N877GA, cancelled Oct 1, 2022

Service difficulty reports · 70

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N877GA' AND deregistration_id = 'N877GA-2022-10-01'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JR2R20171014211Frame Angle · crackedRIGHT CANTED FRAME ANGLE CRACKED, AFT SIDE. REMOVED AND REPLACED THE FRAME ANGLE IAW SRM 51-10-4.Oct 14, 2017 · N877GA · Doug MD83 · Fuselage Main, FrameSDR JR2R20171014210Frame Angle · crackedLEFT CANTED FRAME ANGLE CRACKED LT AFT SIDE. REMOVED AND REPLACED THE FRAME ANGLE IAW SRM 51-10-4.Oct 14, 2017 · N877GA · Doug MD83 · Fuselage Main, FrameSDR JR2R20141012185Window Frame · crackedRT WINDOW FRAME CRACKED UPPER FWD CORNER. REPAIRED THE WINDOW FRAME IAW SRM 53-05, FIG 122.Oct 12, 2017 · N877GA · Doug MD83 · Fuselage Main, StructureSDR JR2R20171011209Guard · crackedAFT ACCESSORY COMPARTMENT EMERGENCY EGRESS CATWALK FWD OUT BOARD HINGED WALK GUARDS CRACKED. REPAIRED AFT ACCESSORY EMERGENCY EGRESS CATWALK FWD OUT BOARD HINGED WALK GUARDS IAW MD80 SRM 53-01 FIG 1.Oct 11, 2017 · N877GA · Doug MD83 · Fuselage, Door HingeSDR WX0A2016020473087Servo Valve · failedTHE CREW WAS USING AUTO BRAKES FOR LANDING. THE AUTO BRAKES WERE DISENGAGED BETWEEN 120 - 100 KTS BY APPLYING MANUAL BRAKING. WHEN THE AUTO BRAKE SYS WAS DISENGAGED THE CREW FELT A JOLT BUT THE ACFT STAYED ON THE CENTERLINE THROUGHOUT THE ROLLOUT. THE ACFT Feb 3, 2016 · N877GA · Doug DC983 · Landing Gear Brake SystemSDR WX0A072960Light · inoperativeEMERGENCY LIGHT ABOVE ROW 8 INOPERATIVE. R & R EMER LIGHT BULB ABOVE ROW 8 IAW 33-53-00. OPERATIONS CHECKED GOOD.Oct 21, 2015 · N877GA · Doug DC983 · Emergency LightingSDR WX0A072899Warning System · false activationAFTER GEAR RETRACTION, RT MAIN GEAR UNSAFE LIGHT, REMAINED ON. FOLLOWED QRH 32.9, RED GEAR LIGHT ON WITH GEAR HANDLE UP. AFTER GEAR EXTENSION & RETRACTION, RED LIGHT EXTINGUISHED. PERFORMED PROXIMITY SENSOR ELEC UNIT TEST IAW AMM 32-60-04-02-0, NO DEFECTS NSep 25, 2015 · N877GA · Doug DC983 · Landing Gear Position and WarningSDR WX0A2015092172879Switch · defectiveAUTO BRAKES DISENGAGE ON TOUCHDOWN. R & R AUTO BRAKE DISCONNECT SWITCH S1-441 IAW AMM 32-44-00-2-0. OPERATIONS CHECKED GOOD.Sep 21, 2015 · N877GA · Doug DC983 · Landing Gear Brake SystemSDR WX0A2015092172876Switch · defectiveLANDING GEAR HORN WOULD NOT SILENCE ON VARIOUS CONFIGURATIONS, FLAP & SLATS 0, SLATS EXTENDED FLAPS 15. R & R LG SILENCE HORN SWITCH. OPERATIONS CHECKED GOOD IAW AMM 31-51-00.Sep 20, 2015 · N877GA · Doug DC983 · Landing Gear Position and WarningSDR WX0A2015091872866Battery · dischargedTAIL COMPARTMENT CEILING EMER EXIT LIGHTS INOPERATIVE. R & R BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.Sep 15, 2015 · N877GA · Doug DC983 · Emergency LightingSDR WX0A2015082472830Unknown · malfunctionedAT FL 290, THE FLOW LIGHT ON & THE CABIN BEGAN CLIMBING AT 1000 FEET A MINUTE. CREW ASKED FOR A DESCENT & EXECUTED QRH 21.7 CABIN PRESS OFF SCHEDULE OR ERRATIC CHECKLIST. THE CABIN GOT UP TO 11000 FEET AT ITS HIGHEST POINT. ATC HAD DECLARED THE EMER FOR THEAug 23, 2015 · N877GA · Doug DC983 · Cabin Pressure Control SystemSDR WX0A2015081772812Unknown · odorON TAKEOFF ROLL, THE FLIGHT ATTENDANTS REPORTED THE SMELL OF FUMES. BOTH PILOTS SMELT THE SAME FUMES. CABIN & FIRE QRH & AIR CON SMOKE & FUMES QRH COMPLETED. NO FURTHER DEFECTS NOTED. PERFORMED CABIN, ODOR & SMOKE TROUBLESHOOTING TASK CARD 21-059-002. NO Aug 14, 2015 · N877GA · Doug DC983 · Air Distribution SystemSDR WX0A2015081672806Proximity Sensor · failedAFTER GEAR RETRACTION WE HAD RT RED GEAR LIGHT WITH GEAR HANDLE UP. AFTER QRH PROCEDURE, NOW HAD RT GEAR & NOSE GEAR RED LIGHT WITH GEAR HANDLE UP. ALSO HAD AN AUTO SPOILER FAIL MGS. ADJUSTED RT MAIN GEAR LATCH MECHANISM IAW MM 32-31-04. PERFORMED PROXIMITAug 13, 2015 · N877GA · Doug DC983 · Landing Gear Position and WarningSDR WX0A2015081172787Sensor · out of adjustAT APPROX 2000 FEET ON APPROACH, SPOILER DEPLOYED, LIGHT ILLUMINATED. COMPLETED 360' TURN & LIGHT REMAINED ON. AFTER RESTARTING, APPROACH LIGHT ILLUMINATED INTERMITTENTLY & FINALLY EXTINGUISHED AT 1000 FEET. NO ADVERSE EFFECT NOTED DURING TURN. ADDITIONAL Jul 3, 2015 · N877GA · Doug DC983 · Drag Control SystemSDR WX0A2015070672720Unknown · odorIAW FLIGHT ATTENDANTS, ALL, THEY COULD SMELL A CHEMICAL, BURNT, FOUL SMELL ALL THROUGHOUT THE CABIN FROM TAKE OFF POWER TO ABOUT 15 MIN AFTER TAKEOFF. TAKE OFF INDICATIONS WERE NORMAL, TO TAKEOFF, BLEEDS ON. PERFORMED INSPECTION & TROUBLESHOOTING IAW TC 21-0Jul 2, 2015 · N877GA · Doug DC983 · Air Distribution SystemSDR WX0A2014122272309Light · inoperativeLEFT FWD OVERWING EMER EXIT SIGN HAS ONE LAMP OUT. RELAMPED LIGHT FIXTURE IAW AMM 33-50-00. CHECKED GOOD AT THIS TIME.Oct 15, 2014 · N877GA · Doug DC983 · Emergency LightingSDR WX0A072199Manifold · defectiveON LANDING AUTO BRAKES DISARMED AUTOMATICALLY UPON TOUCHDOWN WITH AUTO BRAKES SET AT MED. TROUBLE SHOT IAW AMM 32-44-00. FOUND LAND MANIFOLD BAD. REPLACED LAND MANIFOLD IAW AMM 32-44-00. OPERATIONS & LEAK GOOD.Oct 13, 2014 · N877GA · Doug DC983 · Landing Gear Brake SystemSDR WX0A071974Skin · scratchedUPPER ETERNAL FUSELAGE SKIN SCRATCHED OUT OF LIMITS AT STATION 349 UNDER VHF ANTENNA. BLENDED TO REMOVE DAMAGE, HFEC INSPECTED WITH NO CRACKS NOTED. FABRICATED REPAIRS SHIM & DOUBLER, LOCATED, DRILLED & INSTALLED IAW EA 10-2014-055.May 30, 2014 · N877GA · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A071852Battery · dischargedEMERGENCY AISLE LIGHTS INOPERATIVE 28 - 29. REPLACED BATTERIES IN BATTERY PACK FOR EMERGENCY AISLE LIGHTS 28 - 29. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.Feb 15, 2014 · N877GA · Doug MD83 · Emergency LightingSDR WX0A07177Battery · dischargedCOCKPIT OVERHEAD LIGHTS DO NOT COME ON WITH EMERGENCY LIGHT TEST. R & R BATTERIES FOR EMERGENCY LIGHTS IN FWD SECTION IAW AMM 33-50-00, OPERATIONS TESTED GOOD.Dec 15, 2013 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071778Battery · dischargedMID CABIN OVERWING EXIT DOOR AFT EMERGENCY LIGHT LOWER INOPERATIVE, BATTERIES ARE OUT OF DATE. R & R BATTERY IAW AMM 33-53-00, OPERATIONS CHECKED GOOD.Dec 14, 2013 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071766Battery Pack · dischargedIN ACCORDANCE WITH MEL 25-09 SIT 1 DMI 5542, AFT CABIN FLASHLIGHT NOT BLINKING. R & R AFT CABIN FLASHLIGHT BATTERY PACK IAW AMM 25-60-00, OPERATIONS CHECKED GOOD. THIS CLEARS MEL 25-09 SIT 1, DMI 5542, INOPERATIVE PLACARD REMOVED.Dec 2, 2013 · N877GA · Doug MD83 · Emergency EquipmentSDR WX0A201310280038Battery Pack · inoperativeCENTER ISLE EMERGENCY LIGHTS AT 29 &31 INOPERATIVE. REPLACED BATTERY PACK BATTERIES FOR 29-31, OPS CK GOOD REF AMM 33-53-00.Oct 26, 2013 · N877GA · Doug DC983 · Emergency LightingSDR WX0A201308130066Flashlight · inoperativeFWD F/A STATION UPPER EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT IAW AMM 25-60-00. OPS CHECKED GOOD.Aug 11, 2013 · N877GA · Doug DC983 · Emergency EquipmentSDR WX0A2013070800028Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPS CHECK WAS ACCOMPLISHED IAW AMM 33-50-00, SYS OPS CHECKED NORMJun 28, 2013 · N877GA · Doug DC983 · Emergency LightingSDR WX0A071599Frame · corrodedAFT CARGO COMPARTMENT FS FRAME 1309 LOWER FLANGE IS CORRODED BETWEEN LONGERON 28R TO 28L. REPAIRED DAMAGED AREA OF FRAME.May 31, 2013 · N877GA · Doug DC983 · Fuselage Main, FrameSDR WX0A071598Door Frame · crackedVENTRAL DOOR SURROUND REVEAL CRACK IN UPPER LEFT CORNER. STOP DRILLED CRACK AND INSTALLED REPAIR DOUBLER.May 29, 2013 · N877GA · Doug DC983 · Fuselage Main, StructureSDR WX0A071595Door Frame · gougedFORWARD CARGO DOOR HYDRO-FORMED FRAME HAS SEVERAL GOUGES AT AFT LOWER CORNER. FABRICATED REPAIR DOUBLER AND INSTALLED.May 23, 2013 · N877GA · Doug DC983 · Cargo/Baggage DoorsSDR WX0A071594Doubler · chafedRIGHT L/B FLAP L/B VANE LEADING EDGE DOUBLER CHAFED. REPLACED DOUBLER.May 23, 2013 · N877GA · Doug DC983 · Trailing Edge FlapsSDR WX0A201305301593Longeron Splice · corrodedFS 1461 LONGERON SPLICE 12L CORRODED. REPLACED LONGERON SPLICE.May 23, 2013 · N877GA · Doug DC983 · Fuselage Main, Longeron/StringerSDR WX0A071592Doubler · chafedRIGHT O/B FLAP L/B VANE LEADING EDGE DOUBLER CHAFED AT I/B CORNER. REPLACED DOUBLER.May 23, 2013 · N877GA · Doug DC983 · Trailing Edge FlapsSDR WX0A2013032171541Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERMar 17, 2013 · N877GA · Doug DC983 · Emergency LightingSDR WX0A071426Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 28, 2012 · N877GA · Doug DC983 · Emergency LightingSDR WX0A071384Skin · corrodedAFT LAV SERVICE PANEL CUTOUT CORRODED BETWEEN FUSELAGE SKIN AND DOUBLER STATION 1309 JUST ABOVE LONGERON 22L.Nov 6, 2012 · N877GA · Doug DC983 · Fuselage Main, Plate/SkinSDR