SDR UALA2009042901245Battery Pack · failedAFT LEFT BATTERY HAS FAULTED. REPLACED BATTERY, EMERGENCY SYSTEM TEST PASS.SDR UALA2009042901249Wire · brokenEMERGENCY LIGHT AT 20C INOP, SUSPECT BROKEN WIRE. REPLACED EMERGENCY LIGHT ASSY. LIGHT OP CHKS OK.SDR UALA2009042901252Rectifier · unreliableTR 2 FAULT ECAM. RTFL, TROUBLESHOOTING BUT UNABLE TO DUPLICATE. REPLACED TRANSFORMER RECTIFIER.SDR UALA2009042901244Attach Bracket · brokenACCOMPLISH DOOR 1 LEFT SLIDE REMOVAL INSTALLATION AND INSPECTION FOR TRAINING PURPOSES. DURING INSPECTION OF DOOR 1 LEFT SLIDE, FOUND FWD LOWER ATTACH BRACKET BROKEN. REPLACED BRACKET.SDR UALA2009042901248Power Supply · no testEPSU BAT AFT L MESSAGE ON CIDS TEST PANEL FAILED TEST. RESET EMERGENCY LIGHTS SYSTEM AFT LEFT POWER SUPPLY. EMERGENCY LIGHTS TEST GOOD.SDR UALA2009042901241Girt Bar · out of adjustDOOR 2 RT DOES NOT SHOW SLIDE ARMED IN FLT. CREW REPORTS WHEN PUSHING DOWN ON ARMING HANDLE SLIDE INDICATION IS NORMAL, ONCE PRESSURE IS OFF, SLIDE SHOWS DISARMED ON ECAM AGAIN. DOOR 2R SLIDE REMOVED FOR ACCESS. ADJUSTED AFT GIRT BAR FOOT DOOR ARMING SYSTEM. SDR UALA2009042701200Structure · damagedINSTALLED TWO NEW DOUBLERS WITH ZERO TIMED HOLES PER COA407081 REF DRAWING 60N00001. ACP COA 407081.SDR UALA2009042701201Light · inoperativeAISLE SEAT EEL LIGHTS ARE INOP AT SEAT 7 AND 15A. REPLACED LIGHT ASSY, OPS CHECKED GOOD.SDR UALA2009042401189Bulb · inoperativeCABIN EMERGENCY LIGHT CHECK FAILS TEST. MSG INT LOADS AFT L APPEAR AT END OF TEST. RELAMPED 1 EA BURNED OUT BULB IN EXIT SIGN ABOVE DOOR 2L. EMERGENCY LIGHT TEST OKAY.SDR UALA2009042701196Skin · damagedLWR FUSE SKIN REMOVE TWO AFA25-0063-1 ANTENNAS AT APPROX STA 1185 AND INSTALL DOUBLERS PER DE-TED JC 4C070 8148. ACP RPR PER SFOOV DE-TED J/C 4C0708148.SDR UALA2009042701197Power Supply · faultyAIRCRAFT FAILS EMERGENCY LIGHT TEST 'UNIT EMER L' FAULT. REPLACED POWER SUPPLY, NOW HAVE INTERNAL AND EXTERNAL LOAD EMER L FAULT, RELAMPED BOTH LEFT OW EXT LIGHTS, STILL FAULTS. SUSPECT OW SLIDE. FOUND SEAT 15, 16 AND 17 EEL LIGHTS DIM. NEEDS MORE T/S TO FSDR UALA2009042301179Battery · dischargedEMERGENCY LIGHTS TEST FAILS. FAULTS EPSU BAT AFT L. REPLACED BATTERY AT 13WL.SDR UALA2009042401186Hose · unserviceableHYDROSTATIC HOSE DAMAGED. UNKNOWN POSSIBLE MANUFACTURING DEFECT. REPLACED HYDROSTATIC HOSE WITH A NEW ONE.SDR UALA2009042101156Skin · corrodedFOUND CORROSION IN THE BELLY SKIN BELOW THE FWD-PIT DOOR. DETERIORATION COMPLETELY THRU SKIN. SKIN REPAIR IS COMPLETE, CLOSING UP. SEALED & PAINTED.SDR