IAE V2527-A5
Service difficulty reports · 8,011
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011101905668Panel · leakingFUEL DRIP FROM LEFT WING OUTBOARD CANOE FAIRING. REMOVED OTBD CANOE FOR WARD FAIRING. FOUND NUMEROUS FASTENERS SEEPING FUEL ON SEVERAL FUEL PANELS. TIGHTENED FASTENERS, FILLED OUTBOARD FUEL TANK ON LEFT WING. NO LEAKS NOTED.SDR UALA2011101905657Extinguisher · dischargedAFT FIRE EXTINGUISHER AGENT LEVEL LOW. REMOVED AFT HALON BOTTLE.SDR UALA2011101805639Windscreen · delaminatedCAPTAIN'S WINDSCREEN DELAMINATING. DELAMINATION WITHIN LIMITS. LEFT LOWER CORNER MOISTURE INGRESSION, WINDOW REPLACED.SDR UALA2011101905650Ram Air Turb · faultyRAT FAILS TO ILLUMINATE GREEN LIGHT. ACCOMPLISHED AN OPERATIONAL TEST OF RAT MANUAL DEPLOYMENT AND A FUNCTIONAL TEST OF RAT USING GROUND TEST UNIT PER AMM. RAT FAILED. REPLACED RAT. RETESTED PER MM. OP'S CHECKED GOOD.SDR UALA2011101805635Light · improper partLT SEAT ROW 11 OW EMERG LIGHT ON SEAT IS WRONG COLOR SHOULD BE RED. REPLACED PER AMM WITH (P/N BR9644-22) ON WU N8664L BY 311007 AND LC-19. CHECKED GOOD.SDR UALA2011101705628Fan · seizedAIRFRAME HUM IN FLIGHT DECK. FLIGHT DIVERTED. HUM WAS FOUND TO BE EXTRACT FAN SEIZING, REPLACED EXTRACT FAN18HQ PER AMM.SDR UALA2011101805644Cone · crackedNR 1 ENGINE EXHAUST CONE CRACKED. REPLACED NR 1 ENGINE EXHAUST CONE PER AMM, CHECKED OKAY.SDR UALA2011101705600Battery Pack · inoperativeCABIN EMERGENCY LIGHTS FAILED TEST. SHOWS EPSU BATTERY FWD LT. REPLACED EPSU 10WL BATTERY PACK, OPS NORMAL.SDR UALA2011101705608Slide · crackedRIGHT OVERWING SLIDE HAS A 7.5 INCH CRACK, ALONG AFT EDGE. ALSO CRACKED IN 3, 6 INCH AND 3 INCH AND MULTIPLE CRACKS UPPER AFT EDGE. REPLACED RT OFF WING SLIDE ASSY PER AMM.SDR UALA2011101705598Latch · failedCOCKPIT CENTER JUMPSEAT WILL NOT LOCK IN STOWED POSITION. RELATCHED JUMPSEAT LATCH, LOCKS NORMAL IN STOWED POSITION.SDR UALA2011101705617Container · damagedO2 MASK CAME DOWN DURING MODERATE TURBULANCE AT SEATS 27 ABC. REPLACED O2 MASK ASSEMBLY PER MM. OPS CHECKED GOOD.SDR UALA2011101705588Snubber · faultyR1 DOOR HAS NO SNUBBING ACTION DURING LAST ONE THIRD TO ONE QUARTER OF DOOR TRAVEL IN THE CLOSED DIRECTION. SNUBBER ACTUATOR WAS REPLACED SEPT 12 . REPLACED SNUBBER PER MM. OPS CHECKED NORMAL.SDR UALA2011101705622Oxygen Mask · no testCAPT OXYGEN PRESS TO TEST INOP YELLOW INDICATOR WILL NOT SHOW. REPLACED CAPT O2 MASK ASSY, SYSTEM OPS CHECKED NORMAL.SDR