SDR 2007UALA04036Battery Pack · faultyEMERGENCY LIGHT TEST FOUND BATTERY FAULT AFT GALLEY AREA. 10-19-07 FOUND EPSU FAULTED. REPLACED EPSU.SDR 2007UALA04037Power Supply · inoperativeFOUND OVERWING EMERGENCY LIGHTS, LT AND RT SIDES INOP. 10-19-07 FOUND EPSU FAILED. REPLACED EPSU AND OPS CHECKED GOOD.
SDR 2007UALA03974Stator Vane · lack of lubeABORTED TAKEOFF DUE TO NR 2 ENGINE COMPRESSOR STALL. *S/D* ACP POWER ASSURANCE, ACCEL AND DECEL CHECKS, ACCOMPLISHED POWER ASSURANCE RUNS, ALL PARAMETERS NORMAL, ACCEL 6 SECONDS, DECEL 3 SECONDS, ALL NORMAL NO MESSAGES. ACCOMPLISHED CHECK INSP OF VSV, LUBRSDR 2007UALA03982Liner · damagedFOUND HOLE INSIDE NR 1 ENGINE COWL ON WALK AROUND, UNDER ENG BLADE, APPROX 2 INCHES LONG AND 1 INCH WIDE. HOLE IS AT 6 O'CLOCK POS. MEASURES APPROX .75 INCH DIA. *S/D* REPAIRED NR 1 ENG FAN CASE ATTRITION LINER, CURED FOR 3 HOURS WITH HEAT LAMP.SDR 2007UALA03983Attach Fitting · faultyFWD LEFT MED SLIDE FWD LOWER ATTACH FITTING BROKE. REPLACED FWD LEFT SLIDE ASSY.SDR 2007UALA03947Battery · failedEMERGENCY POWER SUPPLY UNIT BATTERY L FAILED CHECK. REPLACED LT EPSU BATTERY AT OVERWING EXIT. OPS CHECK GOOD.SDR 2007UALA03960Selector · malfunctionedGEAR DID NOT EXTEND, USED GRAVITY EXTENSION AND LOST NOSE STEERING, TOWED TO GATE. 10-19-07 FOUND AFT MLG DOOR SELECTOR VALVE INOPERATIVE. REPLACED AFT MLG DOOR SELECTOR VALVE 41GA AND 37GA. DOORS OPEN AND CLOSE NORMALLY. NO REPEATS SINCE ORIGINALSDR 2007UALA03969Angle · damagedFWD PIT RE-ENFORCING ANGLE ON STR 42R FROM FR28 TO FR31. MAJOR REPAIR ACCOMPLISHED: REPLACED -L- ANGLE DOUBLER.SDR 2007UALA03913Battery · failedBATTERIES AT EMERGENCY EXIT LEFT AND RIGHT FAILED TEST. *S/D* FAULTY BATTERIES. REPLACED BOTH LEFT AND RIGHT EMERGENCY EXIT LIGHT BATTERIES, OPS CHECK GOOD.
SDR 2007UALA03942Seat Track · damagedFOUR EA SEAT TRACKS HAVE LUGS WORN BEYOND LIMITS. WEAR IS WHERE FWD SEAT LEG ANTI-RATTLE NUTS ARE LOCATED. THE 4 TRACKS ALL RUN FROM FR41 THRU FR 47-51 AND ARE THE LEFT I/B, LEFT O/B, RIGHT I/B AND RIGHT O/B TRACKS. MAJOR REPAIR ACCOMPLISHED: REPLACED SEATSDR 2007UALA03946Power Supply · failedACFT FAILED CABIN EMERGENCY LIGHT CHECK ITEM 2 ON 3 SVC. POWER SUPPLY FAULT/FAILURE. REPLACED POWER SUPPLY 11WL AND RELAMPED 63WL, 61WL. OPS CHECK NORMAL AFTER MTX.SDR 2007UALA03912Psu · no testDURING OPERATIONAL CHECK OF PASSENGER EMERGENCY OXYGEN SYSTEM, ROWS 12,18 LEFT AND 21, 22 AND 24 RIGHT FAILED TO DROP. *S/D* REPLACED O2 CONTAINERS AT LOCATIONS THAT FAILED TO OPEN. CHECKED AND ADJUSTED RIGGING. TESTED AGAIN AND ALL ARE NORMAL.SDR 2007UALA03895Valve · misriggedENGINE NR 1 COMPRESSOR STALL IN CRUISE. MISRIGGED VSV SYSTEM. ACP CHECKS PER MM 71-00-00 FOUND VSV UNISON RING MISRIGGED AT VGV AND STAGE 5. ADJ 1 TURN EA, OPS CHECK NORMAL.SDR 2007UALA03877Wire · crushedF/O'S OXYGEN MASK MICROPHONE IS INOPERATIVE. *S/D* MIC WIRE DISCONNECTED/CRUSHED. REPLACED MASK ASSY, OPS CHECK OK.SDR 2007UALA03821Power Supply · failedFWD EMERGENCY LIGHT POWER SUPPLY FAIL TEST PER 3 SVC.SDR 2007UALA03820Connector · dirtyCABIN EMERGENCY LIGHT TEST FAIL. MSG - EPSU INT LOAD EMER L.SDR 2007UALA03822Oxygen Mask · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING).
