N923TS, cancelled Jan 29, 2018
Service difficulty reports · 54
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N923TS' AND deregistration_id = 'N923TS-2018-01-29' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N923TS' AND deregistration_id = 'N923TS-2018-01-29' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA089902Filter · dirtyNR 3 ENGINE OIL BYPASS LIGHT ILLUMINATED ON TAKEOFF ROLL. REPLACED NR 3 OIL FILTER. RAN ENGINE PER MM 71-00. LIGHT WENT OUT, LEAK CHECKS OK. FILLED NR 3 OIL TANK. CHECKS OK. (M)SDR USAA069965Actuator · failedFLT 6051 - BOS-LGA - AIR RETURNED TO BOS ON TAKEOFF, INBOARD FLAP ASYMMETRY TRIP. NR 5 L/E SLAT LIGHT SHOWED AMBER. ACCOMP ASYMMETRICAL FLAP ABNORMAL CHECKLIST, RETURNED TO BOS. ALL FLAPS EXTENDED ON LANDING. FOUND RIGHT INBOARD FLAP TRANSMITTER STICKING OSDR USAA069947Hose · leakingFLT 6540 - DCA-LGA - HYDRAULIC SYSTEM 'A' FLUID DEPLETED TO ZERO. NORMAL LANDING. FOUND NR 1 ENGINE HYDRAULIC PUMP CASE DRAIN LINE FROM FIREWALL TO CASE DRAIN FILTER LEAKING. REPLACED LINE. REPLACED NR 1 AND NR 2 'A' SYSTEM CASE DRAIN FILTERS. (M)SDR USAA059905O-Ring · leakingFLT 6470 - DCA-LGA - NR 1 ENGINE LOW OIL PRESSURE LIGHT ILLUMINATED AFTER TAKEOFF. ON RUNUP, FOUND OIL LINE TO FUEL OIL COOLER LEAKING. REPLACED O-RING SEAL. RAN ENGINE, OPS CHECK OK MM REF 79-33-0. (M)SDR USAA059902Connector · looseDCA-LGA - FLT 6540 - DCA-LGA - FORWARD LAVATORY SMOKE DETECTOR ALARM WENT OFF DURING TAKEOFF CLIMB. THEN WENT OFF AFTER F/A PLAYED WITH IT. RESEATED CONNECTOR ON DETECTOR, CHECKS OK. (M)SDR USAA049901Light · inoperativeOVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE AT ROW 3. REPLACED EMERGENCY EXIT LIGHT BASE ASSEMBLY, OPERATIONAL CHECK NORMAL. (M)SDR USAA029914Battery Pack · dischargedFLT 6541 - LGA-DCA - FOUND ON L/S CHECK, LEFT OVERWING EXTERIOR CENTER EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY PACK, CHECKS OK. (M)SDR TAOA109805Engine · failedABORTED TAKEOFF ROLL AT APPROX 30 KNOTS DUE TO NR 1 ENGINE LOSS OF POWER. NR 1 ENGINE TURBINE FAILED WITH METAL IN THE TAIL PIPE. NR 1 ENGINE REPLACED. (M)SDR TAOA089804Latch · out of adjustDURING TRAINING RIGHT FORWARD OVERWING EMERGENCY EXIT WOULD NOT OPEN. ADJUSTED FORWARD UPPER LATCH FITTING ON RIGHT FORWARD EMERGENCY EXIT DOOR PER MM 52-21-0. CHECKED HATCH FOR FLUSHNESS AND OPENING AND CLOSING FORCE PER MM 52-21-0. OPERATIONAL CHECK NORMASDR TAOA069809Module · leakingDCA/LGA - FLT 6431 - HYDRAULIC SYSTEM 'A' FAILURE WHILE ON TAXIWAY PRIOR TO DEPARTURE. REPLACED LEAKING SYSTEM 'A' ELEVATOR FLIGHT CONTROL MODULE PER MM 27-30-91, EXAMINED