AIR RETURN DUE TO LOSS OF YELLOW SYS HYDS. EDP NR 2 OPERATED DRY DURING FLUID LOSS OF YELLOW SYS. FOUND NR 2 ENG HYD PUMP PRESS LINE & CHECK VLV O RING LEAKING. PUMP FOUND TO HAVE OPERATED WITHIN LIMITS, NO FURTHER ACTIONS REQUIRED.