IAE V2522-A5
Service difficulty reports · 3,465
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009111803598Skin · crackedNR 2 ENG OUTBOARD REVERSER SLEEVE UPPER AFT SECTION HAS A CRACK IN SKIN. REMOVED OUTBOARD SLEEVE BLISTER FAIRING, CUTOUT DAMAGE, LAID OUT RIVET PATTERN FOR REPAIR DOUBLERS. NEED TO MANUFACTURE REPAIR DOUBLERS AND FILLERS FOR TWO AREAS OF DAMAGE AND REINSTALSDR UALA2009111003512Smoke Detector · inoperativeDOOR 2L AFT LAVATORY SMOKE DETECTION SYSTEM(S) INOPERATIVE. REPLACED SMOKE DETECTOR AT 2L AFT LAV, CFDS TEST CHECK GOOD.SDR UALA2009110903493Proximity Sensor · faultyLANDING GEAR WOULD NOT RETRACT, FLIGHT DIVERTED. REPLACED PROX SENSOR 23GA. BITE CHECK OK, ALSO REPLACED LGCIU2. BITE CHECK OKAY.SDR UALA2009110903483Battery · dischargedWHILE ACCOMPLISHING EMERGENCY LIGHTS CHECK DURING 3SVC GOT FAULT, EPSU BATTERY EMER R. REPLACED BATTERY RIGHT SIDE, TESTS OKAY.SDR UALA2009110403436Control Unit · malfunctionedLAV AND CRG DET FAULT DISPLAYED ON UPPER ECAM SCREEN - SMOKE. SUPPLEMENTAL DATA UPDATE, REPLACED SMOKE DETECTION CONTROL UNIT. OPS NORMAL.SDR UALA2009102603329Battery · failedEMERGENCY LIGHT TEST FAILS FOR L OVERWING BATTERY. REPLACED L OVERWING EPSU BATTERY, OP CHK'D OKAY.SDR UALA2009102203297Slat · damagedRIGHT L/E INBOARD, NEXT TO PYLON HAS BIRD STRIKE. DENT DAMAGE NOTED. MEASURED AT 5 INCHES BY 2.5 INCHES, 3-8 INCHES DEEP. REMOVED SLAT AND ROUTED TO SHOP. REPLACED NR 1 SLAT.SDR UALA2009101903255Battery · no testEPSU BATTERY EMERGENCY RIGHT MSG DISPLAYED DURING EMERGENCY LIGHT TEST. REPLACED BATTERY ASSY, CHECKED OKAY.SDR UALA2009101603242Slide · faultyEMERGENCY LIGHTS TEST FAIL WITH EPSU EXT LOAD FWD L. REMOVED AND REPLACED EPSU AND PWR SUPPLY, NO HELP. REMOVED AND REPLACED DOOR 1L EVAC SLIDE, OPS CHECK GOOD.SDR UALA2009101403229Oxygen Mask · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). REPLACED OXYGEN MASK, OP CHECKS GOOD.SDR UALA2009100503111Unknown · odorELECTRICAL BURNING SMELL IN BACK OF A-C. UNABLE TO DETECT ANY ELECTRICAL SMELL IN AFT GALLEY AS PER FLT ATTENDANT. CHECKED ALL AFT GALLEY C-B'S, NONE TRIPPED. CYCLED ALL GALLEY LIGHTS, ALL NORMAL. SUSPECT SMELL WAS PICKED UP THRU AIR COND FROM EXTERIOR THESDR UALA2009100503124Computer · malfunctionedAIRCRAFT PITCH UP OCCURRED WITHOUT STABILIZER TRIMMING OCCURRING. REPLACED ELAC 1 AND 2. ACCOMPLISHED CAT III AND OP TEST ALL OK.SDR UALA2009092903063Shutoff Valve · malfunctionedBLEED PROBLEMS, RTFL. REPLACED NR 2 ENG PRSOV (400 