CFM International CFM56-7B27 series
Service difficulty reports · 2,712
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'CFM567B27' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'CFM567B27' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026102920643Smyd · faultedYAW DAMPER DISENGAGED AUTOMATICALLY, YAW DAMPER LIGHT CAME ON AFTER TAKEOFF, THE YAW DAMPER LIGHT ILLUMINATED AND SPD LIM ON CA PFD SPEED TAPE. PERFORMED SMYD TEST, NR 1 HAD FAULT 27-31013. PERFORMED ADIRU BITE TEST, TESTED GOOD. SMYD TEST #2 TEST GOOD. SWASDR CALA2026110120691Battery Pack · inoperativeEMERGENCY LIGHTS, BATTERY WILL NOT CHARGE. REMOVED, REPLACED, & OPS CHECKED GOOD M1672 BATTERY PACK IAW AMM 33-51-06.SDR CALA2026110120693Battery Pack · inoperativeEMERGENCY LIGHTS BATTERY WILL NOT CHARGE. REMOVED, REPLACED AND OPS CHECKED GOOD M1694 BATTERY PACK IAW AMM 33-51-06.SDR CALA2026110120695Battery Pack · inoperativeM1675 EMERGENCY LIGHT BATTERY WILL NOT CHARGE. REMOVED, REPLACED, AND OPS CHECKED GOOD M1675 BATTERY PACK IAW AMM 33-51-06.SDR CALA2026110120697Battery Pack · inoperativeM2816 EMERGENCY LIGHTS BATTERY WILL NOT CHARGE. REMOVED, REPLACED, AND OPS CHECKED GOOD M2816 BATTERY PACK IAW AMM 33-51-06.SDR CALA2026103020655Battery Pack · inoperativeDURING SERVICE CHK, FOUND L2 DOOR EMERGENCY SIGN TO NOT COME ON AS WELL AS AFT GALLEY OVERHEAD SIGN. DURING TROUBLESHOOTING, SWAPPED BATTERY PACKS OF M1672 AND M1673 IN THE AFT GALLEY. FAULT FOLLOWED CONFIRMING IT NEEDS THE BATTERY PACK REPLACED. SWAPPED SDR CALA2026103020657Light · inoperativeRED EMERGENCY RED ISLE LIGHT OUT AT SEAT 20C. EMERGENCY LIGHT REPLACED IAW AMM 31-53-11.SDR CALA2026102720614Check Valve · detachedLEFT AIR CONDITIONING HEAT EXCHANGER AND PLENUM-DIFFUSER BYPASS CHECK VALVE DOOR DEPARTED AIRCRAFT.SDR CALA2026102820617Unknown · odorBAD ODOR IN CABIN DURING THE DESCENT FROM AIR CONDITIONING COMPLIED WITH FIM 21-00 TASK 806. NO ODOR NOTED FROM FLIGHT CREW. CABIN CREW NOTICED THE ODOR FOR 5 TO 10 MINS ON APPROACH, 20 TO 30 MINS FROM LANDING. NO ODOR OF ELECTRICAL OR SMOKED REPORTED. INSPSDR CALA2026103020653Battery Pack · inoperativeFOUND TWO OVERHEAD EMERGENCY LIGHTS INOPERATIVE AT ROWS 9FED & 14FED. R & R THE EMERGENCY AISLE LIGHTS AT ROWS 9DEF AND 14DEF. NO HELP, LIGHTS INOPERATIVE. FOUND ALL LIGHTS ASSOCIATED WITH POWER SUPPLY M1676 INOPERATIVE, INCLUDING OVER WING EXIT LIGHT L120SDR CALA2026102720591Light · looseEMERGENCY EXIT SIGN CEILING PANEL BY FWD LAV OUTSIDE FLIGHT DECK DOOR IS DROOPING ON THE RIGHT SIDE AND NEEDS TO BE RESECURED. SECURED CEILING PANEL JUST OUTSIDE LAV A.SDR CALA2026102820621Light · faultySEAT 36 CBA OVERHEAD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED SEAT 36 CBA EAL ASSY. PER AMM 33-51-03-960-805.OPS CHECK GOOD.SDR CALA2026102720592Cabin Pressure · lostPASSING 14000FT LOST PRESSURIZATION ON DESCENT GOT TO 8000, OUTFLOW VALVE OPENED. C/W CABIN DEPRESSURIZATION CONDITIONAL INSPECTION IAW AMM 