SDR CALA2013121193586Container · faultyIAW CF270 MANUAL DROP TEST, SEATS 24DEF DID NOT DROP. REPLACED EMERGENCY OXYGEN CONTAINER.SDR CALA2013121193587Oxygen Mask · malfunctionedIAW CF270 MANUAL DROP TEST, SEATS 32DEF DID NOT DROP. IAW SERVICE TIP MT 35-002 REPACKED MASKS AT SEAT 32DEF, CHECKED OK.SDR CALA2013112793304Interface Unit · faultyLGCIU 2 FAULT DISPLAYED ON UPPER ECAM SCREEN LG. COMPLIED WITH MT 32-002, NO FAULT CODES FOUND. REPLACED NR 2 LGCIU IAW MM, TESTED OKAY.SDR CALA2013120293373Microphone · defectiveUNABLE TO TRANSMIT FIRST OFFICER`S SIDE, RADIO HANDSET & MIC. TROUBLE SHOT TO A BAD MIC FIRST OFFICER`S POSITION. R & R MIC, PERFORMED ADJUSTMENT TEST IAW MM, OPERATIONS CHECKED GOOD.SDR CALA2013120293374Unknown · malfunctionedBCL 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. ELECTRIC PFR SHOWS SDAC1 NO DATA FROM BCL 1. SWAPPED BOTH SDAC'S, RETESTED BOTH BCL'S IAW AMM 31-50-0 0-710-001A, ALL TEST PASSED. SDAC1 MR 31541-1004, SDAC2, MR 31541 & SN 0E5006355.SDR CALA2013120293375Contactor · faultyBCL 2 FAULT DISPLAYED ON UPPER ECAM SCREEN, ELECTRIC TSM24-38-00-810-814A. REPLACED CONTACTOR 6PB2. GND SYS BITE TESTED GOOD.SDR CALA2013112693277Pump · leakingNR 1 CTR FUEL PUMP LEAKING. REMOVED NR 1 CTR FUEL PUMP REPLACE O-RING SEALS & PUMP, LEAK CHECKED GOOD IAW MM.SDR CALA2013112593250Screw · looseSCREW LOOSE ON PANEL 192KB. SCREW & NUT PLATE NEED TO BE REPLACED. IAW AMM REPLACED NUTPLATE & SCREW.SDR CALA2013112593223Converter · faultyLT WINDSHIELD WIPER INOPERATIVE ANTI ICE. CAPTAIN`S WIPER WOULD NOT TURN OFF, CB PULLED. REPLACED CAPTAIN`S WIPER MOTOR CONVERTER IAW MM, OPERATIONS CHECKED OKAY.SDR CALA2013112293204Strut · lack of lubeDURING TAXI CREW REPORTS GROANING SOUND FROM NLG AREA. NEED TO PERFORM LUBRICATION OF THE INNER PART OF THE NLG SHOCK STRUT. 5 CYCLE LIMIT OK TO CONTINUE.SDR CALA2013112593224Oxygen System · low pressureCREW OXY SYS LOW RECORD PRESS PRIOR TO SERVICING. SERVICED CREW OXY IAW AMM 12-14-35 OXY FLOW NORMAL. OK FOR SERVICE.SDR CALA2013112593225Radar · faultyWXR INOPERATIVE, FLIGHT DIVERTED. REPLACED WXR IAW AMM. OPERATIONS CHECKED NORMAL IAW BITE TEST OF THE WXR TASK 34-41-00-740-002A.SDR CALA2013112593226Screw · looseCAPTAIN`S TRIGGER SWITCH ON CONTROL STICK IS LOOSE. TIGHTENED CAPTAIN`S TRIGGER SWITCH MOUNT SCREW.SDR CALA2013112193148Warning System · activatedENG ANTI ICE MESSAGE ON UPPER ECAM.SDR CALA2013112093111Control Unit · faultySDCU MESSAGES REPEAT LEVEL 1 CHRONIC SDCU NO DATA MESSAGES. PROBLEM STARTED AFTER THE LAST SDCU WAS INSTALLED, OCCURS ON ENG START. REPLACED THE SDCU PCN 565-9019 IPC 26-17-08-02-130E AMM 26-17-34-401, SYSTEM CHECKED OK.SDR CALA2013112093142Structure · damagedFWD GALLEY FLOOR IS AN AREA 1 FT SQ SECTION. AREA IS APPROXIMATELY 7 INCH BY 5 INCH. MADE TEMP REPAIR IAW SRM 53-02-00.SDR CALA2013112093143Coffeemaker · dirtyTHE INBOUND CABIN CREW REPORTED TO CUSTOMER SVC THERE WAS AN ELECTRICAL BURNING SMELL IN THE CABIN. NO LOCATION & NO WRITE UP WITH NO SMOKE IN CABIN