IAE V2527-A5
Service difficulty reports · 8,009
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201606219004Fillercap · leakingAIRCRAFT WAS GROUNDED. WHEN EXTERNAL AIR WAS REMOVED AND APU BLEED AND PACK 1+2 COOLING A/C AT GATE, A STRONG DIRTY SOX ODOR WAS OVERWHELMING. MAINTENANCE DETERMINED THAT THE SOURCE OF THE ODOR WAS THE APU AND WAS PLACED ON MEL. MAINTENANCE FOUND EVIDENCE OSDR CALA2016062295467Shear Tie · corrodedFWD PIT SHEAR TIE AT FRAME 31 BETWEEN DTR 43R-43L HAS CORROSION. R & R CORRODED SHEAR TIE ON FWD CARGO FRAME 31 STR 43R-43L IAW SRM 51-42-11.SDR CALA2016062295469Cleat · corrodedFWD PIT AT FRAME 29, STR 42L-STR 43L CLEAT HAS CORROSION. R & R CORRODED CLEAT ON FWD CARGO FRAME 29, STR 42L-43L, SRM 51-42-11.SDR CALA2016081195628Connector · looseEMERGENCY LIGHT TEST FAILED. MESSAGE EPSU EXT LOAD FWD L. RESEATED EPSU CONNECTOR, REPLACED BATTERY.SDR CALA2016062295463Power Supply · inoperativeON 2 SERVICE CHECKS, EMERGENCY LIGHTS TEST FAIL WITH FOLLOWING MSG, EXT LOADS EMERGENCY RT BATTERY, EMERGENCY RT AND UNIT EMERGENCY LT. REPLACED DOOR 2L LIGHT POWER SUPPLY AND BATTERY OPS CHECK GOOD.SDR CALA2016062295464Power Supply · inoperativeWITH EMERGENCY LIGHT SWITCH IN ARMED MODE AND LOSS OF ACFT POWER, EMERGENCY LIGHTS DO NOT COME ON IN THE CABIN AND OVERWING. REPLACED EMERGENCY POWER SUPPLY AND BATTERY AT DOOR 1L. OPS CK GOOD.SDR CALA2016081195622Light · malfunctionedNUMEROUS CIDS PA LIGHTS INTERMITTENT. CABIN LIGHTS TO FULL BRIGHT ON T/O. BITE CHECK OF CIDS SYSTEM AND OPS CHECKS OF LIGHTS ALL CHECK GOOD. OK TO CONT.SDR CALA2016061795460Power Supply · inoperativeEMERGENCY BATTERY CAPACITY TEST FAILED DUE TO LT BATTERY MSG 33-51-38. REPLACED EEL POWER SUPPLY AT DR1L, 10WL. OPS CK GOOD.SDR CALA2016081195637Battery Pack · no testEMERG LIGHTS MESSAGE. EXT LOADS EMER R, BATT EMER R, EMER L REPLACED RIGHT OVERWING EPSU & BATTERYSDR CALA2016081195624Battery Pack · no testEPSU BATTERY EMER L SHOWN DURING TEST. REPLACED LEFT EMERGENCY EPSU BATTERY. OPS CHK GOODSDR CALA2016081195632Power Supply · no testTEST FAIL MESSAGE, EMERGENCY LIGHT. REPLACED THE BATTERY AND EPSU, OPS TESTED OKSDR CALA2016081195633Light · malfunctionedEXIT LIGHT AT L1 DOOR, OPERATES INTERMITTENTLY. OPS TEST OF THE EMERGENCY LIGHTS CHECKED OK IAW AMM.SDR CALA2016061795462Director · faultyON CLIMB, CONTINUOUS EVAC HORN, AND CI DS 1 & 2 FAULTS ON ECAM. REPLACED 1 & 2 CIDS DIRECTORS REF AMM 23-73-34-400, NO FAULTS AT THIS TIME.SDR