GE CFM56 series
Service difficulty reports · 5,028
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'CFM56' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'CFM56' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2001UALA02464Frame · crackedAFT CABIN FRAME STATION 987, NEXT TO STRINGER 9L CRACKED. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED FRAME REPAIR USING CHANNEL AND FILLER.SDR 2001UALA02459Stringer · dentedRIGHT HAND EXTERNAL FUSELAGE BODY STATION 226 STRINGER 19R DENTED 4 INCHES DIAMETER AND IS .075 INCH DEEP. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2001UALA02443Bulkhead · crackedBS 178 BULKHEAD WEB, LBL 5.7, WL 211 HAS CRACKS. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLERS AND FILLER MATERIAL.SDR 2001UALA02438Floorbeam · damagedCABIN FLOORBEAM STATION 967 RBL 10 HOLE ELONGATED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE. INSTALLED ANGLE REPAIR WITH FILLER.SDR 2001UALA02439Floorbeam · damagedAFT CABIN FLOORBEAM STATION 947 RBL 46 WL 208 BLENDED REPAIR OUT OF LIMITS. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED T-CAP. MANUFACTURED NEW T-CAP. INSTALLED NEW CAP AND SPLICE ANGLES.SDR 2001UALA02440Frame · crackedAFT CABIN FRAME (STATION 847) NEXT TO STRINGER 9L IS CRACKED WHERE AIR GRILL CLIP ATTACHES TO FRAME. MAJOR REPAIR ACCOMPLISHED. DAMAGE REMOVAL VERIFIED. DOUBLER INSTALLED.SDR 2001UALA02444Transducer · malfunctionedPLANE DIVERTED TO LAX DUE TO ANTISKID PROBLEM, AND SHORT RUNWAYS AT BUR. SUPPLEMENTAL DATA UPDATE REPLACED LEFT MLG INBOARD ANTI-SKID TRANSDUCER.SDR 2001UALA02430Skin · dentedFORWARD CARGO DOOR HAS DENT APPROXIMATELY .3175 TO .3750 OF AN INCH DEEP BY 2.75 INCHES WIDE BY 3.75 INCHES LONG. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2001UALA02421Bulkhead · crackedBODY STATION 178 LBL 5.7 WL 200 HAS CRACK INDICATION WITH NON-DESTRUCTIVE TESTING. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER AND FILLER.SDR 2001UALA02422Bulkhead · crackedBODY STATION 178 LBL 5.7 WL 211 WEB HAS CRACK INDICATION BY NON-DESTRUCTIVE TESTING. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER AND FILLER.SDR 2001UALA02410Bulkhead · crackedBODY STATION 178 RBL 5.7 WL 200 WEB CRACKED IN 2 PLACES. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER AND FILLER MATERIAL.SDR 2001UALA02411Bulkhead · crackedBODY STATION 178 LBL 5.7 WL 200 WEB CRACKED. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED DOUBLER AND FILLER MATERIAL.SDR 2001UALA02409Skin · dentedRIGHT HAND HORIZONTAL STABILIZER LEADING EDGE DENTED 5 FEET FROM OUTBOARD END. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED FLUSH REPAIR.SDR 2001UALA02407Warning System · activatedLANDED UNDER AMBER ALERT DUE TO RUDDER CONTROL PROBLEMS.SDR 2001UALA02387Frame · crackedSTATION 188, WL 207, FUSELAGE RIGHT FRAME CHORD CRACKED IN RADIUS. MAJOR REPAIR ACCOMPLISHED, MANUFACTURED & INSTALLED REPAIR DOUBLERS.SDR 2001UALA02390Skin · dentedEXTERNAL FUSELAGE DENTED STATION 1008 STRINGER 11R. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE & INSTALLED DOUBLER.SDR 2001UALA02388Frame · crackedBODY STATION 616 BELOW STRINGER 17R INNER CHORD CRACKED ON FRAME. MAJOR REPAIR ACCOMPLISHED, CRACK REPAIRED.SDR 2001UALA02389Bulkhead · crackedWEB CRACKED ON STATION 178 BULKHEAD AT WL 195, LBL5.7. MAJOR REPAIR ACCOMPLISHED, CRACK REPAIRED.SDR 2001UALA02385Stringer · dentedCABIN STRINGER 13 LEFT AT STATION 1010 DENTED BETWEEN FASTENERS. MAJOR REPAIR ACCOMPLISHED, REINFORCED STRINGER SPLICE REPAIR.SDR 2001UALA02372Skin · dentedFUSELAGE SKIN DENTED 8 INCHES LEFT OF LOWER CENTERLINE AT STATION 197. MAJOR REPAIR ACCOMPLISHED, SKIN DOUBLER INSTALLED.SDR 2001UALA02379Skin · dentedLEFT HORIZONTAL STABILIZER LEADING EDGE, 8 FEET FROM INBOARD END, DENT BETWEEN RIBS. MAJOR REPAIR ACCOMPLISHED, DOUBLER REPAIR MANUFACTURED AND INSTALLED.SDR 2001UALA02380Stringer · crackedBODY STATION 188 STRINGER 17R CORD CRACKED. MAJOR REPAIR ACCOMPLISHED, REPAIRED STRINGER.SDR 2001UALA02381Web · crackedFORWARD CARGO DOOR CLOSING WEB CRACKED AT STRINGER 26R BODY STATION 496. MAJOR REPAIR ACCOMPLISHED, CRACK REPAIRED.SDR 2001UALA02393Oven · fireCREW REPORTS FORWARD GALLEY OVEN HAD A SMALL DEBRIS FIRE (PAPER). USED HALON BOTTLE TO EXTINGUISH. REMOVED AND REPLACED FORWARD OVEN, CHECKS OK.SDR 2001UALA02367Frame · crackedFUSELAGE FRAME CHORD AT STATION 188 AT WL 207 RIGHT HAND SIDE IS CRACKED IN RADIUS. MAJOR REPAIR ACCOMPLISHED, FRAME CHORD REPAIRED AND FUSELAGE DOUBLER INSTALLED.SDR 2001UALA02368Skin · dentedEXTERNAL FUSELAGE STATION 240 8 INCHES ABOVE LOWER SKIN LAP DENTED. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED DOUBLER REPAIR.SDR 2001UALA02369Floorbeam · crackedBODY STATION 520 FLOOR BEAM WEB CRACKED AT LBL 24.75. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED REINFORCEMENT REPAIR.SDR 2001UALA02370Bulkhead · crackedSTATION 178 BULKHEAD WEB AT RBL 5 WL 202 HAS CRACK. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED DOUBLER AND FILLER.SDR 2001UALA02371Bulkhead · crackedSTATION 178 BULKHEAD WEB CRACKED AT LBL 5 WL 199. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED DOUBLER AND FILLER.SDR 2001UALA02361Floor Support · corrodedRT CREASE BEAM FLOOR SUPPORT ANGLE CORRODED STATION 947 TO 1006. MAJOR REPAIR ACCOMPLISHED, REPLACED CREASE BEAM FLOOR SUPPORT ANGLE.SDR 2001UALA02362Floorbeam · damagedFORWARD CABIN FLOORBEAM AT BODY STATION 328 RBL 48 DAMAGED AT EDGE OF FLOOR BEAM UPPER CHORD. MAJOR REPAIR ACCOMPLISHED, STRAP REPAIR INSTALLED.SDR 2001UALA02363Frame · crackedFUSELAGE FRAME OUTER CHORD STATION 188 WL 207 LEFT SIDE IS CRACKED IN RADIUS. MAJOR REPAIR ACCOMPLISHED, INSTALLED DOUBLER.SDR 2001UALA02364Skin · dentedAT STATION 1012 STRINGER 12L, FUSELAGE HAS A DENT OUT OF LIMITS, DENT WITHIN 10 INCHES OF SPLICE, AND COMMON TO A STRINGER. MAJOR REPAIR ACCOMPLISHED, DOUBLER INSTALLED.SDR 2001UALA02365Skin · dentedEXTERNAL FUSELAGE AT BODY STATION 1012 APPROXIMATELY ON STRINGER 13L SKIN IS DENTED. MAJOR REPAIR ACCOMPLISHED, SKIN