IAE V2522-A5
Service difficulty reports · 3,464
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013082090595Battery · inoperativeEPSU BATTERY R MESSAGE. REPLACED BATTERY IAW AMM.SDR CALA2013082090602Battery Pack · faultyEPSU BITE FAULTS BATTERY EMERGENCY LEFT. REPLACED BATTERY PACK LEFT OVERWING LOWER SIDEWALL, CHECKED GOOD.SDR CALA2013082090604Cover · missingUNDERWING FUEL PANEL FILL VALVE LENS COVER MISSING. REPLACED LENS COVER.SDR CALA2013081990520Window · faultyRT WINDOW DISPLAYED ON UPPER ECAM. REMOVED WINDOW AND INSTALLED NEW ONE. COMPLETED RT WINDOW INSTALLATION, OPS CHECKED GOOD.SDR CALA2013081990542Wire Harness · unknownLEFT WINDOW DISPLAYED ON UPPER ECAM SCREEN. R & R WINDOW HEAT WIRE HARNESS THAT ATTACHES TO THE WINDOW IAW AMM & STANDARD PRACTICES.SDR CALA2013081990543Sdac · unknownGREEN & YELLOW SYS LOW PRESSURE DISPLAYED ON UPPER ECAM SCREEN. REPLACED SDAC 1 IAW AMM, ALL INDICATIONS NORMAL.SDR CALA2013082090600Line · crackedFOUND CRACKED P4.9 MANIFOLD LINE AT 3 O'CLOCK POSITION. REPLACED P4.9 MANIFOLD LINE PER AMM, OK FOR SERVICESDR CALA2013081990558Seat Belt · out of position2L WILL NOT ARM. REMOVED FLIGHT ATTENDANT SEAT BELT FROM DOOR SILL. CYCLED DOOR SEVERAL TIMES, OPERATIONS CHECKED OKAY.SDR CALA2013081990544Computer · faultyDURING CRUISE FLT FELT BUMP IN TAIL AND ECAM F-CTL ELAC2 PITCH FAULT AND AIL SERVO FAULT MESSAGES APPEARED AND FELT ANOTHER BUMP AND MESSAGES CLEARED. TROUBLESHOTING & FOUND NO PEDAL MESSAGES, REPLACED ELAC 2, OPS TESTED GOOD.SDR CALA2013081990545Sdac · unknownCABIN PRESSURE 1 & 2 FAULT. R & R SDAC 1, ALL SYS TEST NORMAL.SDR CALA2013082090569Lamp · inoperativeCOCKPIT OPEN LIGHT INOPERATIVE. REPLACED LAMPS.SDR CALA2013082090603Light · inoperativeRED EMERGENCY LIGHT NEAR FIRST CLASS CLOSET INOP. MEL COMPLIED WITH. REPLACED LIGHT ASSEMBLY. OPS CHECKED GOOD.SDR CALA2013081990516Controller · faultyRT WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. ANTI-ICE RT WINDSHIELD ECAM. REPLACED IAW TSM 30-42-00-810-831, SENSORS CHECKED NORMAL. REPLACED CONTROLLER IAW MM. OPS CHECKED NORMAL FR 078 REMOVED, REV TSM TO 30-42-00-810-804-A.SDR CALA2013081990517Warning Light · no testNR 2 ENGINE, AGENT 1 SQUIB LIGHT DOES NOT TEST. LIGHT IS GOOD. OPENSDR CALA2013081990519Sump · leakingFUEL SUMP LEAK. RESEATED LT CENTER FUEL SUMP, LEAK STOPPED.SDR CALA2013082090592Actuator · leakingMAINTENANCE WALKAROUND FOUND HYD FLUID LEAKING FROM NR 1 ENGINE LOWER AFT FAN COWLING. FOUND UPPER OUTBOARD ACTUATOR LEAKING. DEACT ENGINE THRUST REVERSER SYSTEM FOR FLIGHT REF MM. STOWED AND LOCKED, NO LEAKS. FOUND THRUST REVERSER ACTUATOR LEAKING AND CHANSDR CALA2013082090593Fastener · missingFOUND TWO NOSE CONE INNER BARREL RIVETS MISSING AT THE SIX O'CLOCK POSITION. REPLACED MISSING RIVETS ON NUMBER ONE ENGINE REFERENCE MT 71-002.SDR CALA2013082090599Computer · faultyCREW REPORTED EXCESSIVE ACFT PITCH UP. AFTER TAKEOFF ACFT NEEDED FWD STICK PRESSURE. AT CRUISE SPEED CHANGES RESULTED IN LOSS OR GAIN OF ALTITUDE DUE TO SLOW TRIM RESPONSE. NOTED PITCH UP WAS MORE THAN 2.5 DEGREES PER MIN. AIRMAN SHOWS CFDS MSG "ELAC2 COM SDR CALA2013081690495Chiller · malfunctionedF/A REPORTS BEING SHOCKED ON GALLEY WHEN SWITCHING FROM EXTERNAL TO APU POWER. ISOLATED PROBLEM TO GALLEY CHILLER. COLLARED BREAKER, NO FURTHER PROBLEM WITH SHOCKING.SDR CALA2013081490439Coffeemaker · odorMELTED PLASTIC ELECTRICAL ODOR IN FWD GALLEY. REPLACED COFFEEMAKER. NO FURTHER ODOR OR ELECTRICAL SMELL IN FWD GALLEY.SDR CALA2013081690481Tire · wornA LOT VIBRATION ON NOSE WHEELS AFTER ROTATION. REPLACED BOTH NOSE TIRES IAW AMM.SDR CALA2013082290649Battery · dischargedDURING TWO SERVICE EMERGENCY LIGHT CHECK HAD EPSU EMERGENCY LIGHT MESSAGE. REPLACED EPSU IAW AMM 33- 51-38 & EPSU BATTERY IAW AMM 33-51-38. BITE TESTED GOOD ON EPSU & EMERGENCY LIGHT CHECKED GOOD AT DOOR 1L.SDR CALA2013081490438Screw · looseFUEL LEAKING FROM COUPLING. FOUND LOOSE SCREW AND TIGHTENED. OK FOR SERVICE.SDR CALA2013081490440Extinguisher · unsecureF/A REPORTS AFT GALLEY HALON FIRE EXTINGUISHER PIN UNSECURE. RESEALED AND SECURED EXTINGUISHER.SDR CALA2013081290361Receptacle · leakingHIGH PITCH SQUEAL CONTINUES. APPEARS TO BE COMING FROM BELOW INSTRUMENT PANEL. SUSPECT E & E DOOR. PRESSURIZED ACFT, FOUND LEAK AT THE EXTERNAL GROUND POWER RECEPTACLE. TORQUED RECEPTACLE REF MM. PRESSURIZED AND OPS CK GOOD.SDR CALA2013081290363Extinguisher · low pressureAFT LAVATORY WASTE BIN FIRE EXTINQUISHER NEEDLE IS IN IN RED. SMOKE DETECTOR SYS OP NORMAL LAV USABLE. R & R AFT LAV WASTE BIN FIRE EXTINGUISHER.SDR CALA2013080790201Seal · failedVIBRATION IN BELLY, FAIRINGS & PASSENGER DOORS IAW TSM 05-50-00-810-801-A. VIBRATION INSPECTION PERFORMED IAW TSM. FOUND BAD SEAL ON PANELS 192 BT AND 192 DT.SDR CALA2013080890259Extinguisher · reads lowAFT LAVATORY WASTE BIN FIRE EXTINQUISHER NEEDLE IS IN THE RED SMOKE DETECTOR SYS OPS NORMAL.SDR CALA2013080890277Tape · looseLIGHT TO MODERATE AIRFRAME VIBRATION. ON FURTHER INSPECTION, FOUND SPEED TAPE CF0044 FOR PANEL 192 IS LIFTED AND SEAL AREA WAS EXPOSED. REAPPLIED SPEED TAPE CORRECTLY AND NO OTHER DEFECTS FOUND.SDR CALA2013080890237Wire · severedNR 1 ENGINE PYLON FWD FIRE EXT BOTTLE WIRES, SEVERED 8 INCHES FROM CONNECTOR 5WE1-A. REPLACED WIRE 2621-19-DL20 2621-20-CF20 AND CONDUIT IAW AWM 26-21-01.SDR CALA2013080590170Liner · missing1.5 INCH AREA OF ACCOUSTIC MATERIAL IN NR 2 ENGINE NACELLE, MISSING. ATTRITION LINER AT 6 O'CLOCK POSITION HAS A 1.5" X BY 1.750" PIECE MISSING FROM NR 2 ENG. REPAIR MUST BE ACP WITHIN 20 CYCLES MT 72-017.SDR CALA2013080890238Placard · missingROWS 29D, 28E, 26E MISSING LIFE VEST UNDER SEAT PLACARD. REPLACED PLACARDS.SDR CALA2013082290683Seal · lack of lubeDOOR 1L VERY LOUD SQUEAL DURING CLIMB. LUBED DOOR SEAL & RETAINER.SDR CALA2013082090615Thermostat · failedNR 1 PRECOOLER TEMPERATURE IS 105 DEGREES AND YELLOW. AIRMAN SHOWS CFDS FAULT "FAN AIR-V 9HA1 OR THRM 7170 HM1". REMOVED & REPLACED THE FAN-AIR VALVE CONTROL THERMOSTAT PER AMM 36-11-43. RAN ENGINE, ALL INDICATIONS NORMAL. NO LEAKS NOTED. NO MESSAGES PRESENSDR CALA2013072990031Oxygen Mask · leakingSECONED OBSERVER`S, O2 HARNESS LEAKING. R & R MASK IAW MM LEAK AND OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR CALA2013073090084Wire Harness · inoperativeROW 