IAE V2522-A5
Service difficulty reports · 3,465
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010021500570Mount · faultyRT FWD PAX ENTRY DOOR - EVACUATION SLIDE LWR AFT - EVAC. SLIDE ATTACH - MOUNT IS CRACKED - APPROX. 1 IN. LONG. EVACUATION SLIDE REPLACED IAW OV WU J7571B BY AMT IAW JC 4R2592053 SEQ. 467.SDR UALA2010021600602Fitting · strippedCREW 02 FITTING STRIPED, UNABLE TO SERVICE 02. REPLACED FILL PORT AND SERVICED.SDR UALA2010021600590Power Supply · faultyBURNING ELEC ODOR NEAR ROW 13. TURNED OFF CAB FANS AND ODOR DISSIPATED. FOUND READING LIGHT POWER SUPPLY ABOVE 15 DEF INOP. POWER SUPPLY IS DEACTIVATED AND SECURED. CALL LIGHTS OKAY. READING LIGHTS AT 15DEF INOP.SDR UALA2010021200531Door · faultyCABIN - FWD GALLEY O2 MASK DOOR FAILED TO OPEN. FROM BASE W-U S1626L. CORRECTED WIRING REF WDM. REF DOCK WU S1626L. OPS CK OK.SDR UALA2010021200532Door · faultyCABIN - DR 2L O2 MASK DOOR FAILED TO OPEN. FROM BASE W-U S1627L. ADJUSTED & SECURED BOX REF DOCK WU S1627L.SDR UALA2010021200550Controller · malfunctionedF/O SLIDING WINDOW'S VISIBILITY IS IMPAIRED, GLASS IS EXTREMELY HOT DELAMINATED. POSSIBLY INFLIGHT. REPLACED THE NR 2 RT SLIDING WINDOW. CBS W13-W14 PULLED PRECAUTIONARY FOR WINDOW HEAT T-S. REPLACED WINDOW HEAT CONTROLLER. SECURED BREAKERS. OPS AND BITE CSDR UALA2010021500552Skin · puncturedFUSELAGE SKIN PUNCTURED AT 10' AFT OF FR 77, LBL 10' FROM UPPER CTR LINE. NDT WEB NO CRACK FOUND, HFEC INSPECTED NO CRACK FOUND ON INNER STRUCTURE. REPAIRED DAMAGED SKIN REF SRM. MARKED INTERNAL STRUCTURE WITH SRM & DATE REF.SDR UALA2010020500463Fire Bottle · leakingF/A REPORTS H2O FIRE EXT LEAKING. H2O BOTTLE.SDR UALA2010020300430Unknown · odorSMOKE ODOR ON FINAL FROM AREA OF ROW 16 AND AFT. NO INDICATIONS OF WHERE IT WAS COMING FROM. STRONGER ROWS 22-24 RT SIDE. CHECKED FLO LIGHT BALLASTS IN CEILING, AND SIDEWALL. PERFORMED CIDS TEST OF LIGHTS. REMOVED CEILING PANELS AT ROWS 22-23-24, NO FAULTSSDR UALA2010020300438Light · no testDOOR 1L SLIDE FAILED EMERGENCY LIGHT TEST. REPLACED NR 1L DOOR MOUNTED SLIDE.SDR UALA2010020100382Smoke Detector · false activationSMOKE LAV DET FAULT ECAM DISPLAY. REPLACED LAV A SMOKE DETECTOR. ALL TESTS PASS.SDR UALA2010012800357Heater · faultyCAPTAIN'S SLIDING WINDOW HEATING INOP. CREW COMMENTS: COLD SPOT ON LOWER FRONT CORNER. REPLACED CAPTAINS SLIDING WINDOW PANEL IAW MM. (FINAL TORQUE WAS ACCOMPLISHED) NEEDS TO BE ACCOMPLISHED TO END OF MM. COMPLETED INSTALLATION OF CAPT'S SLIDING WINDOW.SDR UALA2010012800358Strut · lack of lubeSHOCK ABS FAULT ECAM, RTFL. PERFORMED MAINT TIP 32-022. FOUND IN NEED OF LUBE IAW THIS MAINT TIP. ACP'D