What was found
CABIN FLOOR UPPER CUSP ANGLE CORRODED AT R1 DOOR JAMB. CUT OUT DAMAGED AREAS, FABRICATED, LOCATED, DRILLED AND INSTALLED CUSP ANGLE, SPLICES SHIMS, DOUBLERS AND FILLERS IAW MD80 SRM 53-05 FIG 55.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR UPPER CUSP ANGLE CORRODED AT R1 DOOR JAMB. CUT OUT DAMAGED AREAS, FABRICATED, LOCATED, DRILLED AND INSTALLED CUSP ANGLE, SPLICES SHIMS, DOUBLERS AND FILLERS IAW MD80 SRM 53-05 FIG 55.