SDR 2008UALA00369Oxygen Mask · leakingCAPTAIN'S O2 MASK LEAKING DURING TEST. UNKNOWN O2 LEAK. REPLACED CAPT O2 MASK. OPS CHECKED OK.SDR 2008UALA00370Oxygen Mask · leakingWHEN TESTING OBSERVERS O2 MASK, MASK DID NOT RESEAT AND CONTINUED TO PURGE O2. OBSERVER`S MASK LEAKING. REPLACED OBSERVERS MASK ASSY AND LEAK CHECKED. NO LEAKS NOTED.SDR 2008UALA00315Proximity Switch · failedRTFL WITH A CARGO DOOR INDICATION PROBLEM. PROX SWITCH 30WV FAILED CAUSING FWD CARGO DOOR ECAM MESSAGE. REPLACED/ADJUSTED PROX SWITCH 30 WV. OPS CHECKED OK.SDR 2008UALA00385Proximity Sensor · faultyRTFL DUE TO FWD CARGO DOOR OPEN INDICATION. PROX SNSR 30WV TGT POS ECAM. PROX SENSOR FAILURE. REPLACED PROX SENSOR 30 WV. OPS CHECKED NORMAL. NO REPEATS.SDR 2008UALA00304Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM ITEMS NR 145, 140 AND 90. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00305Web · corrodedAFT RIGHT CORNER FLOOR WEB BETWEEN FR 69 AND FR 70 IS CORRODED. MAJOR REPAIR ACCOMPLISHED.SDR 2008UALA00303Control Unit · failedFLIGHT DIVERTED UNDER AMBER ALERT DUE TO A FUEL IMBALANCE. FLSCU FAILURE. REPLACED NR 1 FLSCU, OPS CHECKED NORMALLY.SDR 2008UALA00309Harness · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). BROKEN HARNESS (LEAKING). REPLACED F/O'S O2 HARNESS.SDR 2008UALA00246Seal · leakingRTFL UNDER AMBER ALERT DUE TO A LANDING GEAR RETRACTION MESSAGE. LEAKING STRUT SHOCK SEALS. REMOVED AND REPLACED SEALS ON NLG SHOCK STRUT SERVICED STRUT AND PERFORMED RETRACTION TEST, ALL NORMAL OPERATION.SDR 2008UALA00285Connector · looseEEL LIGHT AT 7C INOP. LOOSE CONNECTOR AT SEAT ROW 7. RESECURED LOOSE CONNECTOR, LIGHTS OPS NORMAL.SDR 2008UALA00250Floorbeam · corrodedFOUND CORROSION BEYOND SRM LIMITS ON FLOORBEAM ITEMS 105, 170 & 175. MAJOR REPAIR ACCOMPLISHED AT DEN.SDR 2008UALA00204Sill · corrodedSILL AT DOOR 2R CORRODED AROUND GIRT BAR FITTINGS. ACCOMPLISHED MAJOR REPAIR AT DEN.SDR 2008UALA00223Ballast · faultyAFT GALLEY ELECTRICAL SMELL REPORTED BY F/A. FAULTY BALLAST FOR AFT GALLEY WORK LIGHT. REPLACED AFT GALLEY WORK LIGHT BALLAST INSIDE PANEL G3.SDR 2008UALA00161Seal · failedSTRONG OIL SMELL NOT ELECTICAL SMELL IN CABIN. RAN ENGINE TO PWR, WITH ONE BLEED AND ONE PACK AT A TIME. BURN OIL SMELL IS STRONGER WITH LEFT ENGINE BLEED. FOUND OIL IN EXTENSION SHAFT (NR 1 ENG). CLEANED OIL AND PERFORMED A PACK BURN AND INSTALLED BLIND CSDR 2008UALA00162Battery · dischargedBOTH FWD EMERGENCY FLASHLIGHTS DEAD. REPLACED BOTH BATTERIES. OPS CHECKED NORMAL.SDR 2008UALA00163Proximity Sensor · intermittentTHREE RED WITH NO ECAM ON FINAL. GEAR NOT DOWN RECYCLE OK GEAR DOWN. PROX SENSOR INTERMITTENT (38GA). REPLACED PROX SENSOR 38GA, PERFORMED GEAR SWINGS, ALL NORMAL, NO REPEATS.SDR 2008UALA00147Computer · faultyFLIGHT DIVERTED DUE TO A FAULTING FMGC. FMGC FAILURE (SHOP FINDINGS NFF). REPLACED FMGC, OPS CHECKED NORMAL.SDR 2008UALA00153Epsu · faultyCIDS FAULTS, EPSU BATTERY EMER L, EPSU BATTERY, AFT L. EPSU FAILURE. REPLACED EPSU AT 11WL AND 13WL. ALL SYSTEMS TESTED NORMAL.SDR 2008UALA00154Bottle · low pressureDOOR 1 LEFT ACCUMULATOR BOTTLE PRESSURE LOW. SERVICED ACCUMULATOR TO FULL CHARGE.SDR 2008UALA00086Oxygen System · low pressureFLIGHT DIVERTED DUE TO FLIGHT DECK OXYGEN PRESSURE. SERVICED CREW O2 SYSTEM AND LEAKED CHECKED THE ENTIRE SYSTEM THOROUGHLY. COULD FIND NO SOURCE OF LEAK. SUSPECT A CREW O2 MASK TO BE UNSTOWED/IMPROPERLY STOWED.SDR 2008UALA00087Battery Pack · failedEMERGENCY LIGHT TEST FAULTED EPSU L AND R. DUAL BATTERY PACK FAILURE. REPLACED BOTH LEFT AND RIGHT EPSU'S. OPS CHECKED NORMAL.SDR 2008UALA00096Oxygen System · low pressureLEAK CHECK O2 SYSTEM. SERVICED CREW O2 SYSTEM AND PERFORMED LEAK CHECKS OF ALL LINES AND MASKS. NO LEAKS WERE NOTED.SDR 2008UALA00077Smoke Detector · malfunctionedCARGO SMOKE DETECTOR FAILS TO TEST. FAILS LOOP-A FWD PIT. ALSO HAD CIDS LAV SMOKE DET FAIL MSG. RESET C/B'S FOR SDCU (C6 AND T18) AND PERFORMED CARGO SMOKE DET TEST. ALL PASSED AND ALL MESSAGES CLEARED AFTER RESET. NO REPEATS SINCE ORIGINAL.SDR 2008UALA00095Stowage Box · damagedRIGHT AFT CREW OXYGEN MASK BOX DOES NOT TEST AND DOOR DOES NOT CLOSE PROPERLY. UNKNOWN DAMAGE TO STOWAGE BOX. REPLACED CREW O2 (RT AFT) STOWAGE BOX AND OPS CHECKED NORMAL.SDR 2008UALA00058Slide · delaminatedLEFT, OVERWING EXIT, SLIDE PACK, IS DELAMINATING IN TWO AREAS. DELAMINATION - REPLACED SLIDE ASSY.SDR 2008UALA0031Lamp · inoperativeEPSU EXT LOAD EMER RIGHT MESSAGE ON EMERGENCY LIGHT TEST PANEL.SDR 2008UALA00031Light · inoperativeEPSU EXT LOAD EMERGENCY RIGHT MESSAGE ON EMERGENCY LIGHT TEST PANEL. FWD LAMP RIGHT WING AFT OVERWING EMERGENCY LIGHT ASSY IN OUT. REPLACED RIGHT OVERWING EMERGENCY EXIT LIGHT, LAMPS OPS CHECKED OK.SDR 2007UALA05342Wire · unsecurePASSENGER SEAT ROW 10ABC, EMERGENCY EXIT LIGHT INOP. WIRES DISTURBED BY PASSENGER BAG OR FOOT. RESECURED WIRES, OPS CK'D GOOD.SDR 2007UALA05343Epsu · failedEMERGENCY LIGHT SYSTEM FAIL TO TEST. EPSU FAILURE. REPLACED EPSU 13WL. OPS CHECKED NORMALLY.SDR 2007UALA05384Skin · dentedBIRD STRIKE ON NR 3 SLAT ON LEFT WING, DENT MEASURES 6 X 3.5 (CHORDWISE), APPROX 0.5 INCH DEEP. LOCATED 0.31 25 INCHES FROM RIB RIVETS. REPAIRED NR 3 L/E SLAT WITH AN INSERT REPAIR AND PERFORMED BIRD STRIKE INSPECTION OF WHOLE A/C, NO FURTHER DAMAGE WAS NOTESDR 2007UALA05344Epsu · failedEMERGENCY LIGHTS ON WITH SWITCH ARMED. EPSU FAILURE. REPLACED EPSU 13WL. ALL LIGHTS NORMAL.SDR 2007UALA05318Engine · malfunctionedFLIGHT DIVERTED UNDER AMBER DUE TO NR 1 ENGINE PROBLEM.
