Pratt & Whitney Canada PW127
Service difficulty reports · 996
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW127' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW127' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TRBA2010047Socket · burnedSTRONG BURNING SMELL INSIDE COCKPIT AREA AFTER T/O. RETURN TO MIA FOR PRECAUTIONARY LANDING. FOUND FLUORESCENT TUBE SOCKET AT 290LG BURNED AND MELTING. R & R SOCKET AND TESTED IAW ATR 72 JIC 33-21-23. ALL TEST OK. ACFT OK FOR RETURN TO SERVICE.SDR TRBA2010046Light · inoperativeFRONT HALF OF EMERGENCY LIGHTS IN-OP. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBA2010045Wire · brokenEMERGENCY EXIT LIGHT (BOTTOM ON SERVICE DOOR) INOPERATIVE. FOUND BROKEN WIRE AT PIN NR 1 OF EMER EXIT LT 68WL. RESECURED PIN IAW ASM 33-51-00 OPS CHK GOOD NO FURTHER DEFECTS NOTED.SDR TRBA2010044SUPFan · failedSTRONG BURNING ODOR FELT THROUGH OUT THE CABIN AND COCKPIT. NO SIGN OF HEAT SOURCE NOR SMOKE WAS IDENTIFIED. OPENED ALL OVERHEAD BINS AND INSPECTED FOR BURNING ODOR ALL ELECTRICAL COMPONENTS IAW JIC 25-24-21. ALSO OPENED ACCESS DOORS TO ELECTRONIC RACKS AND INSDR TRBA2010040Light · inoperativeTHE EMERGENCY EXIT LIGHT ON THE PASSENGER CABIN ENTRY DOOR IS INOPERATIVE. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010027Spar · corrodedLT WING FRONT SPAR BETWEEN ENGINE AND FUSELAGE CORROSION AROUND 2 LOCK FASTENER. OPENSDR TRBACPCP2010027SPSkin · corrodedLT WING FRONT SPAR BETWEEN ENG AND FUSELAGE 2 LOCK FASTERNERS SURROUNDING CORRODED. COMPLIED WITH LT WING LOWER SKIN CORROSION BLEND OUT IAW EO NR E2-5700-384 ( FWD SPAR RIBS 6 AND 7) DEFFERRED AS (ER TD,O AITJ NR 414570423. FOR FUTURE TOLERANCE INSP AND IAWSDR TRBA2010040SUPWire · brokenTHE EMERGENCY EXIT LIGHT ON THE PASSENGER CABIN ENTRY DOOR IS INOPERATIVE. REMOVED AND REPLACED BROKEN WIRE IAW MM STD PRACTICE 20-42-10 OPS CHECK GOOD.SDR TRBA2010038Light · inoperativeA PLASTIC OR ELECTRICAL BURNING ODOR IS COMING FROM THE FWD PART OF THE PASSENGER CABIN. R & R FLOURESCENT TUBE AT 2CD IAW JIC 33-21-23 RAI 10000-018 END.SDR TRBACPCP2010030Structure · corrodedDISCREP: REF AML 434552/4 - RT WING ELECTRO FUEL PUMP SURROUNDING AREA HAS CORROSION. AWAITING COMPLETION OF EO E2-57MR-385 AND AML PAGE.SDR TRBACPCP2010031Skin · unknownLT WING SKIN AROUND RIB 10 JACK PAD. AWAITING COMPLETION OF EO E2-57MR-387 AMD AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010032Skin · corrodedAN AREA OF CORROSION WAS FOUND AT LT WING LOWER SKIN AT T/E AT RIB 9. AWAITING COMPLETION OF EO E2-57MR-388 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010033Skin · corrodedAN AREA OF CORROSION WAS FOUND AT RT WING LOWER SKIN AT L/E BETWEEN RIBS 12-13. AWAITING COMPLETION OF EO E2-57MR-389 