1HA) AND BLEED PRESS REG SOLENOID (10HA). REPLACED NR 1 ENG BLEED PRESS REG SOLENOID. RAN ENGS TO PWR, BLEED SYS OPS CHECKS NORMAL. ACP'D ENG POWER RUNS ON BOTH ENG'S BLEED PARAMETERS WITHIN LIMITS. ACP'DSDR UALA2009092803036Epsu · faultyCABIN OVERWING EMERGENCY EXIT SIGN AND ESCAPE PATH LIGHTING POWER SUPPLY 12WL HAS A FAULT LIGHT. REPLACED EPSU RWL. OP CHECKED ITEMS 3 & 5 PER MMS.SDR UALA2009092503030Filter Element · faultyGREEN/BLUE HYD OVHT MSG, RTFL. ACP WALK AROUND, FOUND NO SIGNS OF HYDRAULIC OR OIL LEAKS. HYDRAULIC AND OIL QTY INDICATIONS ON ECAM CHECK NORMAL. FAULTS CLEARED. NO ECAM, STATUS OR MAINT MSGS DISPLAYED. RAN HYD SYS FOR 1 HR & CYC FLIGHT CONTROLS, NO MSGS.SDR UALA2009092303009Slide · reads lowDOOR 2L SLIDE PRESSURE GAUGE READS BLOW GREEN BAND. REPLACED SLIDE.SDR UALA2009092102978Loop · inoperativeAIR BLEED MESSAGE. SENSING ELEMENT IN LT AC BAY PREVIOUSLY REPOSITIONED. IAW TSM FOUND HIGH RESISTANCE BETWEEN PIN A-4D AND PIN A-5D OF THE BMC 2. RESISTANCE CHECKS GOOD BETWEEN PIN A-4D OF BMC TO CABLE 77HF. CONTINUED INSTALLATION OF SENSING ELEMENT THRU ENDSDR UALA2009092102962Power Supply · shortedDURING CABIN EMERGENCY LIGHTS CHECK, SYSTEM TEST FAILED WITH MESSAGE 'EPSU UNIT FWD L'. REPLACED FWD EPSU, NO HELP. FOUND SHORT FOR FLOOR LIGHTS AT SEAT 6 WHICH WAS TAKING OUT THE EPSU AT DOOR 1L. REPAIRED SHORT, GROUND CHECKED OKAY.SDR UALA2009092102980Wire Harness · damagedEMERGENCY LIGHTS OUT AT SEATS 15 & 16. FOUND SIDE WALL CONNECTOR APART AND WIRE PULLED OUT. REPLACED WALL TO SEAT HARNESS, OPS CHECK NORMAL. NO DEFECTS NOTED.SDR UALA2009092202987Power Supply · faultyEMERGENCY FLOOR LIGHTS INOP AT SEATS 1, 2, 8, 9 & 10. SEAT 10 WAS INOP; REPAIRED CONNECTOR. NOW 10 WORKS OK. REF WDM 33- 51-06 POST SB 33-1041 WIRE MOD TO EMERG LIGHT CIRCUITS, WORKING WITH SAMC TO FIND BASE COA FOR PWR TO THESE SEATS OR LOCATION OF BATTERYSDR UALA2009091602932Blade · damagedNR 1 ENG BIRD STRIKE, RTFL. ON CLIMBOUT, ABOUT 800FT, CREW HEARD A LOUD BANG FOLLOWED BY A BAD ODOR AND MILD ACFT VIBRATION. ACFT HAD A BIRD STRIKE ON THE LT SIDE NR 1 ENGINE. ALL INDICATIONS WERE NORMAL. NO CABIN PREP AND CREW MADE A NORMAL LANDING. NR 1 ESDR UALA2009091002854Oxygen System · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. PRESSURE RECORDED AT 1500 PSI, FILLED TO 2000 PSI.SDR UALA2009090402783Battery · failedCABIN EMERGENCY LIGHTS FAIL 3 SVC CHECK FOR AFT LEFT BATTERY. REPLACED AFT LEFT EMERGENCY LIGHT BATTERY, OP CHECKED OKAY.SDR