PRECAUTIONARY BITE CK OF LGCIU 1&2, NO FAULTS FOUND.SDR UALA2010012700327Shear Tie · crackedFRAME 74 STRINGER 32L & 33L CHECKED AND DAMAGED. FRAME 74, STRINGER 32L AND 33L SHEAR TIE IS CRACKED AND DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED TIE.SDR UALA2010012700328Shear Tie · crackedFRAME 74 STRINGER 31L & 32L CRACKED AND DAMAGED. FRAME 74 STRINGER 31 LEFT AND 32 LEFT, SHEAR TIE CRACKED AND DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED TIE.SDR UALA2010012700329Shear Tie · crackedFRAME 73 STRINGER 31L & 32L SHEAR TIE DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED TIE.SDR UALA2010012500294Smoke Detector · false activationSMOKE LAV DET FAULT ECAM AND STATUS MSG. REPEAT GRIPE. REPLACED SMOKE DETECTOR IAW MM 26-17-15.SDR UALA2010012100258Pump · failedYELLOW SYS HYD LOSS, RTFL. REPLACED HP FILTER ELEMENT. NO EVIDENCE OF DEBRIS. TROUBLESHOT OVERHEAT PROBLEM AND FOUND BAD CHECK VALVE 3083G. REMOVED DEFECTIVE CHECK VALVE. REPLACED AND PERFORMED HIGH POWER RUN FOR 25 MINS. REPLACED TEMP TRANSMITTER 3381GRSDR UALA2010012000249Skin · dentedEXTERNAL FUSELAGE SKIN IS DENTED FRAME 20 PLUS 6", 18" ABOVE CABIN FLOOR, JUST AFT OF DOOR 1R. TEMPORARY REPAIR ACCOMPLISHED PER SRM. PERMANENT REPAIR MUST BE ACCOMPLISHED WITHIN 3000 FLIGHT CYCLES. DAMAGE REMOVED, AREA IS FREE OF CRACKS AND TEMP REPAIR ACCOMSDR UALA2010011800221Slide · faultyDURING THE EMERGENCY LIGHTS TEST THE EPSU EXT LOAD FWD L" FAULT IS DISPLAYED ON CIDS AFTER EMER LIGHT SYS TEST. ACCOMPLISH TROUBLESHOOTING. TEST PASSED WHEN ELECTRICAL CONNECTOR PIN IS JUMPED. NEED NEW SLIDES. BOTH SLIDE PACKS NEED REPLACEMENT. REPLACED 1LSDR UALA2010011800204Slide · faultyDOOR 1R SLIDE FAILED TO DEPLOY. SLIDE STILL IN PLACE ON ACFT WITH DOOR CLOSED AND UNARMED. UNABLE TO RECORD MR NR AND DASH DUE TO POSITION OF SLIDE. REPLACED SLIDE PACK.SDR UALA2010011100146Actuator · faultyRT MLG FAILED TO EXTEND. RAT DEPLOYED. VALVE FOUND FAULTY. REPLACED CUTOUT VALVE L-G FREE FALL 2515GM. OPS NORMAL.SDR UALA2010011100118Coffeemaker · malfunctionedSTRONG PLASTIC BURNING ODOR COMING FROM AFT GALLEY VENT ABOVE COFFEEMAKER. SMELL IS NOT DEICE. FOUND MALFUNCTION COFFEEMAKER. REPLACED BOTH AFT COFFEEMAKERS M41 AND M42.SDR UALA2010010400051Fan · failedCONTINUED LOUD HUMMING NOISE IN COCKPIT WITH SUBSEQUENT ELECTRICAL ODOR. AVIONICS EXTRACT FAN FAULT DISPLAYED, NOISE STOPPED. REPLACED AVIONICS EXTRACT FAN. AEVC OPS CHECK NORMAL. NO FAULTS NOTED, ALL ECAM CLEAR. SMOKE ODOR HAS DISSIPATED.SDR UALA2010010500061Warning Light · illuminatedAFT CARGO PIT FIRE EXTINGUISHER AGENT WAS DISCHARGED DUE TO SMOKE WARNING IN