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010034Skin · corrodedAN AREA OF CORROSION WAS FOUND AT LT WING LOWER SURFACE AT T/E BETWEEN RIBS 11-12. AWAITING COMPLETION OF EO E2-57MR-390 AND AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010035SPSpar · damagedINSTALLED REPAIR DOUBLER AT RT WING LWR REAR SPAR IAW AE EO E2-57MR-395. REF ART W/O 11951 NRWC 334519, ART FORM L -004-2R1 AND AMS NDT REPORT 100514-13. THIS ACTION CLOSES TDMI 348570218.SDR TRBACPCP2010030SPStructure · damagedREPAIRED RT WING ELECTRO FUEL PUMP SURROUNDING AREA IAW EO E2 57-MR-385 REF AMS NDT REPORT 8/30 3H100505-70.SDR TRBACPCP2010031SPSkin · damagedLT WING LOWER SKIN PANEL JACK PAINT AT RIB 10 TEMPORARY CORROSION BLEND OUT REPAIR IAW EO E2-57MR-387 REF AMS NDT REPORT 8130-3 NR 100505-72. THIS ACTION CLOSES TDMI.SDR TRBACPCP2010032SPSkin · damagedLT WING LOWER SKIN PANEL AT T/E AT RIB 9. TEMPORARY CORROSION BLEND OUT REPAIR IAW AE-E0 NR E2-57MR-388, REF AMS-NDT-REPORT 8130-3 NR 100505-78.SDR TRBACPCP2010033SPSkin · corrodedACCOMPLISHED TDMI 3485102C8 RT WING AT RIB 13 LWR SURFACE FWD HAS CORROSION TEMPORARY REPAIR AT NEXT C-CHECK PENDING FINAL REPAIR EMBODIMENT OR REPAIR LIFE LIMIT 5 MONTHS IAW AE EO E2-57MR-389. REF AMS-NDT-REPORT 8130-3 NR 100505-73. THIS ACTION CLOSES.SDR TRBACPCP2010034SPSkin · corrodedACCOMPLISHED TDMI 348570288 LT WING LWR SKIN PANEL AT TE BTW RIBS 11-12 TEMPORARY CORROSION BLEND OUT REPAIR. EO E2-57MR-390, REF AMS-NDT-REPORT 8130-3 NR 100505-75.SDR TRBA2010035SUPO-Ring · leakingDURING CLIMB OUT WHEN SELECTING BLEED VALVE ON IN THE COCKPIT WE GET A NOXIOUS DIRTY SOCK EXHAUST SMELL. SMELL GOES AWAY WHEN DESELECTING NR 1 BLEED VALVE. R & R LT ENG NR 5, 6, 7 SCAVENGE TUBES O-RINGS IAW MM 72-01-50. NO SMELL NOTED AT THIS TIME, NO LEAKS.SDR TRBACPCP2010025Skin · corrodedCORROSION ON LT WING LOWER SKIN AT RIB 10 JACK POINT. PERFORMED TEMPORARY REPAIR LT WING LOWER SKIN AT RIB 10 JACK POINT FOLLOWING SRI INSTRUCTIONS UNTIL NEXT SCHEDULED C-CHECK WHEN A PERMANENT REPAIR WILL BE APPLIED IAW SRI DO/TS-2187/10-13360 ISSUE B AND EO SDR TRBACPCP2010026Skin · corrodedCORROSION ON LT WING LOWER SKIN AT FUEL MAG STICK. OTBD OF RIB 5 BTW STIFFENERS 5-6. PERFORMED TEMPORARY REPAIR LT WING LOWER SKIN AT FUEL MAG STICK OTBD OF RIB 5 BTW STIFFENERS 5-6. ATR HAS ADVISED THAT DAMAGE CAN REMAIN AS IS UNTIL THE NEXT SCHEDULED C-CHECSDR TRBA2010034Unknown · smokeELECTRICAL SMOKE INDICATION ON CAP. SMELL IN COCKPIT & CABIN. SMOKE SOURCE NOT IDENTIFIED. PERFORMED ENG RUN UP TO CHECK ELEC SMK INDICATION CAP PROB ON, COULD NOT DUPLICATED, ADJUSTED ACFT SYS LT PACK HOSE CLAMP, PERFORMED OPT CHECK, WORKING PROPERLY IAW 21SDR TRBA2010033Unknown · smokeRIGHT BEFORE LANDING, GEAR SELECTED DOWN ON FINAL APPROACH, AFT F/A SMELLED BURNING