IAE V2527-A5
Service difficulty reports · 8,011
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011093005302Slide · unwanted deployR2 DOOR SLIDE DEPLOYED. DEPLOYED SLIDE HAS BEEN REMOVED.SDR UALA2011092805270Electrical Box · faultyAUDIO INOPERATIVE AT SEAT 26D, 29A. 26E 26F ALSO SEATS 26D 26E AND 26F OK 29, 'A' BAD. TROUBLESHOT. REPLACED SEAT BOX. OPS CHECKED GOOD.SDR UALA2011092905286Seal · faultyTHE 2ND OBS O2 MASK DOES NOT TEST PROPERLY. WHEN PRESSED TO TEST FLOW DOES NOT STOP. REPAIRED O2 MASK AND BOX ASSY WITH NEW COPPER FLAIR SEAL. OPS AND LEAK CHECKED GOOD.SDR UALA2011092805249Steering Sys · malfunctionedNOSE WHEEL STEERING FAULT DISPLAYED ON UPPER ECAM SCREEN. REPLACED NOSE WHEEL STEERING DEACTIVATION BOX PER MM. OPS CHECKED GOOD.SDR UALA2011092805271Extinguisher · leakingWATER FIRE EXTINGUISHER IN AFT CABIN LEAKING. REMOVED AND REPLACED LEAKING WATER FIRE EXTINGUISHER IN AFT CABIN OVERHEAD BIN.SDR UALA2011092905287Actuator · faultyF/O RUDDER PEDAL ADJUST INOPERATIVE. REPLACED F/O PEDAL ADJUSTMENT ACTUATOR PER MM. OPS CHECKED NORMAL.SDR UALA2011092705230Smoke Detector · faultyECAM SMOKE LAV+CRG DEFAULT. REPEAT WRITE-UP. REPLACED FWD LDCC 1WH, TESTS GOOD. LOG 2...CFDS SHOWS SAME FAULT AS PREV. UNABLE TO TEST SYSTEM UNTIL RESET OF BOTH CHANNELS OF THE SDCU. THEN TEST OK. AFTER THIS RESET FAULT RETURNED WITHIN 5 MINS. REF MM TRBSDR UALA2011092705229Smoke Detector · faultyUNABLE TO TEST SYSTEM UNTIL RESET OF BOTH CHANNELS OF THE SDCU. THEN TESTED OK. AFTER THIS RESET FAULT RETURNED WITHIN 5 MINS. REPLACED SMOKE DETECTOR 1WH IN FWD LDCC, TESTED GOOD.SDR UALA2011092705231Screw · looseF/O TRANSMIT TRIGGERON SIDESTICK LOOSE. TIGHTENED SCREW SECURING TRIGGER.SDR UALA2011092805259Smoke Detector · faultedLAVATORY SMOKE DETECTOR FAULT MESSAGE. UPON POWER TRANSFER TO SHIPS POWER. REPLACED LAVATORY SMOKE DETECTOR, MESSAGE CLEARED. BITE TESTED GOOD.SDR UALA2011092605189Door · obstructedRIGHT AFT OVERWING EMERGENCY DOOR REMOVED DUE TO WATER LEAKAGE. ACCOMPLISED INSTALLATION OF AFT RT OVERWING EXIT AFTER REMOVING DEBRIS & SMOOTHING ROUGH SEALING AREAS.SDR UALA2011092605184Knob · unsecureCAPT WINDSHIELD WIPER KNOB FELL OFF. SECURED WINDSHIELD WIPER KNOB.SDR UALA2011092305139Fastener · looseON CREW WALK AROUND FOUND FASTENER LOOSE ON RIGHT AC BAY ACCESS PANEL 192LB .2ND FASTENER INBOARD FWD CORNER. FASTENER INSTALLED AND TAPED OVER.SDR UALA2011092305142Bleed Air Sys · malfunctionedAPU RUNNING BUT NO AIR PRESSURE. ACCOMPLISHED RESET OF APU BLEED WITH OUTBOUND FLT CREW AND ALL SYSTEMS OPS NORMAL, OK WITH FLT CREW TO CLEAR ITEM.SDR