SYSTEM 'A' CASE DRAIN FILTERS. REPLACED CASE DRAIN FILTERS PER MM 29-11-41. RAN ENGINSDR TAOA059813Light · inoperativeFLT 6491 - LGA-BOS - COCKPIT EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY OPERATIONAL CHECK NORMAL. (M)SDR TAOA059808Controller · failedFLT 6150 - DCA-LGA - LEFT PACK OVERHEATED ON TAKEOFF ROLL, ABORTED TAKEOFF WHEN PACK TRIPPED AND SMOKE FILLED CABIN AND COCKPIT. REPLACED LEFT PACK CONTROLLER, OPERATIONAL CHECK NORMAL IAW MM 21-51-91. (M)SDR TAOA039808Battery Pack · dischargedFLT 6530 - OVERNIGHT LGA, L/S CHECK, AFT SECTION OF EMERGENCY PATH LIGHTING INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL. (M)SDR TAOA129706Fuel Pump · failedFLT 6490 - DCA-LGA - NR 2 ENGINE FAILURE ON CLIMB-OUT AT ALTITUDE OF 600 FEET. FLIGHT RETURNED TO DCA, EMERGENCY DECLARED. FOUND NR 2 ENGINE DRIVEN FUEL PUMP FAILED INTERNALLY. REPLACED NR 2 ENGINE DRIVEN FUEL PUMP. ENGINE RUN UP CONFIRMED FUEL PUMP FAILURSDR TAOA089713Pressure Switch · failedLGA/DCA - FLT 6421 - ON TAKEOFF, THE NR 1 LOW OIL PRESSURE LIGHT ILLUMINATED. FOLLOWED ABNORMAL PROCEDURES, OIL PRESSURE REMAINED NORMAL. REPLACED NR 1 ENGINE OIL FILTER AND NR 1 OIL BYPASS PRESSURE SWITCH. RAN ENGINE NR 1 OIL PRESSURE/BYPASS LIGHT OPERATIOSDR TAOA089706Smoke Detector · intermittentFLT 6681 - BUF-LGA - ELECTRICAL SMELL COMING FROM FORWARD LAVATORY, SMOKE DETECTOR SOUNDED. INSPECTED ELECTRICAL SYSTEM IN FORWARD LAVATORY, NO DISCREPANCIES FOUND. REPLACED FORWARD LAVATORY SMOKE DETECTOR. OPERATIONAL CHECK NORMAL. (M)SDR TAOA079715Light · inoperativeFLT 6181- BOS-LGA - OVERHEAD EMERGENCY LIGHT AT ROWS 9 AND 10 INOPERATIVE. REPLACED LIGHT ASSEMBLY, OPERATIONAL CHECK NORMAL. (M)SDR TAOA079710Pt7 Sense Line · looseFLT 6431 - ABORTED TAKEOFF, UNABLE TO GET TAKEOFF POWER ON NR 3 ENGINE. HAD THROTTLE TO FIREWALL AND ONLY 1.88 EPR. ABORTED TAKEOFF AT 80 KNOTS. SECURED B-NUT ON EPR TRANSMITTER TO PT7 LINE. RUN-UP TAKEOFF CHECK 36 DEGREES CELSIUS (BARO 29.90, TAKEOFF EPR SDR TAOA069703Battery Pack · dischargedON OVERNIGHT INSPECTION AT LGA OFF FLT 6540 DCA-LGA, THE RIGHT OVERWING EMERGENCY EXIT LIGHT SIGN WAS FOUND INOPERATIVE. REPLACED RIGHT OVERWING EMERGENCY EXIT LIGHT BATTERY PACK. OPERATIONAL CHECKED OK MM 33-50. (M)SDR TAOA059713Battery Pack · dischargedDCA/LGA - FLT 6530 - DURING L/S CHECK, FOUND ROW 30 OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. (X)SDR TAOA049714Battery Pack · dischargedFLT 6530 - DCA-LGA - RIGHT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECKS NORMAL IAW 33-50. (M)SDR TAOA049708Battery Pack · dischargedFLT 6530 - DCA-LGA - RIGHT