UALA2011101705626Floor Panel · damagedGALLEY 401..GALLEY FLOOR IS SPONGY. PER SRM 53-12-00 PG217 TEMP REPAIR WAS MADE WITH 2024T3. PERM REPAIR MUST BE MADE WITHIN 350 FLIGHT HOURS OR 150 CYCLES, WHICHEVER OCCURS FIRST. PART NUMBER FOR FLOOR PANEL IS 110-3919 AS PER IPC 53-12-01 PG 22H-1, ITEM 8SDR UALA2011101405573Computer · malfunctionedCYCLIC VERTICAL BUMPING-PITCHING FELT AT CRUISE. FLIGHT CONTROL SD SHOWED LT & RT AILERONS MOVING UP & DOWN IN UNISON WITH BUMPING. CONSULTED FMC ELAC 1-2 FAULT, IRREGULAR. TURNED OFF ELAC 1, AILERON MOVEMENT STOPPED. NO FURTHER OCCURRENCE OF BUMPING-PITCHSDR UALA2011101405579Window · crackedNR 3 RT COCKPIT WINDOW CRACKED, RTFL. REPLACED WINDOW PER MM.SDR UALA2011101705599Oxygen Mask · unwanted deployPAX OXYGEN MASK DROPPED AT SEAT 25C. REPACKED O2 MASK, OPS CHECKED OK PER MM.SDR UALA2011101405582Amu · faultyF/O CANNOT HEAR ON HEADSET. REPLACED F/O MINITEL AND AMU. CHECKED GOOD.SDR UALA2011101205530Float Valve · wornFUEL SEEMS TO TRANSFER INFLT FROM RIGHT WING TO LEFT W- CROSSFEED CLOSED. BURN +TOTAL CORRECT. T/S FOR WING TO WING TXFER COULD NOT DUPLICATE BUT DID FIND LT WING OUTER TANK VENT FLOAT WORN OUT CAUSING TXFER FROM OUTER TO INNER TXFER AT APPROX 200LB PER HOUR SDR UALA2011101205540Proximity Switch · out of adjustRT FWD CABIN DOOR DISPLAYED ON UPPER ECAM SCREEN. REPEATED CHRONIC DOOR ECAM. ALL POSSIBLE PARTS HAVE BEEN CHANGED AT LEAST ONCE SUSPECT POSSIBLE RIGGING OF HANDLE OR HOOK PROX SENSOR. TOMC-FLAMINI ADJUSTED PROX SW 11WV1, REPLACED RELAY 12WN ACP HAND OVER SDR UALA2011101105493Ram Air Turb · malfunctionedRAT WILL NOT STOW, NO MOVEMENT.SDR UALA2011101105511Oxygen Mask · deployedSEAT 2A AND 2B OXYGEN MASK DEPLOYED. MASKS RESTOWED AS PER MT 35-003, O2 SYSTEM REQ DROP CHECK AS PER MT 35-003.SDR UALA2011101205527Pump · failedNR 1 ENG HYD PUMP FAILURE, RTFL.SDR UALA2011101205528Lens · missingEMERGENCY EXIT LIGHTING AT OVERWING SEATS MISSING RED LENS IN 2 OF 3 ROWS REQUIRING RED LENS. REPLACED LIGHT ASSY'S PER MM.SDR UALA2011101105490Duct · failedINSULATION BLOWING INTO CABIN LEFT SIDE EXIT ROW. REBONDED SEPARATED TWO HALF OF AIR CONDITION DUCT.SDR UALA2011101205545Cap · damagedAPPEARS TO BE A BIRD STUCK IN LEFT WING FLAPS OUTBOARD OF ENGINE. REMOVED AND REPLACED L/E FLAP CAP.SDR UALA2011101005463Ram Air Turb · malfunctionedDURING RAT OPS CHECK GREEN LIGHT DID NOT COME ON. REPLACED RAT TURBINE HUB ASSY, NO HELP. DUE TO FAILED TEST REPLACE