SDR USAA920081492Bleed Valve · malfunctionedFLT 569 PHX-MCO -AIR TURNBACK- CAPTAIN RECEIVED NR2 ENG SYSTEM FAULT ON TAKEOFF AND EXCEEDED EGT LIMITS REACHING 641 DEGREES. THE ENG THRUST WAS SUBSEQUENTLY REDUCED BUT CREW WAS UNABLE TO INCREASE THRUST TO CLIMB OR CRUISE WITHOUT EXCEEDING EGT LIMITS. THE SDR 2008UALA04156Oxygen System · lowCREW OXYGEN ON UPPER ECAM. *S/D* SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA04143Panel · corrodedCORROSION AT CUTOUT FOR AFT LAV SERVICE PANEL ON LWR AFT FUSELAGE. MAJOR REPAIR ACCOMPLISHED: INSTALLED REPAIR DOUBLER.SDR 2008UALA04154Girt Lacing · inadequateLT AFT DOOR SLIDE GIRT LACING. *S/D* SLIDE GIRT LACING INADEQUATE. NEW SLIDE INSTALLED.SDR 2008UALA04157Oxygen Mask · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). *S/D* HARNESS IS CRACKED AND LEAKING. REPLACED F/O OXYGEN MASK, OPS CHECK OK.SDR 2008UALA04111Slide · low pressureDOOR 2R SLIDE PRESSURE LOW.
SDR 2008UALA04155Fire Loop · malfunctionedFIRE LOOP-A FAULT DISPLAYED ON UPPER ECAM SCREEN, ENG 2. REPLACED CORE LOOP ASSY. ACP FIRE TEST AND FDU TEST IN CFDS. OP CHKS NORMALSDR 2008UALA04123Oxygen System · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). CREW COMMENTS: MASKS DOES NOT TEST PROPERLY. *S/D* O2 BOX LEAKING AND TEST SWITCH IS STICKING. REPLACED 10RN3, 3RD OCCUPANT OXY BOX. OPS CHECKED NORMAL.SDR 2008UALA04124Oxygen Mask · leakingTHE 1ST OBS MASK, LEAKS. *S/D* HARNESS NOT INFLATING/LEAKING. REPLACED 1ST OBS MASK, OPS CHECKED OK.SDR YENA2008073Compressor · stalledFLT 1262, LGB-SMF, AIR RETURN TO LGB, ENG NR 1 COMPRESSOR STALL (ECAM) THRUST LEVERS AT CL DETENT LEVEL AT FL230 "BANG" AND YAW AND VIBRATION SAW ZERO EPR, THEN WENT BACK TO NORMAL. DID NOT SHUT DOWN IAW QRH 6-26. PERFORMED TSM 71-00-00-710-013-A, GVI, BLEEDSDR 2008UALA04078Light · inoperativeEMERGENCY ESCAPE LIGHT INOP AT 20C.SDR 2008UALA04044Outflow Valve · illuminatedBLOWER FAULT DISPLAYED. RTFL. PFR SHOWS SKIN AIR OUTLET VALVE 22HQ FAULT. REPLACED SKIN VALVE. OPS CHECKS GOODSDR 2008UALA04072Light · faultyON LAST 2 ENG SHUTDOWNS THE OVERWING EXIT LIGHTS ILLUMINATE WITH SWITCH IN OFF POSITION.SDR 2008UALA04073Slide · no testCABIN EMERGENCY SLIDE CHECK DID NOT PASS.SDR 2008UALA04053Warning Message · activatedLAVATORY SMOKE DETECTOR DISPLAYED ON UPPER ECAM.SDR 2008UALA04054Slide · lowDOOR 1L ESCAPE SLIDE PRESS IS NOT IN GREEN BAND.