AND SMOKE APPEARANCE IN CABIN NEAR CEILING, TURN OFF RECIRC AND LANDED. AIR SEEM TO BE IMPROVED, ELECTED TO TAXI TO GATE , UNABLE TO FIND SOURCE OF SMOKE. COMPLIED WITH DVI OFSDR TRBACPCP2010020Structure · corrodedCORROSION FOUND ON LT WING FUEL PUMP SURROUNDING AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT FUEL PUMP CUT-OUT AREA IAW EO NR E2-57MR-376.SDR TRBACPCP2010021Skin · corrodedCORROSION FOUND ON LT WING FUEL DRAIN (INNER) SURROUNDING AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT FUEL DRAIN BTW RIBS 4-5 AREA IAW EO NR E2-57MR-377.SDR TRBACPCP2010022Skin · corrodedCORROSION FOUND ON LT WING JACKING POINT AREA. COMPLIED WITH LT WING, LOWER SKIN CORROSION BLEND OUT TEMPORARY REPAIR AT JACK POINT AT RIB 10 AREA IAW EO E2-57MR-378.SDR TRBA2010031Window · departedAPPROACHING AIRPORT AT APPROX 3000 FT HEARD LOUD BANG. F/A ADVISED WINDOW 11D WAS CRACKED. EMERGENCY DECLARED. UPON POST FLIGHT APPEARS FOLDABLE GEAR DOOR IS MISSING ON RT MAIN GEAR. REF TO NRWC NR314860 CABIN WINDOW 12D AND 11D WERE REPLACED AND PRESSURE CSDR TRBA2010029Lamp · failedEMERGENCY FLOOR PATH LIGHTING INOP AT PAX SEAT 10B. RELAMPED EMERGENCY FLOOR PATH LIGHT BULB IAW JIC NR 33-50-00.SDR TRBA2010027Lamp · burned outEMERGENCY LIGHTS (FLOOD LIGHTS) RT FUSELAGESE OUT. REPLACED FLOOD LIGHT RT FUSELAGE IAW MM 33-51-23.SDR TRBA2010028Lamp · weakEMERGENCY LIGHT (FLOOD LIGHT) LT FUSELAGE DIM. REPLACED LT FUSELAGE LIGHT OPS CK IAW MM 33-51-25.SDR TRBA2010025SUPSwitch · failedAFTER BOTH ENGINES SHORT F/A ADVISES EMERGENCY LIGHT ILLUMINATE. RAI EMERGENCY LIGHT SELECTOR SWITCH IAW STD PRACTICES NR 20-27-17. OPS CHECK OK.SDR TRBA2010026Lamp · burned outEMERGENCY EXIT LIGHT ON STAIRS 1S OUT. RELAMPED EMERGENCY LIGHT REF JIC 33-50-00.SDR TRBACPCP2010028Hinge · corrodedCORROSION RT WING INBD L/E HINGE BETWEEN RIB 4 AND 5. REMOVED CORROSION ON RT WING L/E HINGE BETWEEN RIB 4 AND 5 IAW SRM 57-12-10, COMPLIED WITH NR DO/TS-1754/10-13248, NR DO/TS-1754/10, 5667 AND EO E2-57MR-374.SDR TRBA2010024Power Supply · failedEMERGENCY LIGHT OUT FROM SEAT 14AB TO THE EMERGENCY SIGNS IN THE BACK OF THE CABIN. R & R POWER SUPPLY AND BATTERY FOR EMERG LIGHT IAW 33-51-21 EX 33-51-21, CYC 29580.SDR TRBA2010023SUPGround Wire · failedELECTRICAL SMOKE ODOR IN COCKPIT. R & R GPU GROUND CABLE 440VN IAW JIC NR 24-46-11.SDR TRBACPCP2010036Bulkhead · corrodedCORROSION ON CONTACT POINT AT FWD PRESSURE BULKHEAD. C/W SRI DO/TS-1767/10-13252, REF NDT REPORT AMS INC 100326-25 FOR UT AN HFEC VALUES. NO CRACKS NOTED AT THIS TIME. C/W ATR72 SRAS DO/TS - 1767/10 5668 SUPPLEMENTARY INSP, DUI OF BLENDED AREAS EVERY 2 YRS FORSDR CA100521001Connector · contaminatedIFSD DURING CRUISE, NP SPEED INCREASED SUDDENLY, WITH CORRESPONDING TORQUE DECREASE. ACFT