SDR 2007UALA03823Oxygen Mask · inoperativeSECOND OBS QUICK DONNING MASK INOP.SDR 2007UALA03824Seat Track · gougedLEFT INBOARD SEAT TRACK FROM FRAME 42 THROUGH 47-51 IS GOUGED BEYOND LIMITS.SDR 2007UALA03789Floorbeam · gougedRIGHT I/B FLOORBEAM FROM FRAME 42 THROUGH 47-51 IS GOUGED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED: REPLACED SEAT TRACK.SDR 2007UALA03790Seat Track · gougedLEFT O/B SEAT TRACK FROM FRM 42 THRU 47-51 IS GOUGED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED: REPLACED SEAT TRACK.SDR 2007UALA03800Exhaust Duct · crackedNR 1 ENG TAILCONE HAS MANY CRACKS AT THE ATTACH WELD MOUNTS. OVER 12 INCHES TOTAL LENGTH OF CRACKS.SDR 2007UALA03781Oxygen Mask · unwanted deployOXYGEN MASKS AT 2AB DEPLOYED ON TAKEOFF.SDR 2007UALA03782Oxygen Mask · unwanted deployTHE 11 DEF OXYGEN MASKS DEPLOYED ON LANDING.SDR 2007UALA03748Structure · unserviceableOXYGEN BOX ASSY IS UNSERVICEABLE.SDR 2007UALA03715Accumulator · reads lowDOOR 2R EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW.SDR 2007UALA03702Lamp · burned outEEL LIGHT AT SEAT 16 ABC HAS ONE BULB OUT. RELAMPED EEL, OPS CHECK GOOD.SDR 2007UALA03665Epsu · faultyRIGHT EPSU FAULT ON EMERGENCY LIGHT TEST.SDR 2007UALA03666Warning System · activatedLANDING GEAR NOT LOCKED MSG ON UPPER ECAM WITH HORN & ALERT LIGHTS ILLUMINATED.SDR 2007UALA03661Rod End · wornFLIGHT ATTENDANTS STATED FELT SUBSTANTIAL VIBRATION IN AFT CABIN AND FORWARD CABIN FOR ABOUT 1 MIN. FOUND EXCESSIVE RUDDER FREE PLAY IN THE SERVO ROD ENDS. REPLACED ALL THREE RUDDER SERVO ROD ENDS. AT HMV, RUDDER HINGE BEARINGS REPLACED, ELEV HINGE BEARINGSSDR 2007UALA03621Skin · damagedLEFT WING CUTOUT FOR FUEL TANK PNL 540KB HAS 2 EA FASTENER HOLES FOR ATTACHMENT OF THE NUT PLATE CHANNEL TO THE WING SKIN ELONGATED BEYOND LIMITS. COLD WORKED FASTENER HOLES AND INSTALLED NEW REPAIR BUSHINGS.SDR 2007UALA03627Light · inoperativeEEL LIGHT 1 EA BULB OUT AT SEAT 13C, 12C, 10C FWD COAT CLOSET. REPLACED LAMPS, OPS GOOD.SDR 2007UALA03617Oxygen System · lowGATE CAPT FOUND 02 LOW. SERVICED THE O2 SYSTEM TO PROPER LEVELS. NO REPEATS SINCE ORIGINAL.SDR 2007UALA03599Seal · leakingAPU SMOKING UPON ARRIVAL INTO SFO AT GATE WITH OIL COMING OUT OF TAILPIPE. REPLACED APU. MANUFACTURER CHANGED EPOXY IN '06. UAL'S 1ST INCIDENT OCCURRED 12/23/06 AND HAS HAD 6 ADDITIONAL INCIDENTS SINCE. 