GTIA20110921256Cylinder · low pressurePASSENGER DOOR L1 REQUIRES SERVICING. LOW PRESSURE. SERVICED PASSENGER DOOR L1 IAW AMM 52-10-00-614-001.SDR UALA2011092205123Director · malfunctionedCABIN PA-INT HANDSETS INOPERATIVE. RESET CIDS: NO HELP. SWAP CIDS DIRECTORS. SWAPPED THE NR 1 AND NR 2 CIDS DIRECTORS. BEFORE THE NEXT REVENUE DEPARTURE REPLACE THE NR 2 CIDS DIRECTOR MR23731-38 PCN582-9022 PER AMM. REPLACED NR 2 CIDS DIRECTOR PER MM, OSDR UALA2011092105099Battery · dischargedEMERGENCY LIGHTING TEST FAILED TEST WITH MESSAGE EPSU BATTERY AFT LT. REPLACED EPSU BATTERY AT AFT LOCATION. EMER LIGHTS TEST PASSED.SDR UALA2011092205114Manifold · leakingLOWER FUSELAGE AND TAIL STREAKED WITH OILY FLUID. REPLACED GROUND LEAKAGE MANIFOLD IAW MM. OPS CHECKED OK. CLEANED AREA OF HYD STREAKS.SDR UALA2011092205124Screw · looseCAPTAIN'S O2 WILL NOT TEST. FOUND SCREW ON SLIDER LOOSE. TIGHTENED SCREW. TESTED NORMAL.SDR UALA2011092005072Panel · damagedPANEL 191AB REMOVED FOR REPAIR. SECURED PANEL 191AB ON AIRCRAFT.SDR UALA2011092005087Duct · faultyCREW REPORT: RUMBLING NOISE AND MILD VIBRATION IN LOWER NOSE AREA OF A-C. NOTICED RIGHT AFTER T-O. SAMC TEXT: CHECK NOSE GEAR DOORS AND SEALS FOR CONDITION AND SECURITY. CHECK RADOME SEAL, E AND E DOOR SEALS. CHECK DUCTING IN E AND E COMPARTMENTS AND NOSESDR UALA2011092005059Computer · faultyNR 1 FMG COMPUTER LOSS, FLIGHT DIVERTED. LDG ELEV FAULT DISPLAYED ON UPPER ECAM SCREEN. - CAB PR PROG TEXT: DUP ITEM PER OPBLM. REPLACED FMGC1, ACCOMP CFDS BITE REF MM.SDR UALA2011091905041Tail Cone · damagedAPU TAIL CONE COMPARTMENT DAMAGED FROM WING TIP CONTACT OF AIRCRAFT 6664. TAGGED COCKPIT, DISCONNECTED ELEC SYS COMPONENTS & APU BLEED DUCT SECTION IN PREPARATION FOR TAIL CONE REPLACEMENT. REPLACED TAIL CONE.SDR UALA2011092005076Fuse · blownBACKLIGHT IS OUT ON AIR COND OVERHEAD PANEL IN COCKPIT. AIR COND PANEL LIGHTPLATE IS INOP. NEEDS LIGHTPLATE 565-1144. NON STOCK SEATTLE. REPLACED FUSE IN POWER SUPPLY.SDR UALA2011092005078Valve · faultyAFT CARGO HOT AIR VALVE WILL NOT OPEN. TRIED RESET, NO HELP. REPLACED PRV VALVE, OPS CHECKED GOOD, NO FAULTS NOTED.SDR UALA2011091905057Girt Bar · out of adjustUPON BLOCK IN CLEANERS UNABLE TO OPEN DOOR 2L FROM OUTSIDE. ADJUSTED GIRT BAR MATERIAL PER. DOOR OPERATION NORMAL.SDR UALA2011091905031Light · out of positionEXIT PLACARD 1R FELLOUT. ROBBED LIGHT ASSY FROM AC 4029. INSTALLED, TESTED NORMAL.SDR UALA2011091604998Servo Control · malfunctionedMOD - TO HEAVY MOD VIBRATION FELT DURING CLIMB 339IAS. FL250 CLIMBING VIBRATION CAME ON ABRUPTLY AND FELT AS IF SOMETHING