UALA2009042401191Panel · no testCARGO SMOKE SYSTEM DOES NOT TEST CORRECTLY. REPLACED ANNUNCIATOR LIGHT PANEL 11LP, OP CHECKS NORMAL.SDR UALA2009042101160Skin · damagedREMOVE TWO (2) AFA25-0063-1 ANTENNAS, FROM THE LOWER SKIN, AT APPROX STA 1185. MAJOR REPAIR ACCOMPLISHED. REMOVED ANTENNAS AND INSTALLED DOUBLERS PER DE-TED JC 4C0708148.SDR YENA20090421037Idg · leakingFLT 754, CUN-JFK, DURING TAKEOFF AT 500FT NR 2 ENG VIBRATION FOLLOWED BY IDG 2 LOW OIL N1 VIBRATION SHOWED 3.6 AFTER IDG DISCONNECTED, AIR TURNBACK TO CUN. REMOVED AND REPLACED NR 2 IDG IAW AMM 24-21-51, OPS AND LEAK CHECK GOOD. N1 VIBRATION WITHIN LIMITS IASDR UALA2009042101166Slide · faultyDOOR 2R SLIDE ARMED INDICATION INOP IN FLT. PERFORMED TSM TASK 52-13-0 0-810-809. REPLACED IND LT-SLIDE ARMED ASSEMBLY, AFT R DOOR (3WN 2), AND REPLACED 7WN2 PROX SW HANDLE, R AFT ESC SLIDE. PERFORMED OP-TEST OF EMERGENCY ESCAPE SLIDE RELEASE SYSTEM OF PASSSDR UALA2009042001142Slide · out of toleranceNR 2R DOOR SLIDE OUT OF TOLERANCE. SLIDE WAS REPLACED.SDR UALA2009042001134Light · damagedEEL LIGHT DAMAGED 19C, 22C. REPLACED EEL LIGHT ASSY.SDR UALA2009042001137Engine · vibrationCREW REPORTS COMING OUT OF FL220 CREW EXPERIENCED NR 1 ENGINE VIBRATION OF 7.5 UNITS AND THE A3 BREAKER TRIPPED, WITH ENGINE AT IDLE THERE IS STRONG AIRFRAME VIBRATION AND 1.5 UNITS INDICATED ON THE ENGINE. REPLACED ENGINE. REPLACED ENGINE DUE TO CHAFFED WIRSDR UALA2009042001147Mask · defectiveF/O FWD O2 MASK PRESS TO TEST WHITE BUTTON NOT WORKING. REPLACED FWD MASK AND STORAGE COMPARTMENT.SDR UALA2009041701114Skin · damagedREMOVE TWO (2) AFA ANTENNA`S FROM THE LWR S SKIN AT APPROX STA 1185. MAJOR REPAIR ACCOMPLISHED. REMOVED AND INSTALLED DOUBLERS PER JC 4C0708148.SDR UALA2009041501091Cover · brokenCREW OXYGEN BOTTLE GAUGE COVER BROKEN, DAMAGED AND LOOKS LIKE ITS TAPE TO BOTTLE. REPLACED BOTTLE WITH CORRECT FITTING.SDR UALA2009041601097Slide · faultyCABIN EMERGENCY LIGHT TEST FAILED. FAULTS \EXT LOADS AFT L. INSTALLED SERVICABLE CONTROLLER & BATTERY. RAN TEST STILL FAULTS 'EXT LOADS AFT L 33-51-38'. RETURNED ORIGINAL UNIT BACK TO ACFT, SUSPECT EMERGENCY SLIDE EITHER LT OR RT. REPLACED LT AFT DOOR SLISDR UALA2009041501092Doubler · wornWING T/E DOUBLER AT AFT END OF PYLON WHERE HYD LINES GO THRU BOTTOM OF WING, DOUBLER COMPLETELY WORN THRU AT HYD LINE FLANGE ATTACH BOLTS. REPAIR ACP PER EVA 72495.SDR UALA2009041601095Connector · damagedELECTRIC ODOR IN PAX CABIN. SUSPECT PAX ENTERTAINMENT SYSTEM. UNDER SEAT SBB PCN 582-0051 ODOR