IAE V2527-A5
Service difficulty reports · 8,011
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011030901151Window · failedOUTER PANE SHATTERED ON 2L SLIDING WINDOW. REMOVED 2L SLIDING WINDOW PER MM. INSTALLED NEW PANEL IN WINDOW FRAME. COMPLETED WINDOW INSTALLATION IAW MM.SDR UALA2011030801130Lanyard · unsecureAFT RT SLIDE RAFT SURVIVAL KIT LANYARD AND RELEASE STRAP FOUND LOOSE. RE-INSTALLED LANYARDS. SLIDE RAFT RESTORED TO TOLERANCE.SDR UALA2011030801141Computer · faultyFUEL DISCREPANCY. FUEL SHUT OFF EARLY. GALLONS ADDED CORRECT BASED ON INBD FUEL LOAD. SMB EARLY DAYS VENTING TANK. PLAN TANK ENTRY ON DAYS TO REPLACE CONDENSICON ON DAY SHIFT. REPLACED BOTH MAGNETIC LEVEL INDICATOR & HOUSING PER MM.SDR UALA2011030801131Switch · bindingOPERATING THE WING ILLUMINATION SWITCH REQUIRES MORE THAN HUMAN STRENGTH. REPLACED SWITCH. WING LIGHTS OP CHECK OKAY.SDR UALA2011030801132Light · faultyEMERGENCY EXIT LIGHTS ON FLOOR AND CEILING FLICKER. RELAMPED LEFT FWD OVERWING EXIT LIGHT.SDR UALA2011030901144Tru · malfunctionedBURNING ODOR OCCURED AT THE SAME TIME AS TRANSFORMER RECTIFIER 1 FAULT. FOUND FAULTY TRANSFORMER. REPLACED NR 1 TRANSFORMER RECTIFIER, OPS NORMAL.SDR UALA2011030701112Light · inoperativeFAILS EMERGENCY LIGHT TEST EXT LOADS AFT LEFT MESSAGE. COMPLETED TEST OF AFT SLIDE RAFTS AND FOUND AFT RT HAS BAD LIGHT. REPLACED 2R DOOR SLIDE PER MM, OPS CHECKED NORMAL. VERIFIED INSTALLATION OF DOOR 2R SLIDE PER MM. SLIDE SHOWS ARMED AND CIDS TESTS NORSDR UALA2011030801137Bracket · brokenAFT CABIN FWD LAVATORY UNDERSINK VANITY DOOR BROKEN. DOOR HINGE BROKEN AWAY FROM VANITY ASSEMBLY. PART OF FIRE INTERGRITY OF LAVATORY FIRE EXT SYSTEM. LAVATORY NOT USEABLE. INSTALLED NEW BOTTOM BRACKET.SDR UALA2011030701088Sensor · faultyRT GEAR DISAGREE FAULT, RTFL. PERFORMED VISUAL INSPECTION OF RT MLG UPLOCK AND ELECTRICAL CONNECTIONS. NO DAMAGE NOTED, CONNECTORS INTACT AND CONNECTED TO UPLOCK. ACCOMPLISHED MLG AND NLG FULL STRUT SVC. FOUND SENSOR 25GA FAILING LGCIU GROUND SCAN. REPLACEDSDR UALA2011030701084Bypass Switch · leakingABNORMAL ODOR IN COCKPIT AND CABIN DURING CLIMB AND DESCENT. FLT ATTENDANTS REPORTED ODOR CAUSING EYE AND THROAT IRRITATION AND WAS STRONG IN THE CABIN. ACCOMPLISH TROUBLESHOOTING STEPS AS OUTLINED IN MT 72-016. TROUBLESHOOTING TO INCLUDE BORO OF HPC STAGESSDR UALA2011030701091Light · inoperativeEMERGENCY LIGHT TEST FAILS, FAULTING FWD L INT LOADS