CALA2016081195623Battery Pack · no testEPSU UNIT FWD L SHOWN DURING TEST. REPLACED FWD EPSU BATTERY, OPS CHECKED GOODSDR CALA2016081195630Power Supply · no test13WL EPSU FAILED LIGHT CHECK. REPLACED THE EPSU, OPS CHECKED GOOD.SDR CALA2016081195631Light · malfunctionedEMERGENCY EXIT LIGHTS WILL NOT EXTENGUISH. CYCLED POWER, LIGHT OPS NORMALSDR CALA2016061395442Warning Message · false activationBATTERY EMERGENCY LT MSG DURING EMEGENCY LIGHT TEST IAW NR 2 SERVICE CHECK. POWER UP ACFT AND ACP TASK 33-51-00-710-007-B. OPS TEST OF EMERGENCY LIGHTING BY LIGHT EMEGENCY RG PUSHBUTTON SWITCH. TEST OK.SDR YENA20160609547Engine · failedEMERGENCY DECLARED. ACFT LANDED WITH NO INCIDENTS. ENGINE NR 1 STALLED DURING CRUISE FOLLOWED BY HIGH EGT TEMPERATURE. ENGINE WAS SHUTDOWN FOR THE REMAINDER OF FLIGHT. STALL WAS AUDIBLE AND EGT WAS IN RED BAND. ENGINE OVERTEMP AT 784. ENGINE WAS R & R IASDR CALA2016061395447Stringer · corrodedAFT CARGO COMPARTMENT FRAME 54-59, STR 43L HAS CORROSION. REMOVED AND INSTALLED STR 43L FROM FRAME 54-FRAME 60 INSTALLED FACTORY SPLICE AND 2 EA CLENTS.SDR CALA2016081195625Battery Pack · no testEMERGENCY LIGHT SYSTEM TEST FAILED. REPLACED EPSU AND BATTERY AT DOOR 1L, OPS CHECKED GOODSDR CALA2016081195627Warning Message · false activationCIDS EMERGENCY LIGHT TEST. MESSAGE EPSU BATTERY EMERGENCY LIGHT R. RESET, MESSAGE CLEARED, OPS CHECKED GOOD.SDR CALA2016060695431Unknown · smokeELECTRIC SMOKE SMELL IN COCKPIT AFTER TAKEOFF, VISIBLE SMOKE IN CABIN OVERHEAD. AIR RETURN. HIGH POWER RUN ACCOMPLISHED IAW TSM 71-00-00-810-801. NO ELEC SMOKE SMELL NOTED ON HIGH POWER RUNS.SDR CALA2016060695432Stringer · corrodedAFT PIT BULK STRINGER 31R, BELOW OUTFLOW VLV CORRODED. R & R THE AFT PIT BULK STRINGER 31R IAW SRM 51-72-11.SDR CALA2016081195629Light · malfunctionedDURING TAXI, EMERGENCY CALL LIGHTS AND CHIMES WENT OFF THREE TIMES. UNABLE TO DUPLICATE FAULT, RESET CIDS AS PRECAUTIONSDR GTIA2016060301467Seal · leakingCABIN AND COCKPIT FUMES WERE SMELLED IN ACFT ON FINAL APPROACH, FUMES SMELLED LIKE DIRTY SOCKS. FOUND OIL IN NR 1 AND NR 2 ENGINE DE-OILER TUBES. R & R NR 1 AND NR 2 DEOILER SEALS IAW AMM 72-60-31 LOCK AND LEAK CHECKS GOOD. TESTED FOR OIL ODOR WITH AIR SENSESDR CALA2016060195428Battery Pack · no testEMERGENCY BATTERY TEST FAILED. REPLACED THE BATTERY PACK. OPS CHECKED GOOD WITH NO FAULTS NOTED.SDR CALA2016060195426Wire · damagedDURING CLIMB, NR 1 ENGINE AMBER EGT INDICATION ILLUMINATED. LOOKED