SDR CALA2026102220511Structure · no discrepancyLOWER NOSE SECTION HAD A BIRD STRIKE DURING CLIMBOUT AT 5000 FT, FLAPS UP & NO ODOR IN THE CABIN. BIRDSTRIKE WAS ON THE LT NOSE AREA JUST AFT OF THE RADOM AND FWD OF THE STBY STATIC PORT. EXTENDED SLATS & FLAPS AND COMPLIED WITH THE BIRD STRIKE INSPECTION SDR YENA2026102200992Engine · stalledFLT 219, BOS-BOS. (ETOPS) AFTER ENGINE START THE NR 1 ENGINE RAN NORMALLY FOR A FEW MINUTES AND THEN STALLED ECAM- ENG 1 STALL.SDR DALA2026101805705Packing · leakingAT 15,000 FT ON DECENT INTO SLC FA OBSERVED MUSTY DIRTY SOCK AND PAINT SMELL IN AFT OF AIRCRAFT. ON SHORT FINAL AND TAXI IN ODOR INCREASED AND MOVED TO ENTIRE CABIN. FOUND NR 2 EBG EVIDENCE OF NOSEBLEED. REMOVED NOSE CONE AND FOUND OIL POOLING. REPLACED NR 2SDR YENA2026101900987Fire Loop · faultedFLT 1621, LHR-BOS. (ETOPS) ENG NR 2 FIRE LOOP B FAULT ( ENGINE FIRE DETECTION SYSTEMS LOOP B."(SUPPLEMENTAL INFORMATION TO FOLLOW).SDR YENA2026101600984Turnbuckle · brokenFLT # 387, BOS-LAX. (ETOPS) "ENG 2 T/R TURNBUCKLE FLAG INOPP. ENG# 2 TR CLOUSURE ASSIST TURNBUCKLE FLAG BROKEN. "(SUPPLEMENTAL INFORMATION TO FOLLOW).SDR CALA2026101520365Unknown · odorFOUR MINUTES AFTER ENG SHUT DOWN, DURING DEPLANING PAX & FLT ATTNDNTS NOTED BURNING ODOR UNABLE TO VERIFY FAULT, CYCLED PACKS, WALKED CABIN THROUGH WITH PACKS ON & OFF AT DIFFERENT TEMP SETTINGS, NO ODOR.SDR YENA2026101400948Circuit Breaker · trippedFLT # 188, LAX-BOS. (ETOPS) C/B R 44 ENGINE #1 REV LOCK C/B TRIP ( THRUST REVERSER SYSTEMS ).SDR CALA2026101520380Slide · no testWHILE PERFORMING EMERGENCY LIGHT TEST, CIDS 1, EPSU SYS TEST FAILED. REPLACED EPSU BATTERY AT 11WL IAW AMM 33-51-38, OPS CHECK OK. REPLACED EPSU BATTERY AT 17WL IAW AMM 33-51-38, OPS CHECK OK. REPLACED EPSU BATTERY AT 13WL IAW AMM 33-51-38, OPS CHECK FAILS SDR YENA2026101200939Exciter · faultedFLT # 1577, BOS-LAS. (ETOPS) "ENG 2 IGNITION A FAULT ( IGNITION SYSTEMS SYSTEM A ) ; REMOVED AND REPLACED ENG #2 IGN EXCITER IAW AMM 74-11-01. IGNITION TEST PASS ON BOTH CHANELS WITH BOTH IGNITERS, MX-4 UPDATED PLACARD REMOVED."SDR DALA2026101005581Engine · odorATB TO SFO DUE TO MUSTY ODOR REPORTED IN THE AFT GALLEY. DECLARED EMERGENCY. REPLACED NR 2 ENGINE. (LP 8950426, 8950435 - AIRCRAFT WAS GROUNDED)SDR YENA2026100700928Seal · damagedFLT # 842, DUB-JFK. (ETOPS) "WHILE PERFORMING OIL CONSUMPTION MONITORING TASK