380 L14R (2EA).SDR WX0A070384Cusp Web · corrodedCUSP WAS FOUND TO HAVE CORROSION ON BOTTOM SIDE OF CUSP AT STA 845-907 LT.SDR WX0A070379Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070356Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070279Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070269Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR 070156Deice System · failedDURING PILOTS PREFLIGHT INSPECTION, SMOKE STARTED TO FILL THE COCKPIT. NOTICED THE SMOKE COMING FROM THE CAPTAINS LEFT CORNER OF THE WINDSHIELD. SHUT OFF ALL AC ELECTRICAL POWER AND SMOKE WAS EXTINGUISHED. WINDSHIELD DE ICE SYSTEM WAS DEFERRED IAW ALLEGIANSDR WX0A070147Battery Pack · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR 070129Outflow Valve · obstructedAIRCRAFT 860 DEPARTED LAS FLT 418 AND CLIMBING THROUGH 18,000 FEET THE CABIN PRESSURIZATION FLOW LIGHT ILLUMINATED. CREW WAS UNABLE TO EXTINGUISH LIGHT AND RETURNED TO LAS. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED THE PRESSURIZATION SYSTEM AND DISCOVERED I