N908FR, cancelled Mar 21, 2016
Service difficulty reports · 83
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N908FR' AND deregistration_id = 'N908FR-2016-03-21' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N908FR' AND deregistration_id = 'N908FR-2016-03-21' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200700335Dummy Rail · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED MAIN CABIN FLOOR DUMMY RAIL AT +Y503.2 BETWEEN FR 12 AND 16 CORRODED. REMOVED AND INSTALLED CORRODED DUMMY RAIL IAW SRM 51-42-11, 51-44-11 AND DWG D531 12825.SDR F3LA200700334Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED MAIN CABIN FLOORBEAM AT FR16, +Y254, CORRODED. DETERMINED CORROSION TO BE OUT OF LIMITS IAW SRM 53-11-14. CUT OUT CORRODED AREAS, AND FABRICATED AND INSTALLED FILLER AND REPAIR ANGLES IAW SRM 53-11-14 AND 51-75-12.SDR F3LA200700333Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM NUTPLATE HOLES AT +Y1292 (LT), 4 INCHES FWD OF FR68-69. REMOVED AND REPLACED FLOORBEAM IAW A319 SRM'S 51-74-00, 51-42-11, 53-00-14, 51-44-11, 51-75-12 AND EA A9-53R-12267 (STEPS 1 AND 2).SDR F3LA200700331Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED R2 DOOR FWD GIRT BAR BRACKET CORRODED AROUND ATTACH POINTS. REMOVED AND REPLACED R2 DOOR GIRT BAR BLANKING PLATE IAW AMM 52-11-31-400-005.SDR F3LA200700330Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED R2 DOOR AFT GIRT BAR BRACKET CORRODED AROUND ATTACH POINTS. REMOVED AND REPLACED R2 DOOR AFT BLANKING PLATE IAW AMM 52-11-31-400-005.SDR F3LA200700329Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED R2 GIRT BAR CORRODED. REMOVED AND REPLACED R2 DOOR BLANKING PLATE IAW AMM 52-11-31-400-005.SDR F3LA200700327Sill · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON L2 DOOR SILL AT AFT INBD END AT NUT PLATE HOLES, APPROX 1-4 INCHES FWD OF FR 68. DETERMINED DAMAGE TO BE OUT OF LIMITS IAW SRM 53-41-14. REMOVED AND REPLACED L2 DOOR SILL IAW SRM 52-42-11.SDR F3LA200700326Shear Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED SHEAR PLATE AT FR 69-70, -Y1732, CORRODED. REMOVED AND REPLACED SHEAR PLATE IAW SRM 51-42-11, PARA 6,7,14, AND EA A9-53R-12267.SDR F3LA200700323Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 221FF. REMOVED AND REPLACED FLOOR PANEL 221FF IAW AMM 53-12-12-PB401, AMM 53-12-12-400-001, AND FRONTIER WORK CARD CP753-12.SDR F3LA200700352Floor Support · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON NUT PLATE HOLES OF FLOORBEAM -Y1292 BETWEEN FR 66 AND 70. REMOVED AND REPLACED FLOORBEAM -Y1292 IAW SRM 51-42-11.SDR F3LA200700345Floorboard · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED BOTTOM OF FLOORBOARD 261FF CORRODED. REMOVED AND REPLACED FLOOR 261FF IAW AMM 53-32-12-400-002.SDR F3LA200700324Splice · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 221LF SPLICE PLATE CORRODED, AFT END. REPLACED AFT SPLICE PLATE ON FLOOR PANEL 221LF IAW AMM 53-12-12-PB401 AND WORK CARD CP753-12.SDR F3LA200700322Plate · looseDURING C4/S1 CHECK, INSPECTION REPORTED SHEARED RIVETS ON SILL PLATE AT FRAME 69, -Y1292 FLOORBEAM. REMOVED SHEARED RIVETS ON WEB PLATE AFT OF FR68 FLOORBEAM AT -Y1292 IAW SRM 51-42-11, PARA. 6. INSTALLED LOCK FASTENER THROUGH WEB PLATE AFT OF FR68 THAT ATTASDR F3LA200700321Plate · looseDURING C4/S1 CHECK, INSPECTION REPORTED SHEARED RIVETS ON SILL PLATE AT FRAME 68, AFT AND OTBD OF +Y1292 BEAM. REMOVED SHEARED RIVETS THAT CONNECT PLATE TO FLOOR BEAM IAW SRM 51-42-11. REPLACED THE FOUR SHEARED BLIND RIVETS THAT ATTACH THE SHEAR PLATES TO THSDR F3LA200700320Floorboard · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED BOTTOM OF FLOORBOARD 222FF CORRODED. REMOVED AND REPLACED FLOOR PANEL 222FF IAW MM 53-12-12-PB401 AND 53-12-12-400-001.SDR F3LA200700319Floorboard · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED BOTTOM OF FLOORBOARD 221FF CORRODED. REMOVED AND REPLACED FLOOR PANEL 221FF IAW MM 53-12-12-401 AND 53-12-12-400-001.SDR F3LA200700332Fitting · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR FITTING UNDER CABINET SECTION OF AFT GALLEY CORRODED. REMOVED AND