Service difficulty reports · 85
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR DALA2020030601662Battery Pack · dischargedFOUND LWR EMERGENCY PATH LIGHTS ON BOTH FWD DOORS INOP. R/R EMERGENCY LIGHT SLID AND BATTERY PACK B5-211 PER MD90 AM;33 -51. OPS CHECK GOOD . A/C OK FOR SVC. (6954427)SDR DALA2019121607317Battery · inoperativeROW 25 EMERGENCY LIGHT OUT C/A R/R BATTERY ASSY PER MD90 AMM 33-51. OPS CHECK IS GOOD AT THIS TIME. (6615064)SDR DALA2019112106793Unknown · odorWHILE PULLING INTO THE GATE. AFTER LANDING IN SYRACUSE WE ACTIVATED APU AIR. THE FA IN THE AFT CABIN CHIMED THE COCKPIT TO REPORT FUMES THAT SMELLED LIKE RUBBER. AS PASSENGERS DEPLANED THE FORWARD FA'S REPORTED FUMES. I WALKED OUTSIDE TO SEE IF THE FUMES WERE
See all 85 reports