AT EGT & NOTICED IT WAS OVER 600 DEG FOR 5 SECS, BUT COULD NOT GIVE AN EXACT TEMP TO MX. R & R FOUR WIRES THAT WERE FOUND DAMAGED THAT GOES FROM HPC STAGE SOLENOID TO EEC. PERFORMED POWER RSDR CALA2016060195427Keelbeam · damagedKEEL BEAM HAS SEVERAL OUT OF ROUND HOLES. REPAIRED ALL HOLES IAW ECRA 5330-05712.SDR CALA2016060195425Flap · unsecureEMERGENCY EXIT DOOR SHOWS UNLOCKED INFLIGHT. SECURED DOOR PANEL FLAP ON LT FWD OVERWING DOOR EXIT INTERIOR HANDLE IAW 25-62-00 & 52-21-00 DOOR ARM INDICATION. OPERATIONS NORMAL.SDR CALA2016060195424Stringer · crackedLEFT FUSELAGE FRAME 35, STRINGER 30 IS CRACKED. REPAIRED IAW ECRA 5330-05705.SDR CALA2016052395412Window · crackedCAPTAINS SIDE INNER PANE WINDOW SHATTERED ON CLIMB OUT. R & R WINDOW HEAT CONTROLLER. R & R CAPTAINS WINDOW ASSEMBLY.SDR CALA2016052395407Battery Pack · dischargedCIDS EMER LIGHT TEST FAILS FOR TO MSG'S, BATTERY EMER RT & BATTERY LT. REMOVED & REINSTALL BOTH BATTERY PACKS. FAULT CLEARED & TESTED OKAY.SDR CALA2016052395405Skin · gougedEXTERIOR FUSELAGE SKIN IS GOUGED AT 3.5 INCHES BELOW STRINGER 31L & ON FRAME 34 OUT OF LIMITS. CUT OUT DAMAGED SKIN FABRICATED & INSTALLED DOUBLER & FILLER.SDR CALA2016052395406Power Supply · inoperativeCABIN EMER LIGHTS TEST FAILED, EPSU BATTERY FWD LT. REPLACED FWD LT POWER SUPPLY BATTERY IAW AMM 33-51-38-000-002-A. TESTED OK.SDR CALA2016052095378Battery · dischargedTHREE EACH EMER EXIT LIGHTS IN CABIN INOPERATIVE. ONE AT LT AFT EXIT HATCH DEDO WALL LIGHT. ONE AT RT FWD EXIT HATCH DEDO WALL LIGHT & ONE AISLE LIGHT AT SEAT 22C EPSU BATTERY EMER LT REPLACED 12WL BATTERY. EPSU TESTED OK.SDR CALA2016052395404Pin · backed outTHREE EACH EMER EXIT LIGHTS IN CABIN INOPERATIVE. ONE AT LT AFT EXIT HATCH DEDO WALL LIGHT. ONE AT RT FWD EXIT HATCH DEDO WALL LIGHT & ONE AISLE LIGHT AT SEAT 22C. SYS TESTED EMER LIGHT, GOT EPSU BATTERY EMER LT REPLACED 12WL BATTERY. EPSU TESTED OK. NOW TSDR CALA2016051895373Warning System · false activationSMOKE FOR AFT CARGO COMPARTMENT WARNING WITH FIRE BOTTLE DISCHARGE. ACFT DIVERTED DUE TO WEATHER. PERFORMED OPERATIONS TEST OF CARGO FIRE EXTINGUISHER SYS, CHECKED ALL NORMAL IAW AMM 26-23-00. R & R FIRE BOTTLE.SDR CALA2016051895374Sensor · faultyLANDING GEAR DISAGREE DISPLAYED ON UPPER ECAM. REPLACED NGL SENSOR 25GA. ACCOMPLISHED BITE TEST IAW AMM 32-69-00.SDR CALA2016051895364Oxygen Mask · deployedCREW REPORT SEAT 31DEF O2 MASK DEPLOYED. MASK REPACKED & LATCH CHECKED IAW AMM 35-21-43. PERFORM