RAT PUMP. REPLACED PUMP MR29225 -22 OFF, -64 ON. NO HELP, GREEN LIGHT DID NOT ILLUMINATE WHEN RAT FUNCTION TEST DONE. NEEDS FURTHER T/S COSDR UALA2011101005477Battery · dischargedEPSU BATTERY FWD LEFT FAIL TEST. REPLACED BATTERY PER TSM. DID THE OPS TEST AFTER REPLACEMENT. OPS TESTED GOOD.SDR UALA2011101105495Smoke Detector · faultySMOKE WARNING AFT LAV RESET CIDS PER FM PROC FIXED MOMENTARILY SECOND INDICATION + ELEC BURNING ODOR. REPLACED SMOKE DETECTOR. TEST PASSED, NO SMELL OF SMOKE OR ELEC BURNING ODOR NOTED.SDR UALA2011101005443Windshield Wiper · obstructedLT & RT WINDSHIELD WIPERS ARE INOP. ANTI ICE CREW COMMENTS: WIPER SWEEPS BUT DOES NOT CLEAR WINDOW. WIPERS HAD ALUMINUM TAPE AND OVERSPRAY ON THEM FROM PAINT. CLEANED OVERSPRAY, OPS CHECKED NORMAL.SDR UALA2011101005476Skin · damagedON ARRIVAL BIRD STRIKE ON LT WING OUTBD FLAP L/E HAS A HOLE ON END CAP. R & R LE FLAP CAP.SDR UALA2011101005478Computer · faultedCHRONIC ELAC FAULTS. ELEV SERVO FAULT DISPLAYED ON UPPER ECAM SCREEN. CHK'D PFR & FOUND ON FAILURE MESSAGE SEC2-MON OR WIRING TO R B ELEV SOL VLV 34CE4. RPL SEC 2. ACP OPS CHK REF MM. TEST CHECKED GOOD AND UPPER ECAM FAULT CLEARED.SDR UALA2011100705425Engine · fireFIRE DEPT EVENT ON NR 2 ENGINE. UPPER ECAM MSG " ENG 2 OVSPD PROT FAULT" DISPLAY AFTER ENGINE SHUTDOWN. ENG REMOVED AND GRIPE TRANSFERED TO ELR ON ENG. REMOVED ENGINE FOR DISASSEMBLY AND CLEANING DUE TO REPORT OF FOAM FIRE EXTINGUISHING AGENT SPRAYED INTO TSDR GTIA20111006266Cylinder · low pressureR1 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R1 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW 52-10-00-614-001.SDR UALA2011100605419Oven · malfunctionedGALLEY OVEN WON'T HEAT AT R12. CREW COMMENTS: UNEVEN HEATING ESPECIALLY ON THE BOTTOM. PULLED CB AND APPLIED STICKER. REMOVED LINED AND CLEANED OVEN, COILS AND FAN ARE WORKING PROPERLY AND FOUND OVEN TO HEAT PROPERLY.SDR GTIA20111004265Cylinder · low pressureL2 DOOR ASSIST LOW PRESSURE. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001. NO LEAKS NOTED.SDR UALA2011100505404Oxygen Mask · leakingSAMC TEXT: PRESSURE DROPPING ABOUT 10 PSI PER MINUTE. NO NOTICEABLE LEAKS AT MASKS. FOUND CAPTAINS O2 MASK LEAKING AND TEST FUNCTION INTERMITTENT. REPLACED MASK AND SWAPPED BOX TO 2ND OBSERVER POSITION REF AMM NEW CRUSH WASHERS INSTALLED AND LEAK CHECKED OSDR UALA2011100505365Battery · failedPTP PANEL FAILED FORWARD EPSU L. REPLACED BATTERY, OPS