IAE V2522-A5
Service difficulty reports · 3,465
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01399Unknown · malfunctionedRETURN TO FIELD DUE TO INABILITY TO RETRACT LANDING GEAR. STILL WORKING.SDR UALA2008111301399Seal · defectiveRETURN TO FIELD DUE TO INABILITY TO RETRACT LANDING GEAR. STILL WORKING. REPLACED STRUT SEALS ON ALL 3 GEAR. RT MLG & NLG INSTALLED. MLG SERVICED ACP NLG STRUT SVC. HOOK UPS COMPLETE. JACKED AND SWUNG GEAR. ALSO ACCOMPLISHED FREE FALL TEST. ALL CHECKEDSDR 2008UALA01421Microphone · shortedCREW REPORT: F/O O2 MASK IS INTERMITTENT. NO SOUND THROUGH SPEAKER. INTERMITTENT SHORT IN MIC. REPLACED MASK ASSY.SDR 2008UALA01422Oxygen Mask · inoperativeF/O O2 MASK INOP. REPLACED F/O O2 MASK.SDR 2008UALA01284Solenoid Valve · faultyCREW O2 SYSTEM, OP CHECK OF LP SOLENOID FAILED. LP VALVE FAULTY. REPLACED LP SOLENOID VLV. OPS CHECKED OK.SDR 2008UALA01301Fire Bottle · blownNR 1 ENG NR 1 BOTTLE INADVERTENTLY BLOWN DURING HMV VISIT. ACCIDENTAL DEPLOYMENT OF FIRE BOTTLE. REPLACED BOTTLE AND CLEANED AREA.SDR 2008UALA01260Shear Plate · damagedFOUND SHEAR PLATE DAMAGED BEYOND LIMITS. ACCOMPLISHED MAJOR REPAIR AT DEN.SDR 2008UALA01215Sill · corrodedDOOR SILL CASTING 2R CORRODED ON FWD SECTION BEYOND REPAIR. ACCOMPLISHED MAJOR REPAIR AT DEN.SDR 2008UALA01203Girt Bar · dirtyDOOR 1R AFT GIRT BAR FITTING STOP LEVER MECHANISM STUCK IN DOWN POSITION. FOUND DIRTY FITTING. CLEANED AND LUBED FITTING. OPS CHECKED NORMAL.SDR 2008UALA01204Battery · failedBATTERY FAULT LIGHT ILLUMINATED ON AFT CABIN EMERGENCY LIGHT POWER SUPPLY UNIT. FOUND THE BATTERY FAILED. REPLACED BATTERY.SDR 2008UALA01205Power Supply · no testRT OVERWING EXIT EMERGENCY LIGHT POWER SUPPLY UNIT WILL NOT TEST. REPLACED POWER SUPPLY UNIT.SDR 2008UALA01116Transducer · faultyDIVERTED DUE TO LEFT ENGINE VIBRATION. REPLACED EVM (TRANSDUCER). ENGINE RUNS WERE NORMAL AFTERWARD.SDR 2008UALA01185Light · faultyEPSU EXT LOAD EMER R. FOUND INTERNAL SHORT WITHIIN SLIDE PACK. REPLACE RT OVERWING SLIDE AND PSU 12WL.SDR 2008UALA01115Outflow Valve · malfunctionedRTFL WITH A CABIN PRESSURE ISSUE. VALVE 22HQ IN OFF POSITION CAUSING SKIN FAULT ECAM. TURNED ON VALVE 22HQ AND REPLACED THE AVEC AS PRECAUTIONARY. BITE TEST WAS GOOD.SDR 2008UALA01114Circuit Card · failedRTFL WITH AN ENGINE FIRE WARNING INDICATION. INTERFACE CIRCUIT BOARD FAILED (5LP). AFTER TROUBLESHOOTING, REPLACED THE 5LP INTERFACE BOARD AND ALSO FOUND LOOSE CONNECTION AT FIREX BOTTLE. REPLACED FIREX BOTTLE.SDR 2008UALA01079Diaphragm · leakingR2 DOOR ASSIST BOTTLE NOT HOLDING PRESSURE. FOUND ASSIST BOTTLE DIAPHRAGM LEAKING. REPLACED ASSIST BOTTLE DIAPHRAGM. LEAK CHECKED OK.SDR 2008UALA01059Light · burned outEMERGENCY PATH LIGHTING AT SEAT 20ABC BULB BURNT OUT. REPLACED LIGHT ASSEMBLY.SDR 2008UALA01112Lanyard · disconnectedLT OFFWING EVAC SLIDE INFLATION CYLINDER WIRE CONTROL ASSY