WAS GOING TO COME OFF. AFT FLT ATTENDANT THOUGHT IT WAS SEVERE, 100 TIMES STRONGER THAN ANYTHING SHE HAS EVER FELT. OPBLM FIELDS. SAMSDR UALA2011091605007Slide · faultyEXT LOADS FWD L' FAULT WHEN PERFORMING EMERGENCY LIGHTS TEST. ORDERED SLIDE TO TROUBLESHOOT THE FAULTY SLIDE. NOT ABLE TO TROUBLESHOOT DUE TO WORK ON RT FWD DOOR. SLIDE IS IN LSR DROP. T/S EMG LIGHT TEST. DUAL SLIDE LIGHT FAILURES DOOR 1R AND 1L.SDR UALA2011091605000Connector · dirty(INT LOADS FWD LT) MSG SHOWS AFTER EMERGENCY LIGHTS TEST. ON CABIN CIDS DISPLAY. PLACED SLIDE LIGHT BYPASS TEST PLUG, ONE AT A TIME AT EACH DOOR SLIDE. MSG REMAINS EACH TIME. REMOVED CONNECTOR ON FWD LEFT BATTERY ABOVE CEILING PANEL AT DOOR 1L. CLEANED CONSDR UALA2011091404971Duct · cloggedCREW REPORTED NO AIR FLOW FROM GALLEY AIR VENT AND LOW FLOW IN AFT AFT LAV AREA. LOW FLOW IN AFT LAV CLEAN OUT STILL LOW FLOW IN AFT GALLEY AIR VENT. SUSPECT CLOGGED LINE BLOCKAGE IN DISTRIBUTION DUCT AREA K PER IPC AND POSSIBLE BLOCKAGE AT ITEM F. SUGGEST SDR UALA2011091604996Wire · shortedCHRONIC NR 2 ENG FIRE LOOP. WILL ACP ALL CALLOUTS. NEED 1.5 TO 2.0 SHIFTS TO COMPLETE. RANG WIRES FROM 4000WD2 TO 2WD2, CHECKS GOOD. NO FAULTS FOUND WHEN SHAKING WIRE BUNDLE FROM 400WD2 TO 409VC2. CHK'D 450VT2 SECURTIY OF WIRES, NO FAULTS FOUND. CHK'D 4000SDR UALA2011091204927Control Valve · faultyCREW REPORTS ACFT NEEDS EXTRA POWER TO GET ROLLING FROM STILL AND WHEN ADVANCING TO TAKEOFF POWER THE ACFT WAS LAGGING IN ACCELERATION. CREW FURTHER REPORTS THE RIGHT GEAR BRAKE TEMPS ARE 100+ DEGREES HIGHER THAN THE LEFT. TROUBLESHOT PER TSM 32-45- 00-810-8SDR UALA2011091304950Power Supply · faultyEPSU INT LOAD AFT L MESSAGE FOUND DURING EEL TEST (13WL). REPLACED EMERGENCY POWER SUPPLY UNIT 13WL IN AFT CABIN. OPS CHECKED GOOD.SDR UALA2011091304952Connector · not seatedEMERGENCY LIGHTS OUT AT ROW 28-30, AND ROW 22-24. RESEATED CONNECTORS AT SEAT BOX LOCATIONS AT ROWS 28-30 AND 22-24. OPS CHECK GOOD. ACPD ON WU Y 1056H.SDR UALA2011091304954Shade · crackedSLIGHTLY CRACKED WINDOW BLIND ASSEMBLY. REPLACED WINDOW BLIND ASSEMBLY.SDR UALA2011091204915Ram Air Turb · faultyTHIS ITEM FOR WORK PROGRESSION OF EG5720, RAM AIR TURBINE REPLACEMENT. REPLACED RAM AIR TURBINE. NEED TO DO FUNCTIONAL TEST AND PANEL INSTALLATION DUE TO RAT REPLACMENT REF EG5720. NUMBERS ARE ALREADY RECORDED IN EG 5720 MR29222-11 OFF MR29222-19 ON. REPLACSDR UALA2011091204901Slide · deployedTHE 1L SLIDE DEPLOYED AT GATE. REPLACED EMERGENCY DOOR SLIDE AT 1L.SDR UALA2011091204899B-Nut · leakingHYD FLUID LEAKING FROM LEFT MAIN LANDING GEAR AND AROUND