Service difficulty reports · 40
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR F3LA2012051600756Battery · dischargedWHILE ACCOMPLISHING CARD A332204-02 ON THE A6 CHECK THE POWER SUPPLY UNIT, 10 WL BATTERY FAILED THE CAPACITY TEST. ACFT OUT OF SERVICE. POWER SUPPLY UNIT BATTERY REPLACED IAW AMM 33-S1-38-000-002A AND 33-S1-38-400-002A. TESTED GOOD. ACFT RETURNED TO SERVICE.SDR F3LA2012041800741Switch · intermittentPATH LIGHTING AND EMERGENCY EXIT LGHTS COMING ON INTERMITTENTLY. REPLACED TOGGLE SWITCH, SIGNS & EMERGENCY EXIT LIGHT IAW ESPM 20-45-21. TEST OK REF AMM 33-51-00-710-004.SDR F3LA2011092600680Hose · rupturedON DEPARTURE, GREEN SYS FAILURE (FLUID LOSS) R & R LT MLG SWIVEL JOINT REF AMM 32-31-38-000, PB401. R & R FLEX HOSE ASSY REF AMM 32-31-39-000, PB 401. OPS LEAK CHECKED NORMAL, SERVICED GREEN HYD SYS 12-12-29-611-001, OK.
See all 40 reports