WAS NOT ENGAGED WITH FLEX CONTROL ASSY PER AMM 25-62-46-400-001 AND AIRBUS DIAGRAM D4-0140 PAGE 2. BOTTLE IS LOCATED IN AFT PIT. RE-CONNECTED WIRE CONTROL ASSY CORRECTLY.SDR 2008UALA01145Slide · misinstalledTHE BLOW OUT DOOR LOCKING PIN WAS NOT COMPLETELY LATCHED. SLIDE WAS PACKED TOO HIGH. REBAND AND OVEN BAKE 12 HOURS.SDR 2008UALA01034Smoke Warning · malfunctionedCARGO SMOKE TEST FAILS. CYCLE SYSTEM CB'S - ALL TESTED NORMAL AFTER.SDR 2008UALA00988Floorboard · damagedCARGO FLOORBOARD RPL S GLS PNL. MAJOR REPAIR ACCOMPLISHED AT LCQ (COA ACCOMPLISHED).SDR 2008UALA00956Fire Loop · out of positionFIRE LOOP A FAULT DISPLAYED ON UPPER ECAM SCREEN ENG 2. FOUND LOOP TOUCHING METAL FRAME IN ENGINE. REPOSITIONED LOOP TO CORRECT POSITION, OPS TESTED NORMAL.SDR 2008UALA00957Light · malfunctionedEMERGENCY EXIT LIGHTS ARE ON. RESET CIDS AND NORMAL OPS RETURNED.SDR 2008UALA00953Handle · obstructedRIGHT AFT SLIDE INDICATION INOP ON DOOR-OXY SYSTEM ECAM PAGE - DOOR-OXY CREW COMMENTS: UNABLE TO ARM SLIDE FOR DOOR 2R. FOUND RUBBER TRIM AROUND DOOR ARM HANDLE NOT SECURE. REPOSITIONED AND SECURED TRIM, DOOR ARMS AND DISARMS NORMALLY.SDR 2008UALA00866Lanyard · out of positionLANYARD HANGING OUT OF SLIDE PACK AT 1L. REPACKED LANYARD AND SLIDE ARMS/DISARMS NORMALLY.SDR 2008UALA00858Lamp · inoperative2R AISLE EMERGENCY LIGHT INOP. LAMP IS OUT IN ASSY. RELAMPED DOOR 2R, ALL OPS CHECKS ARE GOOD.SDR 2008UALA00857Sill · corrodedDOOR 2R DOOR SILL FWD SIDE HAS CORROSION IN AREA OF PREVIOUS REPAIR. REPLACED DOOR SILL ASSY.SDR 2008UALA00859Slide · faultyLT OFFWING SLIDE HAS DELAMINATION FOUR INCHES LONG AT AFT EDGE IN AREA. REPLACED LT OVERWING SLIDESDR 2008UALA00919Beam · damagedFOUND BEAM NR 150 DAMAGED BEYOND REPAIR. ACCOMPLISHED MAJOR REPAIR AT DEN.SDR 2008UALA00830Floorboard · corrodedA-PIT FLOORBOARD AND SKID PLATES FOUND WITH SEVERAL AREAS ON THE FLOOR SUPPORT WITH CORRISION. ACCOMPLISHED MAJOR REPAIR AT ORD.SDR 2008UALA00845Squib · no testAFT SQUIB LIGHT WILL NOT TEST DISCHARGE. RERACKED SDCU AND TEST OPERATED NORMALLY.SDR 2008UALA00810Bottle · reads lowFA SIDS PANEL AT 1L CAUTION ILLUMINATED. CANT RESET. FOUND LT OVERWING BOTTLE PRESSURE LOW. UNKNOWN LEAK AT BOTTLE. REPLACED THE OVERWING SLIDE BOTTLE, PRESSURE CHECK OK AND LIGHT WENT OUT.SDR 2008UALA00786Girt Bar · obstructedDOOR 2R DOES NOT REMAIN ARMED AFTER INITIAL ARMING OF DOOR MUST REARM SEVERAL TIME. DEBRIS UNDER GIRT BAR FITTING. REMOVED AND CLEANED DEBRIS FROM AREA AROUND FLOOR FITTINGS. DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA00716Oxygen System · low pressureOXYGEN NEEDS TO BE SERVICED. SERVICED O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA00679Lens · missingEEL RED LENS MISSING AT FORWARD CLOSET. REPLACED EEL LENS COVER.SDR 2008UALA00718Microphone · shortedF/O'S OXYGEN MASK MICROPHONE IS INOPERATIVE. SHORT IN MIC WIRING IN MASK (F/O). REPLACED F/O O2 MASK ASSY. ALL OPS CHECKS WERE GOOD.SDR 2008UALA00709Coffeemaker · faultyELECTRICAL SMELL EMANATING FROM THE AFT GALLEY. UNKNOWN (POSSIBLE SHORT WITHIN COFFEE MAKER). REPLACED COFFEEMAKER AND OPS CHECKED OK, NO SMELL, NO REPEATS.SDR 2008UALA00661Lens · brokenDOOR 2 LEFT EXIT LT BROKEN. REPLACED LENS COVER.SDR 2008UALA00642Wire · damagedNR 1 ENGINE, NR 1 SQUIB DOES NOT TEST. FIRE PNL NO HELP. BROKEN WIRES AT SQUIB. REPLACED TWO WIRES AT SQUIB LOCATION, SYSTEM TESTS NORMALLY.SDR 2008UALA00591Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO 1740, HELD PRESSURE FOR 3 HOURS- NO LEAKS NOTED.SDR 2008UALA00604Lever · faultyLDG GEAR DOORS SEQUENCED IMPROPERLY WHEN GEAR HANDLE RAISED. RED GEAR UNLK LTS EXTINGUISHED. INDICATIONS CYCLING OUT OF SEQUENCE AFTER HANDLE RAISED. ALL IND NORMAL AT THIS TIME, HOWEVER THERE IS A SLIGHT VIBRATION NOTED ON THE FLT DECK FLOOR. COULD NOT DUPLSDR 2008UALA00485Oil System · leakingCREW COMMENTS: OIL SMELL IN CABIN, WORSE ONCE AIRBORNE. OIL LEAKAGE DUE TO BEARING FAILURE. SMELL WAS NEVER TRACED TO A PARTICULAR COMPONENT, HOWEVER THE NR 1 ENG WAS REPLACED DUE TO AN OIL LEAK AROUND 4TH STAGE IGV AT 6 O'CLOCK POS AND LEASE RETURN AGREEMESDR 2008UALA00481Battery · faultyEPSU BATTERY FWD L DISPLAYED ON EMERGENCY LIGHT TEST. REPLACED BATTERY.SDR 2008UALA00439Power Supply · faultyAFTER REPLACEMENT OF DOOR 2R SLIDE, ACFT FAILS THE EMERGENCY SYSTEM TEST WITH ERROR (EPSU UNIT EMER LT, 33-51-38). FOUND EPSU FAILED. REPLACED EPSU (LT) OPS CHECK NORMAL.SDR 2008UALA00440Power Supply · faultyCABIN EMERGENCY LIGHT TEST ITEM NR 2 ON 3SVC CK SHOWS RT EMERGENCY EPSU ON DISPLAY. REPLACED POWER SUPPLY.SDR 2008UALA00438Fitting · out of adjustTRYING TO INSTALL NEW SLIDE DOOR 2R. GIRT BAR WILL NOT ALIGN WITH PINS. SUSPECT GIRT GAR FITTINGS OR EMERGENCY CONTROL HANDLE OUT OF RIG. *S/D* GIRT BAR FITTING OUT OF ADJUSTMENT. ADJUSTED GIRT BAR FITTING, SYSTEM OPS CHECKED NORMALLY.SDR 2008UALA00441Skin · damagedLEFT ELEVATOR LOWER SKIN DENT REPAIR LOCATED 6 INCHES OUTBOARD OF ER5 AND 4 INCH AFT OF FWD SPAR REQUIRES VISUAL INSPECTION OF TAPE SECURITY AND TAP TEST OF AREA BEYOND THE 6 X 6 REPAIR AREA. TEMP REPAIR REMOVED AND PERMANENT REPAIR INSTALLED AS A MAJOR REPAISDR 2008UALA00436Slide · faultyDOOR 1L SLIDE SHOWING INTERNAL CIDS FAULT. FOUND INTERNAL ELECTRICAL FAULT IN SLIDE 1L. REPLACED SLIDE ASSY, NO REPEATS.SDR 2008UALA00389Drain Mast · shortedAFTER T/O CABIN CREW IN AFT GALLEY SMELLED ELEC BURN SMELL. AFT GALLEY ODOR DISSIPATED IN A COUPLE MINUTES. NOTICED AFT GALLEY DRAIN C/B POPPED OVERHEAD PNL. GALLEY DRAIN MAST SHORTED. REPLACED GALLEY DRAIN MAST, OPS CHECKED NORMAL.SDR 2008UALA00349Oxygen System · leakingOXY REGUL LO PR 20 PSI. FOUND CAPT O2 BOX VALVE LEAKING. REPLACED CAPT O2 BOX AND MASK. SERVICED CREW O2 TO 1610 PSI. NO LEAKS NOTED.
Back to IAE V2522-A5