IAE V2527-A5
Service difficulty reports · 8,011
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01680Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW, RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: O2 PRESS 1370 PSI. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2 TO FULL. NO LEAKS WERE FOUND.SDR 2008UALA01679Oxygen System · reads lowCREW O2 IS LOW (1430PSI) FOUND ON 3SVC. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2, LEAK CHECK OK.SDR 2008UALA01682Mask · leakingFIRST OBSERVERS O2 MASK IS LEAKING. SUPPLEMENTAL DATA UPDATE CAUSE, MASK LEAKING AT PORT. REPLACED F OBS MASK. OPS CHECKED OK.SDR 2008UALA01595Connector · dirtyFLIGHT DIVERTED DUE TO AFT CARGO DOOR INDICATION PROBLEM. POSSIBLE DIRTY CONNECTOR. CLEANED AND SECURED AFT CARGO INDICATION CONNECTOR, ALL FAULTS CLEARED AND NO FURTHER DEFECTS NOTED, OPENED & CLOSED DOOR SEVERAL TIMES WITH NO DEFECTS, AFT CARGO DOOR WARNINSDR 2008UALA01617Slide · faultyWHILE ACCOMPLISHING TEST OF EMERGENCY LIGHTING SYSTEM, HAVING FAULT MESSAGE EPSU EXT LOAD AFT LEFT. INTERNAL ELECTRICAL FAILURE IN SLIDE 2L. REPLACED SLIDE 2L WITH BORROWED PART.SDR 2008UALA01608Lamp · inoperativeSEAT MOUNTED AISLE EMERGENCY FLOOD LIGHT AT SEAT 22C INOP. LAMP INOP. RELAMPED, OPS CHECKED NORMAL.SDR 2008UALA01609Thrust Reverser · damagedNR 1 ENGINE LT REVERSER DAMAGED. UNKNOWN A/C DAMAGE. PERFORMED PERMANENT REPAIR ON REVERSER HALF (COMPOSITE).SDR 2008UALA01570Cover · missingSEAT 15C IS MISSING EMERGENCY LIGHT COVER. REPLACED MISSING COVER.SDR 2008UALA01571Cover · missingSEAT 23C IS MISSING EMERGENCY LIGHT COVER. REPLACED MISSING LIGHT COVER.SDR 2008UALA01592Control Unit · failedFLIGHT DIVERTED WITH AUTOPILOT PROBLEMS. POSSIBLE FMGC/FCU FAILURE. REPLACED FMGC/FCU COMBO. SYSTEM CHECKS NORMALLY, RESTORED TO CAT III STATUS.SDR 2008UALA01594Servo · leakingAILERON SERVO FAULT DISPLAYED. LEFT AILERON SERVO FAILURE, INTERNAL HYDRO LEAKAGE. REPLACED LEFT AILERON GREEN SERVO CONTROLLER, OPS CHECKED NORMAL.SDR 2008UALA01541Battery · faultyTHREE SVC EMERGENCY LIGHT TEST FAULTED EPSU BATTERY AFT LEFT. PERFORM RESET OF EPSU (LEFT AFT BATTERY) AND SYSTEM NOW CHECKS NORMAL.SDR 2008UALA01557Battery · faultyEPSU EXT LOAD EMERGENCY L DISPLAYED AFTER EMERGENCY LIGHT TEST. BATTERY FAILURE. REPLACED EMERGENCY BATTERY FOR OVERWING CHARGER.SDR 2008UALA01558Girt Bar · faultyDOOR 2R ARMED INDICATOR BAR MISSING. REPLACED GIRT BAR. REPLACED GIRT BAR.SDR 2008UALA01560Cover · unsecureTHE 2R SLIDE COVER FELL OFF AGAIN. PREVIOUS DAMAGE TO COVER. REPAIRED SLIDE COVER.SDR 2008UALA01459Fan · malfunctionedDIVERTED DUE TO BURNING-ACRID SMELL IN AFT CABIN. BURNT BEARING IN LT RECIRC FAN. REPLACED LT RECIRC FAN, ALL TESTS WERE NORMAL, NO SMELL NOTED.SDR 2008UALA01462Control Unit · faultyLAVATORY AND CARGO DETECTOR FAULT DISPLAYED ON UPPER ECAM