UALA2009090402779Oxygen System · defectiveCREW 02 CHECK. DUE TO REPETITIVE CREW 02 SERVICING WITH NO LEAKS ISOLATED ACCOMPLISH LEAK CHECK OF CREW 02 SYSTEM. REPLACED F/O 02 MASK BOX. FOUND TEST AND RESET SWITCH STUCK AND NOT WORKING. ALSO LEAKED CHECK LINES BELOW PILOT AND F/O 02 BOXES. NO LEAKS SDR UALA2009090202754Power Supply · faultyCLICKING NOISE AT 11E. REPLACED EMERGENCY LIGHT POWER SUPPLY, TESTS OKAY.SDR UALA2009090202752Battery Pack · failedCABIN EMERGENCY LIGHT FAILED TEST. EPSU EMERGENCY BATTERY R ON PTP PANEL. REPLACED BATTERY PACK.SDR UALA2009082802692Bottle · low pressureMED 1R, DOOR ASSIST BOTTLE PRESSURE BELOW LIMITS. SERVICED AS REQUIRED.SDR UALA2009082502651Switch · malfunctionedELECTRICAL PROBLEM, RTFL. REPLACED STROBE SWITCH, TESTS OKAY.SDR UALA2009082602668Microphone · inoperativeCAPTAIN'S O2 MIC INOPERATIVE. REPLACED CAPTAIN'S OXYGEN MASK. OPS CHECKS NORMAL.SDR UALA2009082002554Unknown · odorF/A SMELLED ELECTRICAL ODOR ON DESCENT INTO PIT IN AFT GALLEY. NO SMOKE REPORTED. INSPECTED AFT GALLEY, LAVS, CARGO COMPARTMENT & GALLEY EQUIPMENT NO DEFECTS NOTED. NOTICED IN AFT GALLEY COMPARTMENT UNDERNEATH COFFEEMAKERS, SEVERAL NAPKINS LAYING NEXT TO HOSDR UALA2009081702505Bottle · low pressureDOOR 1L ASSIST BOTTLE LOW PRESSURE. REPLACED DIAPHRAGM AND O-RINGS PRESSURE GOOD.SDR UALA2009081702504Slide · faultyEPSU EXT LOAD FWD LT FAULT ON EMERGENCY LIGHTS TEST. T/S FOUND DOOR NR 1 LEFT SLIDE BAD. REPLACED L1 DOOR SLIDE.SDR UALA2009080702402Wire · shortedNR 1 ENGINE FIRE BOTTLE NR 1 TRIPS C/B DURING TEST. FOUND CONVOLUTED CONDUIT WORN THRU FROM METAL SUPPORT CLAMPS & WIRE NR 2621-0020 DAMAGED & SHORTED. REMOVED & REPLACED WIRE NR 2621-0020. ACP SQUIB FIRING CIRCUIT TEST. CHECKS GOOD.SDR UALA2009081002423Lamp · inoperativeNR 1 ENGINE, FIRE BOTTLE NR 1 TRIPS C/B DURING TEST. RELAMPED, OP CHECK OKAY.SDR UALA2009080602370Warning System · activatedCREW REPORTS AEVC FAULT. RTFL. RESET VENT EXTRACT FAULT AND ACCOMPLISHED SYS REPORT TEST, ALL FAULTS CLEARED. NO RECURRENCES. NO ACTION NECESSARY.SDR UALA2009080302318Sill · obstructedF/A REPORTS DOOR 2R DIFFICULT TO ARM. A CAP FROM A WATER BOTTLE WAS IN THE DOOR SILL. REMOVED, ARMED AND DISARMED DOOR WITH NO PROBLEMS. ALSO, HAD OUTBOUND F/A'S ARM AND DISARM DOOR. REPORTED NORMAL ACTION OF THE ARMING LEVER.SDR UALA2009072402200Frame · crackedRAMP REPORTS LEFT OVERWING SLIDE PACK FRAME CRACKED, DURING WALK AROUND AT DEPARTURE. REPLACED LEFT OVERWING SLIDE ASSY, ALL LOCK PINS