SDR CA140218004Valve · failed(CAN) DURING CLIMB, THE SPOILER OTBD CAUTION LIGHT ILLUMINATED. ACFT RETURNED TO FIELD. MAINTENANCE REPLACED THE SPOILER UNLOAD VALVE, ACFT RETURNED TO SERVICE.SDR CA131216004Engine · power loss(CAN) THE PILOT REPORTED AN ENGINE UNCOMMANDED POWER DECREASE AND AFTER THE PILOT ADJUSTED TO A NEW POWER SETTING, THE PILOT REPORTED THE ENGINE WENT INTO OVERSPEED. THE PILOT ELECTED TO SHUTDOWN THE ENGINE AND PERFORMED AN UNEVENTFUL SINGLE ENGINE LANDING ATSDR CA131202013Sequence Valve · failed(CAN) DURING DEPARTURE PROCEDURES AFTER RETRACTING THE GEAR, THE CREW NOTICED THE RIGHT HAND AMBER GEAR DOOR ANNUNCIATOR LIGHT. CREW COMPLETED THE QRH CHECKLIST, THEN THE MANUAL GEAR EXTENSION, BEFORE RETURNING TO YUL. NO EMERGENCY WAS DECLARED. UPON ARRIVALSDR CA131129001Diode · burned(CAN) DURING ACCOMPLISHMENT OF TASK 000-24-210-120, MAINTENANCE REPORTED THAT CIRCUIT BREAKER WOW LOCATION M6 ON THE RT ESSENTIAL BUS IS POPPING WITH THE SELECTION OF THE BATTERY MASTER. MAINTENANCE CONFIRM THAT THIS IS A RESULT OF 2 BURNED, SHORTED DIODES INSDR CA131126013Wire · shorted(CAN) NR 2 AC GEN CAUTION ON LANDING. INITIAL RUN SHOWED NO LOAD ON NR 1 AC GEN BUSS, ALL THE LOAD WAS BEING HANDLED BY THE NR 2 GEN (INDICTATED AS 116 VOLTS ON ALL THREE PHASES ON NR 1 WITH LOAD OF 0.01, ON NR 2 VOLTAGE WAS 114 VOLTS WITH A LOAD OF 0.19 ON SDR CA131202005Oil System · low(CAN) THE PILOT REPORTED HIGH ENGINE OIL TEMP ON THE NR 2 ENGINE, 125DEGC FOR 10 SEC. THE PILOT SHUTDOWN THE ENGINE. THE ON GROUND INSPECTION REVEALED A LOW OIL LEVEL, A SUBSTANTIAL OIL LEAK ON THE REAR OF THE ENGINE NACELLE, EXHAUST AND EXHAUST STACK.SDR CA131126003Handle · unsecure(CAN) SHORTLY AFTER TAKEOFF, FLIGHT CREW RECEIVED THE DOOR WARNING LIGHT/FUSELAGE DOORS LIGHT ILLUMINATED. FLIGHT CREW RAN THROUGH CHECKLIST & DECIDED TO DECLARE A NON-EMERGENCY AIR RETURN. ATC WAS NOTIFIED. UPON LANDING, RAMP STAFF WAS WAITING FOR THE ACFSDR CA131126014Socket · shorted(CAN) WHEN REFUEL/DEFUEL DOOR IS OPENED THE BATTERY REFUEL CIRCUIT BREAKER RT DC PANEL M3 TRIPS, FOUND LT DUMP VALVE OPEN, LIGHT SOCKET SHORTED OUT RE-FUEL/DE-FUEL PANEL REPLACED, GROUND TESTED SERVICEABLE IAW AMM 28-30-00. REFUEL/DEFUEL INDICATOR, PN: 366-SDR CA140715005Pedal · stiff(CAN) F/O`S RUDDER PEDAL ADJUSTMENT VERY STIFF. WE ARE HAVING PROBLEMS WITH RUDDER PEDAL ADJUSTMENT VERY STIFF. WHEN THE PIVOT ARM IS REMOVED FROM THE SUPPORT TUBE WE ARE FINDING CONTAMINATION ON BOTH PARTS. IT LOOKS LIKE SOME SORT OF ANTI CORROSION COMPOUND TSDR CA131122004Control Unit · malfunctioned(CAN) NOSE WHEEL STEERING WENT TO CASTER BEFORE EXCEEDING 70` AND "NOSE STEERING" CAUTION LIGHT CAME ON. CARRIED OUT FIM 32-50-00-810-801. CARRIED OUT SCU FAULT