SDR UALA2012111906665Spinner · crackedNR 1 ENGINE NOSE SPINNER FOUND CRACK NEAR BOLT. REPLACED NR 1 ENGINE INLET CONE FAIRING PER AMM.SDR UALA2012111906668Unknown · malfunctionedENGINE 1 SLOW TO SPOOL FROM IDLE ON TAKEOFF LAGS RIGHT BY 5 SECONDS. SAMC TEXT: CHECK ENGINE ACCELERATION AND DECEL PER JRH 2-40-64. IF FAULT CONFIRMED REF TSM 73-00-00-810-880. MAINT TEXT: PER CREW VERBAL: HAPPENED TWO LEGS IN A ROW, LAST TAKEOFF ENGINE POSDR UALA2012111906635Leg Assy · excess playCFDS REPORTS 24GA AND 25GA IN FLT, CAUSING ALSO; LGCIU 1&2, AUTO FLT AP OFF, AUTO FLT A-THR OFF, L-G SHOCK ABSORBER FAULT AND STBY-ANTI ICE PROBES FAULTS. FOUND LEG ASSY SUPPORT HAVE EXCESSIVE PLAY. SECURED & SAFETY BOLD PER IPC. SECURED PER AMM 32-27-40 JASDR UALA2012111906666Pin · missingBRACKET ON AFT HALON FIRE EXTINGUISHER BROKEN. FOUND BOTTLE MISSING PIN AND SAFETY. REPAIRED BRACKET AND REPLACED MISSING PIN AND SAFETY.SDR UALA2012111906667Fastener · loosePANEL FASTENER LOOSE NEAR RIGHT PACK INLET. REPLACED NUT PLATES AND SCREWS ON PANEL 192KB.SDR UALA2012111906669Door · bindsCOCKPIT DOOR DIFFICULT TO CLOSE WHILE AIRBORNE EASY TO CLOSE ON GROUND. DOOR POSITION PER MT 52-018. LATCH OPS CHECKED GOOD.SDR UALA2012111606627Oxygen Bottle · low pressureCOCKPIT OXYGEN STARTED FLIGHT AT 930 PSI. READING 690 PSI NOW AT 0100Z AT FL 370. SERVICED OXYGEN BOTTLE TO 1700 PSI. PRESSURE IS HOLDING AND STEADY. CHECKED ALL FOUR MASK ASSYS AND BOTTLE ASSY FOR LEAKS, NONE NOTED.SDR UALA2012111606588Seat · defectiveF/O SEAT RECLINE DEFECTIVE. SEAT FALLS AFT RATHER THAN SPRING FWD. REPLACED 1ST OFFICER'S SEAT PER MM, OPS CHECKED NORMAL.SDR UALA2012111406550Battery · defectiveEMERGENCY LIGHT TEST FAILED. FAULTS EPSU AFT LEFT BATTERY. REPLACED AFT EPSU BATTERY. EMERGENCY LIGHT TEST OPS. CHECKED NORMAL.SDR UALA2012111406576Handset · intermittentINTERPHONE IS INTERMITTENT AT LOCATION NOT SPECIFIED. CREW COMMENTS: PURSER INTERPHONE INOPERATIVE. REPLACED FWD FLT ATTENDANT HANDSET, SYSTEM CHECKS NORMAL AT THE GATE.SDR UALA2012111206504Strap · tornLEATHER TIE-DOWN STRAP ON COCKPIT CRASH AXE IS TORN. REPLACED STRAP WITH NEW ONE.SDR UALA2012110806429Wire · brokenNUMEROUS BROKEN WIRES AT 7506VP CONNECTOR.SDR UALA2012110806444Control Unit · defectiveSDAC1 FAILED CAUSING MULTIPLE PROBLEMS. SWAPPED SDAC 1&2. SDAC 1 OPS NORMAL. COMPLIED WITH MEL, DF STICKER APPLIED. REPLACED SDAC NR 2 PER MM.SDR UALA2012110706417Control Unit · faultyWHEEL N-W STRG FAULT ON START OF TAKEOFF ROLL. REPLACED BSCU 10-GG PER MM. TESTED