WX0A071411Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ANov 4, 2012 · N877GA · Doug DC983 · Emergency LightingSDR WX0A071363Cusp Web · corrodedCABIN FLOOR CUSP WEB CORRODED OUT OF LIMITS AT STA 370 RBL 47. REMOVED DAMAGED CUSP WEB, FABRICATED, LOCATED, DRILLED CUSP WEB DOUBLER AND INSTALLED IAW MD 80SRM 51-70-4 FIGURE 1 WEB SPLICE REPAIR.Oct 21, 2012 · N877GA · Doug DC983 · Fuselage Miscellaneous StructureSDR WX0A071352Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 6, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071337Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 25, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071336Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 24, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071313Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND RELAMPSep 12, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071254Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJul 27, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071241Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJul 6, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A071162Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERApr 1, 2012 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070991Vane · gougedRIGHT WING INBOARD FLAP VANE GOUGE AT XV2 223. PERMANENT REPAIR APPLIED 4" X 11" EXTERNAL DOUBLER FROM XV2 221 TO XV2 225 IAW BOEING MD80 SRM 57-03 PAGE 27 WITH EXAMPLE 'B" DOUBLER.Nov 6, 2011 · N877GA · Doug MD83 · Trailing Edge FlapsSDR WX0A070932Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 5, 2011 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070931Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 1, 2011 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070924Lens · missingIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. FLOOR PATH LIGHTING STRIP IS MISSING THE LENS COVER. MAINTENANCE DEPARTMENT PERSONNEL HAVE INSPECTED THE SYSTEM AND MADE ALL REQUIRED CORRECTIONSAug 2, 2011 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070906Unknown · odorSMELL COMING FROM AIR CONDITIONING PACKS ON APU AIR, LEAK CHECKED APU AND VERIFIED ACM SERVICE LEVELS. INSPECTED COALESCER BAGS AND FOUND OK FOR CONTINUED SERVICE. FOUND NO DEFECTS WITH APU OR AIR CONDITIONING SYSTEM. REF AMM 49-10-00 AND 21-10-00.Jul 25, 2011 · N877GA · Doug MD83 · Air Distribution SystemSDR WX0A070899Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJun 30, 2011 · N877GA · Doug MD83 · Emergency LightingSDR WX0A070876Engine · malfunctionedDURING CLIMB, RIGHT ENGINE OIL TEMP BEGAN CLIMBING, FOLLOWED BY OIL QUANTITY FALLING. ENGINE WAS SHUTDOWN IN FLIGHT, OIL TEMP REACHED 199FT. REMOVED AND REPLACED RIGHT ENGINE IAW ALLEGIANT TASK CARD R0807106, ENGINE OPS AND LEAK CHECKS GOOD. AIRCRAFT RETURNMay 26, 2011 · N877GA · Doug MD83 · Engine (Turbine/Turboprop)
Back to N877GA, cancelled Oct 1, 2022