REPORT INITIATED. THE FLIGHT ATTENDANT WHO REPORTED THE BURNING SMELL RETURNED TO THE ACFT TO POINT OUT THE LSDR CALA2013112093109Coupling · misalignedFUEL CAP MISSING ON WALK AROUND. FUEL SHEET WAS ALREADY ON BOARD. REFUEL-DEFUEL COUPLING ELEMENT ASSEMBLY MISALIGNED. REALIGNED COUPLING IAW AMM. REPLACED FUEL COUPLING CAP.SDR CALA2013112193188Paint · chippedRADOME HAS NUMEROUS PAINT CHIPS.SDR CALA2013111993046Controller · faultedCHRONIC RIGHT WINDOW HEAT. ACCOMPLISHED RESISTANCE CHECK, FOUND BETWEEN LIMITS ALSO ACCOMPLISHED RESISTANCE CHECK OF WINDSHIELD SENSORS BETWEEN LIMITS REPLACED NR 2 WINDSHIELD HEAT CONTROLLER. ACCOMPLISHED OPS TEST, NO MESSAGES ON ECAM OR CFDS TEST OKAY.SDR CALA2013111893016Actuator · unknownR & R NR 4 SPOILER ACTUATOR IAW AMM27-64-44. ADJUSTED RT NR 4 SPOILER ACTUATOR IAW AMM 27-64-00. OPERATIONS & LEAK CHECKED GOOD.SDR CALA2013111893018Actuator · faultyHYD LEAK ON RT WING FLAP AREA. FOUND RT SPOILER ACTUATOR LEAKING 13 DROPS PER MIN. SEE 0266010 FOR RT WING NR 4 SPOILER ACTUATOR REPLACEMENT. OPERATIONS & LEAK CHECKED GOOD IAW AMM.SDR CALA2013112093141Seal · defectiveNR 1 ENG IS PROFUSELY LEAKING OIL ON THE GND IN 2 SPOTS, 1 LARGE & 1 SMALL PUDDLE. FOUND OIL CAP SEAL TO BE DEFECTIVE. REPLACED SEAL NR 1 COWLING SECURED CLOSED.SDR CALA2013112193149Brake · damagedHOT BRAKES, REPLACED NR 3 MLG BRAKE IAW A319 AMM 32-42-27-000-001-C AND 32-42-27-400-001-A.SDR CALA2013111892981Power Supply · faultyEPSU INTERNAL LOAD EMERGENCY RT & EPSU UNIT EMERGENCY LIGHT FAULTS WHEN PERFORMING EMERGENCY LIGHTS CHECK IAW 2SV. REPLACED BATTERY PWR SUPPLY 12L RT SIDE, OPERATIONS CHECKED SYSTEM & OPERATIONS CHECKED NORMAL.SDR CALA2013111893013Tab · out of positionRED PLASTIC HANGING OUT OF CEILING AT 25B MAY BE OXYGEN MASK PROBLEM. SECURE TAB, FOUND O2 DOOR CLOSED.SDR CALA2013111893015Switch · sticksCAPTAIN`S PTT SWITCH ON SIDE STICK IS STICKING. REPLACED CAPTAIN'S CONTROL HANDLE.SDR CALA2013111893017Fastener · missingONE FASTENER MISSING ON PANEL JUST AFT OF 192KB. REPLACED FASTENER ON 192KB PANEL IAW AMM.SDR CALA2013112193151Access Panel · damagedRAMP REPORTS RT AC BAY ACCESS PANEL LE HAS MATERIAL MISSING.SDR CALA2013111492947Oxygen Mask · damagedFIRST OFFICER'S OXYGEN MASK HAS EXPOSED WIRING, CONDUIT HAS SEPARATED FROM MASK. REPLACED FIRST OFFICER'S OXYGEN MASK IAW AMM 35-12-41-000-002-A & 35-12-41-400-002-A.SDR CALA2013111592969Unknown · leakingNR 1 ENG PIECE OF RUBBER HANGING FROM BOTTOM OF COWLING & FLUID DRIPPING SAME AREA. IAW MM78-31-00-710-041 F0R OPERATIONAL CHECK OF REVERSER VIA CFDS. TROUBLE SHOOTING TO POSSIBLE LEAK ON NR 1 ENG RT LOWER THRUST REVERSER ACTUATOR. LOCKED OUT NR 1 THRUST RESDR CALA2013111592971Switch · sticksCAPTAIN`S CONTROL STICK TRIGGER SWITCH IS STICKING IN TRANSMIT POSITION. REPLACED CAPTAIN`S SIDE STICK HAND GRIP ONLY IAW MT 23-012, OPERATIONS TEST IAW AMM.SDR CALA2013111592972Cover · missingNR 2 FLAP TRACK MISSING BOLT COVER. INSTALLED BOLT COVER AT FLAP NR 2 ALL OK.SDR CALA2013111492948Connector · unsecureEMERGENCY LIGHT, EPSU INT LOAD EMERGENCY LIGHT, EPSU EXT LOAD FWD LT MED 1R SLIDE REPLACED. RESEATED CONNECTOR ON EMERGENCY LIGHT POWER SUPPLY, MID CABIN LT SIDE.SDR CALA2013111893014Hydraulic Line · leakingHYDRAULIC LEAK BELLY AFT CARGO DOOR AREA, YELLOW SYSTEM SERVO LINE.SDR CALA2013111492937Liner · damagedENG 1 INLET LINER HAS APPROXIMATELY 1-2 IN HANGING DOWN LOOSE AT 12 O'CLOCK POSITION.SDR CALA2013111492938O-Ring · damagedYELLOW SYS HYD LEAK AT AFT WALL MAIN WHEEL PTU MODULE. REPLACED O-RING ON THE YELLOW HYD SYS PTU MANIFOLD ASSEMBLY CHECK VLV, PN NAS 1612-20. SEE AIRBUS IPC 29-13-15-02A. LEAK CHECK YELLOW SYS PTU MANIFOLD ASSEMBLY, NO LEAKS FOUND.SDR CALA2013111492939Acoustic Liner · damagedNR 2 ENG ACOUSTICAL PANEL CHUNK MISSING 6 O'CLOCK WITH ANOTHER SMALLER PIECE LOOSE. INSPECTED FAN CASE ATTRITION LINER IAW MT72-017 REV E. REMOVED LOOSE PIECE OF LINER APPROXIMATELY 0.250 INCH DIAMETER. DAMAGE IS LESS THAN 20% OF PANEL & TO BE REPAIRED WITHSDR CALA2013111492940Computer · faultyHORN SOUNDING, AVIONIC VENT SYS FAULT, NO DATA FROM AEVC. REPLACED AEVC IAW AMM, SYS OPERATIONS CHECKED NORMAL, FAULT CLEARED.SDR CALA2013111492941Panel · unsecureAFT PIT FLOOR HAS A DEFECT THAT NEEDS CLARIFICATION. SECURED SIDE WALL PANEL AFT PIT. NO DEFECTS NOTED TO FLOOR.SDR CALA2013111392888Tire · damagedCHUNK OF RUBBER MISSING FROM LT NOSE WHEEL, CORD SHOWING. REPLACED TIRE IAW AMM.SDR CALA2013111292848Gcu · malfunctionedPOWER INTERMITTENT WHILE ON APU GEN. PLACED APU GEN ON MEL DUE TO HISTORY. APU GEN SWITCH OFF. REPLACED APU GCU IAW AMM, CHECKED GOOD THROUGH CFDS.SDR CALA2013111292849Flap · dentedLARGE DENT IN FLAP JUST INBD OF ENG 1 PYLON. DENT IS 1.5 IN WIDE, .030 IN DEEP. ACCOMPLISHED HFEC IAW NDT M PT6 51-10-08, NO CRACKS INDICATED. IAW SRM 57-52-00 PG 135 FIG 117. 2" DIAM DENT, .030 DEPTH, LOCATED 5" INBD OF LT INBD FLAP TRACK & 7" FWD OF TE. SDR CALA2013111292850Antenna · defectiveVHF 1 RADIO INOPERATIVE. REPLACED VHF 1 ANTENNAE IAW MM. PERFORMED OPERATIONAL CHECK.SDR CALA2013111292873Battery · faultyEPSU EMERGENCY AFT LEFT DISPLAYED AFTER EMERGENCY LIGHT TEST. INSTALLED NEW EPSU BATTERY POS LEFT AFT, OPERATIONS TESTED NORMAL.SDR CALA2013111292851Actuator · faultyELAC 2 INOPERATIVE. ECAM F CTL ELAC 2 PITCH FAULT RESET TWICE CAME BACK AFTER 1 MIN EACH TIME. IAW TSM 27-93-00-810-836-A REPLACED PITCH TRIM ACTUATOR IAW AMM 27-44-57-000-001-A & GROUND CHECKED NORMAL.SDR CALA2013111292852Seal · damagedAFT MLG WW GEAR DOOR SEAL MISSING APPROXIMATELY A ONE INCH CHUNK. RT MLG, RT GEAR DOOR SEAL CHECKED NORMAL.SDR CALA2013111292853Hook · faultyR2 DOOR HANDLE WILL NOT LOCK IN THE OPEN POSITION WHEN THE DOOR IS OPEN. REMOVED THE DOOR GEARBOX, REPLACED THE HOOK & REINSTALLED IAW AMN. OPERATIONS CHECKED OK.SDR CALA2013110892756Control Panel · faultyVHF2 INOPERATIVE. REPLACED ACP & SWAPPED VHF2 TO VHF3 IAW TOMC. CREATED TWO DF ITEMS DF744 & DF745.SDR CALA2013110892757Unknown · malfunctionedUNABLE TO COOL COCKPIT BELOW 86.
Back to IAE V2522-A5