PASS AND ACP LAND 3 TEST. TEST PASS.SDR UALA2012110606378Clamp · missingHYD CLAMP FOUND MISSING JUST BEHIND THE LT MLG ACTUATOR. REPLACED HYD CLAMP BEHIND LT MLG ACTUATOR IAW AMM.SDR UALA2012110506359Controller · inoperativeRIGHT WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. - ANTI ICE. REPLACED NR 2 WHC OP CHECKS GOOD.SDR UALA2012110506327Seal · leakingG RSVR LO LEVEL DISPLAYED ON UPPER ECAM SCREEN. HYD, REPLACED O-RING SEAL ON H/P MANIFOLD GREEN SYSTEM CHECK VALVE PER AMM. LEAK CHECKED VALVE, PRESSURIZED FLIGHT CONTROLS, CYC FLIGHT CONTROLS. ACP ENGINE RUNS. NO LEAKS NOTED.SDR UALA2012110606377O-Ring · leakingECAM HYD Y RSVR LO LVL OCCURED ON DESCENT. FOUND TWO FITTINGS LEAKING ON PTU HYD MANIFOLD. RPL O-RINGS ON LEAKING, NO LEAKS NOTED AFTER REPLACEMENT OF O-RINGS. SERVICE YELLOW SYSTEM HYD AS NEEDED.SDR UALA2012110506347Seal · peelingWINDOW GASKETING ON EXTERIOR OF F/O SIDE WINDOWS PEELING OFF. WINDOWS R2 & R3 HAVE LOOSE BLACK FILM WHICH IS NOT PRESSURE SEAL OR OUTER EDGE SEAL. TRIMMED LOOSE BLACK FILM FROM WINDOWS. USED MT 56-003 AS REF TO IDENTIFY SEALS.SDR UALA2012110506348Rivet · shearedON ARRIVAL FOUND RIGHT ENGINE PYLON BLOW PANEL POPPED OPEN. INF PANEL WAS POPPED OPEN AND REMOVED TO FIND OUT WHY LEFT PYLON PANEL WAS LOOSE AND WOULD NOT SECURE CLOSED. REPLACED SHEARED RIVETS AS NEEDED IAW AMM, NO DEFECTS NOTED WITHIN AREA.SDR UALA2012110606360Sensor · faultyPER CAPT: WHEN GEAR HANDLE SELECTED DOWN, GEAR HANDLE ARROWS SCROLLED, GEAR DOORS CONTINUOUS CYCLING ON ECAM, BOTH LGCIU'S SHOWED DISAGREE, 3 REDS FOR GEAR DOWN, THE N LGCIU 1 FAULT, ECAM PROMPT "GRAVITY GEAR EXTEND". EXTENDED GEAR MANUALLY, THEN 3 GREENS FORSDR UALA2012103106281Oxygen Bottle · low pressureCREW OXYGEN SYSTEM LOW. REMOVED CREW O2 BOTTLE AND SERVICED TO 1500 PSI. REINSTALLED CREW O2 BOTTLE, NO LEAKS NOTED.SDR UALA2012103106280Skin · dentedDENT FOUND ON BELLY OF AIRCRAFT FWD OF FWD CARGO DOOR. DENT LOCATED 7.5 INCH FWD OF FRAME 24 BTWN STR 40 AND 41. MEASURES 3.5 INCH BY 2.5 INCH AND IS .050 INCH DEEP RT SIDE. INSPECTED DENT, NO CRACK INDICATION. WITHIN ALLOWABLE DAMAGE LIMITS PER SRM.SDR UALA2012103106282Plate · looseF/O SEAT PEDALS ADJUSTMENT ASSEMBLY LOOSE. TRIMMED OFF LOOSE PIECES AND APPLIED SPEED TAPE AS NEEDED. REPLACED PEDAL ADJUSTMENT ASSY PER MM. REPLACED PLATE AS PER ABOVE INSTRUCTIONS.SDR UALA2012103106279Door · unsecureLIFE VEST CONTAINER DOOR UNDER SEAT 1AB UNSECURE. SECURED DOOR.SDR UALA2012102906174Battery · failedFAILED EMERGENCY LIGHT