SDR 2008UALA03731Oxygen System · lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 AND NO LEAKS NOTED AT TIME.SDR 2008UALA03718Light · brokenSEAT 25ABC ESCAPE PATH LIGHT BROKEN. UNKNOWN DAMAGE. REPLACED LIGHT ASSY, OPS CHECKED NORMALLY.SDR 2008UALA03666Smoke Detector · inoperativeLAV SMOKE DETECTOR INOPERATIVE. REPLACED LAV F SMOKE DETECTOR R EF MM 26-17-15, BITE TESTED GOOD.SDR 2008UALA03620Wire · shortedTHREE SERVICE EMERGENCY LIGHT TEST FAILS. FAULT MSG EXT LOADS AFT L DISPLAYED. *S/D* INTERNAL SHORT IN DOOR SLIDE 2L. REPLACED 2L DOOR SLIDE.SDR 2008UALA03582Unknown · odorF/A REPORTS VERY STRONG ODOR POSSIBLE CHEMICAL.
SDR 2008UALA03592Aspirator · damagedCROSS THREADED ASPIRATOR FITTING. IMPROPER INSTALLATION. REPLACED ASPIRATOR.SDR 2008UALA03593Aspirator · damagedLEAKING ASPIRATOR FLAPPER VALVES. DAMAGE DUE TO EXCESSIVE USE. REPLACED ASPIRATOR, OPS OK.SDR UALA2008111303582Unknown · odorF/A REPORTS VERY STRONG ODOR POSSIBLE CHEMICAL. STEAM CLEANED TWICE WITH CITRA SAFE, RINSED WITH WATER AND DRIED FWD OF BILGE. FINAL FIX?SDR 2008UALA03503Transducer · failedNR 1 ENG BLEED AIR TRIPPED OFF AND WOULD NOT RESET. RTFL. *S/D* BMC1 FAULTED 8HA1, AIR REGULATOR TRANSDUCER. REPLACED AIR REGULATOR TRANSDUCER, 8HA1, OPS CHECKED NORMALLY.SDR 2008UALA03522Charger · faultyEMERG LIGHT TEST FAILED AFTER SLIDE CHANGE..."L EMERG BATT" FAULT. WEAK BATTERY, REPLACED LEFT OVERWING BATTERY & CHARGER. TEST OK.SDR 2008UALA03525Connector · disconnectedEMERGENCY FLOOR EXIT LIGHTS INOP AT FWD CABIN BULKHEAD AND ROW 9. ALL OTHER LIGHTS OPERABLE. FOUND CONNECTOR UNDER SEAT DISCONNECTED. RE-CONNECTED UNDER SEAT CONNECTION, ALL LIGHTS OPERATE.SDR 2008UALA03498Pump · failedYELLOW HYDRAULIC SYSTEM FAILURE. FLIGHT DIVERTED. NR 2 EDP FAILURE. REPLACED NR 2 ENG HYD PUMP, SERVICED HYD TO FULL, LEAKS CHECKED GOOD.SDR 2008UALA03467Hydraulic Line · leakingYELLOW SYSTEM PRESSURE & QTY LOSS IN CRUISE. FLIGHT DIVERTED. LEAK ON HYD LINE ON NR 2 ENGINE. FOUND HYDRAULIC LINE ON ENGINE LEAKING. REPLACED LINE. ALSO, REPLACED NR 2 ENGINE HYDRAULIC PUMP, CHECKED HYDRAULIC CONTROL UNIT FILTER, CASE DRAIN FILTRT AND HSDR 2008UALA03473Battery · faultyCIDS BIT BATTERY FWD L. EPSU FAILURE. REPLACED EPSU.SDR 2008UALA03499Computer · failedELEVATOR - AILERON COMPUTER (ELAC) 2 INOP. CHANNEL 4 CPU FAILURE (INTERNAL) ON ELAC 2. REPLACED ELAC 2, OPS CHECKED GOOD.SDR 2008UALA03460Sign · inadequateEMERGENCY LIGHT WILL NOT PASS TEST AT 1L. FOUND EXIT SIGN AT 1R OVER DOOR VERY DIM. REPLACED SIGN ASSY, OPS CHECKED NORMAL.SDR 2008UALA03470Transmitter · faultyNR 2 ENG OIL QUANTITY LOW INDICATION, RTFL. INCORRECT INDICATION ISSUE. REPLACED NR 2 ENGINE OIL QUANTITY TRANSMITTER, ACCOMPLISHED ENGINE RUN. NO LEAKS NOTED.SDR 2008UALA03484Skin · dentedDENT IN RVSM AREA 9.25" FROM STATIC PORT, AREA R6 IN FORWARD LOWER LEFT OF STATIC PORT. DENT IS .010 " DEEP, .25"WIDE X .375" TALL. -OK - :PER SRM 53-00-11 DIAGRAM 10 2, WITHIN AERODYNAMIC RVSM REQUIREMENT. CF9019 CREATED FOR PERMANENT REPAIR FOR NEARNESS SDR 2008UALA03434Power Supply · faultyMESSAGE "ATA 33-51-38 INT LOADS AFT L" SHOWS AFTER THE TEST. POWER SUPPLY FAILURE. REPLACED POWER SUPPLY AND BATTERY. OPS CHECKED NORMALLY.SDR 2008UALA03435Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: O2 IS 1480 PSI. SERVICED CREW O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA03436Slide · crackedRIGHT OVERWING EVACUATION SLIDE IS CRACKED AT AFT SIDE. COMPOSITE CRACK. REPLACED SLIDE.SDR 2008UALA03421Light · failedEMERGENCY LIGHT TEST ON CIDS PANEL FAILED IT'S TEST. FAULTED THE UNIT.SDR 2008UALA03425Battery · failedLEFT FWD EMERGENCY LIGHT BATTERY FAILED EMERGENCY LIGHT TEST AND SELF TEST. REPLACED FWD LEFT EMERGENCY LIGHT BATTERY. TESTS GOOD.SDR 2008UALA03426Unknown · odorFLT ATTENDANTS REPORT ELECTRICAL SMELL FROM AFT GALLEY. SMELL DISSIPATED WHEN LIGHTS, OVEN, CHILLERS AND C-M'S TURNED OFF.SDR 2008UALA03423Cable · brokenR2 DOOR ESCAPE SLIDE CABLE IS BROKEN.SDR 2008UALA03427Structure · damagedTHE 1L DOOR DAMAGED DUE TO AIRSTAIR CONTACTING DOOR BOTTOM.SDR 2008UALA03458Unknown · unknownALL 3 PITOT PROBES INOP AFTER TAKEOFF. ALL RESET ATTEMPTS NO HELP, LGCIU'S, FWC'S, SDAC'S, AND CYCLE OF THE GEAR NO HELP. SUSPECT AIR GROUND MODE PROBLEM. REPLACED LGCIU 2, ALL SYSTEMS WERE CHECKED AND FOUND TO FUNCTIONING NORMALLY. NO REPEATS AFTER THIS ISDR 2008UALA03378Light · inoperativeEMERGENCY LIGHT SYSTEM FAILED TEST AFTER SLIDE REPLACEMENT LT EMERGENCY BATTERY.SDR 2008UALA03377Skin · damagedRAMP REPORTS FUSELAGE ABRASION TWO FEET AFT AND ABOVE DOOR 1L.SDR 2008UALA03422Cylinder · looseR2 DOOR DAMPER EMERGENCY OPERATIONS CYLINDER PERCUSSION LEVER GUIDE LOOSE.SDR 2008UALA03343Sensor · failedPRESSURIZATION PROBLEM, RTFL. PACK 2 OVERHEATED AND WOULD NOT RESET FULLY, AND PACK 1 WAS ON DEFFERAL. RTFL, UNABLE TO PRESSURIZE AC. REPLACED ACM DISCHARGE TEMP SENSOR NR 2 PACK, OPS CHECK NORMAL.SDR 2008UALA03374Slide · low pressureDOOR 1R SLIDE PRESSURE IS LOW.SDR 2008UALA03375Sill · corrodedL2 DOOR SILL AT C68 IS CORRODED.SDR 2008UALA03376O2 Generator · misinstalledL2 DOOR MASK FOUND GENERATOR