IS LIKE ELECTRICAL. CABLE RDAM6852-4 (565-1415) HAS MALE PIN STUCK IN HARNESS CONNECTOR. REQUIRES SEB AND HARNESS. PERFORMED OP TEST ON PTP PANEL. ALL SYS WORKSDR UALA2009041301054Valve · malfunctionedWATER PRESSURE ISSUE. RTFL. FOUND WATER TANK FULL AND FILL VALVE CLOSED. CREW REPORT, THERE WAS WATER PRESS ON GROUND, BUT NONE AFTER DEPARTURE. TANK DRAINED. LAV AND GALLEY DRAINS NOT AFFECTED. TRIED TO PRESSURIZE WITH ENGINES AND APU AIR, NO JOY. WATESDR UALA2009041301047Unknown · odorON TOUCHDOWN F/A IN AFT JUMP SEAT DETECTED SMOKE. ODOR WENT AWAY UPON TURNING OFF ALL CHILLERS. RAN CHILLERS, COFFEEMAKERS AND OVENS IN AFT GALLEY FOR 20 MINUTES, NO SMELL NOTED. ALSO CHECKED WATER HEATERS IN AFT LAVS, NO ODOR NOTED. NO FURTHER MAINT ACTIOSDR UALA2009040801018Hydraulic Line · leakingGREEN HYD LOSS. FLIGHT DIVERTED. CREW REPORTED, SHUT THE GREEN HYD SYSTEM OFF BEFORE COMPLETE LOSS OF HYD, STILL HAD 2.5 GALLONS IN RSVR. FOUND THE GREEN PRESSURE LINE LOCATED IN THE NR 1 ENG PYLON SWEDGE LEAKING. REPLACED LEAKING LINE. SERVICED GREEN SYSSDR UALA2009040901025Light · inoperativeEXTERIOR EMERGENCY LEFT MESSAGE ON EMERGENCY LIGHT TEST. RELAMPED LT EXT OVERWING ILLUM LIGHTS, RE-RAN EMERGENCY LIGHT OPS TEST, OPS NORMAL.SDR UALA2009040800998Wire · brokenCABIN EMERGENCY LIGHT TEST FAILED, EPSU INT AND EXT LOAD AFT LEFT, BOTH FAULTS FLASHING ON PSU. FOUND POWER SUPPLY 13WL INTERNAL BITE INOP. REPLACED 13WL BITE NOW WORKS. CABIN EMERGENCY TEST STILL HAS SAME FAULTS. SUSPECT RIGHT AFT EMERGENCY SLIDE. FOUND SDR UALA2009040801000Power Supply · faultyDURING NR 3 SERVICE CHECK THE CABIN EMERGENCY LIGHT CHECK FAILED. EPSU INT LOAD AFT L FAULT. BITE TEST ON THE EPSU AT DOOR 2-LEFT SHOWS SAME FAULT. REPLACED EPSU AND BATTERY AT DOOR 2-LEFT (13WL). OPS TEST OK.SDR UALA2009040801001Valve · failedCABIN TEMPERATURE PROBLEM. RTFL. REVIEWED POST FLIGHT REP, FAILURE MSG TRIM AIR PRESS VALVE OR PRESS SWITCH. REPLACED TRIM AIR PRESS REG VALVE 14HK. RAN BOTH PACKS FROM BOTH ENGINES TO VERIFY NO FURTHER FAULTS. NO DEFECTS OBSERVED.SDR UALA2009040600973Pump · failedB-ELEC PUMP OVHT DISPLAYED ON UPPER ECAM SCREEN. RTFL. REPLACED BLUE HYD PUMP AND CASE DRAIN FILTERS. LEAK CHECK OK.SDR UALA2009040600983Oxygen Mask · leakingCREW REPORT: CAPT OXYGEN MASK LEAKING. REPLACED OXYGEN MASK.SDR UALA2009040300959Light · inoperativeSEAT MOUNTED EVAC LIGHTS INOP AT SEAT 14 AND 23 ASSYS BROKEN. WILL NEED TWO. RELAMPED 23 AND REPLACED LIGHT ASSY AT 14. OPS CHECK OKAY.SDR UALA2009040200945Structure · damagedRT