IAE V2522-A5
Service difficulty reports · 3,465
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA03281Epsu · failedEMERGENCY LIGHT SYS FAILS 3SVC CHECK WITH MESSAGE EPSU UNIT EMER L. REPLACED LEFT EPSU.SDR 2007UALA03225Control Module · malfunctionedUNCOMMANDED NOSE WHEEL STEERING. NOSE GEAR STEERING SERVO CONTROL MODULE FAILURE. REPLACED NLG STEERING SERVO CONTROL MODULE.SDR 2007UALA03227Module · failedPLANE PULLS TO RIGHT ON TAXI AND ON T/O AND LANDING. FOUND STEERING ELECTRO-HYD MODULE 6GC FAILED. REPLACED STEERING ELECTRO-HYD MODULE 6GC. NO REPEATS SINCE ORIGINAL.SDR 2007UALA03203Actuator · leakingLOST GREEN HYD RESERVOIR FLUID. *S/D* LEAKING YAW DAMPER ACTUATOR. REPLACED YAW DAMP ACT, SERVICED GREEN SYS HYDRO - NO REPEATS SINCE ORIGINAL.SDR 2007UALA03117Lamp · inoperativeEEL AT SEAT ROW 16 ABC INOPERATIVE. REPLACED EMERGENCY LIGHT LAMP OPS CHECK OK.SDR 2007UALA03120Lens · brokenSEAT 11C EMERGENCY ESCAPE PATH RED LIGHT LENSE BROKEN. REPLACED THE LENS.SDR 2007UALA03118Skin · dentedFUSELAGE DENT REPORTED BY RAMP AFTER ACFT DEPARTURE. DENT ON RIGHT SIDE FUESLAGE 6.75 INCHES AFT OF FRAME 12 WHICH IS FWD OF THE DOOR 1R & JUST ABOVE FLOOR LINE. MAJOR REPAIR ACCOMPLISHED AT HMV.SDR 2007UALA03119Disc · missingTHE 2L & 2R SLIDE PRESS INDICATOR CLEAR DISC MISSING. REPLACED INDICATOR DISC.SDR 2007UALA03094Warning Message · false indicationUNEXPLAINED FUEL TRANSFER AND IMBALANCE. COULD NOT DUPLICATE CONDITION ON GROUND. RAN SEVERAL TESTS INCLUDING EXAMINING AIR RELEASE FLOAT VALVE, DEFUELING ACTUATOR FOR PROPER OPS, FLSS STATUS, ALL NORMAL. TESTED ALL QTY PROBES. ON PREFLIGHT, QTY PROBE 26QTSDR 2007UALA03092Engine · stalledECAM WARNING ENGINE 2 STALL. 09-07-07 NR 2 ENG STALL IN CLIMB FROM 370-380. ENGINE RECOVERED IMMEDIATELY ON ITS OWN WITH NO INPUT. REPLACED NR 2 LT HP 7 STAGE VALVESDR 2007UALA03095Fire Bottle · dischargedFWD LAV GARBAGE CAN FIRE EXTINGUISHER BOTTLE EMPTY. 09-07-07 REPLACED FIRE BOTTLESDR 2007UALA03096Slide · unserviceableRIGHT OVERWING SLIDE UNSERVICEABLE. WATER CONTAMINATION/INTRUSION REPLACED SLIDE.SDR 2007UALA03057Sign · unsecureFOUND EMERGENCY EXIT SIGN JUST FWD OF DOOR 1R BROKEN UNSECURE. 09-07-07 REPAIRED/REPLACED HARDWARE, EXIT SIGN RESECURED.SDR 2007UALA03065Swivel · leakingRTFL DUE TO GREEN HYDRAULIC SYSTEM FAILURE. 09-07-07 BROKEN HYD SWIVEL FITTING ON GEAR. REPLACED BROKEN SWIVEL FITTING. RESET ALL SYSTEMS.SDR 2007UALA02991Seat Track · damagedRIGHT INBOARD & OUTBOARD SEAT TRACKS FROM FR 41 TO FR 51 HAVE SCRATCHES AND GOUGES BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED: REPLACED SEAT TRACK.SDR 2007UALA02954Floorbeam · corrodedCABIN FLOORBEAM Y-765 (RBL 30) UPPER FLANGE HAS EXFOLIATION CORROSION - 1 TO 2 INCHES FWD OF FRAME C20. REPLACED FLOORBEAM.SDR 2007UALA02955Floorbeam · corrodedCABIN FLOORBEAM Y-254 (RBL 10) UPPER FLANGE HAS EXFOLIATION CORROSION FROM FRAME C19 TO FRAME C20 AND UNDER THE GALLEY FLOORBOARD. REPLACED FLOORBEAM.SDR 2007UALA02933Floorbeam · corrodedCABIN FLOORBEAM Y-1292 (RBL 51) UPPER FLANGE HAS EXFOLIATION CORROSION FROM FRAME C17 TO FRAME C20. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED CABIN FLOORBEAM.SDR 2007UALA02956Oxygen Mask · faultyF/O OXYGEN MASK DOES NOT FULLY INFLATE. SHOP FINDINGS INDICATE A CRACKED MAIN CASE WHICH WILL ALLOW LEAKAGE TO OCCUR. MASK REMOVED AND SENT TO SHOP FOR COMPLETE OVERHAUL. NEW MASK INSTALLED ON A/C.SDR 2007UALA02967Proximity Sensor · faultyRTFL DUE TO CABIN DOOR INDICATION PROBLEM. REPLACED PROX SENSOR.SDR 2007UALA02973Oxygen Mask · no testF/O'S OXYGEN MASK WILL NOT TEST. NO SHOP FINDINGS COULD BE LOCATED FOR THIS UNIT- FO'S O2 BOX WAS REPLACED ON AIRCRAFT- NO REPEATS SINCE ORIGINAL.SDR 2007UALA02943Warning System · malfunctionedCREW COMMENTS: LANDING GEAR SYSTEM DISAGREE ECAM UPON LANDING, WENT AWAY AFTER 30 SECONDS. REPLACED PROX SENSOR 29GA AND LGCIU2. NO REPEATS SINCE ORIGINAL.SDR 2007UALA02915Harness · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). REPLACED CREW O2 HARNESS.SDR 2007UALA02866Unknown · odorSTRONG ELECTRICAL FUMES REPORTED IN AFT GALLEY. NO FURTHER INCIDENTS AS OF 8/22/07, UNABLE TO DUPLICATE SMELL,SDR 2007UALA02884Bottle · reads lowDOOR 1R DOOR ASSIST BOTTLE LOW. LOW CYLINDER PRESSURE (UNKNOWN) SERVICED CYLINDER TO PROPER PRESSURE, NO REPEATS.SDR 2007UALA02901Light · unsecureFOUND SEAT 7C EEPM LIGHT HANGING OUT OF SEAT. REPLACED SEAT EEPM.SDR 2007UALA02902Lamp · inoperativeSMALL LOWER EMERGENCY EXIT SIGN AT DOOR 2L HAS ONE INOP LAMP. RELAMPED SIGN.SDR 2007UALA02903Lamp · inoperativeEMERGENCY ESCAPE PATH LIGHTING AT SEATS 13C, 14C AND 18C HAVE ONE INOP LAMP. RELAMPED SEAT LOCATIONS NOTED.SDR 2007UALA02864Oxygen Mask · leakingCREW O2 AT 750 PSI. *S/D* 2ND OBSERVERS MASK LEAKING. REPLACED 2ND OBSERVERS MASK AND SERVICED CREW O2 SYSTEM.SDR 2007UALA02797Check Valve · failedUNWANTED FUEL TRANSFER FROM RT WING TO CTR TANK. TRANSFER RATE APPROX 500 LBS PER HOUR. CENTER BOOST PUMP CHECK VALVE LEAKING FUEL. REPLACED CENTER BOOST PUMP CHECK VALVE.SDR 2007UALA02760Hydraulic System · inoperativeFLIGHT DIVERTED DUE TO LOSS OF BLUE HYDRAULIC SYSTEM. LOSS OF HYDRAULIC FLUID DUE TO LEAK AT MOUNTING POINT FLANGE OF THE ELECTRIC HYD PUMP. REPLACED BLUE ELECTRIC HYDRAULIC PUMP, SERVICED SYSTEM.SDR 2007UALA02737Power Supply · faultyWHILE PERFORMING CABIN EMERGENCY LIGHTING CHECK RECEIVED MESSAGE -EPSU INT LOAD AFT-L- ON FWD ATTENDANT PANEL. RESET AFT GALLEY CEILING