TEST AT FAP. REPLACED BATTERIES AT FORWARD LT, RT, AND AFT.SDR UALA2012102906225Sensor · jammedFLAP HANDLE JAMMED AT FLAP 1 POSITION - TOOK SEVERAL ATTEMPTS TO GET IT TO FLAP 2, TRIGGER FLAP SLAT CONTROL LEVER AND FLAP HANDLE COMMAND SENSOR UNIT. GRND OP'S OK.SDR UALA2012102906226Oxygen Mask · deployedOXYGEN MASKS AT ROW 12DEF DEPLOYED. SAMC TEXT: REPACK AND CF FOR DROP TEST WITHIN 3D PER AMM 35-23- 00-710-001. REPACKED AND INSP PER MT 35-002 CF FOR DROP TEST PER AMM 35-23-00-710-001.SDR UALA2012102906165Pump · vibrationVERY LOUD GRINDING NOISE AND VIBRATION COMING FROM FLOOR NEAR ROW 20. POSSIBLE PUMP MAINT TEXT: RAN HYD PUMPS AND ISOLATED FOUND WITH BLUE OVRD. PUMP ON-SEVERE VIBRATION AND NOISE BY ACCESS PANEL 195BB. (SUSPECT NEEDS BLUE HYD PUMP.) REPLACED BLUE SYSTEM HSDR UALA2012102906166Oxygen Mask · misinstalledCREW REPORT: OXY MASK ON WRONG AT OXY BOTTLE OVER 1A. RE-INSTALLED MASK TO PROPER POSITION.SDR UALA2012102506100Bearing · frozenHORZ STAB TO THS ACTUATOR RIGHT FITTING BEARING IS LOOSE IN FITTING, APPEARS BEARING IS FROZEN. REF IPC 55-16-36- 01 ITEMS 60, 80, 50, 40, 10, 20. SECURE RIGHT BUSHING ASSY, BEARING OK. REPLACED LEFT BEARING DUE TO BEING LOOSE.SDR UALA2012102206037Transformer · faultySMOKE IN COCKPIT. REPLACED TRANSFORMER, CHARGE LIMITER & BATTERY (P/N AD-2728 - SERIAL# 762 - POSIT BT2).SDR UALA2012102206039Slat · damagedBIRD STRIKE RIGHT WING SLAT OUTBOARD OF NR 2 ENGINE. ACCOMPLISHED ECRA 5743-01 130 PERFORMED INTRIM REPAIR WITH FAST WELD AND TAPE ACCOMPLISHED HIGH FREQ EDDY CURRENT. ACCOMPLISHED INSPECTION, FOUND OK.SDR UALA2012102306074Wheel · vibrationNOSE LANDING GEAR VIBRATION DURING TAKEOFF ROLL. HEAVY VIBRATION ON TAKEOFF, LITTLE AT 70 KNOTS AND LOTS AT V ROTATION. REPLACED BOTH NLG WHEEL ASSY FOR REMOVAL AND REF 32-41-12-400- 001-A FOR INSTALLATION.SDR UALA2012102206014Battery · faultyON 3 SERVICE FOUND AFT OVERHEAD EMERGENCY LIGHT BATTERY FAULT AT DOOR 2L. REPLACED AT DOOR 2L OVERHEAD EMERGENCY LIGHT BATTERY, GROUND TEST EMERGENCY LIGHT TEST OKAY.SDR UALA2012102306090Valve · failedHPV VALVE TEST FAILED. REPLACED HP BLEED VALVE ACP.SDR UALA2012101905985Unknown · malfunctionedCABIN EMERGENCY LIGHTS FAILED TEST. 