SDR CALA2013121693756Servo Valve · faultyELAC 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. REPLACED LT GREEN ELEV SERVO CONTROL SERVO VLV 34CE1 REF 27-34-51, OPERATIONS CHECKED NORMAL.SDR CALA2013121693738Sensor · inoperativeLGCIU 2 INOPERATIVE LG. REPLACED RT MLG EXT SENSOR 22GA, OPERATIONS CHECKED GOOD.SDR CALA2013121693713Computer · faultyELAC 2 PITCH FAULT DISPLAYED ON ECAM WITH ENGS RUNNING & FLIGHT CONTROLS OPERATED. REPLACED ELAC 2 & COMPLETED ASSOCIATED GND TESTS, INDICATIONS NORMAL. LAND TEST ACCOMPLISHED ON CF324. REPLACED RT YELLOW ELEVATOR SERVO UNIT & RIGGED IAW 27-34-00-82 0-003-BSDR CALA2013121693720Stringer · corrodedAFT CARGO COMPARTMENT BILGE AREA FRAME 61- 63 STRINGER 41RT HAS CORROSION. R & R STRINGER & ATTACHING PARTS IAW A319 SRM 53-00-13 FIG 201 SHEET 1-5.SDR CALA2013121693755Sensor · faultyLGCIU 1 FLT, REPLACED 24GA PN 8-933-0 1FS.SDR CALA2013121393686Sliding Window · arcedARCING ALONG TOP OF CAPTAIN`S SLIDING SIDE WINDOW. REPLACED CAPTAIN`S SLIDING WINDOW.SDR CALA2013121393687Shoulder Belt · frayedFLIGHT ATTENDANT`S SHOULDER STRAP AT FWD JUMP SEAT IS FRAYED. REMOVED & INSTALLED FLIGHT ATTENDANT`S SHOULDER STRAP FWD INBD JUMP SEAT, OPERATIONS NORMAL.SDR CALA2013121393688Control Cable · lack of lubePITCH TRIM IS STIFF & BINDING. PITCH TRIM SYS OPERATIONS NORMAL. INSPECTED & LUBED REAR THS CONTROL CABLE IAW MM PRECAUTIONARY.SDR CALA2013121693714Nut · damagedFASTENER ABOVE LT WING ESCAPE SLIDE PANEL ONE OUT. REPLACED CAPTION NUT & FASTENER.SDR CALA2013121693715Screw · looseSCREW ON OUTSIDE OF NR 2 ENG PYLON STICKING OUT. PROBABLY SAME SCREW AS YESTERDAY. SECURED STICKING OUT FASTENER. COULD NOT ASCERTAIN CONDITION OF THIS FASTENER YESTERDAY.SDR CALA2013121693717Tape · peelingIAW CF949 TAPE IS PEELING BADLY FROM REPAIR IN NR 2 ENG BYPASS SECTION. RESTORED TEMPORARY REPAIR, OK TO CONTINUE. TAPE PEELING FROM NR 2 ENG C DUCT PREVIOUS DEFERRED.SDR CALA2013122093837Wire · damagedNR 1 ENG LOOP SQUIB TEST FAILED. NR 1 SQUIB LIGHT DOES NOT ILLUMINATE. FOUND WIRE PULLED OUT OF A SPLICE REPAIR 10 INCHES FROM CONNECTOR 5WE1-A. REPLACED WIRES 2621-20, 2621-19, 2621-73 & 2621-21 ALONG WITH CONDUITS. WORK ACCOMPLISHED ON OV WU W0976G, W099SDR CALA2013121693690Stringer · damagedFWD CARGO BAY STRINGER 41RT, FRAMES 28 - 29 REPAIR HOLES ELONGATED. R & R STRINGER IAW SRM 51-42-11, PARA 7, FIG 9, PG 27.SDR CALA2013121393657Cable · faultyEXIT DOOR 2R ARMING HANDLE DIFFICULT TO MOVE, FULLY OPERABLE. REPLACED DOOR 2R ARM FLEXIBLE CONTROL CABLE.SDR CALA2013121293636Connector · looseNW STEER FAULT DISPLAYED ON UPPER ECAM SCREEN, WHEEL. 