05-51-81-210-801, NO DEFECTS NOTED. PERFORMED PRESSURIZATION SYSTEM GROUND TEST IAW AMM 21-31-00-700-802 OPS CHECK GOODSDR CALA2026110120683Skin · dentedFWD CARGO DOOR SKIN HAS MULTIPLE DENTS. REPAIRED FWD CARGO DOOR EXTERNAL SKIN BY REPLACING WITH NEW SKIN IAW SRM 52-30-01-2R-3 REPAIR 3 AND DWG 143A6110 REV-.SDR CALA2026102620566Battery Pack · inoperativeBOTH RIGHT SIDE OVERWING DOOR EMERGENCY EXIT LIGHTS INOP WHEN TESTED. LIGHTS BRIEFLY ILLUMINATE THEN EXTINGUISH WHEN TESTED. R & R MID RT. OVERWING DOORS EMERGENCY EXIT BATTERY PACK IAW AMM 33-51-06-960-805. OPS CHKD NORMAL.SDR CALA2026102620569Pitot Tube · faultedAUX PITOT LIGHT FOUND AUX PITOT HEATER C.B. D6 ON P18-3 PANEL TRIPPED. RESET C.B., NO HELP, AUX PITOT LIGHT STILL ILLUMINATED. RE-OPENED AUX PITOT C.B. ON P18-3 PNL. PITOT PROBE & GASKET ORDERED TO HANGAR WINDOW PIC OF ORDERED PARTS RMVD AND RPLD AUX PITOT PERSDR CALA2026102620552Cabin Pressure · uncontrollableCREW REPORTS UNABLE TO CONTROL CABIN ALTITUDE. EMERGENCY DECLARED. CREW DESCENDED TO 10,000FT. NO OVERWEIGHT LANDING. FLIGHT CREW REPORTS BURNING ODOR DURING DESCENT. RAN LEFT AND RIGHT PACKS TO EVALUATE FOR SMOKE ODOR IN CABIN, NO SMOKE ODOR NOTED IN CABIN RSDR CALA2026102220515Adiru · faultedIRS FAULT STARTED WITH IRS MOTION. REMOVED AND REPLACED AIR DATA IRU ASSY IAW AMM 34-21-01/401. OPS TESTED GOOD IAW AMM 34-21-00-710-80.SDR CALA2026102120484Battery Pack · inoperativeEMERGENCY LIGHTS DID NOT COME ON ROWS 22, 23, 24, 25 ABC. FOUND BATTERY PACK DEAD AT BS 500E, REPLACED THE BATTERY, SYSTEM CHKD GOOD.SDR CALA2026102120483Fuse · blownEMERGENCY LIGHT INOPERATIVE BTWN SEATS 27ABC - 21ABC. FOUND EMERGENCY BATTERY PACK CHARGER FUSE BLOWN. REMOVED AND REPLACED FUSE IAW AMM 33-51-06-960-804. EMERGENCY LIGHTS AT 27ABC TO 21 ABC. OPS CHKD GOOD.SDR CALA2026101620407Light · inoperativeAISLE EMERGENCY LIGHTS 15C AND 20C INOPERATIVE. REPLACED THE EMERGENCY LIGHTS IAW AMM 33-51-00. OPS CHKD GOOD.SDR CALA2026101320361Window · out of alignmentCAPTAINS WINDOWS OPENED ON TAKEOFF. REJECTED TAKEOFF AT LOW SPEED. WILL NOT CLOSE NOW. REALIGNED WINDOW WITHIN FRAME REF AMM 56-12-11/401. WINDOW NOW SLIDES FREELY AND LATCHES SECURELY. GOOD FOR SERVICE.SDR CALA2026101620409Unknown · odorGATE RETURN FOR UNUSUAL ODOR. ODOR SLIGHTLY PRESENT WITH APU AND MUCH MORE PRONOUNCED WITH ENGINE 2. PERFORMED SMOKE/ODOR IN FLIGHT DECK/CABIN CONDITIONAL INSPECTION WITH APU AND ENGINES RUNNING IAW AMM 05-51-26-800-801-C1. NO ODORS NOTED.SDR CALA2026101520367Battery Pack · inoperativeEMERGENCY LIGHTS AT SEATS 8ABC TO 14ABC INOPERATIVE. TROUBLESHOT & DETERMINED THAT BATTERY PACK LOCATED BELOW SEAT 8ABC TO BE DEFECTIVE. REMOVED AND REPLACED BATTERY PACK. OPS CHECK GOOD. IAW AMM 33-51-00.SDR CALA2026101520369Lens · brokenEMERGENCY LIGHT LENS AT ROW 39 ABC SIDE IS BROKEN. REMOVED AND REPLACED IAW AMM 33-51-11.SDR CALA2026101420363Warning Message · illuminatedREJECTED TAKEOFF DUE TO MAIN CABIN DOOR MASTER CAUTION LIGHT. LESS