DOUBLER INSTALLED.SDR 2001UALA02366Shear Tie · damagedSTATION 1006 SHEAR TIE BETWEEN STRINGER 11L AND 12L NICKED OUTSIDE RADIUS. MAJOR REPAIR ACCOMPLISHED, FABRICATED NEW SHEAR TIE AND REPAIRED.SDR 2001UALA02378Floorbeam · damagedFORWARD CABIN FLOORBEAM AT BODY STATION 328 RBL 48 HAS DAMAGE WHICH EXCEEDS .250 FROM EDGE OF FLOORBEAM UPPER CHORD. MAJOR REPAIR ACCOMPLISHED, STRAP REPAIR INSTALLED.SDR 2001UALA02352Angle · crackedCABIN FLOOR ANGLE AT BL 0 CRACKED FROM STATION 927-947. MAJOR REPAIR ACCOMPLISHED, REPLACED ANGLE.SDR 2001UALA02349Doubler · chafedRT WING LEADING EDGE SKIN HAS CHAFING WEAR ON SCAB PATCH JUST INBOARD (16 INCHES) OF NR 2 ENGINE. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW DOUBLER AND FILLER.SDR 2001UALA02350Door Frame · crackedFORWARD GALLEY DOOR CUTOUT FORWARD LOWER STUB FRAME HAS 2 EACH CRACKS JUST ABOVE FLOOR LEVEL AT STATION 294 RBL 55. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE. FILLER AND FORMED SECTION REPAIR INSTALLED.SDR 2001UALA02351Bulkhead · crackedSTATION 178 BULKHEAD WEB SHOW CRACK INDICATION AT LBL 5.7 AT WL 212. MAJOR REPAIR ACCOMPLISHED, FABRICATED & INSTALLED DOUBLER AND FILLER.SDR 2001UALA02344Strap · crackedSTRAP CRACKED UNDER UPPER CAP OF BODY STATION 727A FRAME AT RBL 18. MAJOR REPAIR ACCOMPLISHED, THE END OF THE STRAP WAS TRIMMED OFF TO REMOVE THE CRACK. REPAIR WAS INSTALLED.SDR 2001UALA02348Bulkhead · crackedSTATION 178 BULKHEAD SKIN IS CRACKED 3 INCHES BELOW EXISTING REPAIR. LBL 5 BELOW WL 200. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED DOUBLER REPAIR.SDR USAATA01065Battery · dischargedTHE CENTER OVERHEAD EMERGENCY EXIT LIGHT WAS FOUND FLASHING WITH THE SYSTEM OFF. MAINTENANCE REPLACED A BATTERY PACK. OPERATIONALLY CHECKS, OK.SDR 2001UALA02343Floorbeam · gougedCABIN FLOORBEAM AT STATION 328, RBL 48 HAS DEEP GOUGE ON UPPER SURFACE. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. INSTALLED SPLICE REPAIR.SDR 2001UALA02346Bulkhead · crackedSTATION 178 BULKHEAD LBL 5.7 AT WL 210 HAS CRACK INDICATION. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED FILLER AND DOUBLER AND INSTALLED.SDR 2001UALA02347Bulkhead · crackedSTATION 178 BULKHEAD RBL 5.7 AT WL 210 HAS CRACK INDICATION. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. FABRICATED FILLER AND DOUBLER AND INSTALLED.SDR 2001UALA02331Bulkhead · crackedSTATION 178 BULKHEAD RBL 5.7 WL 200 HAS 2 CRACK INDICATIONS FOUND BY NONDESTRUCTIVE TESTING. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED DOUBLER AND FILLER.SDR 2001UALA02345Bulkhead · crackedSTATION 178 BULKHEAD RBL 5.7 WL 200 HAS 2 EA CRACKS. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND FILLER.SDR 2001UALA02330Door · crackedDOOR 1R LOWER FRAME OUTBOARD STOP FITTING CRACKED. MAJOR REPAIR ACCOMPLISHED.INSTALLED SPLICE REPAIR ON FRAME.SDR 2001UALA02318Bulkhead · crackedBODY STATION 178 BULKHEAD RBL 5.7, WL 200 WEB CRACKED. MAJOR REPAIR ACCOMPLISHED, INSTALLED REPAIR DOUBLER ON FORWARD SIDE OF BULKHEAD.
Back to GE CFM56 series