'EPSU INT LOAD FWD L' MESSAGE DISPLAYED. RESET EPSU AND OP CHECK SATISFACTORY, CORRECTION RESET C/B AND OP-CHECK SATISFACTORY.SDR UALA2012101805952Wire · shortedREV FAULT LEFT ENGINE. PARTIALLY COMPLETED FOUND SHORT FROM 4004VC PIN 6 TO 4000VC PIN 9, CAN ONLY SEE SHORT TO GROUND WITH THE MEGGER. REF AWM 71-51-11 AND TSM 78-30-00-810-8 37-B. ACP WIRE CHK ON RT UPPER ACTUATOR REF. TSM 78-30-00-810-80 -A AND FOUND NO DSDR UALA2012101805954Blade · out of toleranceENG2 FAN BLADE CHG OUT OF TIME. BLADE REPLACED AFTER BLADE DISTRIBUTION PERFORMED. ACP VIB SURVEY AND VIBS WERE WITHIN LIMITS.SDR UALA2012101705919Seal · vibrationAIRFRAME VIBRATIONS. FLIGHT DIVERTED. CREW REPORTS WITH CLEAN AIRCRAFT CONFIG AND CLEAR AIR ON CLIMBOUT 340KTS FL 260 ENCOUNTERED MODERATE AIRFRAME VIBRATIONS. PULLED POWER BACK & VIBRATIONS CEASED 300KTS. CREW FILLED OUT VIBE REPORT. UNABLE TO ISOLATE VIBSDR UALA2012101605890Display · faultyUPPER ECAM SCREEN COLORS ARE NOT CALIBRATED. REPLACED UPPER ECAM DISPLAY UNIT, OPS TESTED GOOD.SDR UALA2012101705934Transformer · faultyINOP LIGHTS ARE APU MASTER, APU START, DITCHING, CAB PRESS MODE SEL, EMERGENCY EXIT, ETC. -TS, CLEANED & CHECKED CONNECTORS AT 25VU OVERHEAD PANEL, TRIED ANOTHER 7LP ANN & INTC CARD, SAME RESULTS. RE-INSTALLED SAME 7LP INTC CARD. SUSPECT BAD ESS XFMR 35LP PESDR UALA2012101705917Battery · failedCABIN EMERGENCY LIGHT CHECK EPSU BATTERY AFT L FAILED. REPLACED BATTERY AT AFT LEFT POWER SUPPLY UNIT AND OPS CHECKED OK.SDR UALA2012101705916Oxygen Mask · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). REPLACED F/O O2 MASK PER AMM.SDR UALA2012101505877Drain · cloggedAFT GALLEY CARPET SOAKED. SOURCE UNKNOWN. INSPECTED FOR LEAKS AROUND NR 3 GALLEY, FOUND THE DRAIN FOR THE G3 CHILLER CLOGGED AND LEAKING IN COMPARTMENTS 301, 302, 303, THE CENTER AISLE, AND AFT RIGHT ROW OF SEATS. CLEANED CARPETS WITH WET-VAC AND MOPPED UP SDR UALA2012101205806Slide · crackedRIGHT OVERWING SLIDE PANEL IS CRACKED ON AFT EDGE. SLIDE REMOVED AND PUT IN REAR PIT ALSO SEAL ATTACH PLATE AND HARDWARE ARE IN PIT. INSTALLED SERVICEABLE OFF-WING SLIDE.SDR UALA2012101205819Panel · damagedINTERIM REPAIRS TO AFT LAV PANEL COMPLETED PER ECRA 534101022. WELDING REPAIR LOOKS GOOD AND MEETS ECRA 534101022. ACP NDT PER 51-10-21 INTERNAL AND EXTERNAL INSPECTION FOUND NO CRACKS. ACP INTERNAL HFEC AND OPEN HOLE INSPECTIONS NO CRACKS FOUND.SDR UALA2012100805663Scuff Plate · damagedRAMP REPORTS DAMAGE IN AFT PIT. SECURED RIGHT SIDE AT DOOR SCUFF PLATE REF MT 53-016.SDR UALA2012100805668Power Supply · failedDURING EEL TEST FAILING WITH MSG. EPSU FWD L BATTERY. REPLACED POWER SUPPLY PER AMM, RETESTED GOOD. P/N AD-3214-30.SDR UALA2012100905712Computer · faultyELAC 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. - F-CTL REPLACED ELAC 2.
Back to IAE V2522-A5