LEFT GEAR DOOR BELLY AREA. ACCOMPLISHED LM1665. FOUND IN LT GEAR AREA LINE WITH LOOSE B-NUT. SECURED B-NUT AND LEAK CHECKED NO LEAKS NOTED. ALSO ACCOMPLISHED LM1663 AND LM1664.SDR UALA2011090904892Oxygen Mask · inoperativeCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED O2 MASK ASSY.SDR UALA2011090904889Packing · damagedCREW REPORT: ON WALK-AROUND OBSERVED OIL DRIPPING PUDDLING UNDER ENG 1. SAMC TEXT: FBO TO EVALUATE SOURCE AND TYPE OF FLUID AND REPORT FINDINGS TO SAMC-EMC. FBO FOUND PACKING DAMAGED ON PRESSURE LINE TO NR 5 BEARING CAVITY MATING SURFACE. PIX POSTED ESN VSDR UALA2011090704858Flap · dentedRIGHT OTBD AFT FLAP HAS 2 EA DENTS. 1 EA AT 1 8 IN INBD OF CANOE AND 1 IN FROM TRAILING EDGE, 1.125 IN DIA NR 2 DENT LOCATED 2.5 IN INBD OF CANOE 4 IN FROM TRAILING EDGE. DENT IS 1.5 X 2.0 IN SIZE. BOTH DENTS ARE .062 DEEP. FOA ON ARR BY RAMP. NOT ENVIRONSDR UALA2011090704834Stowage Box · defectiveCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. REPLACED CAPTS O2 BOX AND TESTED.SDR UALA2011090704864Door · faultyO2 MASK HOLDER ABOVE 37 DEF IS ABOUT TO OPEN. REMOVED O2 CONTAINER AND REPLACED DOOR ASSY AND LATCH ASSY. MISSING TEST BUTTON ASSY & THEN REINSTALLED. INSTALLED TEST BUTTON, ACP ADJ AND TEST. CHKS GOOD.SDR UALA2011090504772Wedge · debondedRT OUTBOARD FLAP T/E WEDGE DISBONDED AT EXISTING REPAIR LOCATED AT APPROX MID-SPAN OF FLAP. DAMAGE REPAIRED PER SRM. REF WU D6027Y BY 309889 AND LC-03.SDR UALA2011090504773Flap · dentedLEFT OUTBOARD FLAP TRAILING EDGE HAS A 9 INCH BY 2 INCH DENT IN IT APPROXIMATELY A HALF INCH DEEP. DENT IS JUST INBOARD OF THE OUTBOARD HOIST POINT FOR THE FLAP. DAMAGE REPAIRED PER SRM REF WU D6023Y BY 311012 AND LC-03.SDR UALA2011090504802Switch · out of adjustRAT WILL NOT STOW, AFTER OPS CHECK. ADJUSTED RAT LEG POSITION SWITCH. OPS NORMAL.SDR UALA2011090504794Stowage Box · faultyCAPTAINS O2 MASK WILL NOT TEST - NO YELLOW CROSS WHEN TEST-RESET IS PRESSED. REPLACED CAPT 02 BOX, OPS CHECK GOOD.SDR UALA2011090204721Guard · missingCREW REPORT: ON LANDING EMERGENCY LIGHTS CAME ON AND STAYED ON WITH THE SWITCH MOVED TO OFF. FOUND AFT FLT ATTD POSITION EMERG LIGHT SW TURNED ON. THE SWITCH GUARD IS MISSING FROM THE PANEL. ITEM 90 (582-1251), OR PANEL ASSY ITEM 1 (582- 9510). REPLACED PSDR UALA2011090504777Seal · leakingCIDS CAUTION LIGHT ILLUMINATED. MAINT TEXT: LEFT EMERGENCY SLIDE PRESSURE LOW. UPON BOTTLE INSPECTION FOUND APU PRESSURE LEAK BLOWING DIRECTLY ON THE LEFT EMERGENCY OVERWING SLIDE INFLATION BOTTLE, HEATING IT UP TO THE POINT THAT THE GREEN SCALE WAS PEGGED
Back to IAE V2527-A5