N935UA, cancelled Jul 14, 2010
Service difficulty reports · 45
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N935UA' AND deregistration_id = 'N935UA-2010-07-14' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N935UA' AND deregistration_id = 'N935UA-2010-07-14' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009031000696Skin · damagedFOUND HOLE IN FUSELAGE APPROXIMATELY 36 INCHES AFT OF AFT CARGO DOOR. MAJOR REPAIR ACCOMPLISHED. HOLE MEASURES APPROX 2 1-8" X 1 1-4", WITH A SCRATCH LEADING TO HOLE APPROX 9 INCHES LONG. CUT OUT DAMAGE AND MFG DOUBLER AND STRAP. PRIMED BOTH AND AREA. NO SDR UALA2009030300721Skin · damagedFOUND HOLE IN FUSELAGE APPROXIMATELY 36 INCHES AFT OF AFT CARGO DOOR. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE, MFG DOUBLER AND STRAP. PRIMED BOTH AND AREA. INSTALLED DOUBLER REPAIR.SDR UALA2009030300696Skin · damagedFOUND HOLE IN FUSELAGE APPROXIMATELY 36 INCHES AFT OF AFT CARGO DOOR. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE, MFG DOUBLER AND STRAP. PRIMED BOTH AND AREA.SDR 2008UALA06471Controller · malfunctionedPRESSURIZATION PROBLEM. FLIGHT DIVERTED.
SDR UALA2008111306359Duct · crackedWING BODY OVERHEAT LIGHT. RT FL DUE TO INCLEMENT WEATHER AT PLANNED DESTINATION. FAULT RECURRED ON NEXT FLIGHT OUT. PERFORMED TROUBLE SHOOTING, INTERROGATED M237 MODULE AND FOUND CODE 24 INDICATING LT A-C BAY OVERHEAT. INSPECTED LOOP AND COMPARTMENT. FOUND LASDR 2008UALA06359Warning System · activatedWING BODY OVERHEAT LIGHT. RTFL DUE TO INCLEMENT WEATHER AT PLANNED DESTINATION. FAULT RECURRED ON NEXT FLIGHT OUT.SDR 2008UALA04067Bearing · failedNR 1 ENGINE COMPRESSOR STALL. RTFL. FOUND FAILURE OF NR 4 BEARING. CHANGED ENGINES.SDR 2008UALA02781Wire · shortedBURNING ODOR NOTED THROUGHOUT THE ACFT. ODOR DISSIPATED WHEN RECIC FAN WAS TURNED OFF. AFTER EXTENSIVE TROUBLE SHOOTING AND PART REPLACEMENT REPAIRED WIRE W090-018-24 REF WD21-61-01 BETWEEN CABIN TEMP CONTROLLER AND CABIN TEMP SELECTOR. FOUND WIRE SHORTED TOSDR 2008UALA00712Lamp · inoperativeNR 1 AND NR 2 ENGINE FIRE HANDLES EACH HAVE ONE BULB BURNED OUT. REPLACED FIRE HANDLE BULBS.
SDR 2008UALA00249Slide · out of positionDOOR 1L SLIDE PACK IS LAYING ON JET BRIDGE, NOT SECURED TO AIRCRAFT. REINSTALLED SLIDE PACK.