AREA POWER SUPPLY. TEST PASS.SDR 2007UALA02734Steering Sys · failedNOSE WHEEL STEERING FAILED ON TAXI OUT. FOUND SERVO 6GC FAILURE. REPLACED SERVO 6GC. OPS CHECK GOOD.SDR 2007UALA02634Unknown · odorFLIGHT ATTENDANT REPORTING ELECTRICAL ODOR AROUND ROW 20, COOLED DOWN THE TEMP AND SHUT OFF LIGHTS AND ODOR IS DISSIPATING. INSPECTION DONE OF AREA, TURNING OFF AND ON LIGHTS AND AIR. NO ODORS NOTED. NO REPEATS SINCE ORIGINAL.SDR 2007UALA02614Panel · damagedNR 1 ENGINE FWD PYLON CANTILEVER PANEL IS DAMAGED. REPAIRED FAIRING.SDR 2007UALA02592Smoke Detector · inoperativeFWD LAV SMOKE DETECTOR INOP (TEST INOP). REPLACED FWD LAVATORY SMOKE DETECTOR.SDR 2007UALA02549Slide · damagedRAMP REPORTS LT OVERWING SLIDE PACK DOOR HAS A VERTICAL CRACK ON AFT EDGE. REPLACED SLIDE ASSYSDR 2007UALA02455Pitch Control · malfunctionedAIRCRAFT HAS CONSTANT TRIM PITCH UP AND PITCH DOWN CONDITION. CONDITION SAME WITH EITHER AUTOPILOT ENGAGED. REPLACED ACCELEROMETER 12CE3 PER TSM 27-30-00-810-853.PERFORMED MCDU TEST OF EPCS1.NO FAILURE MSSGS NOTED. REPLACED ACCEL 12CE4 AND THS POSITION TXDSDR 2007UALA02459Light · failedCABIN EMERGENCY LIGHTS FAILED TEST. [07-24-07] OPS CHECKED OK.SDR 2007UALA02453Sensor · malfunctionedNO NOSE WHEEL STEERING ON TAXI OUT. PROXIMITY SENSOR 28GA FAILURE. REPLACED PROXIMITY SENSOR 28GA.SDR 2007UALA02454Elevator · failedRIGHT ELEVATOR FAILED ELEVATOR DAMPING TEST. REPLACED ELEV ACTUATOR 34CE2, RETEST- TESTED OK.SDR 2007UALA02418Oil System · leakingCREW REPORT, 280 MILES FROM DESTINATION GOT BURNED AIR COND DUCT OR OVERHEAT ODOR FROM ROW 10 TO COCKPIT. APU OIL LEAKING INTO BLEED AIR SYSTEM. APU REMOVED AND REPLACED.SDR 2007UALA02419Battery · dischargedEMERGENCY LIGHTS FAIL TEST PER 3SVC FOR AFT LEFT BATTERY. REPLACED AFT ESPU BATTERY FOR A SECOND TIME, SYSTEM PASSED TEST.SDR 2007UALA02382Light · inoperativeSEAT EEL LIGHT ASSY HAS ONE BULB INOP. LIGHT ASSY DAMAGED. REPLACED LIGHT ASSY.SDR 2007UALA02360Engine · overtempNR 2 ENGINE OVERTEMP ON START 717 DEG, 30 SEC.SDR 2007UALA02328Flange · crackedLEFT OFFWING ESCAPE SLIDE HAS A CRACK IN VERTICAL AFT FLANGE LOWER END.SDR 2007UALA02329Bottle · damagedDOOR 2L DOOR ASSIST BOTTLE DIAPHRAGM BLOWN.SDR 2007UALA02295Flange · crackedRIGHT OFFWING ESCAPE SLIDE HAS A CRACK IN VERTICAL AFT FLANGE LOWER END, (AREA 2) 5 INCHES. REPLACED RT OVERWING SLIDE.SDR 2007UALA02270Fire Warning · false activationAPU FIRE DISCHARGE LIGHT ILLUMINATED. REPLACED APU FIRE BOTTLE AND CLEANED APU COMPARTMENT. NO FURTHER REPEATS SINCE THE ORIGINAL. UNKNOWN AS WHAT CAUSED THE BOTTLE TO FIRE IN THE FIRST PLACE.
SDR 2007UALA02186Light · missingEMERGENCY EXIT GUIDANCE LIGHT AT 1B MISSING. REPLACED LIGHT ASSEMBLY.
Back to IAE V2522-A5