SDR 2008UALA04055Battery · no testEMERGENCY LIGHT TEST FAILED.SDR 2008UALA04008Slide · shortedFAILED EMERGENCY LIGHT TEST. *S/D* INTERNAL SHORT/RESISTANCE IN SLIDE 1L. REPLACED SLIDE 1L. OPS CHECKED GOOD.SDR 2008UALA04029Fairing · looseLOOSE PANEL OR FAIRING ON LEFT MID WING AREA FLOATING APPROX 3 INCHES, REPORTED BY FLT ATTENDANTS AND PASSENGERS AND CONFIRMED BY FIRST OFFICER. NO ABNORMAL FLIGHT CHARACTERISTICS. RTFL. *S/D* REPLACED LEFT OUTBOARD RUB STRIP.SDR 2008UALA04041Bleed Valve · faultyNR 1 ENGINE EGT OVERTEMP. RTFL. *S/D* FAULT 10TH BLD VLV SOL-HC-EEC1, NR 1 ENGINE. REPLACED 10TH BLD VLV SOL-NR 1 ENGINE. ACCOMPLISHED HIGH POWER RUNS, ALL CHECKED NORMAL.SDR 2008UALA03994Battery Pack · inoperativeEMERGENCY LIGHTS FAILED TEST PER 3SVC. *S/D* EPSU FAILURE. REPLACED EPSU R & R BATTERY. EMERGENCY LIGHTS TEST OK.SDR 2008UALA03987Battery · weakBATTERY EMERGENCY R DISPLAYED AFTER CHECK OF CABIN EMERGENCY LIGHT TEST. *S/D* WEAK BATTERY. REPLACED BATTERY PER MM. TEST OK.SDR 2008UALA03988Fire Bottle · out of toleranceLAV -A FIRE EXTINGUISHER SYSTEM - FOUND 1L LAV FIRE EXTINGUISHER IN THE RED. *S/D* REPLACED FWD LAV -A EXTINGUISHER.SDR 2008UALA04009Warning Light · illuminatedTHE "SLIDE PRESS LOW. CHECK SLIDE PRESS EMER R, EMER L" DISPLAYED ON PTP PANEL AFTER INSTALLATION OF AFT LEFT SIDE EMERGENCY OVERWING EXIT. *S/D* RESET AIRCRAFT PWR MSG DISAPPEARED. OPS TEST EMERGENCY LIGHTS NORMAL.SDR 2008UALA04010Connector · unsecureEPSU BATTERY FWD L DISPLAYED AFTER EMERGENCY LIGHT TEST PER 3 SVC. *S/D* CONNECTOR LOOSE. RE-SEATED MATING CONNECTOR FOR LEFT FWD BATT PACK, NORMAL OPERATION RESTORED, OPS CHECKS OKAY.SDR 2008UALA03963Oxygen Mask · faultyCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. *S/D* SHORT IN BOX OR MASK (UNABLE TO DETEMERMINE). REMOVED AND REPLACED CAPTS O2 BOX AND MASK ALONG WITH AMU- OPS CHECK GOOD, LEAK CHECK GOOD.SDR 2008UALA03921Skin · damagedRT WING O/B FLAP HAS A REPAIR OF 8 INCHES BY 15 INCHES ON LOWER TRAILING EDGE. THE TRAILING EDGE OF REPAIR IS SEPARATING FROM FLAP. *S/D* REPAIRED FLAP.SDR 2008UALA03922Slide · faultyTEST OF EMERGENCY LIGHT SYSTEM SHOWS AFT EXTERNAL LOAD FAULT. *S/D* INTERNAL SHORT/HIGH RESISTANCE IN SLIDE 2L. REMOVED AND REPLACED 2R DOOR SLIDE, OPS TEST ARE NORMAL.SDR 2008UALA03927Power Supply · faultyEPSU UNIT AFT L MESSAGE DISPLAYED AFTER EMERGENCY LIGHT CHECK. *S/D* EPSU FAILED. REPLACED EPSU, OPS CHECKED NORMAL.SDR 2008UALA03914Microphone · faultyTHE O2 WORKS ON ALL 3 MASKS, MICROPHONE FOR ALL 3 MASKS ARE INOP. *S/D* AFTER FURTHER ANALYSIS, IT HAS BEEN DETERMINED THIS IS NOT AN SDR REPORTABLE EVENT. ALL FLT DECK MASKS OPS CK OK. NO EVIDENCE THAT THERE EVER WAS AN ISSUE WITH THE SYSTEM OF THE A/C.
SDR 2008UALA03907Bearing · wornDIVERTED TO JAX DUE TO AN EXTREME VIBRATION. REPLACED ALL RUDDER HINGE BEARINGS AND ALL ELEV HINGE BEARINGS. TEST FLIGHT NORMAL, NO VIBRATION NOTED.SDR 2008UALA03891Pan · damagedEXCESSIVE MATERIAL REMOVED FROM DOOR 2L DOOR SILL PAN AFT END AT 2EA NUT PLATE HOLES. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED DAMAGE MATERIAL, FABRICATED REPAIR PARTS.