COCKPIT. REPLACED CARGO FIRE EXTINGUISHER BOTTLE, OP CKD AND TEST OK.SDR UALA2009122904052Bulb · burned outESCAPE PATH LIGHT BURNED OUT AT ROW 18. REPLACED BULBSSDR UALA2009122804023Receptacle · faultyVERY STRONG ODOR OF BURNING ELECTRICAL ODOR IN CABIN OF ACFT. BOX ASSY FOUND DAMAGED DUE TO HEAT FROM ARCING FIRE OF EXTERNAL PWR PLUG. FIRE ODOR DIMINISHED SOURCE WAS GROUND PWR RECEPTICLE. BOX ASSY REQUIRES REPLACEMENT. STARTED TO REMOVE BOX ASSY. ALL ELESDR UALA2009122804010Unknown · odorELECTRIC BURNING ODOR IN AFT GALLEY DURING FINAL APPROACH. GONE BY THE TIME WE PARKED. CHECKED CIDS, AND SMOKE DETECTION SYS: NO FAULTS. VISUALLY CHECKED BOTH AFT LAVS, CEILING LIGHTS, GALLEY EQUIPMENT, WASTE BINS, AND AFT VENT FANS: NO SMOKE ODOR DETECTED. ASDR UALA2009122103940Cover · missingL SIDE FWD OF EMER EXIT BELOW EXIT SIGN IS MISSING A LENS AND BULB. REPLACED LENS COVER.SDR UALA2009122103953Panel · out of adjustLT OVERWING DOOR ILLUM, RTFL. ADJUSTED LT WING EXIT DOOR PANEL. VERIFIED WITH PANEL OFF SLIDE ARMED LIGHT WORKED OK. REINSTALLED PANEL ALL INDICATIONS NORMAL AT DOOR AND IN COCKPIT.SDR UALA2009121803927Pump · leakingSTRONG "DIESEL" FUEL ODOR. FLT DIVERTED. FOUND RT WING INBD FWD BOOST PUMP CAN FASTENERS ON WING BOTTOM SEEPING. REMOVED FASTENERS CLEANED RESIDUAL FUEL. NO LEAKS NOTED. REINSTALLED FASTENERS. FOUND BOTH CTR BOOST PUMPS INOP IN MANUAL MODE. REPLACED LT ASDR UALA2009121703907Battery · failedWHILE ACCOMPLISHING EMERGENCY LIGHT TEST GOT FAULT MESSAGE EPSU UNIT EMER R ATA 33-51-38. RIGHT EPSU SHOWED UNIT FAILURE LED. REPLACED EPSU, NO HELP. REPLACED BATTERY, EMER LIGHT TEST NORMAL.SDR UALA2009121503868Proximity Switch · faultyDOOR 1L SLIDE ARM LIGHT INTERMITTENT. ACFT WAS ON GROUND AND CABIN WAS UNPRESSURIZED WHEN DEFECT WAS NOTED. REPLACED DOOR 1L PROX SW 13WV1. ALL CHKS NORMAL.SDR UALA2009121403860Entertain Sys · odorELECTRICAL SMOKE ODOR DETECTED BY CREW. LT CABIN SIDE ENTERTAINMENT SYS WENT INOPERATIVE. FOUND SEB BOX AT ROW 18 LT SIDE TO BE CAUSE OF ELECTRICAL ODOR. REPLACED SEB, POWERED UP ENTERTAINMENT SYS. NO FURTHER ODORS NOTED.SDR UALA2009121103812Computer · faultyALT LAW ECAM, RTFL. REPLACED NR 1 ADIRU & ELAC 2. OPERATIONAL CHECKS OKAY.SDR UALA2009121403836Wire · miswiredCABIN O2 MASK DOOR AT FWD GALLEY AREA NEAR DOOR 1R FAILED TO DEPLOY DURING OPS CHECK. FOUND SWITCH WIRING WAS NOT WIRED CORRECTLY. W3523-1400R WAS RELOCATED FROM POSITION 2744VT-D TO 2744VE-F AND W3523-1401W FROM POSITION 2744VT-B TO 2744VT-H. OPS CHECKED GOOSDR UALA2009120703765Skin · dentedFOUND DENT JUST BELOW OUTFLOW VALVE PROTRUDING OUTWARD. REPAIRED DAMAGE IAW UA-EVA 