THAN 100KTS PERFORMED FORWARD ENTRY DOOR CHECK IAW AMM 52-11-00-200-801.SDR CALA2026100920241Battery · inoperativeFOUND L1 EXTERIOR SLIDE LIGHT INOPERATIVE, DURING A SERVICE CHECK. R & R L1 EXTERIOR EMERGENCY SLIDE LAMP IAW AMM 33-51-04-960-801. FOUND EMER BATTERY NOT HOLDING A CHARGE. R & R THE FWD OVERHEAD EMERGENCY BATTERY IAW AMM 33-51-06-960-805. OP CHECKED GOOD.SDR SWAA2026101280193Engine · bird ingestionBIRDSTRIKE UNDER FO WINDOW, ENGINE PARAMETER NORMAL, STRONG ODOR IN CABIN. BIRD REMAINS IN RT ENGINE, REMOVED AND CLEANED BIRD REMAINS, PERFORMED BIRD STRIKE INSPECTION ON NR 2 ENGINE IAW AMM 71-00-00. RAN ENGINE NR 2 AND PACKS IAW AMM 71-00-00 FOR 15 MINSSDR CALA2026101220265Light · brokenEMERGENCY EXIT LIGHT AT SEAT ROW 12 IS BROKEN. REPLACED LIGHT ASSY REF MM 33-51-11. OPS CHECK OK.SDR CALA2026101320354Light · inoperativeSIDEWALL EMERGENCY LIGHT INOP AT SEAT 20A. DOES NOT BLINK OR FLICKER. LIGHTING IS SUFFICIENT FOR CREW TO PERFORM DUTIES. C/W MEL 3302B. REMOVING THE OVERWING EXIT SIGN LIGHT ASSY. TASK 33-51-01-960-802 AND ALSO GET ACCESS TO THE LIGHT ASSY. INSTALLED ON THSDR CALA2026100720208Unknown · odorREPORT FAINT MUSTY SMELL WHEN CLIMBING FROM 6000 FEET THROUGH 13000 FEET. SMELL WENT AWAY AND CAME BACK DESCENDING THROUGH 13000 FEET AND WENT AWAY AGAIN THROUGH 10000 FEET. REPLACED RECIRCULATION FILTER, FOWARD PIT LEFT HAND SIDE. OPS CHECK NO SMELL.SDR CALA2026100820232Controller · faultedCABIN PRESSURE DIFF IS ABOVE LIMITS, DESCENDED FROM FL 390 TO 350. REMOVED AND REPLACED CPC NR 2 IAW AMM 21-31-01, OPS CHKD GOOD. INSPECTED BOTH PACK BAYS FOR LEAKS, NONE NOTED. INSPECTED OUTFLOW VALVE AND OVER PRESSURE VALVES. NO DEFECTS NOTED.SDR CALA2026100820233Unknown · odorSMOKE AND FUMES IN THE FLIGHT DECK ON TAKEOFF RTO AT 50 KTS. CREW INDICATED A HAZE WITH THE ODOR LIKE BURNED OIL. ACCOMPLISHED CONDITIONAL INSPECTION IAW AMM 05-51-26-800 -801-C. PERFORMED ENGINE RUN UP AT TAKEOFF POWER FOR 3 MINUTES IAW AMM 71-00-00-800-808SDR SWAA2026100916385Vta Actuator · leakingNR 1 ENGINE FUEL LEAK DURING ENGINE START. R & R RT VSV ACTUATOR ON NR 1 ENGINE IAW AMM 75-31-01. OPS AND LEAK CHECK GOOD.SDR CALA2026100520099Adiru · faultyIRS RT FAULT FOLLOWING FIM 34-21 TASK 803, PERFORMED BITE TEST AND FAULT MESSAGES ATTATCHED IN IMAGES. REMOVED AND REPLACED R ADIRU REF. AMM TASK 34-21-01-000-801 AND TASK 34-21-01-400-801. INSTALLATION TEST PASSED.PARTS USED: 60-3421-9-0001,QTY :1 POS - 2 MFGSDR CALA2026100620142Apu · faultedSMOKE ODOR CONDITIONAL INSP REQUIRED PER AMM 05-51-XX DUE TO AN INCIDENT REPORTED BY THE CREW. SMOKE IN THE COCKPIT FOLLOWED BY APU SHUT DOWN, APU GEN FEEDER CABLES APU MAINT MSG 49-72104. FOUND APU GENERATOR FEEDER CABLE BURNT. FOUND FEEDER CABLES ON APU GENSDR CALA2026100620166Unknown · odorHAD AN ABNORMAL ODOR COMING FROM THE AIR CONDITIONING AT LOW POWER SETTINGS. PERFORMED SMOKE/ODOR IN THE FLIGHT DECK/CABIN, CONDITIONAL INSPECTION UP TO AND INCLUDING STEP 1.C 