Service difficulty reports · 92
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR ABXA080240Current Limiter · failedCREW REPORTED SMOKE COMING FROM CIRCUIT BREAKER PANEL BEHIND CAPTAINS SEAT WHEN GROUND POWER WAS CONNECTED TO ACFT. FOUND GROUND SERVICE BUS CONTROL AND A & C PHASE GROUND SERVICE BUSS BREAKERS TRIPPED. REPLACED BLOWN CURRENT LIMITERS FOR CROSS TIE RELAY T2.SDR ABXA080118Light · out of positionMAP & BRIEFCASE CIRCUIT BREAKER TRIPPED, SMOKE EXITING FROM FIRST OFFICER'S MAP LIGHT ON FIRST OFFICER'S CONTROL COLUMN. REPOSITIONED LIGHT ASSEMBLY. SYSTEM CHECKS GOOD IAW DC9 AMM 33-13-00.SDR ABXA080026Window Frame · crackedCENTER AND SIDE WINDSHIELD RIGHT ZEE P/N: 5912360-68 CRACKED. REPLACED RIGHT ZEE IAW SR DWG 09530268, DC9 SRM 51-30-2, 51-30-5 AND JOB CARD EA 53300036-014.