SDR 2007UALA05337Slide · shortEMERGENCY LIGHTS TEST FAILS PER 3SVC PAPERWORK. FAULTS EPSU EXT LOAD FWD L. ELECTRICAL SHORT INSIDE SLIDE 1L. REPLACED SLIDE PACK 1L, OPS CHECKED NORMALLY.SDR 2007UALA05327B-Nut · looseOXYGEN SUPPLY LOW 1380 PSI. FOUND SLOW LEAK IN CREW O2 SYSTEM. TIGHTENED B-NUT AT REGULATOR AND RESERVICED CREW O2.SDR 2007UALA05341Cable · brokenRIGHT OVERWING EXIT INFLATION RESERVOIR CABLE BROKEN (INSIDE AFT PIT). REPLACED THE RESERVOIR ASSY, INCLUDING CABLE.SDR 2007UALA05312Power Supply · faultyEPSU INT LOAD EMER L 33-51-38 FAULT DURING TEST AFTER ESCAPE SLIDE 2L REPLACEMENT. EMERGENCY LIGHT SYS NEEDS REPAIR. FAULTY POWER SUPPLY FOR EMERGENCY LIGHTS (EPSU). REPLACED EPSU, OPS CHECKED GOOD.SDR 2007UALA05335Panel · crackedLEFT OVERWING SLIDE PANEL IS CRACKED AT THE FWD UPPER CORNER (MKD). DELAMINATION OF PANEL. REPLACED SLIDE ASSY.SDR 2007UALA05336Light · inoperativeEMERGENCY LIGHT AT AISLE SEAT 15C IS INOPERATIVE. FAULTY LIGHT ASSY. REPLACED LIGHT ASSY. OPS CHECKED OK.SDR 2007UALA05328Harness · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE CAPT O2 MASK SUPPLY SWITCH PINCHED OPEN IN STOWED POSITION. RESTOWED THE MASK CORRECTLY AND SERVICED CREW O2.SDR 2007UALA05213Connector · disconnectedRTFL DUE TO A ELECTRICAL BUSS FAULT. FOUND CONNECTOR 1PU2A COMPLETELY DISCONNECTED FROM TR2 UNIT. INSPECTED TR2 LOCKS FOR CONNECTOR 1PU2A AND CONNECTOR 1PU2A. NO DISCREPANCIES. RESECURED CONNECTOR TO TR2 AND PERFORMED DC MAIN GENERATION (TR) ADJ AND TEST- SDR 2007UALA05222Oxygen System · low pressureCREW OXYGEN SYSTEM - LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO PROPER SERVICE LEVEL.SDR 2007UALA05238Skin · damagedFUSELAGE SKIN AT FRAME 64 AND FRAME 65 AND STRINGER 23L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED AT DEN.SDR 2007UALA05250Oxygen Mask · unserviceableTOP LEFT STRAP ON CAPT O2 MASK NEEDS INSIDE KEEPER-FASTENER. REPLACED CAPT O2 MASK WITH A SERVICEABLE UNIT.SDR 2007UALA05251Lens · missingEEPM LIGHT SEAT 22C MISSING LENS. REPLACED LENS AT SEAT 22C (EEPM).SDR 2007UALA05208Structure · dentedDENT FOUND RUNNING IN A VERTICAL DIRECTION APPROX 3 FT FWD OF DOOR 2L. MAJOR REPAIR ACCOMPLISHED AT DEN.SDR 2007UALA05173Light · inoperativeEPSU EXT LOAD EMER R - FAULT FOUND ON 3 SVC EMERGENCY LIGHT TEST. OVERWING EMERGENCY WING LIGHTS INOP. REPLACED OVERWING EMERGENCY FLOOD LIGHTS.
SDR 2007UALA05190Battery · dischargedF/A FLASHLIGHT IS NOT FLASHING. *S/D* BATTERY FAILURE. REPLACED BATTERY.SDR 2007UALA05207Wire · chafedAFT PAX CABIN EMERGENCY LIGHTS ILLUMINATE AFTER ENGINE START. NUMEROUS WIRES FOR EPSU SYSTEM FOUND CHAFED AND OPEN. NO STRANDS BROKEN - INSULATION WORN TO BARE WIRE. UNKNOWN ROOT CAUSE. REPAIRED ALL WIRES FOUND DAMAGED, SYSTEM FUNCTIONS NORMALLY DURING TESSDR 2007UALA05124Slat System · lockedAIRCRAFT LANDED WITH SLATS LOCKED-FLAPS 3 IAW ECAM. REPLACED SFCC 2, OPS CHECKED GOOD.
SDR 2007UALA05127Wire · disconnectedWIRES THAT SUPPLY POWER TO THE EMERGENCY LIGHTS AT ROW 16ABC ARE PULLED UP. REPLACED AND RESECURED EEL LIGHT WIRING AT SEAT LOCATIONS 15,16 ABC.