MANUAL MASK RELEASE OPERATIONAL CHECK IAW AMM 35-23-00-710-001, CHECKED SATISFACTORY.SDR CALA2016051295350Power Supply · faultyEMERGENCY POWER SUPPLY UNIT FWD LT MSG ON PTP PANEL AT DOOR 1L. REPLACED EMER POWER SUPPLY UNIT 10WL IAW MM 33-51-38-401. OPERATIONS NORMAL.SDR CALA2016051295352Hydraulic Line · leakingAIR RETURN DUE TO LOSS OF YELLOW SYS HYDS. EDP NR 2 OPERATED DRY DURING FLUID LOSS OF YELLOW SYS. FOUND NR 2 ENG HYD PUMP PRESS LINE & CHECK VLV O RING LEAKING. PUMP FOUND TO HAVE OPERATED WITHIN LIMITS, NO FURTHER ACTIONS REQUIRED.SDR CALA2016050695348Frame · damagedFRAME 15, AFT SIDE WEB DAMAGED, APPROX AT STRINGER 2L. REPAIRED FRAME 15 TD-P1-52-19995-2016 & SRM 51 -42-11, 51-21-11 & 51-75-12.SDR CALA2016050695349Door Sill · corrodedAFT CABIN WET AREA, CORROSION AT LT 2 DOOR THRESHOLD SILL, AT FRAME 66. REMOVED DAMAGED PARTS & INSTALLED REPAIRED DOUBLER & GIRT BAR FITTING PLATE.SDR CALA2016050695346Skin · corrodedFOUND SIGNIFICANT EXFOLIATION ON FUSELAGE SKIN AT LAVATORY TANK VENT PORT, BETWEEN FRAME 69 & 70, BETWEEN STRINGER 31 & 32 RT. INSTALLED PERMANENT REPAIR IAW SRM 53-41-11.SDR CALA2016050495331Battery · dischargedAFTER REPLACEMENT OF 1R SLIDE, FOUND SEVERAL LIGHTS OUT FROM CTR BATTERY PACK WITH A-C POWER OFF. REPLACED CTR BATTERY PACK WITH SERVICEABLE UNIT. TESTED SUCCESSFUL.SDR AALA201605029014Apu · leakingAIRCRAFT WAS GNDED. DIRTY SOCK SMELL IN DESCENT OUT OF FL 200. FOUND THE APU LEAKING OIL & REPLACED IT IAW TASK CARD 26L31049005.SDR CALA2016050495327Shear Tie · corrodedFORWARD CARGO BAY SHEAR TIE AT FRAME 33, BETWEEN STRINGER 44 - 43LT, HAS CORROSION. R & R SHEAR TIE AT FRAME 33, BETWEEN STRINGER 44 - 43LT.SDR CALA2016050495323Door Sill · corrodedL2 DOOR AFT GIRT BAR FITTING HAS CORROSION LEACHING OUT FROM UNDER ADJUSTMENT PLATE & SCUPPER. REMOVED CORROSION FROM L2 DOOR SILL FRAME 68, FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR & INSTALLED. INSTALLED GASKET & STEEL PLATE ASSEMBLY ECRA 5100-02464.SDR CALA2016050495322Stringer · corrodedAFT CARGO BAY, STRINGER 43L HAS CORROSION IN 3 PLACES, APPROX 3 INCHES AFT FRAME 56, 9 INCHES FWD FRAME 57 & 3 INCHES AFT FRAME 59. R & R CARGO BAY STRINGER 43L.SDR CALA2016050495338Fitting · corrodedL2 DOOR FWD GIRT BAR FITTING INBD AFT NUTPLATE CORRODED. CORROSION ON L2 DOOR SILL FWD GIRT BAR FITTING, 2 EACH NUTPLATE HOLES FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR & INSTALLED ON NON-ROUTINE 38574.
Back to IAE V2527-A5