PW1100G-A-78-00-00-01A-310A-A. NO OIL DRIPS WERE FOUND AT THE DRAINS. REPLACEMENT OF MAIN GEARBOX GENERATOR DRIVE OIL SEAL &DEOILER DRIVE OIL SEAL REQUIRED ; REPLACED ENG 1 MAIN GEARSDR CALA2026102320534Sensor · faultedNR 2 ENGINE DUE TO THE OIL LOSS IN FLIGHT AND VIBRATION EVENT PRIOR TO NEXT FLIGHT COMPLETE THE ENGINE OIL SYSTEM (DMS) INSPECTION PER THE AMM 79-00-00-200-806-G00. . REMOVED AND REINSTALLED OIL DEBRIS MONITORING SENSOR IAW AMM 79-35-21-000-801-A & 79-35-21-SDR DALA2026100205469Engine · odorFUME - ATB DUE TO ODOR IN THE COCKPIT ON TAKE OFF DURING MAINTENANCE FERRY FOR RIGHT ENGINE CHANGE. PERFORMING LEVEL C DECONTAMINATION. SHIPPING ENGINE TO JFK FOR RIGHT ENGINE CHANGE. REPLACED RIGHT ENGINE. (LP 9461658, 1837443 - AIRCRAFT WAS GROUNDED)SDR CALA2026093020011Slide · no testREMOVED SLIDE FROM R1 DOOR PER WORKCARD, NEW SLIDE BAD FROM STOCK. REINSTALLED ORIGINAL SLIDE IAW AMM 25-62-44-400-803-A OPS CHECK GOOD.SDR YENA2026093000916Sense Line · damagedFLT 353, BOS-DUB. (ETOPS), AFTER TAKEOFF AND THRUST REDUCTION ENG 1 SENSOR FAULT EICAS MESSAGE, ENGINE 1 SENSOR FAULT. REMOVED & REPLACED SHEARED BURNER PRESS SENSE LINE ( AS11) PER AMM 73-21-23, PERFORMED ENG RUNS FOR OPS CHK + LEAK CHECKS PER AMM 71-00-SDR DALA2026100205468Seal · leakingFUME- ATB DUE TO FUMES IN THE COCKPIT. REPLACED LEFT ENGINE FRONT FACE SPINNER SEAL, AND PERFORMED P TRAK RUNS. OK FOR SERVICE. (LP 9461638, 1833463 - AIRCRAFT WAS GROUNDED)SDR YENA2026092500901Engine · faultedFLT # 1577, BOS-LAS. (ETOPS) "ENG 1 MINOR FAULT AFTER LANDING ( MINOR FAULT CAUTIONS ON ECAM E/WD )." (SUPPLEMENTAL INFORMATION TO FOLLOW).SDR YENA2026092500902Rub Strip · damagedFLT 1621, LHR-BOS. (ETOPS) "DAMAGE FOUND ON ENG 2 FAN CASE RUB STRIP. DAMAGE OUT OF LIMITS PER AMM 72-21-01-220-802-A. DENT 1 IS .43 X .43 DENT 2 IS .43 IN LENGTH .125 IN W AREA IS LIMIT ; PERFORMED REPAIR OF ENG #2 FAN CASE RUB STRIP @ 7 0'CLOCK POSITION ISDR CALA2026092419791Light · inoperativeEMERGENCY EXIT LIGHT AISLE PATH LIGHT INOP ROW 15 ABC. REQ MEL 3350B. ALL OTHER EMERGENCY EXIT SIGNS OPS OK. OK TO APPLY MEL 3350B FOR INDIV PATH LIGHTING INOP CW MEL 3350B. *DM* SEE M&L FOR EMERGENCY SEAT LIGHT ASSY (19-3300-3-0038) AND SEAT SHROUD (42-2521-SDR CALA2026092919967Engine · contaminatedFA REPORTED A STRONG DIRTY SOCK, GYM BAG ODOR ON DESCENT BTWN 15000-10000. ODOR WENT AWAY WHEN PACK 2 