Pratt & Whitney Canada PW120A
Service difficulty reports · 2,399
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW120A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW120A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA140425002Diode · burned(CAN) DURING SCHEDULED REPLACEMENT OF A RT MLG COMPONENT, A BURNED DIODE WAS OBSERVED IN THE NACELLE. DIODE 2762-CR4, WDM 27-19-01 SHEET 4, WAS REPLACED, ROLL SPOILER SYS TESTED AND THE ACFT RELEASED FOR SERVICE.SDR CA140506007Oil Cooler · leaking(CAN) COMPLETE OIL LOSS OF NR 2 ENGINE AFTER SHUTDOWN AND INSPECTION, FOUND OIL LEAK TO BE COMING FROM OIL COOLER ON NR 2 ENGINE. OIL COOLER FITTINGS FOUND DRY. FOUND LOWER COOLER FINS TO BE WET. REPLACED R/E OIL COOLER AND ATTACHING FITTINGS O-RINGS. REPLESDR HNAA2014040400123Garlock Seal · leakingDURING FLIGHT, AT LOW POWER SETTINGS, HOT ODOR IS EMITTED IN COCKPIT AND CABIN AT HIGH POWER SETINGS AND ON GROUND. INSPECTED BOTH ENGINE AIR SWITCHING VALVES AND APU AREA. NO DISCREPANCIES NOTED. FOUND NR 2 ENGINE GARLOCK SEAL LEAKING. R & R GARLOCK SEAL. SDR CA140328001Sequence Valve · failed(CAN) CREW REPORTED THAT AFTER TAKEOFF, THE NOSE GEAR DOORS DID NOT CLOSE POST GEAR RETRACTION. THE GEAR WAS CYCLED IAW CREW QRH AND EXPERIENCED THE SAME RESULT. CREW OPTED TO SELECT GEAR DOWN, DUE TO ICING CONDITIONS, THE FLIGHT DIVERTED. MAINTENANCE ACTISDR CA140313009Brace · failed(CAN) RT MLG COLLAPSED WHILE TAXING OFF RUNWAY. SIDE BRACE LOWER ARM SEPARATED FROM MLG ASSY.SDR CA140305002Windshield · failed(CAN) DURING CRUISE, F/O WINDSHIELD SHATTERED. FLIGHT CREW ELECTED TO DIVERT TO THE NEAREST SUITABLE AIRPORT AND LANDED WITHOUT FURTHER INCIDENT. VISUAL INSPECTION OF THE WINDSHIELD BY MAINTENANCE CONFIRMED THAT ONLY THE OUTER FACE WAS SHATTERED. DECISION WASDR CA140307001Socket · burned(CAN) UPON ARRIVAL AT THE ACFT FLIGHT CREW REPORTED AN ELECTRICAL ODOR IN THE CABIN. MAINTENANCE FOUND A BURNED FIX LAMP HOLDER ON ONE OF THE CABIN SIDEWALL FLUORESCENT LAMP FIXTURE. THE LAMP ASSY WAS DISABLED AND THE ACFT RELEASE UNDER MEL. LAMP HOLDER WAS SDR CA140228005Elt · malfunctioned(CAN) ELT ACTIVATED WHILE ON THE GROUND, REASON UNKNOWN.SDR CA140522007Actuator · failed(CAN) ON CLIMBOUT, THE RUDDER TRIM INDICATOR DID NOT MOVE WHEN THE TRIM SWITCH WAS ACTUATED. THE CREW RADIOED IN TO SAY THAT THEY WERE RETURNING AND THEY LANDED WITH NO INCIDENT. THE ENGINEERS WERE IMMEDIATELY IN ATTENDANCE AND DIAGNOSED THE RUDDER TRIM ACTUSDR HNAA2014012700022Engine · surgesNR 2 ENGINE TORQUE SURGED ON TAKEOFF ROLL FROM 90 PERCENT DOWN TO 70 PERCENT. INSPECTED NR 2 ENGINE. NO