SCREEN - SMOKE. SDCU FAILURE. REPLACED THE SDCU, ALL OPS CHECKED NORMAL.SDR 2008UALA01476Battery · failedDURING EMERGENCY LIGHT TEST R BATTERY FAULTED. BATTERY FAILURE. REPLACED R EMER LIGHT BATTERY. OPS CHECKED NORMALLY.SDR 2008UALA01498Oxygen System · lowCREW OXY SYSTEM NEEDS SERVICE. SERVICED CREW O2 SYSTEM, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01420Detector · malfunctionedLAVATORY DETECTOR ECAM ON SHORT FINAL. SWAPPED FWD LAV FOR AFT AND SYSTEM OPS CHECKED OK.SDR 2008UALA01382Wire · looseLEFT HAND EMERGENCY LIGHTING AT OVERWING EXIT INOP. LOOSE WIRE. SECURED LOOSE WIRE, ALL CHECKS NORMAL.SDR 2008UALA01410Smoke Detector · faultyECAM SMOKE LAVATORY DETECTOR FAULT. REPLACED FWD LAV DETECTOR. OPS CHECKED OK.SDR 2008UALA01354Oxygen System · lowTHE O2 NEEDS SERVICING SHOWS 1420. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01339Oxygen System · lowCREW O2 IS LOW AND NEEDS SERVICING. SERVICED CREW O2 TO FULL. NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01370Oxygen System · low pressureCREW O2 APPEARS TO HAVE A LEAK. SERVICED CREW O2 TO 2000 PSI, FOUND AT 1475, NO LEAKS WERE PRESENT AT TIME OF SERVICE.SDR 2008UALA01297Skin · dentedDENT BETWEEN STR 20L AND 21L 4" FWD OF FRAME 12. ACCOMPLISHED MAJOR REPAIR IN LCQ.SDR 2008UALA01332Skin · dentedDENT BETWEEN STR 20L AND 21L 4 INCHES FWD OF FRAME 12. MAJOR REPAIR ACCOMPLISHED AT LCQ.SDR 2008UALA01293Computer · failedELEVATOR-AILERON COMPUTER (ELAC) 1 INOP. FCDC1 FAULTY: SHOP FINDINGS NFF. REPLACED FCDC1, ALL OPS CHECKS WERE NORMAL.SDR 2008UALA01303Bottle · low pressureDOOR 2R EMERGENCY DOOR ASSIST BOTTLE PRESS LOW. SERVICED BOTTLE TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01296Seal · leakingINBD FLIGHT CREW, CHECK FOR SLOW 02 LEAK, LOST 200 PSI IN 2 HRS. FO FWD O2 MASK BOX LEAKING AT SEAL. REPLACED SEAL ON FO O2 STOWAGE BOX. LEAK CHECK NORMAL.SDR 2008UALA01302Slide · faultyDOOR 1L SLIDE DEPLOYED FOR EVAC AND DID NOT INFLATE AUTOMATICALLY OR BY PULLING MANUAL HANDLE. SLIDE IS REMOVED FROM AIRCRAFT. WAITING ON SHOP FINDINGS FROM SLIDE IN QUESTION. THIS INCIDENT IS UNDER INVESTIGATION FROM NTSB AND FLIGHT SAFETY.SDR 2008UALA01304Fitting · looseR AFT EMERG EXIT DISPLAYED ON UPPER ECAM SCREEN DOOR. CREW COMMENTS: HAD INTERMITTENT ECAM FOR BOTH RT SIDE OVERWING EXITS. CLEARED BY ITSELF OR BY RESEATING COVERS. LOOSE CLIPS HOLDING ASSY. TAPPED SIDE PANEL, FOUND LIGHT INTERMITTENT. REPOSITION AND TIGSDR 2008UALA01257Wire Harness · damagedROWS 14 ABC AND 21 ABC EMERGENCY PATHWAY LIGHT ON SEATS ARE INOP. UNKNOWN DAMAGE TO HARNESS. REPLACE HARNESSES AT SEVERAL POINTS. ALL OPS CHECKS PERFORMED NORMALLY.SDR 2008UALA01239Girt Bar · obstructedCREW REPORT: 2R DOOR ARMED BUT THEN DISARMED AND WOULD NOT ARM AGAIN. DEBRIS UNDER GIRT BAR. CLEANED DEBRIS, DOOR ARMS AND DISARMS NORMALLY.SDR 