2 OCCURRENCES, RESET PROCESS APPLIED OK BUT THEN FAULTED AGAIN, ITEM ROLLED FORWARD. CFDS FAULT STEERING ELECTRO HYD MODULE 6GC, 6GC PCN 644-9554. CHECK ELECTRIC CONNECTOR ON 6GC FOR WATER CONTAMINATION.SDR CALA2013121293637Wire Harness · faultyEMERGENCY LIGHT TEST FAILED, INTERIOR LOAD AFT LT. REPLACED WIRE HARNESS FOR SEAT 34C, EMERGENCY LIGHT TEST IS OKAY.SDR CALA2013121393685Sensor · faultyLGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN LG. R & R 26GA FAULT REMOVER, OPERATIONS NORMAL.SDR CALA2013121893786Sensor · malfunctionedLGCIU 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. CYCLED CB LGCIU SYS 2 IAW FM RESET PROCEDURE, ECAM STILL DISPLAYED. REPLACED SW 23GA IAW AMM 32-31-73 ALL MESSAGES CLEARED, AC RETURNED TO NORMAL. ECRA 3231-01117 CREATED FOR FERRY FLT TO MAINT BAS FOR GEAR EXTESDR CALA2013120993575Girt Bar · faultyORANGE GIRT BAR INDICATOR AT BOTTOM OF DOOR 2R IS NOT VISIBLE, DOOR SHOWS ARMED. R & R GIRT BAR IAW AMM CH 25-62-44-400-006-A, OPERATIONS CHECKED GOOD.SDR CALA2013120993579Stringer · corrodedAFT PIT FUSELAGE STRINGER 44 CORRODED BETWEEN FR 62 - FR63. REPAIR ACCOMPLISHED IAW SRM 53-00-13 FIG 201, SHEET 3. WORK ACCOMPLISHED ON NR 25440.SDR CALA2013121393648Pump · failedENG FAILED 2 MINUTES AFTER START, NO OTHER INDICATIONS. ENG AUTO SHUTDOWN SEE PL 7436002 FOR REPLACEMENT OF NR 2 ENG LOW - HIGH PRESS FUEL PUMP. NR 2 ENG OPERATIONS & LEAK CHECKED GOOD.SDR CALA2013121393649Gasket · looseGASKET CAME LOOSE ON ENG 2, INBD SIDE, FLT DIVERTED. NR 2 ENG INBD SIDE SEAL BETWEEN CNA & C DUCT LOOSE. ACCOMPLISHED INTERIM REPAIR IAW ECRA 7811-01208.SDR CALA2013121393650Stringer · corrodedAFT PIT FUSELAGE STRINGER 44 CORRODED BETWEEN FR 62 - FR 63. REPAIR ACCOMPLISHED IAW SRM 53-00-13 FIG 201, SHEET 3.SDR CALA2013120993555Seal · unsecureRUBBER SEAL HANGING FROM NR 1 ENG REVERSER. CNA OUTER SEAL OUT OF RETAINER APPROXIMATELY 3.5 FT 9 O’CLOCK POSITION. SECURED SEAL & APPLIED RTV 732.SDR CALA2013120993549Tire · out of toleranceEXCESSIVE SHIMMY ON NOSE GEAR ON TAKEOFF. SUSPECT ONE OR BOTH TIRES OUT OF ROUND. R & R BOTH NOSE TIRES & LUBED GEAR. SN ON 8407P & LEFT 8720P, OK TO CONTINUE.SDR CALA2013120993553Exhaust Duct · damagedAFT BURNER SECTION OF THE 2 ENG SEPARATING. IAW MT 78-005 