REMOVED.SDR UALA2009072402205Slide · unserviceableREPLACE NR 1 RT DOOR SLIDE ACCT CONNECTOR LACING CORD IS UNSERVICEABLE. REMOVED & REPLACED NR 1 RT DOOR SLIDE.SDR UALA2009072002130Slide · low pressureNR 1 RT SLIDE BOTTLE PRESSURE IS IN THE RED BAND. REPLACED SLIDE. ACP RII, NO DEFECTS NOTED.SDR UALA2009071702114Structure · damagedNR 1 PYLON HAS SUSTAINED DAMAGE. APPLYING UA-EVA 72783B TIME LIMITED REPAIR. RECEIVED LAST FASTENERS FOR THE DOUBLER REPAIR, INSTALLED & SOLD.SDR UALA2009072002117Hinge Fitting · migratedL1 DOOR UPPER HINGE MIGRATED OUT OF FITTING. REMOVED AND REPLACED L1 DOOR AND REPLACED HINGE FITTINGS. ADJUSTED DOOR AFTER INSTALLATION AND INSPECTED.SDR UALA2009071602102Shutoff Valve · failedPACK 1 AND 2 FAULTS, RTFL. REPLACED HPV DUE TO LEAK AND REPAIRED LEAK OF CLOSURE SOLENOID LINE. NEW NR 2 ENG HPSOV WILL NOT CLOSE COMPLETELY. BUTTERFLY VALVE BINDS SO ECAM BLEED SHOWS OPEN POSITION ALL THE TIME. REPLACED VALVE AND FLEXIBLE HOSE. ENG 2 RUNSDR UALA2009071702107Structure · dentedRT SIDE LWR FUSELAGE HAS SMALL DENT FWD OF FR15, BELOW AND AFT OF RT FWD AVIONICS DOOR. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR UALA2009071302029Slide · faultyEMERGENCY LIGHT FAILED TEST, FWD ATT DISPLAY PANEL SHOWED EPSU EXT LOAD FWD L. T/S SYSTEM FOUND DOOR 1R SLIDE BAD. REPLACED 1 RT SLIDE ASSY. ACP'D INSP OF DOOR 1R SLIDE INSTALLATION. WITNESSED CIDS TEST.SDR UALA2009071302035Smoke Detector · faultySMOKE LAVATORY DET FAULT ECAM. REPLACED AFT LAV SMOKE DETECTOR F, FAULT CLEARS AND SYSTEM CHECKS GOOD.SDR UALA2009070801971Line · leakingGREEN HYD LO LEVEL ON ECAM QTY ZERO ON HYD PAGE. FOUND 1\ GRN SYS HYD PRESS LINE IN NR 1 PYLON CHAFED THROUGH AT CLAMPING LOCATION.SDR UALA2009070601927Slide · faultyEPSU EXT LOAD FWD L DISPLAYED AFTER 3 SVC EMERGENCY LIGHT TEST. FOUND NR 1 RT DOOR SLIDE FAULTING. NEEDS TO BE REPLACED.SDR UALA2009070601944Tape · looseAIRFRAME VIBRATION. RTFL. AT FL 240 AND 320 KTS FELT VIBRATION IN FLOOR & THRU RUDDER PEDALS, FLT ATTENDANTS ALSO FELT VIBRATION. SLOWED TO 270KTS & VIB STARTED TO DIMINISH & AT AROUND 250 KTS VIBRATION CEASED, NO FURTHER PROBLEMS DURING DESCENT. FOUND TAPSDR UALA2009062901847Cover · brokenSLIDE 2L COVER BROKEN OFF AT HINGES. SECURED SLIDE COVER AT DOOR 2L.SDR UALA2009062601804Cover · damagedNOTICED EEL SEAT LIGHT WIRING AT SEAT ROW 20ABC LOOSE AND NICKED. WIRING WAS NOT INSTALLED IN ANY TYPE OF RUN OF CONDUIT. REPAIRED DAMAGED WIRING COVER & SECURED.
Back to IAE V2522-A5