SDR 2007UALA04131Indicator · malfunctionedFLAP SPLIT INDICATED BY .5 NEEDLE WIDTH. NO ROLL TENDENCY. EACH TIME LOOKS LIKE RIGHT NEEDLE LAGGED BY .5 NEEDLE WIDTH AND THEN CATCHES UP WITH LEFT NEEDLE. CYCLED FLAP POSITION INDICATOR C-B AND DID GET NEEDLES TO PAIR UP. SUSPECT POSITION INDICATOR FAULTSDR 2007UALA02753Structure · dentedCREW REPORTS DENT IN RT HORIZONTAL STABILIZER LEADING EDGE. [08-17-07] MAJOR REPAIR: PER UA EVA-70388 INTERM REPAIR MADE.SDR 2007UALA01049Coffeemaker · contaminatedBURNING PLASTIC ODOR REPORTED BY CREW FROM THE FIRST CLASS GALLEY. CAUSED BY FOUND PLASTIC MELTED ON COFFEE BURNER. CLEANED BURNER.SDR 2006UALA02281Hydraulic System · reads lowSYSTEM-A HYDRAULIC SHOWING 20 PERCENT - AFTER CLIMBING TO 24K FEET, GOT SYSTEM-A, ENGINE 1, LOW PRESSURE LIGHT ILLUMINATED WITH HYDRAULIC QUANTITY READING OF 20 PERCENT. FOUND HYDRO LINES FOUND LEAKING. REPLACED LEAKING LINES AND SERVICED HYDRO SYS "A".SDR 2006UALA01035Fitting · corrodedRT HORIZONTAL STA FWD UPPER LUG IS CORRODED ON AFT FACE LWR EDGE OF SPOT FACE.SDR 2006UALA01033Bulkhead · damagedDAMAGE WAS FOUND ON THE FORWARD SIDE OF THE STA 1016 AFT PRESSURE BULKHEAD WEB ADJACENT TO THE WIRING BUNDLE FEED THRU AT LBL 2.5.SDR 2006UALA01032Door Frame · crackedAFT ENTRY DOOR ENTRYWAY FWD LOWER CORNER IS CRACKED.SDR 2006UALA01031Fitting · damagedLT MLG OTBD BEAM FITTING NR 4 HOLE REQUIRES FREEZE PLUG.SDR 2006UALA01030Fitting · tool damageRT MLG OTBD FITTING HAS TOOLING DAMAGE ON UPPER EDGE.SDR 2006UALA01016Crease Beam · corrodedCABIN FLOOR RT CREASE BEAM IS CORRODED BEYOND REPAIR BS 289-341 RBL 52-61, WL 208.SDR 2006UALA01015Strap · corrodedCABIN FLOOR RH CREASE BEAM IB CHORD VERT FLG IB TAPERED STOP IS CORRODED BEYOND REPAIR BS 296, RBL54, WL209. REMOVED AND REPLACED THE STRAP.SDR 2006UALA01014Fitting · crackedAFT CARGO DOOR HAS POSSIBLE CRACK ON LOWER T-CHORD STOP FITTING AROUND MOST INBOARD FASTENER.SDR 2006UALA00956Frame · crackedFRAME AT STA 787 HAS CRACK AT RIVET LOCATED BETWEEN STR 8L AND 9L.SDR 2006UALA00945Frame · crackedCABIN FRAME CRACKED BS 727B STR 8L & BS 747 STR 8R AT PSU FRAME RAIL ATTACH.SDR 2006UALA00944Frame · crackedCABIN FRAME CRACKED AT BS 400 STR 8L, BS 440 STR 8L AT PSU RAIL ATTACH.SDR 2006UALA00935Intercostal · crackedFWD CABIN FRAME INTERCOSTAL CRACKED STA 302 STR 4L.SDR 2006UALA00941Frame · crackedBODY STATIONS FRAMES ARE CRACKED, STA 380 STR 8R, STA 440 STR 8R, STA 867 STR 8R AND STA 827 STR 8L.SDR 2006UALA00937Frame · crackedFRAMES CRACKED AT STA 787 STR 8R, STA 907 STR 8L AND STA 907 AT STR 8R.SDR 2005UALA00245Overheat Loop · malfunctionedSHUT DOWN NR 2 ENG DUE TO OVERHEAT INDICATION. CREW REPORTED NR 2 ENG OVERHEAT LIGHT CAME ON WITH NO ABNORMAL ENGINE INDICATION. OVERHEAT LIGHT STAYED ON AFTER THE CHECKLIST. CREW SHUT DOWN NR 2 ENGINE. OVERHEAT LIGHT WENT OUT. UPON ARRIVAL AT THE