DAMAGE IS IN C DUCT NOT HOT SECTION AT 3 O'CLOCK AS VIEWED FROM REAR IAW TEP 2 C 2. REMOVED DAMAGE 15 X 1 & TAPED, OK TO CONTINUE.SDR CALA2013120993554Cover · unsecure2R SLIDE COVER NEEDS R & R. SECURED COVER IAW MM 25-61-001 OK TO CONTINUE.SDR CALA2013120993557Seal · looseRT ENG HAS LOOSE BULB SEAL PROTRUDING FROM INBD FWD OF CNA. SECURED LOOSE SEAL INTO RETAINER TRACK.SDR CALA2013120593487Placard · unknownEMERGENCY OXYGEN CONTAINER AT ROW 10ABC NEEDS PERMANENT INSTRUCTIONS PLACARDS. NO PARTS AT MEXJL, INSTALLED INTERIM PLACARDS. INSTALLED PERMANENT DECAL.SDR CALA2013120693527Oxygen Mask · deployedO2 MASK DEPLOYED 29ABC. RE-STOWED MASKS IAW MT35-003.SDR CALA2013120693528Proximity Sensor · faultyECAM LG SYS DISAGREE. REPLACED PROX SENSOR 27GA IAW AMM.SDR CALA2013120993548Sensor · faultyLGCIU 1 FAULT DISPLAYED ON UPPER ECAM. REPLACED SENSOR 21GA IAW MM 32-31-73-400-001-1. CHECKED ADJUSTMENT IAW 32-31-73-200-001-A & PERFORMED BITE CHECK OF LG IAW 32-69-00-740-001, ALL CHECKED GOOD AT THIS TIME.SDR CALA2013120593488Pump · leakingFOUND BIG PUDDLE OF OIL UNDER NR 2 ENG. SERVICED WITH 4 QTS OF OIL. RAN NR 2 ENG & FOUND A PIN HOLE SIZE STREAM OF OIL COMING OUT OF THE SIDE OF THE OIL PUMP ASSEMBLY. R & R OIL PRESS PUMP & FILTER ASSEMBLY IAW MM. OPERATIONS & LEAK CHECKED GOOD AT THIS TISDR CALA2013120693529Start Valve · malfunctionedUNABLE TO OPEN ENG 1 START VLV DURING NORMAL START ATTEMPT NR N2 ROTATION. REPLACED NR 1 ENG START VLV & STARTER, OPERATIONS CHECKED NORMAL.SDR CALA2013120593485Pump · leakingFLUID SEEP ON WALK AROUND. FOUND PUMP 37-QA LEAKING. REMOVED PUMP IAW AMM 28-21-51-000-002-A & INSTALLED PUMP IAW AMM 28-21-51-400-002-1 THRU STEP B 8. INSTALL PROC COMPLETED SEE SEQ 9562004.SDR CALA2013121193593Wire · brokenNR 1 PYLON FIRE EXTINGUISHER BOTTLES BAY. FWD BOTTLE DISCHARGE CARTRIDGE CONNECTOR WIRING CONDUIT IS BROKEN & WORN AT CLAMP AT RT SIDE AFT OF FWD BOTTLE BELOW HYD TUBE GANG CLAMP ASSEMBLY.SDR CALA2013120293336Sealant · missingNR 2 ENG THRUST REVERSER C DUCT SEAL, SEALANT, MISSING ON LT & RT HALF, IAW AMM MT78- 016 FOR DISPOSITION. REPAIRED SEAL ON CNA IAW MT 78-001.SDR CALA2013120593486Nose Cowl · delaminatedFOUND LARGE AREA OF DELAMINATION ON ENG 1 INLET COWL PANEL DURING WALK AROUND INSPECTION. THE FOLLOWING DIMENSIONS APPLY FOR DAMAGED AREAS, BETWEEN 6 & 7 O'CLOCK 20" X16", DELAMINATION BETWEEN 7 & 8 O'CLOCK 11" X 12", DELAMINATION BETWEEN 8 & 9 O'CLOCK 10" X