PINNED WITH STREAMER AND D LAV MASK WAS TUCKED UNDER STRAP IN BOX.SDR 2008UALA03424Oxygen System · low pressureOXYGEN HIGH PRESSURE INDICATION AMBER ON DOOR-OXY SYSTEM ECAM PAGE - DOOR-OXY.SDR 2008UALA03344Wire · shortedEMERGENCY LIGHTS BITE TEST FAILS 3 RED SEAT PATHWAY LIGHTS AND LOWER EMERGENCY EXIT LIGHTED SIGN ON OPPOSITE SIDE DO NOT LIGHT UP. EPSU ON RT MID CABIN BENEATH EMERGENCY EXIT INDICATES UNIT FAULT. FOUND WIRE SHORTED UNDER SEAT 9ABC. WIRE STRANDS NOT DAMAGEDSDR 2008UALA03345Light · shortedF/A SMELLED BURNING AT FWD DOOR 1L AND PAX LIGHTS FLASHING ON AND OFF. FWD ENTRY LIGHT BULB SHORTING. RELAMPED FWD ENTRY LIGHT. LIGHT SOCKETS OKAY. NO ARCING NOTED. NO ABNORMAL SMELLS NOTED UPON ARRIVAL.SDR 2008UALA03313Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: SYSTEM READS 0. SAMC TEXT: PRESSURE IS LESS THAN 10 PSI. PURGE SYSTEM FIRST AND THEN SERVICE TO FULL.SDR 2008UALA03314Power Supply · unknownEPSU INT LOAD FWD L FOUND ON 3SVC CHECK.SDR 2008UALA03244Smoke Warning · activatedAVIONICS SMOKE/ECAM. RTFL.SDR 2008UALA03276Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESS PRIOR TO SERVICING.SDR 2008UALA03289Unknown · vibrationGEAR VIBRATION AFTER LIFT OFF UNTIL GEAR HANDLED RAISED.SDR 2008UALA03277Light · failedTHE 3 SVC EMERGENCY LIGHT TEST FAILS, "EXT LOADS L AFT".SDR 2008UALA03223O-Ring · leakingNOSE GEAR DOORS WOULD NOT CLOSE. RTFL. *S/D* INTERNAL STRUT LEAK- O-RING ISSUE. NLG STRUT REPACKED, SERVICED. GEAR SWINGS WERE NORMAL.SDR 2008UALA03200Hose · brokenHOSE BROKE DURING INFLATION. HOSE DID NOT SWIVEL DURING INFLATION CAUSING HOSE TO BREAK. REPLACED HOSE.SDR 2008UALA03181Solenoid · failedCABIN OXYGEN FAILED AT 3 DEF, 6 ABC, 8 DEF, 10 DEF, 10 ABC, 13 DEF, 19 DEF, 23 DEF, AND AFT ATTENNDANT SEAT. LATCH SOLENOIDS FAULTY AT EACH LOCATION. REPLACED LATCH SOLENOIDS AND OP CHECKED GOOD.SDR 2008UALA03195Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. RESERVICE 1360 PSI. SERVICED 1740 PSI., NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA03177Microphone · shortedCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. CREW COMMENTS: MIC IS INTERMITTANT. SHORT IN MIC/MASK. REPLACED CAPT O2 MASK ASSY.SDR 2008UALA03182Bottle · leakingNR 2R DOOR ASSIST BOTTLE WILL NOT HOLD AIR. FOUND BOTTLE EMPTY. FOUND LEAKING AT O-RING FOR SCHRADER VALVE. REPLACED SCHRADRER VALVE AND PACKINGS, RESERVICED BOTTLE.SDR 2008UALA03196Computer · faultyELAC 1 FAULT DISPLAYED ON UPPER ECAM SCREEN, F-CTL. ELAC NR 1 FAULTY. REPLACED ELAC-1 - OPS TEST OK. LAND CAT III CAPABILITY TEST OK.