OVERWING EMERGENCY EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL IAW MM 33-50-0. (M)SDR TAOA049706Battery Pack · dischargedFLT 6470 - DCA-LGA - CENTER OVERHEAD EXIT SIGN FLICKERS. REPLACED BATTERY PACK, OPERATIONAL CHECKS NORMAL IAW MM 33-50-0. (M)SDR TAOA049705Battery Pack · dischargedFLT 6470 - DCA-LGA - OVERWING EMERGENCY EXIT SIGN LIGHTS OUT, RIGHT SIDE IN CABIN. REPLACED BATTERY PACK, OPERATIONAL CHECKS NORMAL IAW MM 33-50-0. (M)SDR TAOA039714Battery Pack · dischargedFLIGHT 6141 - BOS-LGA, RIGHT OVERWING EMERGENCY EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL IAW MM 33-50. (M)SDR TAOA039706Battery Pack · dischargedFLT 6530 - DCA-LGA - FOUND ON OVERNIGHT L/S, EMERGENCY EXIT LIGHT AT ROW 4 OVERHEAD INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK NORMAL IAW MM 33-50-00. (M)SDR TAOA029708Battery Pack · dischargedFOUND ON LGA OVERNIGHT A2 CHECK, OVERWING AISLE EMERGENCY EXIT SIGNS INOPERATIVE. REPLACED BATTERY PACK AND CHARGER UNIT. OPERATIONAL CHECK NORMAL. (X)SDR TAOA029702Battery Pack · dischargedDCA/LGA - FLT 6540 - ROW 17 DEF SIDEWALL EMERGENCY EXIT LAMP INOPERATIVE. REPLACED BATTERY PACK. (X)SDR TAOA029701Battery Pack · dischargedDCA/LGA - FLT 6540 - ROW DEF CEILING EMERGENCY EXIT LAMP INOPERATIVE. REPLACED BATTERY PACK. (X)SDR TAOA019716Battery · dischargedEMERGENCY EXIT LIGHT INOPERATIVE AT OVERWING RIGHT SIDE AT AISLE CEILING. REPLACED BATTERY CARTIDGE. (M)SDR TAOA019711Battery Pack · dischargedFLT 6541 - DCA - ON OVERNIGHT INSPECTION, THE EMERGENCY EXIT LGIHTIN CEILING AT ROW 17 WAS FOUND INOPERATIVE. REPLACED BATTERY PACK, OPERATION CHECKED OK. (M)SDR TAOA019706Pack · malfunctionFLT 6461 - LGA-DCA - LEFT AIRCRAFT PACK FAILED IN FLIGHT, OVERHEATED, SMOKE IN CABIN, SHUTDOWN PACK. OPERATED BOTH PACKS THROUGH ALL TEMPERATURE SETTINGS. PRESSURIZED AND UNPRESSURIZED, COULD NOT DUPLICATE CONDITION. OPERATIONAL CHECK NORMAL PER MM 21-11 ANSDR TAOA129612Warning Lights · illuminatedAFTER TAKEOFF LEADING EDGE AMBER LIGHTS WOULD NOT EXTINGUISH, RETURNED TO LGA AND LANDED FOR REPAIRS. INSPECTED ALL LEADING EDGE DEVICES AND SWITCHES, ALL CHECK OK. OPERATED FLAPS SEVERAL TIMES AND COULD NOT DUPLICATE PROBLEM, FLAPS AND LEADING EDGE DEVICES SDR TAOA119605Battery Pack · dischargedEMERGENCY EXIT CEILING LIGHT AT ROW 17 INOP. REPLACED BATTERY PACK OPERATION CHECK OK. (M)SDR TAOA119603Battery Pack · dischargedON THE OVERNIGHT CHECK, THE RIGHT OVERWING EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECKED OK. (M)SDR TAOA119601Fuse · blownL-1 AND R-1 EMERGENCY EXIT IDENTIFIER LIGHTS INOP. REPLACED FUSE IN