AND FWD L EXT LOADS. REPLACED POWER SUPPLY AND BATTERY PER MM 33-51- 58. NO HELP. FOUND BAD LAMPS IN FWD ENTRY DOOR LIGHT 21WL. RELAMPED PER MM 33-51-11. TEST NORMAL.SDR UALA2011030701093Bolt · shearedBOLT SHEARED THAT APPEARS TO ATTACH FLOORBEAMS TOGETHER. LOCATION IS AFT PIT, FWD WALL, ABOVE UPPER RT CORNER. REPLACED BOLT FOR FLOORBEAMS. REINSTALLED FLOOR AND SIDE WALL PANELS.SDR UALA2011030701096Wire · shortedWIRE BUNDLE SHORTED 6' AFT OF 7437VC UNDER ATTENDANT SEAT. SUPPLEMENTAL DATA UPDATE HARNESS ROUTES UNDER FLOOR. RESEARCHING HARNESS. FOUND WIRE BUNDLE BETWEEN 7437VC-A AND 6761VC-A TO BE OK. WIRES 2373-4 165B AND 2373-7958B ARE SHORTED TO SHIELD BETWEEN 67SDR UALA2011030401076Rod End · wornLT ELEVATOR OTBD SERVO FAILS EXCESSIVE PLAY CHECK PER MM. REPLACED OTBD SERVO EYE-END. COMPLETED INSTALLATION UP TO PARAGRAPH A(6) OF MM.SDR UALA2011030701119Skin · scratchedDENT AFT OF DOOR 2L HAS SCRATCH APPROX 1.5 INCHES LONG, PART OF SCRATCH IS DOWN TO BARE METAL. MAJOR REPAIR ACCOMPLISHED: DEPTH IS NEGLIGIBLE. EXTERNAL DOUBLER REPAIR INSTALLED BETWEEN FR69 & 70 AND AT STRINGER 18L AFT OF L2 DOOR. THIS IS A TIME LIMITED REPASDR UALA2011030701120Panel · dentedPANEL 423BL HAS 2 DENTS IN PYLON SKIN PANEL. TOP DENT IS 4X 2.75D-.0625 DEEP, LOWER DENT IS 4 X 3-. 0125 DEEP. BOTH DENTS WERE WITHIN RATIO FOR CARRY FORWARD TO THE NEXT 'C' CHECK 26SEPT2012 BUT NOT TO EXCEED 04NOV, 2012 (20 MONTH LIMIT OR PTC 25306) PER SRM.SDR UALA2011030301044Amu · inoperativeCAPT OXYGEN MASK MICROPHONE IS INOPERATIVE. SUPPLEMENTAL DATA UPDATE MECHANIC SWAPPED MASKS, NO HELP. SUSPECT ELECTRICAL CONNECTION AT BOX. REPLACED AMU IAW MM. ACCOMPLISHED OPS CHECK OF CAPT O2 MASK MIC OKAY.SDR UALA2011030401060Transceiver · faultyCAPT HEADSET CANNOT RECEIVE. STARTED DURING DESCENT. SPEAKER AND TRANSMIT WORKS FINE. REPLACED VHF 1. SYSTEM CHECKS NORMAL WHILE AT THE GATE USING 128.95. CAPTS HEADSET STILL INOP, COMPLIED WITH MEL. LOSS OF TRANSMISSION FROM CAPT'S BOOMSET- NEED AMU (1RSDR UALA2011030301052Valve · leakingFUEL LEAKING AROUND RT WING FUEL TANK INBD WATER SUMP DRAIN AND PUMP AREA. DRIED AREA, LEAK IS FROM SUMP DRAIN AND PUMP AREA. REPLACED SUMP VALVE 26QM.SDR UALA2011030201031Power Supply · failedCABIN EMERGENCY LIGHT TEST FAILED ON 3 SERVICE. REPLACED POWER SUPPLY 110W L2. CABIN EMERGENCY LIGHT TEST PASSED, OPS CHECKED NORMAL.SDR UALA2011030201032Pump · activatedRAT TEST FAILED. GREEN