GATE BOTHSDR 2004UALA00831Wire · damagedEEL LIGHTS INOP IN AFT CABIN FROM ROWS 15 TO AFT GALLEY. *S/D* REPLACED EEL TRACK FEEDER CABLE AND POWER LEAD CABLE FROM SIDEWALL.SDR 2002UALA01712Light · inoperativeAFT CABIN EMERGENCY EXIT LIGHTING IS INOPERATIVE. REPLACED POWER STRIP.SDR 2002UALA01478Wire Harness · disconnectedCREW REPORTS DURING SETUP THAT THE EMERGENCY ELECTRICAL LIGHTING (EEL) LIGHTS BETWEEN ROWS 10-20 WERE INOPERATIVE. FEEDER CABLE AT ROW 14 WAS DISCONNECTED. FEEDER CABLE WAS RECONNECTED AND SECURED.SDR 2002UALA00854Frame · crackedSTATION 178 BULKHEAD RIGHT HAND CHORD CRACKED AT WL 207 AREA. MAJOR REPAIR ACCOMPLISHED. CHORD ANGLE SPLICE, VERTICAL WEB AND EXTERNAL DOUBLER REPAIRS.SDR 2002UALA00853Frame · crackedRIGHT HAND FORWARD NOSE BODY STATION 188 FRAME CRACKED. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2002UALA00798Skin · dentedTWO DENTS IN RIGHT SIDE FUSELAGE AT 4 O'CLOCK AT FIRST CIRCUMFERENTIAL AFT OF RADOME BULKHEAD STA 188, STRINGER 20 RIGHT. MAJOR REPAIR ACCOMPLISHED. EXTERNAL DOUBLER INSTALLED.SDR 2002UALA00797Frame · crackedCABIN FRAME STATION 616R BELOW FLOOR FORWARD OF OVERWING EXIT IS CRACKED (FRAME INNER CHORD). MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED FRAME WEB. MANUFACTURED AND INSTALLED NEW WEB SECTION AND SPLICE DOUBLER.SDR 2002UALA00775Bulkhead · crackedSTATION 178 BULKHEAD CRACKED AT RBL 517 INBOARD SIDE LOWER ANTENNA. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2002UALA00771Skin · damagedLEFT HAND FUSELAGE AT APPROXIMATELY STATION 360 AND STRINGER 16L HAS GOUGE AND DENT. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2001UALA02124Indicator · failedABORTED TAKEOFF AT 120 KNOTS DUE TO INOPERATIVE FIRST OFFICER'S SPEED INDICATOR.SDR 2001UALA00151Compressor · failedNR 2 ENGINE FLAME-OUT. *S/D* FOUND N2 ROTATION FROZEN. THE ENGINE WAS REPLACED.SDR 2000UALA00724Access Panel · leakingSUSPECTED FUEL LEAK. SUPPLEMENTAL DATA UPDATE FOUND 2 SCREWS MISSING AND DOME NUTS STRIPPED ON ACCESS PLATE 8117L. REPLACED MISSING SCREWS AND STRIPPED DOME NUTS.SDR 99UAL900072Sensor · out of adjustFORWARD CARGO DOOR WARNING LIGHT. *S/D* MECHANIC SUSPECTS FOD IN THE FORWARD PIT MAY HAVE CAUSED INDICATION PROBLEM. ADJUSTED DOOR SENSOR TARGET TO CORRECT POSITION. OPERATIONS CHECK ACCOMPLISHED ON DOOR WARNING SYSTEM CHECKS GOOD.SDR 97UAL900241Light · inoperativeEEL TRACK LIGHT AT FORWARD GALLEY INOPERABLE ON TEST. REPLACED LIGHT ASSEMBLY. OPS CHECK GOOD.SDR 97UAL900209Light · inoperativeFLOOR EEL LIGHT STRIP PARTIALLY INOP AT ROW 12A-13A. REPLACED STRIP. OPS CHECK GOOD.SDR 97UAL900125Velcro Strap · wornSLIDE DOOR 1R VELCRO WILL NOT HOLD GIRT BAR. GIRT STRAP VELCRO LOOP MATERIAL (ATTACHED TO SLIDE BOTTLE) WAS WORN. REPLACED SLIDE. CURRENT MODIFICATION IN PROCESS WILL ELIMINATE GIRT STRAPS.
Back to N935UA, cancelled Jul 14, 2010