VISUAL DEFECTS NOTED. GROUND RAN ACFT TO 90 PERCENT TORQUE. NO TORQUE OR OTHER ENGINE PARAMETERS FLUCTUATED. ACFT IS OK FOR SERVICE.SDR HNAA2014012000014Oil System · leakingDURING TAKEOFF ROLL, NR 2 OIL PRESSURE ADVISORY LIGHT ILLUMINATED. SHUTDOWN ENGINE AND RETURNED TO GATE. LOWER COWL AND FOUND OIL DRIPPING FROM FORWARD END DRAINS. REMOVED LOWER COWLING. CLEANED EXCESSIVE OIL AND R & R NR 2 ENGINE IAW WC 71-00-01A AND 71-00-SDR 39LA2014011552Landing Gear · malfunctionedLANDING GEAR MALFUNCTION AFTER GEAR SELECTED UP. SELECTED GEAR DOWN PER IRREGULAR CHECKLIST & GEAR MOVED TO DOWN & LOCKED.SDR 39LA2014010844Door Frame · crackedPAX DOOR FRAME CRACKED AT THE UPPER FWD CORNER, INBD SIDE, JUST ABOVE STRINGER 9L. REPAIRED PAX DOOR FRAME CRACK AT UPPER FWD CORNER IAW BOMBARDIER REPAIR DRAWING 8-53-13454 REV 3.SDR 39LA2014010845Skin · dentedDENT WITH GAUGE RT FUSELAGE SKIN STATION X 280.00, STRINGER 21R. REPAIRED DENT IN RT FUSELAGE SKIN STATION X 280.00, STRINGER 21R IAW RD 8-53-13455.SDR 39LA2014010846Frame · crackedFRAME 488.5 AT STRINGER 30R & 31R FOUND TO BE CRACKED. REPAIRED CRACKED FRAME 488.5 AT STRINGER 30R & 31R IAW DHC-8-100 SRM 53-20-21.SDR 39LA2014010847Support Angle · crackedLEFT VERTICAL SUPPORT ANGLE FOR RADAR CRACKED ON UPPER END. REPAIRED LT VERTICAL SUPPORT ANGLE FOR RADAR ON UPPER END IAW RD 8-53-7275.SDR 39LA2014010848Door Frame · damagedPERFORM A PERMANENT REPAIR OF THE RT FWD EXIT DOOR FRAME. REPAIRED RT FWD EXIT DOOR FRAME IAW DASH 8 SRM 51-40-11 & RD 8-53-4940.SDR 39LA2014010849Support Angle · crackedRT VERTICAL SUPPORT ANGLE FOR RADAR CRACKED ON UPPER END. REPAIRED RT VERTICAL SUPPORT ANGLE FOR RADAR ON UPPER END IAW RD 8-53-7275.SDR CA140106004Housing · fractured(CAN) DURING THE FLIGHT CONTROL CHECK PRIOR TO TAKEOFF, THE CREW NOTED THAT THE LT OTBD ROLL SPOILER WAS NOT INDICATING ANY MOVEMENT ON THE PFCS INDICATOR. MAINTENANCE INVESTIGATION FOUND THE LT OTBD ROLL SPOILER ACTUATOR HOUSING FRACTURED AND LEAKING. THE ROSDR CA140120009Elt · false activation(CAN) ELT ACTIVATED WHILE ON GROUND, REASON UNKNOWN.SDR CA131227003Brake · overheated(CAN) TAKEOFF WAS REJECTED SHORTLY AFTER RELEASING THE BRAKES WHEN FLIGHT CREW WAS NOTIFIED BY THE TOWER OF SPARKS COMING FROM THE RIGHT BRAKES. A NEARBY AIRPORT VEHICLE REPORTED BRAKES GLOWING RED, EMERGENCY VEHICLES WERE REQUESTED. ON SCENE, FIRE DEPARTMENTSDR HNAA2013122300624Oil System · lowNR 1 ENGINE OIL PRESSURE WARNING LIGHT ILLUMINATED DURING TAKEOFF ROLL. ABORTED TAKEOFF AND REDUCED POWER. LIGHT EXTINGUISHED AND PRESSURE APPEARED NORMAL BEFORE ENGINE SHUTDOWN. CHECKED NR 1 