2. (D) REF AMM 05-51-26-800-801-C1. NO DEFECT FOUND. OPS PACKS WITH APU BLEED ANDSDR CALA2026100720201Power Supply · faultedFIRST CLASS EMERGENCY LIGHTS INOP. REMOVED AND REPLACED FIRST CLASS EMERGENCY LIGHT POWER PACK, OPS CHECKED GOOD RED AMM 33-51-06-960-805SDR CALA2026100720202Fuse · failedFIRST CLASS EMERGENCY PATH LIGHTING WILL NOT ILLUMINATE ON ALL FIRST CLASS SEATS FOUND 2ND FUSE FROM THE RIGHT ON BATTERY PACK M2816 TO READ OPEN. REMOVED AND REPLACED FUSE REFERENCING AMM 33-51-06. OPS CHECK GOOD AT THIS TIME.SDR CALA2026100520121Lamp · inoperativeLH FWD EXTERIOR OVERWING EMERGENCY LIGHT INOP REMOVED AND REPLACE LAMP IAW AMM 33-51-04-960-801. OPS CHECK GOODSDR CALA2026100620168Battery Pack · inoperativeTHE EMERGENCY LIGHTS ON ROWS 35-39 INOPERATIVE. REMOVED AND REPLACED LEFT AFT EMERGENCY BATTERY PACK BATTERY PER REF AMM 33-51-06-960-805. OPS CHECK SUCCESSFUL.SDR CALA2026100520065Flashlight · not seatedBOTH FLASHLIGHTS INOPERATIVE AT R2 DOOR. FOUND BOTH AFT FLASHLIGHTS NOT SET CRADLE PROPERLY. REMOVED AND INSTALLED THE FLASHLIGHTS IN CRADLE AND OPS TESTED GOOD IAW AMM 25-64-00.SDR CALA2026100720197Module · faultedREJECTED TAKEOFF AT 110KIAS DUE TO FIRE WARNING. PERFORMED ENG & APU FIRE DETECT CONTROL MODULE BITE IAW AMM 26-10-00-710-801. NO HELP, PERFORMD A HIGH POWER ENG RUN. CREW STATED THAT ALL SIX FIRE INDICATIONS WENT OFF ON TAXI OUT TRAVELING AT 110KIAS, APU WSDR CALA2026092919966Frame · not reportedREFERENCE 6541159. LOG CREATED FOR SDR TRACKING OF ECRA 5360-02033 - DUPLICATE OF SFR #1638SDR CALA2026100620126Stringer · fomSTRINGER S24L AT BS 847 NEEDS DISPLACED TO FOM. CUT STRINGER S24L BETWEEN STA 807-827 PER SRM 53-00-03-2R-1. FABRICATED REPAIR PARTS, ACCOMPLISHED STEPS 4D THROUGH 4J PER SRM 53-00-03-2R-1. VERIFIED FABRICATION OF REPAIR PARTS, ACCOMPLISHED STEPS 4D THROUGH 4SDR CALA2026092919961Wire · brokenOPERATIONAL CHECK OF EMERGENCY LIGHTS, L1 DOOR, COAT STORAGE EMERGENCY LIGHT INOPERATIVE. FOUND A WIRE BROKEN AT CONNECTOR. DISCONNETED CONNECTOR D004J/D004P TO FOM IAW CMM 25-20-23, REQUESTING DEFERRAL OF FLOOR PROX EMERGENCY PATH LIGHT. MEL 3319E REJECTSDR CALA2026093020012Light · inoperativeFLOOR EMERGENCY LIGHT INOPERATIVE AT ROW 11ABC. REPLACED THE EMERGENCY LIGHT AT ROW 11ABC.SDR CALA2026092819937Battery Pack · inoperativeRT SIDE AFT CABIN CEILING BULLNOSE EMERGENCY LIGHTS INOPERATIVE, REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-805, OPS CHECKED GOOD.SDR CALA2026092919964Pitot Tube · faultedAIRSPEED DISAGREE, RAN NON NORMAL CHKLST, SUSPECT FROZEN PITOT TUBE, FO SIDE IAW AMM 34-11-01, PERFORMED INSP OF FO SIDE PITOT PROBES. DID NOT FIND ANY ABNORMALITIES. ALL 3 PITOTS BEGAN WARMING UP WITH SWITCH. T/S IAW FIM 31-62, TASK 876. FOUND FAULTS 31-SDR CALA2026093020015Battery Pack · dischargedL2 DOOR EMERGENCY LIGHTS WERE FOUND INOPERATIVE DURING INSPECTION. CHARGED THE BATTERY PACK IAW AMM 33-51-06. OPS CHKD GOOD.
Back to CFM International CFM56-7B27 series