OUTBOARD TRAILING EDGE FLAP DAMAGED BY BIRD STRIKE. FOUND RT MOST OUTBOARD LEADING EDGE FLAP WITH ONE QTR IN. PUNCTURE ABOVE 4 IN. CRACK FOLLOWED BY A 2 AND A HALF INCH LONG CRACK. BOTH CRACKS ARE WITHIN HALF AN INCH APART. REMOVED RT O/B FLAP LEADING SDR UALA2009033000916Power Supply · dischargedEMERGENCY LIGHT TEST FAILS, SAYS EPSU UNIT AFT LEFT, RESET NO HELP. EPSU UNIT FAULT LIGHT DISPLAYED. REPLACED EPSU AND BATTERY ASSY.SDR UALA2009032700906Control Cable · out of rigFOUND RUDDER CABLES OUT OF RIG. WITH RUDDER TRIM ZERO AND RIG PINS IN AFT CABLE QUADRANT AND MIXER OF FEEL AND CENTERING UNIT FREE FIT CANNOT INSERT RIG PIN IN FWD CABLE QUADRANT-CABLE TENSION REGULATOR. STARTED CABLE ADJUSTMENT. CABLE THAT NEEDS TO BE SHORSDR UALA2009032700903Wire · brokenEMERGENCY EXIT LIGHT TEST FAULTS L FWD EPSU WITH EXT LOAD FWD L FAULT. FOUND DOOR 1L SLIDE LIGHTS INOP. SUSPECT WIRE HARNESS BETWEEN SLIDE AND DOOR. REPAIRED BROKEN WIRE, SYSTEM TESTS OKAY.SDR UALA2009032600894Oven · defectiveDIVERTED TO DEN DUE TO CIRCUIT BREAKER FOR AFT GALLEY TRIPPING OFF. AFT GALLEY TRIPPING OFF. FLIGHT DIVERTED. FOUND ON INSPECTION BRACKET THAT HOLDS BUS PLUG 9025ML4 PULLED OUT FROM WALL. SUSPECT IT IS THE CAUSE OF TRIPPED BREAKER. REPAIRED BRACKET FOR OVENSDR UALA2009032700896Light · inoperativeSEAT MOUNTED EEL LIGHT OUT AT 1C, 5C, 11C. RELAMPED.SDR UALA2009032400876Hydraulic Line · looseNR 2 PYLON AFT HYD LINES THRU TRAILING EDGE WING SKIN ARE LOOSE, ATTACH FASTENERS WEARING INTO SKIN DOUBLER. WORK ACP ON SMB W-U M9110Q.SDR UALA2009032400877Fitting · looseNR 1 ENG HYD LINES AFT PYLON LWR WING SKIN BULKHEAD FITTING TO WING REAR SPAR IS LOOSE, WORKING AND WORN. WORK ACP ON SMB W-U R7483N.SDR UALA2009032300854Stringer · corrodedAFT PIT STR 43L BETWEEN FR56 & 57 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED STRINGER SECTION. FABRICATED & INSTALLED STRINGER SPLICE REPAIR.SDR UALA2009032000849Actuator · defectiveCABIN O2 MASK CONTAINER DOOR ABOVE SEAT 8ABC FAILED TO OPEN. LATCH ACTUATOR REPLACED AND OP CHECKED.SDR UALA2009032000850Actuator · defectiveCABIN O2 MASK CONTAINER DOOR ABOVE SEAT 9DEF FAILED TO OPEN. LATCH ACTUATOR REPLACED AND OP CHECKED.SDR UALA2009032000851Actuator · defectiveCABIN O2 MASK CONTAINER DOOR ABOVE SEAT 1AB FAILED TO OPEN. LATCH ACTUATOR REPLACED AND OP CHECKED.SDR UALA2009031800826Control Unit · malfunctionedLOST ALL THREE PHC'S, RTFL. REPLACED NR 1 LGCIU PER MM 32-31-71. TEST PASS. ACP'D TSM 32-31-00 PG 301, NO FURTHER FAULTS NOTED.
Back to IAE V2527-A5