ENGINE OIL LEVEL AND SERVICED WITH 2 OUARTS. INSPECTED, CLEANED ASDR CA131218018Control Unit · malfunctioned(CAN) DURING PRE-FLIGHT AUTOFEATHER/UPTRIM TEST, FLIGHT CREW REPORTED 154 PERCENT OF TORQUE ON THE NR 1 ENGINE. DECISION WAS TAKEN TO FEATHER THE PROPELLER AND RETURN TO GATE BUT LATER ATTEMPTS TO FEATHER THE PROPELLER CAUSED RAPID INCREASE OF TORQUE. FLIGHSDR CA131213002Connector · overheated(CAN) DURING SCHEDULED ROUTINE INSPECTION, THE LT APPROACH LANDING LIGHT WAS FOUND INOPERATIVE. DURING TROUBLESHOOTING, RELAY 3341-K1 MOUNTED ON RELAY PANEL NR 2 LOCATED IN THE WARDROBE BEHIND THE FLIGHT DECK WAS FOUND AT FAULT. VISUAL INSPECTION REVEALED SISDR CA131213004Actuator · cracked(CAN) PILOT REPORTED THAT LT OTBD ROLL SPOILER WILL NOT EXTEND BUT THE INBD IS OK. MAINTENANCE DISCOVERED THAT THE LT OTBD ACTUATOR HSG WAS CRACKED. THE ACTUATOR WAS REPLACED IAW THE AMM AND THE ACFT RETURNED TO SERVICE, PN A44700-009, SN 0186.SDR CA131216026Line · leaking(CAN) WHILE COMPLETING A MAINTENANCE INSPECTION FOUND HYDRAULIC LINE LEAKING FROM PIN HOLE ON THE AFTER VERTICAL SPAR. HYDRAULIC LINE REPLACED, AND CHECKED SERVICEABLE. ACFT RETURNED TO SERVICE.SDR CA131202007Autofeather Sys · malfunctioned(CAN) DURING THE TAKEOFF ROLL, NR 1 ENGINE PROPELLER AUTOFEATHERED UNCOMMANDED. THE TAKEOFF WAS ABORTED WITHOUT INCIDENT AND THE ACFT RETURNED TO THE GATE.SDR CA131202010Signal Cond Unit · malfunctioned(CAN) SHORTLY AFTER TAKEOFF, NR 2 ENGINE FEATHERED. FLIGHT CREW SHUTDOWN THE ENGINE AND DECLARED AN EMERGENCY. THE ACFT RETURNED AND LANDED WITHOUT FURTHER INCIDENT. FLIGHT CREW REPORTED 155 PERCENT TORQUE ON THE NR 2 ENGINE. FLIGHT DATA RECORDER WAS DOWNLOSDR CA131126009Actuator · fractured(CAN) CREW REPORTED LOSS OF BRAKE PRESSURE WITH THE SELECTION OF SPOILERS ALSO THE HYDRAULIC ISO VALVE LIGHT CAME ON. VISIBLE HYDRAULIC LEAK IN THE LT WING/NACELLE AREA. MAINTENANCE DISCOVERED THAT THE LT, INBD SPOILER ACTUATOR HOUSING WAS FRACTURED. THE ACTUSDR CA131120008Control Valve · faulty(CAN) AFTER LANDING THE CREW REPORTED THAT THE LT BRAKES SEEMED TO BE GLOWING AND THAT THE LT MAIN WHEELS WERE GOING FLAT. AT THE GATE, MAINTENANCE FOUND THE NR 2 MAIN WHEEL DEFLATED AND THE BRAKES VERY HOT. BOTH LT BRAKE UNITS AND WHEELS WERE REPLACED. AFTSDR CA131119001Arm · damaged(CAN) DURING ROUTINE INSPECTION THE RT MLG CENTER DOOR FWD HINGE ARM, PN 85420015-003 WAS FOUND WITH A DEEP NICK THAT WAS BEYOND LIMITS. THE HINGE ARM WAS REPLACED. RESULTING IN IN-FLIGHT LOSS OF THE DOOR.SDR CA131119002Arm · chafed(CAN) DURING ROUTINE INSPECTION THE RT MLG CENTER DOOR FWD HINGE