REPLACED CORRODED FITTING IAW AMM 25-33-41-400-002.SDR F3LA200700355Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED SCREWS RUSTY AROUND THE OUTSIDE OF THE FIRST OFFICER'S RT AFT FIXED COCKPIT WINDOW. REMOVED FIXED WINDOW IAW AMM 56-11-12-000-001. INSTALLED FIXED WINDOW IAW AMM 56-11-12-000-002. PERFORMED OPS TEST OF WINDOW HEAT SYSSDR F3LA200700318Structure · crackedDURING C4/S1 CHECK, INSPECTION REPORTED CRACK EMANATING FROM RT PYLON (OTBD UPPER, ABOVE TR) SCREW HOLE. CUT OUT DAMAGED AREA, FABRICATED REPAIR FILLER AND SPLICE, AND INSTALLED REPAIR IAW SRM 54-52-11, REPAIR E, STEP 2C; 54-52-12, FIG. 205; AND EA A9-54R-122SDR F3LA200700359Battery · failedDURING C4/S1 CHECK, INSPECTION REPORTED AFT EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED EMERGENCY BATTERY FROM POWER SUPPLY UNIT 13WL IAW AMM 33-51-38-000-002. INSTALLED SERVICEABLE BATTERY IAW AMM 33-51-38-400-002. PERFORMED OPERATIONAL TEST OF SDR F3LA200700356Battery · failedDURING C4/S1 CHECK, INSPECTION REPORTED RT OVERWING EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED EMERGENCY BATTERY FROM POWER SUPPLY UNIT 12WL IAW AMM 33-51-38-000-002. INSTALLED SERVICEABLE BATTERY IAW AMM 33-51-38-400-002. PERFORMED OPERATIONAL SDR F3LA200700358Battery · failedDURING C4/S1 CHECK, INSPECTION REPORTED FWD LT EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED EMERGENCY BATTERY FROM POWER SUPPLY UNIT 10WL IAW AMM 33-51-38-000-002. INSTALLED SERVICEABLE BATTERY IAW AMM 33-51-38-400-002. PERFORMED OPERATIONAL TEST SDR F3LA200700357Battery · failedDURING C4/S1 CHECK, INSPECTION REPORTED LT OVERWING EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED EMERGENCY BATTERY FROM POWER SUPPLY UNIT 11WL IAW AMM 33-51-38-000-002. INSTALLED SERVICEABLE BATTERY IAW AMM 33-51-38-400-002. PERFORMED OPERATIONAL SDR F3LA200700045Control Unit · inoperativeFLIGHT CREW REPORTED ECAM L/G LGCIU2 FAULT ON APPROACH. PERFORMED GO-AROUND AND AIRCRAFT LANDED WITHOUT INCIDENT. REPLACED NR 2 LANDING GEAR CONTROL INTERFACE UNIT (LGCIU) IAW 32-31-71-400-001 AND TESTED GOOD.SDR F3LA200600015Stowage Box · no testDURING C-3 CHECK, CAPTAINS O2 MASK FAILED PRESS-TO-TEST. REPLACED CAPTAINS O2 BOX ASSY PER AMM 35-12-41-000-001, 35-12-41-406-001 AND 35-12-41-710-001. OPS CHECKED GOOD.SDR F3LA200600013Frame · misdrilledDURING C-3 CHECK, INSPECTION REPORTED RIVET HOLE AT FRAME FS 54, STR 4L, FOUND MISDRILLED. REPAIRED PER EA A9-53R-11345.SDR F3LA20060013Frame · damagedDURING C-3 CHECK, INSPECTION REPORTED RIVET HOLE AT FRAME FS 54, STR 4L, FOUND MISDRILLED. REPAIRED PER EA A9-53R-11345.SDR F3LA200600012Floorbeam · corrodedDURING C3 CHECK, INSPECTION REPORTED SURFACE CORROSION ON FLOORBEAM AFT OF FRAME 66 AND FORWARD OF FRAME 68 (10" INBD OF L2 DOOR CUTOUT) AT OR NEAR CLIPNUTS AT FS 66. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11 AND EA A9-53R-11343.SDR F3LA20060012Floorbeam · corrodedDURING C3 CHECK, INSPECTION REPORTED SURFACE CORROSION ON FLOORBEAM AFT OF FRAME 66 AND FORWARD OF FRAME 68 (10" INBD OF L2 DOOR CUTOUT) AT OR NEAR CLIPNUTS AT FS 66. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11 AND EA A9-53R-11343.SDR F3LA200600016Skin · damagedDURING C-3 CHECK, INSPECTION REPORTED RT WING OTBD FLAP L/E BETWEEN NR 3 AND 4 FAIRINGS DAMAGED. CUT OUT DAMAGED SKIN PER SRM 57-53-00, PAGE 213. FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 57-53-00 AND EA A9-57R-11353.SDR F3LA200600014Stringer · damagedDURING C-3 CHECK, INSPECTION REPORTED STR 4L DAMAGED AT FRAME 54. CUT OUT DAMAGED STRINGER SECTION, FABRICATED AND INSTALLED REPLACEMENT SECTION PER SRM 53-00-13, PAGE 201.SDR F3LA200500034Check Valve · brokenFLIGHT CREW REPORTED STRONG, SMOKY/BURNING ELECTRICAL FUMES ON DESCENT AND WAS STRONGER IN AFT CABIN. REPLACED RT PACK CHECK VALVE (19HM) PER AMM 21-63-42, PB 401. NO LEAKS OR ODOR NOTED.SDR F3LA200200172Cover · out of adjustABORTED TAKEOFF. FLIGHT CREW REPORTED LT OVERWING EMERGENCY EXIT OPEN INDICATION AT 100 KTS. ADJUSTED LT OVERWING EXIT DOOR HANDLE COVER FLAP. TESTED PER MM 25-23-47-401, TASK 25-23-47-991-017, FIG 402, AND CHECKED OKAY.