LIGHT DID NOT ILLUMINATE, RAT DID NOT COME UP TO SPEED. REPLACED RAT HYDRAULIC PUMP AND RAT GROUND CHECK MODULE. RAT FAILED TEST. RAT WILL NOT COME UP TO REQUIRED SPEED AND GREEN LIGHT WILL NOT ILLUMINATE.SDR UALA2011030301049Bushing · faultyUNUSUAL VIBRATION WITH FLAPS FULL ON 2 CONSECUTIVE FLIGHTS. ACCOMPLISHED FLT CONT INSPECTION PAYING PARTICULAR ATTENTION TO THE FLAP NR 1 SPHERICAL BEARING LINER MIGRATION. NO DEFECTS NOTED. NO HISTORY AND POST FLT REPORT IS CLEAN. OK TO CONTINUE IN SERVICSDR UALA2011030201017Ball Lock · inoperativeSLIDE MR25622-051 RECEIVED IN PACKED CONDITION. UPON CHECKING THE BALL LOCKS ON THE ENCLOSURE ASSY., FOUND ALL THREE BALL LOCKS (P/N 60878-5) INOPERATIVE. SUPPLEMENTAL DATA UPDATE NO OTHER DISCREPANCIES NOTED. TROUBLESHOOTING. REPLACED RH OVERWING SLIDE ASSY. SDR UALA2011022800982Skin · separatedNR 1 ENGINE INBD THRUST REVERSER BULL NOSE AREA, INNER SKIN FOUND COMPLETELY SEPARATED DURING ROUTINE INBOUND CHECK. NR 1 ENG INBD THRUST REVERSER REPLACED ON ROUTINE DOCK WU P5781W.SDR UALA2011022800984Lens · wrong partSEAT 9 ABC EMERGENCY LIGHT LENS IS WHITE. SHOULD BE RED. FOUND RED LENS INSTALLED AT SEAT ROW 7. SWAPPED LENS TO CORRECT POSITIONS. INSPECTED PER MM.SDR UALA2011030201018Ball Lock · faultySLIDE MR25621-050 RECEIVED IN PACKED CONDITION. UPON CHECKING THE BALL LOCKS ON THE ENCLOSURE ASSY, FOUND ONE BALL LOCK (P/N 60878-5) INOPERATIVE. FOUND FOAM IN SUPPLY LINE IN FITTING AT BALL LOCK (SUSPECT MARINE TEX FOAM FROM ORIGINAL MFG). FOUND CHECK VALSDR UALA2011022800992Oxygen Mask · leakingCAPT OXY MASK BLEEDS OFF CREW OXY PRESSURE. SWAP WITH 2ND OBS MASK & DF 2ND OBS SEAT. COMPLIED WITH MEL, ENTIRE CAPT OXYGEN MASK BOX SWAPPED WITH 2ND OBS PER MM. SERVICED O2 TO 1840 PSI DEN. O2 AT 1360 INBOUND. RPLD 2ND OBS MASK REF MM.SDR UALA2011022500942Tank · leakingFUEL LEAKING FROM WING INBD OF RT ENGINE. RT WING TANK OPENED & VENTED FOR DRY BAY FUEL MX ACCESS. LOCATED AND SEALED SOURCE OF DRY BAY LEAK. SEALANT APPLIED 1500-24. ACCOMPLISHED LEAK CHECK.SDR UALA2011022500943Wheel · crackedON ARRIVAL FOUND NR 2 WHEEL ASSY CRACKED AND RUBBING ON BRAKE ASSY. NR 2 MLG BRAKE ASSY DAMAGED FROM BROKEN WHEEL ASSY. REMOVED NR 2 WHEEL ASSY. INTERIM INSTALLATION OF TIRE AND WHEEL ASSY FOR ACFT TOWING. REPLACED BRAKE ASSY. FOUND NR 2 MLG TACHOMETER FISDR UALA2011022500941Slide · out of toleranceBOTH LT AND RT OFF WING SLIDE DOOR PINS PAINTED