ARM, PN 85420015-003 WAS FOUND WITH CHAFING WEAR BEYOND LIMITS. THERE ARE ALSO INDICATIONS THAT A CRACK MAY BE PRESENT. THE HINGE ARM WAS REPLACED. SDR IS BEING SUBMITTED AS WE HAD THIS, PN HINSDR CA131118022Control Panel · shorted(CAN) DURING THE DESCENT THROUGH 14,000 FEET TO THE DESTINATION AIRPORT THE CREW NOTICED A BURNING SMELL IN THE COCKPIT BUT NO NOTICEABLE SMOKE. THEY ACTIONED THEIR QRH AND TURNED THE ENGINE BLEED AIR OFF. THEY DONNED THEIR OXYGEN MASKS AND DECLARED AN EMERGENSDR CA131111007Seal · leaking(CAN) AFTER TAKEOFF THE CREW OBSERVED THE RT ENGINE LOW OIL PRESSURE WARNING LIGHT ILLUMINATE. THE CREW FOLLOWED THEIR QRH AND SHUTDOWN THE RT ENGINE. THEY DECLARED AN EMERGENCY AND RETURNED TO THE DEPARTURE AIRPORT FOR AN UNEVENTFUL LANDING. CONTRACT MAINTESDR CA131108001Bearing · seized(CAN) THE CREW REPORTED THAT THE LT MLG FWD DOOR WAS OPEN A LITTLE IN FLIGHT, HOWEVER COCKPIT INDICATION WAS NORMAL. MAINTENANCE INVESTIGATION FOUND THE AFT HINGE BEARING ON THE LT MLG FWD DOOR SEIZED. THIS PREVENTED THE DOOR FROM FULLY CLOSING OR OPENING. ASDR CA131022001Wire · chafed(CAN) DURING MAINTENANCE INSPECTION, 1 OF THE LT AC GENERATOR OUTPUT WIRES WAS FOUND CHAFED/SHORTING TO A FRAME NEAR THE LT AC CONTACTOR BOX CONNECTOR 2421-P29 NR 1 NACELLE. IT HAD BURNED A SIGNIFICANT NOTCH IN THE FRAME AT THE AREA OF CONTACT. A SEARCH OF TSDR CA131018004Transfer Tube · leaking(CAN) IN CRUISE, FLIGHT CREW RECEIVED A STEADY NR 2 ENGINE OIL PRESSURE WARNING MESSAGE AND OBSERVED A FLUCTUATING OIL PRESSURE. THE ENGINE NR 2 PROPELLER WAS FEATHERED AND THE OIL PRESSURE DROPPED EVEN MORE. THE ENGINE WAS SHUTDOWN AND AN EMERGENCY WAS DECLSDR CA131016002Fuel Heater · loose(CAN) FUEL HEATER HAS AN ACCESS PORT INBD THAT IS NOT USED ON THIS INSTALL AND A LOOSE METAL SHIPPING PLUG HAS FOUND INSTALLED INSTEAD OF THE REQUIRED STEEL MS9902-04 PLUG LOCK WIRED IN PLACE. THE LOOSE PLUG ALLOWED FUEL TO LEAK INTO THE LOWER COWL AND OUT THSDR CA131011003Pulley · seized(CAN) DURING ROUTINE MAINTENANCE, IT WAS NOTICED THAT THE FORCE REQUIRE TO OPERATE THE MLG ALTERNATE RELEASE HANDLE WAS HIGHER THAN NORMAL. TROUBLESHOOTING REVEALED THAT THE LT MLG FWD DOOR ACTUATOR END PULLEY WAS SEIZED. THE PULLEY WAS REPLACED AND THE SYS TSDR CA131009012Tscu · failed(CAN) DURING CLIMB, FLIGHT CREW REPORTED THAT THE NR 1 ENGINE TORQUE INDICATOR SURGED TO 152 PERCENT. AS THE FLIGHT CREW WAS EVALUATING THE SITUATION, THE NR 2 TORQUE STARTED TO FLUCTUATE. DECISION WAS TAKEN TO RETURN AND LAND. AN EMERGENCY WAS DECLARED AND TSDR CA131008004Actuator · cracked(CAN) DURING TRANSIT CHECK, HYDRAULIC