SDR CALA2013120293337Solenoid Valve · malfunctionedWITH OXY CREW SUPPLY PUSHBUTTON SWITCH IN THE OFF POSITION & PRESSING ANY OXY PRESS TO TEST RESET CONTROL SLIDE SEVERAL TIMES, ON SEVERAL DIFFERENT STOWAGE BOXES, DOES NOT RESULT IN A REGULAR LOW PRESS MESSAGE. IAW NR 2 SERVICE CHECK ITEM I 7A. REPLACED SOLESDR CALA2013120293338Connector · brokenCREW O2 BOTTLE PRESS REGULATOR CONNECTOR BACKSHELL IS BROKEN & HAS SHARP EDGES. REPLACED BACKSHELL IAW WDM 35-13-01 & SPM 20-33-45 CHECKED OK.SDR CALA2013120293330Container · faultyIAW CF270 MANUAL DROP TEST, SEATS 1AB DID NOT DROP. REPLACED EMERGENCY OXY CONTAINER IAW MM 35-21-41.SDR CALA2013120293331Container · faultyIAW CF270 MANUAL DROP TEST, SEATS 10ABC DID NOT DROP. REPLACED EMERGENCY OXY CONTAINER IAW MM.SDR CALA2013120293332Oxygen Mask · malfunctionedIAW CF270 MANUAL DROP TEST, SEATS 30ABC DID NOT DROP. IAW SERVICE TIP MT35-002 REPACKED MASKS, OPERATIONS CHECKED OK.SDR CALA2013120293333Oxygen Mask · malfunctionedIAW CF270 MANUAL DROP TEST, SEATS 34ABC DID NOT DROP. IAW SERVICE TIP MT35-002 REPACKED MASKS AT SEATS 34ABC.SDR CALA2013120293334Oxygen Mask · malfunctionedIAW CF270 MANUAL DROP TEST, SEATS 34DEF DID NOT DROP. IAW SERVICE TIP MT 35-002 REPACKED MASKS AT SEATS 34DEF, OPERATIONS CHECKED OK.SDR CALA2013120293335Oxygen Mask · malfunctionedIAW CF 270 MANUAL DROP TEST, SEATS 31ABC DID NOT DROP. IAW SERVICE TIP MT 35-002 REPACKED MASKS, OPERATIONS CHECKED OK.SDR CALA2013120293339Light · faultyEMERGENCY LIGHTS TEST FROM CIDS INDICATES 33-51-38, EPSU EXTERIOR EMERGENCY RT. BITE TEST OF OVERWING 12 WL, EPSU INDICATES EXTERIOR LIGHT FAULT. REPLACED AFT FWD OVERWING SLIDE LIGHT IAW AMM 33-51-14. FWD ATTN PANEL CHECKED GOOD ALONG WITH EPSU AT RT OVERWSDR CALA2013120293388Connector · corrodedREPEAT LOG ON TAXI OUT, MULTIPLE ECAM MESSAGES RELATED TO RT MLG SENSOR 22GA. PHYSICAL INSPECTION OF SENSOR 22GA ON RT GEAR, NO OBVIOUS DEFECTS IAW PFR MESSAGE 32-31-73, 22GA TARGET POSITION SOURCE LGCIU 2, IAW TSM 32-31-00-810-842-A. MESSAGE DID NOT OCCUR USDR CALA2013120393398Converter · inoperativeLT WINDSHIELD WIPER INOPERATIVE ANTI ICE. R & R CAPTAIN'S WIPER MOTOR CONVERTER IAW AMM, OPERATIONS CHECKED GOOD. AC UPGRADED TO CAT FULL CAPABILITY IAW 22-97-00.SDR CALA2013120393399Ignition Lead · faultyAPU AUTO SHUT DOWN WITH FAULT LIGHT. R & R IGNITION UNIT & LEADS IAW AMM 49-41-38 & 49-41-31, OPERATIONS CHECKED GOOD.
Back to IAE V2522-A5