2008UALA01240Battery · faultyON EMERGENCY LIGHT TEST ON PTP PANEL GOT EPSU BATT FWD LEFT MESSAGE. EPSU FAILURE. REPLACED POWER SUPPLY AND BATTERY.SDR 2008UALA01196Idg · failedNR 2 ENGINE IDG POWER FEEDER CONNECTION FAILURE CAUSED DIVERSION. FOUND NR 2 ENG IDG FAILURE. NO IDG FEEDER CABLE ISSUE. REPLACED NR 2 IDG, PERFORMED INSPECTION OF IDG FEEDER CONNECTION AT PYLON AND CKECKED FOR PIN BURNING OR ARCING. AREA OK, NO ISSUES NOTESDR 2008UALA01213Slide · faultyON PTP PANEL TEST GOT EXT LOADS AFT L MESSAGE. INTERNAL SHORT IN 2L SLIDE. REPLACED DOOR 2L SLIDE. OPS CHECKED NORMAL.SDR 2008UALA01194Structure · damagedLT NR 4 LEADING EDGE SLAT DAMAGED ON ARRIVAL. REMOVED AND REPLACED NR 4 LT SLAT.SDR 2008UALA01121Bracket · bindingON TAKEOFF GOT L/G GEAR NOT UPLOCKED AND CYCLED GEAR HANDLE. GEAR RETRACT 2ND TIME. FOUND 25GA SENSOR TARGET BRACKET ASSY BINDING, CAUSING TARGET TO NOT COME INTO ALIGNMENT WITH SENSOR. FOUND TARGET BRACKET SWIVEL BUSHING AND 9366BOLT BINDING. REMOVED BOLTSDR 2008UALA01110Skin · dentedLT FUSE HAD PREVIOUSLY ARCHIVED DENTS IN ADJACENT FRAME BAYS BETWEEN FR 18 - 20 AND STR 32L AND 33L. DENTS ARE BEYOND LIMITS. ACCOMPLISHED MAJOR REPAIR IN DEN.SDR 2008UALA01111Fuel Tank · leakingFUEL LEAKING, INBD PORTION OF THE RT TANK, COMING FROM FASTENERS AND SEALANT, BY THE RT MLG GEAR DOOR. UNKNOWN FUEL LEAK. IDENTIFIED LEAKS IN TANK USING BLOW BACK METHOD. FUEL LEAKING FROM RT WING TANK AT REAR SPAR TO RIB CASTING SEPARATING WING AND CTR TANSDR 2008UALA01042Accumulator · lowR1 DOOR ACCUM PRESS NEEDS SERVICING. SERVICED TO FULL, NO LEAKS NOTED.SDR 2008UALA01043Battery · dischargedDOOR 1L FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERY DEAD. BATTERY FAILURE. REPLACED BATTERY.SDR 2008UALA01041Power Supply · faultyEMERGENCY EXIT LIGHTS FLICKERING DURING TAXI IN. UNKNOWN ELECTRICAL (BATTERY) FAULT. REPLACED RT MID CABIN POWER SUPPLY, OPS CHECKED GOOD.SDR 2008UALA01032Computer · faultyCREW REPORTS ELAC 2 FAULT. ELAC FAULT/FAILURE-NFF. REPLACED ELAC2.SDR 2008UALA01026Control Unit · defectiveF-CTL ELEV SERVO FAULT ECAM AFTER T/O. EXCESSIVE PLAY IN ROD END CONNECTOR(S). REPLACED LT BLUE ELEVATOR SERVO CONTROL UNIT (34CE3), TESTS GOOD.SDR 2008UALA00990Circuit Breaker · out of toleranceFOUND EXT LOADS AFT L ON 3 SVC. RESET EMERGENCY LIGHT CIRCUIT BREAKER, OPS CHECKED NORMAL.SDR 2008UALA00991Circuit Breaker · out of toleranceEXT LOAD EMERGENCY LEFT, AND INTERNAL LOAD EMERGENCY LEFT MESSAGE ON EMERGENCY LIGHT TEST. RESET EMERGENCY LIGHT CIRCUIT BREAKER, OPS CHECKED GOOD.SDR 2008UALA01025Chiller · shortedSMELL OF ELECTRICAL SMOKE LAST 5 MIN OF FLIGHT. AFT GALLEY, FWD CHILLER SHORTED. REPLACED CHILLER.SDR 2008UALA00973Oxygen System · lowCREW O2 NEEDS SERVICING 1420 PSI. SERVICED CREW O2 TO FULL. NO LEAKS WERE NOTED FROM THE SYSTEM.
Back to IAE V2527-A5