28C, EMERGENCY LIGHT INOPERATIVE. REPLACED WIRING HARNESS, 7260VC2-A, TESTS OK.SDR CALA2013073090067Sliding Window · leakingF/O SLIDING WINDOW LEAKING WATER. EXCESSIVE WATER ON RT CONSOLE. PRESSURIZED ACFT AND NO LEAKS AT 406 PSI DIFFERENTIAL.SDR CALA2013073090066Pump · leakingGREEN SYS LOW LEVEL ECAM, FLT DIVERTED, MESSAGE FOLLOWED BY SYS LOW PRESSURE, VERIFIED HYD QTY WAS AT ZERO. REPORTED BY CREW. REPLACED NR 1 ENG HYD. PUMP, OPS, LEAK CHECKED GOOD. ALSO REPLACED NR 1 ENG HYD PRESS SWITCH AND CASE DRAIN FILTER. FOUND FILTER CLSDR CALA2013073090068Oxygen Mask · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). RT RELEASE LEVER ON CAPTS O2 MASK BROKE OFF. CONT O2 FLOW UNLESS LT DOOR CLOSED AND SYS IS RESET. REPLACED CAPTS O2 MASK.SDR UALA2013072505233Computer · faultyFLIGHT CONTROL ELAC 2 FAULTED. LOSS OF THE RECEPTION OF ELAC 2 DISCRETES BY 1 FAC OR 1 FMGC. REPLACED FCDC2 AND TESTED IAW MM 27-95-34-400-001-A, NO FAULTS NOTED.SDR UALA2013072405215Connector · unsecureFWD CARGO DOOR OPEN ECAM OCCURRED TWICE. CABIN PRESSURE INDICATIONS NORMAL. FOUND CONNECTOR FOR DOOR INDICATION AT LOWER FWD CARGO DOOR SILL LOOSE. SECURED AND CLAMPED. OPS CHECKED NORMAL.SDR UALA2013072405193Igniter · failedDURING NR 1 ENGINE START, USING 'B' SYS, HAD ENGINE START FAULT, ENGINE IGNITION FAULT. GOOD START USING MANUAL START PROCEDURE. R & R NR 1 ENGINE IGNITOR PLUG "B" IAW TSM 74-00-00-810-813-A. ENGINE NR 1 STARTS WITH NO FAULTS.SDR UALA2013072305163Windshield · faultyRT WINDSHIELD ANTI-ICE DISPLAYED ON UPPER ECAM SCREEN. RT WINDOW HEAT INOPERATIVE. REPLACED WINDSHIELD ASSY IAW AMM REF AMM 56-11-11-400-001-A . OPS CHECKED GOODSDR UALA2013071905093Line · leakingFLUID LEAK ON LEFT TAIL NEAR STAB AND APU INLET. OPENED TAIL AND SECURED LINES ON RUDDER SERVO CONTROL ACTUATORS. SERVICED HYDRAULIC SYSTEMS AND PERFORMED HYD ACTUATOR LEAK CHECKS IAW AMM. LEAK CHECKED GOOD. NO LEAKS NOTED.SDR UALA2013071905094Structure · crackedRIGHT AC PACK RAM AIR EXHAUST DUCT OUTLET VERTICLE SIDE WALLS ARE CRACKED. REPLACED RT AC PACK RAM AIR OUTLET FLAP IAW AMM. FLAP ACTUATOR NEEDS TO BE INSTALLED IAW AMM 21-61-52.SDR UALA2013071905095Door · crackedLT A/C PACK DOOR HAS A 4 INCH CRACK ON THE INBD SIDE. REMOVED LT AC PACK RAM AIR OUTLET ASSY IAW AMM FOR WELDING REPAIR.SDR UALA2013071905096Sleeve · burnedCARBON FIBER PEELING ON LOWER PORTION OF NR 1 ENGINE. NR 1 ENGINE SLEEVE HAS APPROX 1.25 X 4.0 INCHES BURNED AREA WITH NO SKIN MISSING MATERIAL, REPAIRED REF MT78-024.SDR UALA2013071604996Seal · unsecureDURING CLIMB, FELT STEADY OSCILLATING BUFFET IN AIRFRAME. SECURED RT AFT NLG DOOR SEAL & LUBED DOOR GIMBAL JOINTS.SDR UALA2013071705028Computer · malfunctionedRT OUTER TANK HI TEMP DISPLAYED ON UPPER ECAM SCREEN. FUEL LT OUTER TANK TEMP 22 RT OUTER TANK TEMP 64 BOTH NORMAL AFTER 30 SECS. RETURNED AGAIN. ACCOMPLISH CHRONIC REVIEW. R & R FUEL QTY COMPUTER AND OPS CK NORMAL ON AMM 28-42-34-400-001-A.SDR UALA2013071805060Oxygen Mask · unwanted deployOXYGEN MASKS ROW 8 ABC DISLODGED. SECURED OXYGEN MASKS AT ROW 8 ABC. ACCOMPLISHED CHECK IAW AMM TASK 35-23-00-710-001, CHECKED OK.
Back to IAE V2522-A5