4026 WAS THE 1ST SDR AND THE LAST OCCURRANCE. MANUFACTUSDR 2007UALA03605Compressor · stalledNR 1 ENGINE COMPRESSOR STALL CAUSED BY CLEAR AIR TURBULENCE - MOUNTAIN WAVE. ACCOMPLISHED BOROSCOPE OF COMPRESSOR SECTION OF ENGINE-RESULTS NORMAL, ACCOMPLISHED TEST OF 7TH AND 10TH STAGE SOLENOID AND POTS AND FOUND 10TH STAGE POT FAILING-REPLACED 10TH STAGSDR 2007UALA03584Skin · damagedEVIDENCE OF LIGHTNING STRIKE IN SKIN 8 INCHES FWD OF FRAME 30, .5 INCH BELOW STR 41L. MAJOR REPAIR OF SKIN, 8" FWD OF FRAME 30, .5 INCH BELOW STR 41L- EXTERNAL DOUBLER REPAIR AND INTERNAL STRINGER REPAIR ACCOMPLISHED.SDR 2007UALA03590Mask · malfunctionedTHE O2 MASKS AT 11DEF, 23ABC AND D LAV DO NOT DROP DURING DROP CHECK. FOUND IMPROPER PACKING. REPACKED MASKS AND PERFORMED DROP AGAIN. OPS CHECKED NORMAL.SDR 2007UALA03598Smoke Detector · dirtyECAM MESSAGE SMOKE DETECTOR MESSAGE DOOR 1L FWD. SMOKE DETECTOR DIRTY. REMOVED, CLEANED AND REINSTALLED SMOKE DETECTOR IN FWD LAV A. OPS CHECK NORMAL.SDR 2007UALA03504Guard · missingEMERGENCY LIGHT SW GUARD ON THE AFT F/A PANEL IS MISSING. REPLACED EMERGENCY SWITCH LIGHT AT AFT GALLEY.SDR 2007UALA03508Cylinder · low pressureNR 2 RIGHT PASSENGER DOOR EMERGENCY CYL-ACCUM PRESSURE LOW. SERVICE DOOR ASSIST CYLINDER TO PROPER PRESSURE,SDR 2007UALA03505Smoke Detector · inoperativeDOOR 2L FWD LAV SMOKE DETECTOR IS INOPERATIVE. REPLACED FWD AFT LAV SMOKE DETECTOR. TESTED OK ON SDCU.SDR 2007UALA03507Light · faultyFWD CLOSET EMERGENCY LIGHT IS FAULTY. REPLACED FWD CLOSET EMERGENCY LIGHT ASSY.SDR 2007UALA03510Panel · damagedPANEL ON NR 2 PYLON IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER/FILLER REPAIR ON PANEL 424CR. INSTALLED PANEL ONTO NR 2 PYLON.SDR 2007UALA03506Stringer Splice · corrodedAFT STRINGER SPLICE IS CORRODED AT FR 51 ON STR 43L. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER SPLICE.SDR 2007UALA03492Power Supply · faultyCABIN EMERGENCY LIGHT FAULT EPSU INTERNAL LOAD RIGHT. REPLACED EPSU.SDR 2007UALA03461Computer · malfunctionedELAC 2 FAULT DISPLAYED ON UPPER ECAM SCREEN, - F-CTL. AIRCRAFT STARTED UNCOMMANDED FLIGHT MOVEMENT IN A DOWN PITCH BEFORE ECAM AND AFTER FAULT NO FURTHER UNCOMMANDED MOVEMENT. RESET ELAC2 AND PERFORMED GROUND SCAN- NO PROBLEMS NOTED, NO REPEATS SINCE ORIGINSDR 2007UALA03474Battery · failedEMERGENCY LIGHTS FAIL TEST AT CIDS PANEL. FOUND LEFT EPSU BATTERY FAILURE. REPLACED LT EPSU BATTERY. OPS CHECKED GOOD.SDR 2007UALA03441Lamp · burned outRIGHT FWD OVERWING LIGHT INOPERATIVE. FOUND LAMP BURNED OUT. REPLACED LIGHT ASSY.SDR 2007UALA03436Sign · brokenEMERGENCY EXIT SIGN JUST FWD OF DOOR 1R BROKEN UNSECURE. REPLACED LIGHT ASSY. OP CHECKS GOOD.SDR 2007UALA03260Battery · weak3 SERVICE CABIN EMERGENCY LIGHTING CHECK GIVES THE MESSAGE EPSU INT LOAD EMERGENCY LIGHT. FOUND WEAK BATTERY. REPLACED AFT LT EMERGENCY LIGHT BATTERY.