RETRIEVAL IAW AMM 32-51-01-742-801. FOUND 2 FAULTS: 1 EVHS, 2 SCU. CLEARED FAULTS IAW AMM 32-51-0SDR CA131120013Cover · out of position(CAN) FWD PASSENGER AIRSTAIR DOOR WAS JAMMED AND COULD NOT BE OPENED, THE DECORATIVE COVER, FWD DRAFT BULKHEAD FWD LATCH COVER ASSY WAS CAUSING THE JAMMING. IT WAS REMOVED AND DOOR FUNCTION CHECKED SERVICEABLE IAW 52-11-00.SDR CA131115005Monitor · malfunctioned(CAN) DURING CRUISE, CREW RECEIVED A MASTER CAUTION FOR ENGINE ADP HEAT NR 2 CAUTION LIGHT, AND THE C/B WAS POPPED. AFTER LANDING THE CB WAS RE-SET AND OPS TEST OF THE NR 2 ENGINE AIR INTAKE ANTI-ICING SYS WAS PERFORMED IAW AMM 30-21-00-710-801 WITH NO FAULTSSDR CA131118010Gearbox · making metal(CAN) DURING REVENUE FLIGHT, ENROUTE THE PILOT REPORTED A LOSS OIL PRESSURE. ENGINE WAS SHUTDOWN. ACFT LANDED UNEVENTFULLY. ENGINE REMOVED FOR INVESTIGATION. REPORT AFTER INSPECTION SHOWS CHIPS IN THE TURBOMACHINE AND RGB CHIP DETECTORS. THIS IS BEING SENTSDR CA140214007Shaft · sheared(CAN) WHILE ON APPROACH WITH FLAPS SELECTED AT 15 DEGREES, THE NR 2 ENGINE HYD PUMP CAUTION LIGHT ILLUMINATED. HYDRAULIC QTY AND PRESSURE REMAINED NORMAL, UNEVENTFULL LANDING COMPLETED. MAINTENANCE REPLACED THE NR 2 ENGINE DRIVEN HYDRAULIC PUMP.SDR CA140715006Pivot · stiff(CAN) PROBLEMS WITH RUDDER PEDAL ADJUSTMENT VERY STIFF. WHEN THE PIVOT ARM IS REMOVED FROM THE SUPPORT TUBE WE ARE FINDING CONTAMINATION ON BOTH PARTS. IT LOOKS LIKE SOME SORT OF ANTI CORROSION COMPOUND THAT HAS MIGRATED AND MAKES THE ASSY VERY STIFF TO OPERATSDR CA140221017Pump · failed(CAN) AFTER T/O, DURING CLIMB, EDP CAUTION LIGHT FOLLOWED BY HYDRAULIC QUANTITY LOSS. CREW RETURNED TO BASE. EDP NR 2 FAILURE REPORTED, OPERATOR SENT TECHS AND PARTS TO BE REPLACED AFFECTED PUMPS AND FILTER PERFORMED SIMPLIFIED BLEED. ACFT HAS RETURNED TO SESDR CA140303016Isolation Valve · cracked(CAN) DURING SERVICING, MAINTENANCE FOUND RUDDER ISOLATION LEAKING. A HAIRLINE CRACK WAS FOUND ON THE BODY OF THE RUDDER ISOLATION VALVE.SDR CA131111022Wheel Half · cracked(CAN) DURING ROUTINE INSPECTION OF WHEEL TASK CARD DH4-32-48-32RP-801-SS WHILE UNDERGOING TIRE REPLACEMENT THE OUTER WHEEL HALF WAS FOUND CRACKED AT 7 LOCATIONS OF THE WHEEL SPOKES. CRACKED AREA WAS INSIDE THE WHEEL NOT VISIBLE FROM THE OUTSIDE THE WHEEL HALFSDR CA131112017Manifold · broken(CAN) REF: DISCARD HYD SYSTEM NR 3 FILTER ELEMENT AFTER CHANGING THE NR 3 HYD FILTER THE LEAK CHECK FAILED. REMOVED FILTER CUP AND THE FILTER MANIFOLD CHECK VALE AND 2 SPRINGS FELL OUT. NR 3 SYSTEM PRESSURE MANIFOLD, PN-945170-3 S/N-0778, REPLACED IAW TASK 2SDR CA131106005Duct · damaged(CAN) DURING INSPECTION, A HOLE WAS FOUND ON THE ELBOW PORTION OF THE COMPRESSOR CROSSOVER DUCT. THIS DUCT WAS