N906UA, cancelled Mar 21, 2013
Service difficulty reports · 32
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N906UA' AND deregistration_id = 'N906UA-2013-03-21' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N906UA' AND deregistration_id = 'N906UA-2013-03-21' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012091405195Door Frame · crackedFWD CARGO DOOR CUTOUT IS CRACKED IN TWO PLACES. FIRST CRACK IS ON AFT SIDE OF FRAME IS CRACKED IN TWO PLACES. FIRST CRACK IS ON AFT SIDE OF FRAME IN RADIUS ADJACENT TO I/B UPPER CORNER OF LWR STOP FITTING, SECOND CRACK IS ON FWD SIDE OF FRAME JUST BELOW UPPESDR UALA2012091405194Structure · damagedA CATEGORY B MAJOR SHEETMETAL REPAIR WAS INSTALLED BETWEEN STA 312 & 330 & BETWEEN STR 20R AND 21R PER SRM REPAIR 31.SDR UALA2008111301969Wire · faultyFLIGHT ATTENDANT NOTICED HOT ODOR AT FWD GALLEY. SMELL WAS ELECTRIC. THEN SPARK OCCURRED FROM COFFEEMARKER GRILL (HOT PLATE) THEN ARC AND PUFF OF SMOKE. FOUND BURNED WIRE ON FORWARD GALLEY COFFEEMAKER. REPLACED COFFEEMAKER. AWAITING SHOP FINDINGS.SDR 2008UALA01969Coffeemaker · faultyFLIGHT ATTENDANT NOTICED HOT SMELL AT FWD GALLEY. SMELL WAS ELECTRIC. THEN SPARK OCCURRED FROM COFFEE MARKER GRILL (HOT PLATE) THEN ARC AND PUFF OF SMOKE.SDR 2008UALA01717Power Supply · inoperativeFLOOR EEL LIGHTS INOP FROM ROW 15 TO AFT GALLEY. REPLACED WET POWER FEEDER.SDR UALA2008111300478Module · malfunctionedCREW REPORTS ON PREFLT, GET NO BELL DURING FIRE TEST. APU HORN IN WHEEL WELL DOES COME ON. FOUND FAULTY AURAL WARNING MODULE. REPLACED AURAL WARNING MODULE.SDR 2008UALA00478Fire Warning · no testCREW REPORTS ON PREFLT, NO BELL DURING FIRE TEST. APU HORN IN WHEEL WELL DOES COME ON.SDR 2008UALA00477Skin · damagedFWD CARGO DOOR DAMAGED BY BELT LOADER. MAJOR REPAIR: REMOVED DAMAGED SKIN. INSTALLED REPAIR DOUBLER.SDR 2007UALA04698Light · inoperativeEEL LIGHTS AT THE AFT SECTION OF THE CABIN INOP. REPLACED LIGHT ASSEMBLYSDR 2007UALA03126Inverter · inoperativeTHREE SEGMENTS OF EEL LIGHTS INOP AFT CABIN AFT GALLEY. REPLACED INVERTER. OPS CHECKS GOOD.SDR 2007UALA01247Door Frame · crackedFWD CARGO DOOR CUT OUT AFT FRAME IS CRACKED IN TWO PLACES. FIRST CRACK IS ON AFT SIDE OF FRAME IN RADIUS ADJACENT TO IB UPPER CORNER OF LOWER STOP FITTING, SECOND CRACK IS ON FWD SIDE OF FRAME JUST BELOW UPPER CORNER IB CORNER OF LOWER STOP FITTING. [SUP 05-SDR 2007UALA01212Frame · damagedFRAME DAMAGED AT BS 908 BETWEEN STRINGERS 20R AND 23R. [SUP 05-16-07] MAJOR REPAIR: ACCOMPLISHED PER UA EVA 70187.SDR 2007UALA01211Skin · damagedSKIN DAMAGED BETWEEN BS 887 & BS 928 & FROM BUT NOT INCLUDING STRINGERS 20R AND 23R. [SUP 05-16-07] REPAIRED PER SRM 53-00-01.SDR 2007UALA00472Skin · damagedFUSELAGE SKIN IS SCRATCHED AND DENTED APPROX 29 INCHES BELOW AFT END OF DOOR 1R OPENING. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR AND ACCMP CORROSION TREATMENT TO SHEETMETAL REPAIR.SDR 2007UALA00466Skin · damagedFUSELAGE SKIN IS SCRATCHED AND DENTED APPROX 29 INCHES BELOW AFT END OF DOOR 1R OPENING. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED DOUBLER, TRIPLER, FILLER AND INTERNAL TEAR STRAP DOUBLERS.SDR 2007UALA00225Feeder Cable · faultyEEL LIGHTS INOPERATIVE AFT OF ROW 15. REPLACED CABLE.SDR 2005UALA01330Attach Fitting · corrodedLEFT HORIZONTAL STABILIZER FWD SPAR LWR ATTACH FITTING CORRODED. MAJOR REPAIR ACP'D PER AAR EA I050309 FOR LUG REWORK AND BUSHING RPLMT'S.SDR 2005UALA01329Attach Fitting · corrodedLEFT HORIZONTAL STABILIZER FWD SPAR UPPER ATTACH LUG CORRODED. MAJOR REPAIR ACP'D PER AAR EA I050309 FOR LUG REWORK AND BUSHING REPLMTS.SDR 2004UALA00499Skin · dentedLEFT FUSE SKIN AND SIDE FRAME DENTED AT BS 178 WL 195. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE, INSTALLED FILLER AND DOUBLER.SDR 2004UALA00496Skin · damagedLEFT EXTERNAL FUSELAGE AFT OF L2 DOOR IS DAMAGED. REPAIR ACCOMPLISHED. INSTALLED DOUBLER/TRIPLER.SDR 2004UALA00497Frame · misinstalledSTATION 178 LT UPPER FRAME WL 243 NO EDGE DISTANCE. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED ANGLE SPLICE REPAIR.SDR 2004UALA00482Shear Web · crackedSTA 194 SHEAR WEB AT STR 17 RT IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED SHEAR WEB.SDR 2004UALA00481Shear Web · crackedSTA 194 SHEAR WEB AT STR 17 LT IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED SHEAR WEB.SDR 2004UALA00471Frame · corrodedSTA 380 FRAME HAS CORROSION FROM STR 28L TO 28R. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2004UALA00449Frame · crackedCABIN BELOW FLOOR LEVEL, BS 616R I/B FRAME CHORD CRACKED AT OVERWING EXIT. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND ANGLE.SDR 2001UALA01614Control Unit · malfunctionedUNSCHEDULED LANDING DUE TO FIRE BELL ACTIVATION. REMOVED AND REPLACED FIRE OVERHEAT DETECTOR CONTROL UNIT AND ENG/APU FIRE CONTROL MODULE. PERFORMED OPERATIONAL TEST AND AIRCRAFT WAS RETURNED TO REVENUE SERVICE.SDR 2000UALA00748Bulkhead · crackedCRACK FOUND ON THE BODY STATION 178 BULKHEAD WEB. SUPPLEMENTAL DATA UPDATE CRACKS REPAIRED PER BOEING SRM 53-10-08.SDR 99UAL900426Oven · dirtyCABIN ODOR EXPERIENCED AT FL 280 IN DESCENT. OVENS AND LIGHTS TURNED OFF. ODOR SUBSIDED BUT STILL LINGERED. *S/D* OVEN UPPER BAFFLE WAS CONTAMINATED WITH MELTED PLASTIC. OVEN WAS REMOVED AND SHIPPED TO THE COMPONENT SHOP. UNIT WAS CLEANED, TESTED AND RETSDR 97UAL900811Sensor · badON GEAR EXTENSION, LEFT MAIN LANDING GEAR RED LIGHT DID NOT EXTINGUISH. *S/D* FOUND LEFT MAIN LANDING GEAR DOWNLOCK SENSOR BAD. REPLACED LEFT MAIN LANDING GEAR DOWNLOCK SENSOR, OPS CHECK OK.SDR 97UAL900322Controller · failedRETURNED TO FIELD. UNABLE TO PRESSURIZE THE CABIN. *S/D* CABIN PRESSURE CONTROLLER FAILED. REPLACED CABIN PRESSURE CONTROLLER, OPS CHECK GOOD.SDR 96UAL900715Light · inoperativeFORWARD GALLEY EMERGENCY ESCAPE PATH LIGHTING INOP. REPLACED FORWARD GALLEY EMERGENCY LIGHT STRIP, CHECKS OK.SDR 96UAL900364Lamp · inoperativeDOOR ONE LEFT EMERGENCY LIGHT INOP. RELAMPED, CHECKS OK.
Back to N906UA, cancelled Mar 21, 2013