SDR 95ZZZW352

Service difficulty report · Pack · Boeing 727225

Difficulty date
March 17, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N923TS
Make and model
Boeing 727225
Aircraft serial
20441
Part
Pack
Condition
Malfunctioned
Location
Rt
Stage of operation
CL
Nature of condition
B
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT PACK OVERHEATED AFTER TAKEOFF. PACK WENT TO 160 CELSIUS. CREW REPORTED SMOKE IN CABIN. PACK SHUTOFF. CHECKED ALL RT PACK DUCTS, FLOW CONTROL VALVES AND SENSE LINES FOR LEAK AND SECURITY, ALL OK. CHECKED RAM AIR INLETS AND INLET DOOR, FOUND OK. LUBED RAM AIR DOORS, CLEANED ELECTRICAL CONNECTORS AT RT MIX VALVE AND ACM OVERHEAT SWITCHES, AND RE-TORQUED SENSOR LINES PRECAUTIONARY. OPERATED PACKS WITH LEVER LATCH CIRCUIT BREAKER PULLED, FLAPS 15. SYSTEM CHECKED OK PER MM 21-55-0. (W)