CHECKED GOOD.SDR UALA2011100505388Reservoir · faultyCIDS CAUTION LIGHT ON FWD FA PANEL. REPLACED LEFT OFFWING ESCAPE-SLIDE INFLATION RESERVOIR.SDR UALA2011100505395Seal · leakingCREW O2 FAILED, FLIGHT DIVERTED CREW O2 PRESSURE IS DECREASING EN ROUTE. STARTED AT 900 PSI DOWN TO 750 PSI AND CONTINUED TO DECREASE. REPLACED 2ND OBSERVER'S MASK AND BOX ASSY WITH NEW COPPER FLAIR SEAL LEAK CHECKED OKAY.SDR GTIA20111003264Cylinder · low pressureR1 DOOR PASSENGER DOOR ASSIST CYLINDER READS INADEQUATE PRESSURE ON GAUGE SERVICED R1 DOOR PASSENGER ASSIST CYLINDER W/ NITROGEN IAW AMM 52-10-00-614-001. NO LEAKS DETECTED AT THIS TIME.SDR UALA2011100305351Control Unit · faultedNLG STEERING FAULT, FLT DIVERTED. PER FLT MANUAL, RESET NLG STEERING SWITCH - NO HELP. NO CIRCUIT BREAKERS CYCLED. CFDS SHOWS "NO BSCU 1 DATA". REPLACED BSCU. SYSTEM TESTED GOOD. CAT III TEST CHECKED GOOD. TAXIED AIRCRAFT MAKING NUMEROUS STOPS AND TURNSSDR UALA2011100305338Epsu · faultyREF A-CK JIC 4-2020 ITEM 24 FAILS EMERGENCY LIGHTS BATTERY CAPACITY TEST MSG DISPLAYED AFTER TEST BATTERY CAP EMER R. REPLACED BATTERY, NO HELP. SUSPECT EPSU. REPLACED EPSU, OP CHECKS OKAY.SDR UALA2011100305317Control Unit · malfunctionedN-W STEERING FAULT. REPLACED SERVO CONTROL 6GC, OPS AND LEAK CHECKED GOOD.SDR UALA2011100305326Terminal Block · damagedTERMINAL BLOCK 7200 VT NR 11 ABOVE G4 GALLEY HAS THE THREADED STUD PULLED OUT OF THE BLOCK AND THE BLOCK IS BURNED. REPLACED BLOCK & TERMINALS ON BLOCK NR 11. OPS CHECKED SYSTEMS PER AWM 25-33-04 AND ESPM 20-44-51. OVEN R41 INOPERATIVE AND DEFERRED DF0960. SDR UALA2011093005303Tape · peelingON WALKAROUND CREW FOUND LEADING EDGE TAPE ON VERTICAL STAB PEELING. AREA IS APPROX 8 INCHES AND 5 FT FROM BOTTOM OF STAB. ALSO APPROX 18 FT FROM BOTTOM OF STAB PER MT55-003. REPAIRED EROSION TAPE. MT 55-003.SDR UALA2011100305352Oxygen Mask · missingO2 MASK MISSING FOR PORTABLE O2 BOTTLE AT DOOR 1L. REPLACED MASK.SDR UALA2011093005297Seat · looseSEAT 37B & C DETACHED FROM FLOOR. SEAT 37 ABC OTBD FLOOR FITTING OUT OF FLOOR TRACK. TRACK FULL OF DEBRIS. INSTALLED FITTING IN TRACK AND SECURED LOCKING TAB.SDR UALA2011092905283Rod · damagedAPU PERFORMANCE DETERIORATION. UPON APU REMOVAL AND FIRE WALL INSPECTION FOUND BAD ROD END AT LEFT UPPER OUTBD POSITION. REPLACED ROD ASSY.SDR UALA2011093005295Seal · missingFIRE EXTINGUISHER MISSING YELLOW SEAL IN AFT CABIN. SEAL REPLACED BY IAD MM.
Back to IAE V2527-A5