SELECTED OFF. NO DETECTABLE ODOR IN FLIGHT DECK. LAST OCCURRENCE CONFIRMED STRONG SOCK ODOR COMING FROM PACK 2. REMOVED NR 2 ENG INLET DOME COVER, NO OIL SDR CALA2026092119560Unknown · odorFOUL ODOR COMING FROM APU BLEED, FWD CABIN ODOR DISSIPATED AS MX ARRIVED. RAN PACKS WITH APU BLEED, NO ODOR NOTED. INSPECTED CARGO COMPARTMENTS AND FWD ELECTRICAL COMPARTMENT. SPOKE TO CREW, THEY NO LONGER SMELLED THE FOUL ODOR. OK FOR SERVICE.SDR YENA2026092100856Ignition Sys · faultedFLT 1524, LAX-JFK. (ETOPS) ENG 2 IGN A FAULT ( IGNITION SYSTEMS SYSTEM A ). R & R ENG NR 2 IGNITION A IAW AMM 74-21-01-400-801-A. OPS CHK OK.SDR YENA2026092100857Tie Rod · excess playFLT 2220, LHR-JFK. (ETOPS) DURING T/C A320-29-10-00-220-004A ON W/O 1524471, FOUND UPPER HYDRAULIC INTER. TIE ROD ON ENG NR 2 TO HAVE AXIAL PLAY OUT OF LIMITS. R & R THE ENG NR 2 PYLON/ ENGINE INTERFACE TIE ROD (UPPER) IAW AMM 29-15-61.SDR YENA2026092100858Tie Rod · excess playFLT 2220, LHR-JFK. (ETOPS) DURING T/C A320-29-10-00-220-004A ON W/O 1524471 FOUND LOWER HYDRAULIC INTER. TIE ROD ON ENG NR 2 TO HAVE AXIAL PLAY OUT OF LIMITS, R & R ENG NR 2 PYLON/ ENGINE INTERFACE TIE ROD (LOWER) IAW AMM 29-15-61.SDR DALA2026091905235Seal · leakingAIRCRAFT 5043, DURING DESCENT AT 19,000 FT. FA'S REPORTED MUSTY ODOR ORIGINATING AT THE AFT GALLEY AND BEING AS STRONG UP TO ROW 30. THE SMELL LESSENED BUT CONTINUED TO THE FORWARD GALLEY. NO SMELL WAS DETECTED ON THE FLIGHT DECK. SMELL LESSENED SLIGHTLY AT LOSDR YENA2026091700808Fire Loop · faultedFLT 263, JFK-SEA. (ETOPS) ON CLIMB OUT ENG 1 FIRE LOOP A FAULT ( ENGINE FIRE DETECTION SYSTEMS LOOP A ). OPENSDR YENA2026091700807Vane · damagedFLT 220, SAN-BOS. (ETOPS) ENG 2 SECOND STAGE TURBINE VANE LE HAS EROSION WITH BURN THROUGH IN AREA B. OPENSDR YENA2026091400800Actuator · inoperativeFLT # 224, LAX-JFK. (ETOPS) "ENG2 OUTBD T/R OPENING ACT INOP ( DUCT OPENING ACTUATOR )."(SUPPLEMENTAL INFORMATION TO FOLLOW).SDR DALA2026091505140Engine · odorFA REPORTS OIL SMELL IN CABIN AFTER SWITCHING TO APU BLEED AT GATE. REPLACED NR 1 ENGINE. (LP 9171240 - AIRCRAFT WAS GROUNDED)SDR DALA2026091505141Engine · vibrationDIVERTED TO DTW DUE TO LEFT ENGINE HIGH VIBRATION ECAM MESSAGE. PERFORMED HPC AND HPT BSI WITH NO FINDINGS. PREPPING FOR VIBRATION SURVEY. REPLACED NBR 1 ENGINE. (LP 9543400 - AIRCRAFT WAS GROUNDED)SDR YENA2026091400799Guide Vane · damagedFLT # 324, LAX-JFK. (ETOPS) NR 1 ENG SGV INNER LINER MISSING SMALL PIECE @ BETWEEN 7 - 9 O'CLOCK POSITION.SDR YENA2026091600803Pump · failedFLT 1621, LHR-BOS. (ETOPS) ENG 2 HYD DPI IS OUT. R & R NR 2 ENG HYD EDP IAW AMM 29-13-51 OPS CHECK LEAK CHECK OK.SDR DALA2026090805023Oil System · overservicedFLIGHT ATTENDANT REPORT DIRTY SOCKS SMELL BY OVERWING EXITS FOR 5-10 MINUTES DISSIPATE WITHOUT ACTION, WAS NOT NOTICED IN THE FORWARD OR AFT CABIN. ENG 2. VERIFIED ENG 2 HAD OIL OVER-SERVICED. C/W ENG # 2 OIL DRAIN VIA SUCTION METHOD FROM THE OIL SERVICING PSDR YENA2026090800730Warning Message · intermittentFLT 346, BCN-BOS. (ETOPS) SEVERAL NR 1 ENG FIRE LOOP A FAULT MSGS DURING FLIGHT, THEY CLEARED THEMSELVES BUT KEPT POPPING UP. OPENSDR YENA2026090400728Sensor · failedFLT 224, LAX-JFK. (ETOPS) ENGINE NR 2 N1 VIBRATION ECAM INTERMITTENT THROUGH OUT FLIGHT VALUEVARIED BETWEEN .2 AND 10.0 FOR 5-10 SECONDS AT A TIME ; UPON INSPECTION FOUND N1 AFT SENSOR HARNESS CHAFED. R & R AFT N1 SENSOR IAW AMM 77-32-22. NO DEFECTS NOTED. PSDR YENA2026090800729Fire Loop · faultedFLT# 73, JFK-EDI. (ETOPS) RECEIVED A POST FLIGHT MX REPORT ENG 2 FIRE LOOP B FAULT, OPENSDR YENA2026090400727Ignition Sys · faultedFLT 1407, JFK-CDG. (ETOPS) ENG 2 IGN B FAULT ( IGNITION SYSTEMS SYSTEM B ). OPENSDR CALA2026090719291Generator · faultedLAVATORY VACUUM PUMP MAKING A GRINDING NOISE. VACUUM GENERATOR DEACTIVATED IAW MEL38-30-01-01 (M). VACUUM SYS AND VACUUM GEN CIRCUIT BREAKERS PULLED AND SAFETIED. ALL LAVATORY TOILET SYSTEM COMPONENTS CHECKED WITH NO LEAKS NOTED. COMPLIED WITH MEL 3830G, SDR DALA2026090304988O-Ring · leakingFUMES REPORTED, DIRTY SOCK ODOR AT TOP OF DESCENT THROUGH LANDING. DETECTED BY FLIGHT ATTENDANTS. FOUND FAN SHAFT COVER ON NR 2 ENGINE LEAKING., REPLACED O-RING & LEAK CHECKED IAW AMM 72-15-00-960-801-A. NO LEAKS FOUND. PERFORMED LEVEL B DECONTAMINATION IASDR CALA2026090419229O-Ring · leakingMUSTY SOCK ODOR ON FLIGHT DECK AND FWD ECONOMY CABIN MOST PRONOUNCED DURING DECENT PIREP DIRTY SOCK ODOR STRONG THROUGHOUT FLIGHT, STRONGEST ON DESCENT. ON WALKAROUND, NOTED OIL STREAKING FROM LEFT PACK EXHAUST ALL THE WAY BACK TO TAIL. REMOVED E1 INLET SPINSDR CALA2026090419230Unknown · odorSMOKE/ODOR AMM 05-51-10-200-801-C1 CHECK REQUIRED UPDATE WITH ODOR/SMOKE FORMS PERFORMED SMOKE/ ODOR CHECK WITH AMM 05-51-10-200-801-C1. REF LOG PAGE 