LEAK FOUND DRIPPING FROM LT WING INBD AND OTBD CANOE FAIRINGS. LEAK WAS TRACED TO THE RT OTBD SPOILER ACTUATOR FROM THE PISTON SEAL. ACTUATOR WAS REPLACED AND SYSTEM BLED IAW AMM 27-14-05 AND 27-14-00. LEAK CHECKS WERE CSDR CA131004005Check Valve · fractured(CAN) SHORTLY AFTER TAKEOFF, FLIGHT CREW RECEIVED A NR 2 HYD ISO VALVE CAUTION MESSAGE AND NOTICED THAT THE HYDRAULIC NR 2 SYSTEM FLUID LEVEL HAD DEPLETED TO 0.5. INBOUND OF THE DESTINATION AIRPORT AN EMERGENCY WAS DECLARED AND AN ALTERNATE LANDING GEAR EXTENSSDR CA131002002Actuator · fractured(CAN) TAXING FOR TAKEOFF AND WHILE PERFORMING FLIGHT CONTROL CHECKS, FLIGHT CREW NOTICED THAT THEY HAD LOST THE NR 1 HYD SYS. ACFT TAXIED BACK TO THE GATE WHERE A HYDRAULIC LEAK WAS NOTICED UNDER THE RT WING. A MAINTENANCE TEAM TRAVELED TO THE OUTSTATION ANDSDR HNAA2013092700518Relay · malfunctionedREJECTED TAKEOFF DUE TO AUTO FEATHER FAILURE TO ARM. GROUND RAN ACFT, COULD NOT DUPLICATE. R & R ARM CONTROL RELAY 6121-K5 FOR POSITIVE MX ACTION. OPS CHECKED GOOD AT THIS TIME.SDR CA130927007Fitting · corroded(CAN) WHILE PERFORMING MAINTENANCE RELATED TO SB8-54-41, MODERATE CORROSION WAS WITNESSED IN THE BORE OF THE OTBD NACELLE TO REAR SPAR FITTING BETWEEN THE 2 HAT BUSHINGS. THE FITTING WAS REPLACED IAW THE APPROVED AMM/SRM REFERENCES. AC CYCLES: 63590, AC HOURSSDR CA131001004Line · chafed(CAN) DURING ROUTINE MAINTENANCE A FUEL LEAK WAS NOTED AT THE NACELLE DRAIN LINE. INVESTIGATION FOUND THE FUEL LINE AND MOTIVE FLOW LINE CHAFFING AT THE SPLIT WASHERS WITHIN THE SHROUD IN THE DRY BAY. THE 2 FUEL LINES AND ASSOCIATED HARDWARE WERE REPLACED. FSDR CA130927002Actuator · fractured(CAN) THE FLIGHT CREW REJECTED TAKEOFF AT 30 KNOTS WHEN THEY LOST NR 1 HYDRAULIC SYSTEM PRESSURE, THE RUD ISO CAUTION LIGHT ALSO ILLUMINATED. THE NR 1 HYDRAULIC RESERVOIR QTY WAS NEAR ZERO. MAINTENANCE INVESTIGATION FOUND THE RT INBD ROLL SPOILER ACTUATOR HOSDR CA130923002Strut · corroded(CAN) NR 2 ENGINE, OTBD LOWER ENGINE SUPPORT STRUT HAS CORROSION AND PITTING IN THE BORE AT THE LOWER ATTACHMENT POINT. STRUT REPLACED IAW AMM.SDR CA130923004Fitting · corroded(CAN) NR 1 NACELLE TO REAR SPAR, OTBD ATTACHMENT FITTING REMOVED DUE TO LEVEL 3 CORROSION. REPLACED WITH SERVICEABLE PART IAW APPROVED REF.SDR CA130923013Bracket · cracked(CAN) FLIGHT CREW REPORTED THAT THE MLG ALTERNATE EXTENSION HANDLE DID NOT RETRACT AFTER BEING PULLED. MAINTENANCE TROUBLESHOOTING REVEALED THAT THE LT ALTERNATE EXTENSION CABLE NACELLE TOP BRACKET ASSY WAS CRACKED AND THE CABLE OFFS THE PULLEY. FURTHER TROUB
Back to Pratt & Whitney Canada PW120A