73169.SDR UALA2009120803796Cover Plate · crackedSUSPECTED CRACK IN FWD CORNER OF UPPER COVER PLATE OF DOOR 2L. FOUND CRACKS IN BOTH UPPER CORNERS. HFEC PERFORMED TO VERIFY LENGTH OF CRACK. REMOVED UPPER COVER FROM DOOR 2L. FABRICATED REPAIR DOUBLERS IAW EVA. NEED TO BE COUNTERSUNK (EXCEPT FOR SCREW HOLESSDR UALA2009120703788Fmu · faultedENG1 FUEL CNTRL FAULT ENROUTE. REPLACED NR 1 ENG FMU. ACCOMPLISHED OPERATIONAL TEST AND IDLE LEAK CHECK. OPS NORMALSDR UALA2009120103710Epsu · dischargedESPU UNIT EMER R (12W) FAILED UNIT BITE TEST UNIT FAULT LIGHT ON. REPLACED EPSU. OPS NORMAL.SDR UALA2009120103711Wire · shortedEMERGENCY LIGHT TEST FAILURE. FOUND EPSU 13WL AT AFT CENTER GALLEY UNIT FAULT TEST LIGHT ON. REPLACED EPSU MR33131-317. REMOVED AND INSTALLED -409. ALSO REPLACED BATTERY. DOES NOT HELP. SWAP EPSU AND NOT HELP. RE-LOCATED UNITS TO ORIGINAL POSITION. REPSDR UALA2009113003695Battery · malfunctionedCHECK OF CABIN EMERGENCY LIGHTS YIELDS MSG 'EPSU BATTERY FWD L'. REPLACED FWD EPSU BATTERY.SDR UALA2009113003693Battery · no testCABIN EMERGENCY LIGHT BATTERY BITE TEST FAILED ON LT AISLE. SWAPPED BATTERY WITH ONE FROM SPARES. NO HELP. BATTERY AND NEW UNIT ON ORDER. REPLACED BATTERY ON LT OW DOOR. OPS CKD GOOD.SDR UALA2009112503663Skin · damagedSEVERAL AREAS OF DAMAGE NOTED DURING LIGHTNING STRIKE INSPECTION. DAMAGE IS LOCATED ON FWD FUSE LT SIDE BETWEEN FRAMES 1 AND 4 JUST BELOW AIRCRAFT CENTERLINE. FOUND NUMEROUS RIVETS BURNED AND 1 STRIKE IN OPEN BAY. REPAIRED LIGHTNING STRIKES IN RVSM AREA OF SDR UALA2009113003687Actuator · faultySEATS 10DEF FAIL OXYGEN MASK DROP TEST. PANEL DOES NOT OPEN. SEATS 10DEF ARE CONSIDERED INOP. REPLACED ACTUATOR ASSY PCN 649-2759, OPS CHECK PER AMM35-23-00-501, OPS GOOD.SDR UALA2009112403658Control Unit · faultedN/G VIBRATION, RTFL. TROUBLESHOOTING, FOUND THE NR 1 LGCIU WITHIN AIR FAULTS. REPLACED THE NR 1 LGCIU, SYS CHECKED OKAY. ALSO REPLACED LGCIU 2 IAW LM2905.SDR UALA2009112303632Lamp · inoperativeLT OVERWING EMERGENCY LIGHT INOP LT ASSY BULB BURN'T OUT INOP. RELAMP AND RE-INSTALL LENS, OPS CHECK GOOD.SDR UALA2009112003625Line · leakingYELLOW HYD LOW PRESS, FLIGHT DIVERTED. ON WALK AROUND FOUND HYD FLUID LEAKING FROM NR 2 ENG UPPER PYLON. FOUND 2 EA HYD LINES LEAKING INSIDE ACCESS PANEL 425BR. WRAPPED SAFETY WIRE TO SHOW LINES. REMOVED ENG PRECOOLER AND 2EA FIRE X BOTTLES AND CONTINUED RESDR UALA2009112003611Power Supply · faultyEPSU BATTERY AFT L MESSAGE. REPLACED AFT LEFT UNIT FOR UNIT FAULT. TESTS OKAY.SDR UALA2009111903606Slide · low pressureTHE 1R SLIDE NOT IN GREEN PRESSURE. REPLACED SLIDE, OPS CHECK OK.
Back to IAE V2522-A5