3199113 FOR WORK PERFORMED.SDR DALA2026090104926Blades · damagedDISCONTINUED TAKEOFF AT 60 KNOTS DUE TO RIGHT ENGINE HIGH VIBE WARNING. PERFORMED BORESCOPE FOUND HPT BLADE DAMAGE. REPLACED NR 2 ENGINE. (LP 7531667, 7531668 - AIRCRAFT WAS GROUNDED)SDR YENA2026090100720Generator · warning messageFLT 1534, SFO-BOS. (ETOPS), AFTER ENG SHUTDOWN MX MSG - AC GEN ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY FAULT(S) INDICATED BY GPCU OR AC GEN ). OPENSDR YENA2026090100718Wire Harness · failedFLT 1408, CDG-JFK. (ETOPS). FOUND W04 HARNESS CHAFED AND DAMAGED ON NR 2 ENG. INSTALLED NEW W04 HARNESS PER AMM 73-21-64. REQUIRES OPS CHK CHAFFING TAPE AND FADEC CONNECTORS TO BE INSTALLED."SDR YENA2026090100719Seal · failedFLT # 32, AMS-BOS. (ETOPS), DURING ENG 2 SCHEDULED MX FOUND IDG DRAIN PLUG UNION SEAL DAMAGED, SEAL NOT IN CMM, AMM, EMM ; R/R IDG 2 IAW AMM 24-21-51, OPS CHK GOOD.SDR F3LA202608310445Engine · leakingFA'S REPORTED STRONG DIRTY SOCK SMELL IN CABIN BELOW FL180 ON ARRIVAL. AIRCRAFT WAS REMOVED FROM SERVICE. INSTALLED NR 2 ENGINE IAW TASKCARDS: MP71042-05/ MP71042-06. LEAK CHECK OK. OPS CHECK OK. ORIGINAL SUBMISSION DATE: 8-31-2026SDR YENA2026082400701Filter · faultedFLT 1178, LAS-BOS. (ETOPS) "INSUFFICENT INFO IN TASK CARD A320-24-21-00-920-802-A. FOR ENG 2 IDG DRAIN/FILL W/FILTER REPLACEMENT; C/W W/REF AMM 24-21-51-960-801-A + REMOVED + REPLACED IDG 2 FILTERS + SERVICING. LEAK CK GOOD. THIS ALSO C/W WO 1517593."SDR DALA2026082504812O-Ring · leakingDESCENDING THROUGH 6K AFT FA CALLED WITH ODOR DESRIBED AS BURNT POPCORN. AT 3K PURSER CALLED AS SHE COULD NOW SMELL ODOR, SHE SAID WAS DIRTY SOCK. PILOTS NEVER SMELLED ANY ODOR. ODOR SEEMED TO BE TEMPORARY IN NATURE. FOUND OIL IN #2 ENG. REPLACED #2 ENG FAN SDR DALA2026082404785Oil System · leakingMUSTY VINEGAR SMELL IN CABIN DURING DESCENT AT 10,500FT. PASSENGERS FROM COMFORT PLUS TO THE LAST ROW IN MAIN CABIN NOTICED THE ODOR. ODOR WENT AWAY WITHIN 10 MINUTES. FOUND MINOR PUDDLE OF OIL ON NR 2 ENGINE. REPLACED FAN SHAFT COVER SEAL OUT OF PRECAUTION SDR CALA2026082518884Filter · cloggedSTRANGE ODOR ON DESCENT STARTED AT 13000 DAMP DIRTY SOCK SMELL PER TSM 05-50-00-810-831-A TYPE 6 LEVEL A PERFORMED PACK BURN FOR 25 MINS AND ALSO REMOVED AND REPLACED RECIRCULATION FILTER CARTRIDGES PER AMM TASK 21-21-41-000-001-A PACKS RAN NORMAL AND NO SMELL
Back to IAE PW1133GA-JM