OVER. VEDOR REMOVED PAINT BUT SLIDES NEED REPLACEMENT. BOTH LT & RT DEFECTIVE OVERWING SLIDES REMOVED. COMPLETED INSTALLATION OF LT AND RT OVERWING SLIDES.SDR UALA2011022400909Pin · overservicedLT OVERWING SLIDE ENCLOSURE DOOR BALL LOCK PINS OVERSERVICED. LT OVERWING EMERGENCY ESCAPE SLIDE REMOVED. SECURED NEW SLIDE ASSY REF AMM. DURING OVERWING SLIDE REPLACEMENT, FOUND WIRE 3067-CF18 DAMAGED. REPAIRED WIRE.SDR UALA2011022500950Tiller · obstructedCAPTAIN'S NOSE WHEEL STEERING HANDWHEEL INOPERATIVE. CAPTAIN'S TILLER STIFF AND BINDING. SLOW TO CENTER. REPOSITIONED COCKPIT INTERIOR PANEL FOR PROPER CLEARANCE WITH CAPTAIN'S TILLER KNOB.SDR UALA2011022500952Head · looseFWD CARGO FIRE EX BOTTLE 4005WX (FWD BOTTLE) HAS LOOSE DISCHARGE HEADS AND ARE NOT SAFETY WIRED. FWD BOTTLE DISCHARGE HEADS TORQUED AND SAFETIED BY SFOOV AMT RENDLER FN 027968 ON WRITE UP K5055C.SDR UALA2011022400915Bottle · low pressureDOOR 2R, EMERGENCY DOOR ASSIST BOTTLE PRESSURE LOW. SVC BOTTLE PRESSURE IAW AMM.SDR UALA2011022500957Control Module · failedHYD RAT FAILS OPS TEST. REPLACED RAT GROUND CONTROL MODULE, NO HELP. REPLACED RAM AIR TURBINE. OPS ARE NORMAL.SDR UALA2011022400910Valve · faultyNOSE WHEEL STEERING FAULT DISPLAYED ON UPPER ECAM SCREEN, WHEEL. LOST NOSE WHEEL STEERING AFTER LANDING. CYCLED ANTISKID, NOSE WHEEL STEERING SWITCH TO REGAIN CONTROL. REPLACED 49GA LANDING GEAR SAFETY VALVE, NLG STEERING LOCKOUT AND 15GA LT MLG DOWNLOCK SENSDR UALA2011022400913Connector · faulty"ATA 33-51-38 EXT LOADS EMER L" DISPLAYED DURING EMERGENCY LIGHT TEST. IAW TSM PERFORMED OPS TEST OF EMERGENCY LIGHTS NOT WITH CIDS TASK 33-51-00-710-006 FAULT ON POWER SUPPLY IS EXTERNAL LIGHTS REPLACED AFT EMERGENCY LIGHTS ON WING AFT LIGHTS NOW FLASH DURINSDR UALA2011022500951Lug · corrodedTHE RT MLG RIB 5 FWD LUG DIAMETER WAS FOUND WITH CORROSION. CLEAN-UP OUT OF LIMITS OF SRM. A TEMP REPAIR WAS ACCOMPLISHED REF REO-L01301. CORROSION DAMAGE REMOVED & REWORK ACCOMPLISHED WITH OVERSIZED BORE & BUSHING REPLACEMENT IAW REO-L01302 & UA-EVA-80611.SDR UALA2011022400924Slide · out of toleranceLT OVERWING SLIDE PAINTED OVER ENCLOSURE DOOR BALL LOCK PINS. REPLACED LT OVERWING SLIDE IAW MM.SDR UALA2011022400925Slide · out of toleranceRIGHT OVERWING SLIDE PAINTED OVER ENCLOSURE DOOR BALL LOCK PINS. REPLACED RT OVER WING SLIDE IAW MM.SDR UALA2011022400927Slide · out of toleranceLT OVERWING SLIDE OUT OF TOLERANCE. REPLACED