LANDED IMMEDIATELY, UNEVENTFUL LANDING. SOME CONNECTORS WERE FOUND LOOSE AND FULL OF OIL. ON A SUBSEQUENT FLIGHT, THE SAME HAPPENED (HIGH NP, LOW TQ) BUT THIS TIME THESDR TRBA2010018Windshield · crackedCAPTAINS WHINDSHIELD CRACKED IN FLIGHT. REF. NRWC 314341, R & R CAPTS. WINDSHIELD IAW ATR JIC 56-11-00. OPS CHECKS GOOD.SDR TRBA2010011Warning Light · illuminatedWITH FLAPS AT 30 DEGREES, GOT MASTER WARNING FLAP UNLOCK. EMERGENCY DECLARED. OPS CK OF FLAP ASYMMETERY DETECTION SYS IAW JIC NR 27-51-00. ON GROUND, OPS CK GOOD.SDR TRBA2010013SUPBleed Valve · inoperativeAFTER BLEEDS ON DURING CLIMB, A STRONG ACIDIC ODOR FILLED THE COCKPIT AND THEN SLOWLY GOT BETTER ENROUTE. BOTH COCKPIT CREW EXPERIENCED FEELING OF LIGHTHEADEDNESS, TINGLING LIPS & FINGERS, BY THE TIME WE STARTED OUR DESCENT, AFTER TOUCHDOM THE SAME STRONG SMELSDR TRBACPCP2010017Skin · corrodedAREA OF CORROSION WAS FOUND AT RT WING LOWER SKIN AROUND JACK POINT AT RIB 10. CORROSION WAS BLENDED OUT IAW SRM 51-21-42 AND NDT ASSURING THERE IS NOT MORE CORROSION. CORROSION DOES NOT REACH ANY FASTENER SEATING, FASTENERS WERE NOT REMOVED. REF SRI NR DO/SDR TRBA20100009SUPSeal · leakingLT PACK INOP, UNABLE TO BRING DUCT TEMP BELOW 40 DEGREES C, DURING T-OFF & CLIMB, STRONG BURNED OIL SPELL ACCOMPANIED BY TOO WARM TEMP. RETURNED TO DEPARTURE. R & R LT AIR CYCLE MACHINE CLAMP IAW MM 21-11-51 AND PERFORMED OPS CHECK AND FOUND WORKING PROPERLYSDR TRBA2010007Wire · damagedEMERGENCY LIGHT BURNED OUT IN MAIN ENTRY STAIRS AND SHOWING CABLES. REPAIRED WIRES AT MAIN DOOR IAW STD PRACTICE 20-00-00 OPT IAW JIC 33-50-00.SDR TRBA2010006Rudder · jammedCAPTAIN REPORTED RUDDER JAMMED DURING APPROACH. EMERGENCY DECLARED AND ACFT ARRIVED SAFELY. C/A AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBACPCP2010015Structure · corrodedCORROSION AROUND LT WING LWR SURFACE BOOST PUMP BETWEEN RIBS 4-5. CORROSION REPAIRED IAW ATR SRI DO/TS-1229/10-13115, REF NDT REPORT AMS 100226-20 FOR HEFC AND UT RESULTS, COMPLIED WITH ANA/E/3684/2004/E-002 3038 ISSUE B. ACCOMPLISHED EO E2-57MR-370, SUPPLEMSDR TRBACPCP2010016Pressure Blkhd · corrodedCORROSION WAS FOUND ON THE FWD PRESSURE BULKHEAD IN ONE AERA OF THE WEB. REMOVED CORROSION IAW ATR SRI DO/TS-1189/10-13104, REF NDT REPORT AMS 100226-19 FOR HFEC AND UT RESULTS, COMPLIED WITH ATR SARAS DO/TS-1189-10...5623, C/W EO E2-53MR-236. NO SUPPLIEMENTSDR TRBACPCP2010014Bellcrank · corrodedLT OTBD WING AILERON CONTROL SEGEMENT CORRODED. REMOVED CORRODED SEGEMENT (BELLCRANK) LT OTBD WING INSTALLED LT OTBD SERVICABLE ROD (BELLCRANK) IAW JIC27-11-71. OPS CK GOOD.SDR TRBACPCP2010003Skin · corrodedLT FUEL ELECTRIC PUMP SURROUNDING SKIN CORRODED. BLENDED CORROSION AND TREATED IAW EO E2-57MR-366.
Back to Pratt & Whitney Canada PW127