N876GA, cancelled Dec 31, 2022
Service difficulty reports · 63
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N876GA' AND deregistration_id = 'N876GA-2022-12-31' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N876GA' AND deregistration_id = 'N876GA-2022-12-31' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2018051473320Control Panel · malfunctionedMID CARGO FIRE ALARM AT FL320. EMERGENCY DECLARED. R & R ALL THREE CARGO SMOKE DETECTORS AND CARGO FIRE CONTROL PANEL.SDR WX0A201710090001Iru · failedDUAL MAP FAILURE, EMERGENCY DECLARED. R & R THE NR 1 & 2 IRU.SDR WX0A2017100373290Garlock Seal · leakingNR 1 ENG OIL QTY STEADILY DECREASED THROUGHOUT THE FLIGHT, ENGINE SHUTDOWN. R&R NR 1 ENG GARLOCK SEAL AND HOUSING FOR N2 TACH GEN.SDR WX0A2016070873174Holder · looseREAR F/A REPORTS BURNING, PLASTIC ODOR, BURNING POPCORN ODOR. PULLED C/B, ALL F/A REPORTED ODOR MOVING FORWARD FROM REAR CABIN PROGRESSIVELY GETTING HEAVIER. DESCENDED WHILE PERFORMING ON PACK OFF 1 ON. NO CHANGES, DIVERTED. ON GROUND ODOR STILL EVIDENT, FSDR WX0A2015121573043Battery · dischargedAFT OVERWING EMER EXIT ON BOTH RT & LT EXITS ARE INOPERATIVE. REPLACED BATTERIES IAW MM 33-50-00. OPERATIONS CHECKED GOOD.SDR WX0A2015110872989Flashlight · inoperativeFLIGHT ATTENDANT REPORTS FWD FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT ASSEMBLY IAW 25-60-00. OPERATIONS CHECKED GOOD.SDR WX0A2015101972947Power Supply · inoperativeFOUND ON WAKE UP, TAIL CONE & AFT FLIGHT ATTENDANT EMER LIGHTS INOPERATIVE. CHECKED BATTERIES, CHECKED GOOD. RELAMPED TAIL CONE BULBS, NO HELP. REPLACED FWD POWER SUPPLY, OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR WX0A2015091572862Tab · delaminatedLEFT ELEVATOR CONTROL TAB INBD END, PREVIOUS REPAIR DELAMINATED AT STATION XE 14.525. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS, ACCOMPLISHED HOT BOND REPAIR IAW SRM 55-04 PARA 3 FIG 2 PAGES 9 & 10. WORK ACCOMPLISHED ON WO 262843 M301 ITEM 337, WO 101201SDR WX0A2015090172838Floor Support · corrodedFLOOR SUPPORT CORRODED, FS 200, LBL44. FABRICATED REPLACEMENT SUPPORT IAW SRM 51-10-4 M301 NR 588. R & R SUPPORT IAW SRM 51-30-2 M301 NR 587.SDR WX0A2015090172839Seat Track · corrodedSEAT TRACK CORRODED FROM FS 200 - FS 241, RBL 22. R & R SEAT TRACK FS 200 - 241, RBL22 IAW SRM 53-05 FIG 4F.SDR WX0A2015071772740Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE AT AFT NONSTANDARD DROP CEILING PANEL. R & R BATTERY POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-04.SDR WX0A2015070672715Light · inoperativeL1 DOOR EMER LIGHT INOPERATIVE. R & R L1 DOOR EMER EXIT LIGHT. CABIN OPERATIONS CHECKED GOOD IAW AMM 33-53-00-4-0.SDR WX0A2015062272675Structure · dentedLEFT ENG PYLON TE DENTED 13"" FROM INBD EDGE, MEASURES 3.6"" X 2.1"" X 0.081"". OUT OF LIMITS IAW SRM 51-50-2 PAGE 4 FIGURE 1 SHEET 1. INSPECTION LT ENG PYLON TE IAW EA 25-2015-17. ACCOMPLISHED A DETAILED VISUAL INSPECTION, IAW SECTION 1 INTERIM REPAIR. FOSDR WX0A2015081172789Csd · lowAFTER ENG RUNS & MX SIGNOFF, THE FLIGHT DEPARTED, ABOUT 10 MINUTES INTO THE FLIGHT THE CREW NOTED THAT THE LT CSD, WHICH WAS THE ONE THAT HAD BEEN REPLACED WAS RUNNING HOT. THE LT CSD WAS AT 180C WITH A RISE TEMP OF 15 - 16 C. THE CREW EXECUTED QRH 24.16, CSSDR WX0A2015060172628Unknown · odorFLIGHT ATTENDANTS & PAX COMPLAINING OF STRONG FUEL SMELL DURING TAXI OUT. RETURNED TO GATE. ACCOMPLISHED TC 21-059-002 CABIN ODOR & SMOKE. TROUBLESHOOTING ACCOMPLISHED TC 21-059-008 ALTERNATE SERVICING AIR CONDITIONING WATER SEPARATOR & PACK BURNOUT PROCEDUSDR WX0A2015050172566Battery · dischargedEMERGENCY LIGHTS AT BACK OF OVERHEAD PANEL IN COCKPIT WILL NOT TEST. REPLACED EMER LIGHT BATTERIES FOR COCKPIT OVERHEAD. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A2015042272545Shutoff Valve · faultyFLIGHT ATTENDANTS REPORTED A BURNING RUBBER SMELL AFTER TAKEOFF. TROUBLESHOOTING PERFORMED ON WO 252674. LT PRESS REGULATING & SOV IDENTIFIED AS FAULTY. R & R LT PRSOV. OPERATIONS & LEAK CHECKED GOOD IAW AMM 21-31-01. THIS ACFT OK FOR CONTINUED SERVICE.SDR WX0A2015032672479Hydraulic Line · crackedDURING DESCENT, NOTICED LT HYD PRESS READ 6 AT LAS QTY. AT LAS IT READ 12, PERFORMED QRH, HYD LEAK SUSPECTED. AFTER LANDING FLUID PRESS & QTY BOTH WENT TO ZERO. FOUND LARGE HYD PUDDLE BY AFT STAIRS. FOUND CRACK IN LINE BETWEEN LT TR CONTROL VLV & FILTER. SDR WX0A2015012072362Light · inoperativeROW 10 EMER LAMP INOPERATIVE. RELAMPED EMER LAMP IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A2014120272291Rudder Pedal · jammedRUDDER PEDALS JAMMED ON LANDING ROLL. INSPECTED RUDDER TRAVEL LIMITER, RUDDER PITOT HEAT & RUDDER ACTUATOR FOR OPERATION & BINDING. NO DISCREPANCIES FOUND. ALSO LUBED COMPONENTS. PERFORMED WORK IAW 27-20-00. OPERATIONS CHECKED GOOD.SDR WX0A2014090372131Light · inoperativeEMERGENCY LIGHT AT ROW 22 OVERHEAD INOPERATIVE, RELAMPED. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A2014080572072Warning System · false activationTAIL COMPARTMENT TEMP HIGH LIGHT. RAN QRH 21.4, LIGHT EXTINGUISHED AT 2 MINUTES. COMPLIED WITH WORK ORDER 230201 ITEM 1. PERFORM TASK CARD I0592101 TAIL COMPARTMENT HIGH TEMP CHECK. OPERATIONS CHECKED GOOD.SDR WX0A071861Doubler · chafedLEFT OTBD FLAP, INBD VANE LE DOUBLER IS CHAFED. REMOVED DAMAGED DOUBLER & INSTALLED PERMANENT REPAIR IAW SRM 51-70-2 PARA 18B PG 91-95.SDR WX0A071856Scuff Plate · crackedMID PIT RT AFT SCUFF PLATE IS CRACKED. FABRICATED NEW MID PIT RT AFT SCUFF PLATE IAW SRM 51-10-4.SDR WX0A2013072536Lamp · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY LIGHT SYS WOULD NOT TEST. REPLACED LAMPS. OPS CHECK SATISFACTORY IAW AMM 33-50-00. ACFT RETURNED TO SERVICE.SDR WX0A2013051371576Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2013032171540Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A2013031371536Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A2013031371535Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A2013031371534Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071410Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071301Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071280Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071267Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071253Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071252Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071214Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071203Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071202Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ASDR WX0A071201ABattery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071200ABattery · dischargedREPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK SDR WX0A2012031371120Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ASDR WX0A071089Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071070Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071071Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071051Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071050Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071049Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070873Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070805Wire · brokenFLIGHT CREW REPORTED LEFT ENGINE OIL TEMP FLUCTUATED BETWEEN APPROX. 120-152 C'. ADVANCING THE THROTTLE REDUCED TEMPERATURE PER QRH. TEMP WENT UNCONTROLLED TO 199 C'. ENGINE SHUTDOWN PER QRH. ENGINE OIL PRESSURE AND QUANTITY WAS IN THE NORMAL RANGE PRIOR T
Back to N876GA, cancelled Dec 31, 2022