FORWARD BATTERY PACK, OPS CHECK OK. (M)SDR TAOA109615Rib · crackedAD NR 94-07-08 INSPECTION OF THE LEFT SIDE BL 70.5 WING RIB UPPER CHORD REVEALED CRACKS IN THE FORWARD TWO FASTENER HOLES COMMON TO THE BS 760.95 FRAME. THE CRACK EXTENDS SLIGHTLY INTO THE HORIZONTAL FLANGE. CORROSION WAS ALSO DETECTED ON THE INNER SURFACE OSDR TAOA069616Battery Pack · dischargedOVERWING AISLE EMERGENCY EXIT SIGNS INOP. REPLACED BATTERY PACK CHECKS OK AS PER MM CHAPTER 33-50. (M)SDR TAOA069603Battery Pack · dischargedFLT 6540 - DCA-LGA - FOUND ON OVERNIGHT CHECK, EMERGENCY EXIT LAMP AT ROW 28 CEILING INOP. REPLACED BATTERY PACK, OPS CEHCKED OK, PER MM 33-50-00. (M)SDR TAOA029602Battery Pack · dischargedEMERGENCY EXIT SIGN AT ROW 16 INOP. REPLACED BATTERY PACK. OPERATIONAL CHECK OK. (M)SDR TAOA129506Battery Pack · dischargedEMREGENCY EXIT SIGN AT ROW 16D INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK OK. (X)SDR TAOA119501Battery Pack · dischargedAISLE OVERHEAD EMERGENCY SIGN AT ROW 15 INOP. REPLACED BATTERY PACK. OPERATIONAL CHECK OK. (M)SDR TAOA109517Battery Charger · malfunctionedEMERGENCY LIGHT AT ROW 3 STAYS ON AFTER TEST. REPLACED BATTERY PACK CHARGER. OPERATIONAL CHECK OK. (M)SDR TAOA099513Eel · missingTWO 'E' PATH LIGHT ASSEMBLIES MISSING AT ROW 10. REPLACED LIGHT ASSEMBLIES. OPERATIONAL CHECK OK. (M)SDR TA0A099511Eel Lamp · failedAISLE PATH LIGHTING HAS BULB BURNED OUT AT ROW 17. RELAMPED ROW 17 AISLE PATH LIGHT BULB. OPS CHECKS OK. (M)SDR TAOA089509Eel Batt Pack · dischargedOVERHEAD EMERGENCY LIGHT AT ROW 16 INOP. REPLACED BATTERY PACK OPERATIONAL CHECK OK. (M)SDR TAOA079505Eel Battery Pack · dischargedEMERGENCY LIGHTS AT ROW 15 CEILING AND ROW 21 CEILING INOPERABLE. REPLACED BATTERY PACK FOR ROW 15 AND ROW 21 CEILING EMERGENCY LIGHTS - CKS OK. S/N ROW 15 - 11725. S/N ROW 21 - T3921. (X)SDR TAOA079502Smoke Detector · malfunctionedFORWARD LAVATORY SMOKE DETECTOR WILL NOT SHUT OFF. REPLACED FORWARD LAVATORY SMOKE DETECTOR. OPS CHECKED OK. (M)SDR TAOA049501Dn Lock Switch · failedNOSE GEAR UNSAFE LIGHT REMAINED ILLUMINATED WHEN GEAR SELECTED DOWN. ALL GREEN WERE ILLUMINATED WHEN DOWN SELECTED. NOSE GEAR VISUALLY CONFIRMED DOWN. ABNORMAL PROCEDURES COMPLETED. REPLACED LOCK SWTICH PER MM 32-61-71. OPS CHECK OK. (W)SDR 95ZZZW352Pack · malfunctionedRIGHT PACK OVERHEATED AFTER TAKEOFF. PACK WENT TO 160 CELSIUS. CREW REPORTED SMOKE IN CABIN. PACK SHUTOFF. CHECKED ALL RT PACK DUCTS, FLOW CONTROL VALVES AND SENSE LINES FOR LEAK AND SECURITY, ALL OK. CHECKED RAM AIR INLETS AND INLET DOOR, FOUND OK. LUBE
Back to N923TS, cancelled Jan 29, 2018