SDR 2008UALA03890Frame · dentedFUSELAGE DENT FRAME 30 STRINGER 25R. *S/D* ACCOMPLISHED MAJOR REPAIR AT LCQ. INSTALLED DOUBLER REPAIR PER SRM 53-21-11.SDR 2008UALA03895Shear Plate · corrodedFOUND RT SHEAR PLATE CORRODED BETWEEN FRAME 69 AND 70 REF EQ3700. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED SHEAR PLATE, INSTALLED SAME NEW.SDR 2008UALA03897Beam · corrodedFOUND BEAM NR 200 CORRODED REF EQ3700. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM, PREPPED AND RE-INSTALLED.SDR 2008UALA03898Beam · corrodedFOUND BEAM 205 CORRODED REF EQ3700. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM, PREPPED AND RE-INSTALLED.SDR 2008UALA03899Beam · corrodedFOUND BEAM NR 175 CORRODED REF EQ3700 B. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM, PREPPED AND RE-INSTALLED.SDR 2008UALA03900Beam · corrodedFOUND BEAM 210 CORRODED REF EQ3700. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM, PREPPED AND RE-INSTALLED.SDR 2008UALA03901Beam · corrodedFOUND BEAM 230 CORRODED REF EQ3700. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM, PREPPED AND RE-INSTALLED.SDR 2008UALA03902Floorbeam · corrodedFOUND FLOORBEAM 235 CORRODED REF EQ3700. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM, ON WORKBENCH. INSTALLED SPLICE ON BEAM AND PAINTED. INSTALLED BEAM.SDR 2008UALA03903Pan · damagedEXCESSIVE MATERIAL REMOVED FROM DOOR 2L DOOR SILL PAN AFT END AT 2EA NUT PLATE HOLES REF SMC 28. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED DAMAGE MATERIAL, FABRICATED REPAIR PARTS, AND INSTALLED.SDR 2008UALA03911Skin · dentedFOUND 2 DENTS AT SECTION FR23 AT FLOOR LEVEL ON LEFT SIDE OF AIRCRAFT. *S/D* ACCOMPLISHED MAJOR REPAIR AT IAD. CLEANED AREAS, CHECKED FOR CRACKS, NONE FOUND. TREATED AREAS, PRIMED AREAS, PAINTED AREAS. OK PER SRM 53-00-11.SDR 2008UALA03912Frame · dentedFUSELAGE DENT FRAME 30 STRINGER 25R. *S/D* ACCOMPLISHED MAJOR REPAIR AT LCQ. INSTALLED DOUBLER REPAIR PER SRM 53-21-11 FIG 215.SDR 2008UALA03873Frame · corrodedR2 DOOR SILL CORROSION AT FASTENER HOLE FRAME 66. *S/D* ACCOMPLISHED MAJOR REPAIR AT LCQ. INSTALLED REPAIR PER SRM 53-41-14.SDR 2008UALA03853Switch · failedLEFT AFT SLIDE INDICATION INOP ON DOOR-OXY SYSTEM ECAM PAGE - DOOR-OXY -SLIDE ARMS BUT INDICATION INOP. *S/D* SLIDE DOOR ARMING PROX SWITCH FAILED. REPLACED PROX SWITCH AT DOOR 2L. ALL INDICATIONS ARE NORMAL.SDR 2008UALA03863Oxygen Bottle · lowCOCKPIT OXYGEN BOTTLE -LOW. *S/D* SERVICED CREW O2, OPS CHECKED NORMALLY.
SDR 2008UALA03785Bulb · inoperativeDURING OP-TEST OF FLOOR EMERGENCY ESCAPE PATH SYSTEM, ONE INCANDESCENT LIGHT INOP AT SEAT 9C. FOUND BULB OUT. REPLACED LAMP AT ROW 9C.SDR 2008UALA03791Feeder Cable · burnedFOUND BURNED IDG FEEDER CABLE AT JUNCTION BOX IN PYLON. NR 1 ENG. REPLACED FEEDER CABLE HARNESS, ALL SYS CHECKS PERFORMED NORMALLY.SDR 2008UALA03792Smoke Detector · faultyLAVATORY DETECTOR FAULT DISPLAYED ON UPPER ECAM SCREEN. FOUND SMOKE DETECTOR MALFUNCTIONED. REPLACED SMOKE DETECTOR, SYS OPS CHECKED NORMALLY.SDR 2008UALA03719Light · inoperativeEMERGENCY PATH LIGHTS AT ROWS 18, 14 & 17 INOP. *S/D* REPLACED EMERGENCY PATH LIGHTS, OK FOR SERVICE.