LT OVERWING SLIDE ASSY. ALSO PERFORMED EMERGENCY LIGHT TEST, CHECKS GOOD. INSPECTED LT OVERWING SLIDE. SLIDE ASSY SECURED ON ACFT. CONNECTOR SECURED, INFLATION LINE SECURE, EMERGENCY LIGHTS TEST OK. ACFT RETURNSDR UALA2011022400926Slide · out of toleranceRT OVERWING SLIDE OUT OF TOLERANCE. REPLACED RT OVERWING SLIDE ASSY. ALSO, PERFORMED EMERGENCY LIGHT TEST, CKS GOOD. INSP SLIDE ASSY, SLIDE IS SECURED ON RT SIDE, CONNECTOR IS SECURE, INFLATION LINE IS SECURE, EMERGENCY LIGHTS TEST OK. ACFT RETURNED TO NORSDR UALA2011022500948Drain Line · leakingNR 2 ENG LEAKING FUEL. RAN NR 2 ENG REF AMM 71-70- 00. FOUND FUEL FROM "CORE", 12 DPM. SHUT ENGINE DOWN, FUEL LEAK, 3 DROPS PER MINUTE FROM "CORE". ACCEPTABLE TO FLY ON 25 HRS PROVIDED THE 25 HR FLYBACK LIMIT IS NOT EXCEEDED. FUEL LEAK IS FROM DRAIN MAST, SDR UALA2011022200902Switch · stuckF/O OXYGEN MASK MICROPHONE IS INOPERATIVE. F/O O2 MASK PRESS TO TEST-RESET SW IS JAMMED. REPLACED F/O O2 MASK BOX. OPS NORMAL.SDR UALA2011022200903Valve · faultyDURING LANDING ROLLOUT, GOT ECAM CRC LANDING GEAR NOT DOWN AND ECAM WHEEL-NLG STEERING FAULT. ACTUAL NOSE WHEEL DID FAIL. ACFT TOWED TO GATE. REF TSM. PREVIOUS ACFT WITH THIS ISSUE RELATED TO FAULT CODE "53". NO FAULTS ON EITHER LGCIU FOR ANY SENSORS, BITE TSDR UALA2011022100864Unknown · vaporAVIONICS SMOKE MSG, RTFL CREW REPORT: AVIONICS SMOKE ECAM INDICATION BUT NO ACTUAL SMOKE. APPEARS TO BE FALSE INDICATION. OPENED AND INSPECTED THE AVIONICS COMPARTMENT, NO SMOKE AND NO DEFECTS NOTED. SUSPECT THE HUMIDITY CAUSED VISUAL EFFECT. RESET SDCU'S ASDR UALA2011022100868Accumulator · overservicedDOOR 1L SLIDE ARMING LEVER IS STIFF DIFFICULT TO ARM. FOUND DOOR DAMPNER ACCUMULATOR OVERSERVICED. SERVICED TO CORRECT PRESSURE IAW AMM.SDR UALA2011022100852Extinguisher · missingMISSING 1 HALON FIRE EXTINGUISHER. CABIN CREW REPORTED ONLY 2 FIRE EXT ON BOARD. REPLACED BOTTLE.SDR UALA2011022100879Wire · shortedFOUND WIRE 7109-B DAMAGED AND SHORTING TO SHIELD. DAMAGE IS IDENTIFIED WITH MASKING TAPE NEAR MIDDLE BLOWOUT PANEL, FWD PIT FWD BULKHEAD. REPLACED WIRE 7109-A AND 7109-B FROM TERMINAL BLOCK 1842VT TO BENCH PLUG AD OF SFCC-2. OPS CHECK AND TESTS ACP, CHECK OSDR UALA2011022100881Wire · damagedEMERGENCY LIGHT CHECK FAILED INT LOADS AFT L 33-51-38. T/S FOUND WIRING UNDER SEAT 19ABC DAMAGED. REPAIRED WIRING, EMERGENCY LIGHT PASS 3 SERVICE TEST FROM FWD F/A PANEL.
Back to IAE V2527-A5