LOCATED ON THE FORWARD SIDE OF THE AIR CONDITIONING PACK. FOR RECTIFICATION, THE DUCT HAD BEEN REPLACED. IPC REFERENCE 21-51-66, FIGURE 25, ITEM 10SDR CA131107002Pump · punctured(CAN) ON 5-NOV-2013, CAPTAIN REPORTED THE NR 2 HYD PUMP CAUTION LIGHT ON. FOLLOWING THIS, THE NR 2 HYD PRESSURE DROPPED TO 0 PSI AND ALL HYD QTY WAS LOST. THE ASSOCIATED CAUTION LIGHT ILLUMINATED. FLIGHT WAS DIVERTED. THE LANDING GEAR ALTERNATE EXTENSION WASDR CA131118011Gas Generator · burned(CAN) DURING REVENUE FLIGHT, PILOT OBSERVED AN ITT FLUCTUATION WITH ASSOCIATED NR 2 AC GEN, AC GEN HOT, ENG ADPT HEAT NR 2, NR 2 BLEED HOT". THE FLIGHT RETURNED TO AIRPORT OF ORIGIN. THERE WAS NO IFSD AND NO FIRE EXTINGUISHER USED. UPON INSPECTION OF THE RTSDR QXEA2013103101473Engine · overservicedSMOKE OBSERVED COMING FROM NR 1 ENGINE DRAIN MAST DURING ENGINE RUN AT GROUND IDLE. ADJUSTED OIL LEVEL IAW AMM 12-10-71-210-802. PURGED ECS DUCTS AS A PRECAUTION.SDR CA131031005Cover · melted(CAN) WHILE IN CRUISE, THE F/O WINDSHEILD HEAT CONTROL BOX STARTED TO SMOKE. THE CB B6 ON THE F/O CB PANEL WAS PULLED TO ISOLATE THE F/O WINDSHEILD HEAT. ONCE PULLED THE SMOKE SUBSIDED. MAINTENANCE HAS TAKEN THE ACFT TO THE HANGAR FOR FURTHER INVESTIGATION.SDR CA140221016Fadec · malfunctioned(CAN) WHILE ON GROUND AN ACFT WAS IN A CLEANING STA GETTING PREPARED FOR THE NEXT FLIGHTS (APU RUNNING), WHEN THE CLEANING AGENTS HEARD A HUGE BANG, SIMULTANEOUSLY THE APU DOORS SEPARATED AND FELL TO THE GROUND. APU FIREWALL, TAIL SECTION AND DOOR DAMAGE FOUNSDR CA140209003Valve · failed(CAN) POWERPLANT MESSAGE POSTED JUST PRIOR TO TAKEOFF. ACFT TAXIED BACK TO THE GATE. MAINTENANCE R & R THE P2.2 VALVE AND RETURNED THE ACFT TO SERVICE.SDR CA131025005Tire · deflated(CAN) DURING THE TAKEOFF IT WAS NOTICED THAT THE NR 3 MAIN WHEEL HAD GONE FLAT. THE ACFT RETURNED TO THE DEPARTURE AIRPORT. AN EMERGENCY WAS DECLARED FOR LANDING AND THE ACFT LANDED UNEVENTFULLY. THE NR 3 AND NR 4 MAIN WHEEL ASSEMBLIES AND BRAKE ASSEMBLIES SDR CA131022011Pump · failed(CAN) ON FLIGHT PD 270, AT ROUGHLY 300 FT ON APPROACH, THE NR 2 ENGINE HYD PUMP CAUTION LIGHT ILLUMINATED FOR APPROXIMATELY 2 SECONDS AND THEN WENT OUT. IT WAS THEN NOTICED THAT THE NR 2 HYDRAULIC QTY WAS STARTING TO DEPLETE, AT ROUGHLY 70 PERCENT AND DROPPINSDR CA131024002Indicator · malfunctioned(CAN) UPON ATTEMPT TO CENTER THE RUDDER, THE FLIGHT CREW REPORTED THAT THE RUDDER TRIM SWITCH BECAME UNSERVICEABLE SHORTLY AFTER DEPARTURE. UPON REFERRAL WITH MOC IT WAS DETERMINED THAT THE BEST COURSE OF ACTION WOULD BE TO RETURN AND HAVE IT SERVICED PRIOR TSDR CA131104020Engine · fluctuates(CAN) THE PILOT WAS REQUIRED TO USE EMERGENCY PROCEDURE DUE TO A TORQUE FLUCTUATION FROM THE NR 1 ENGINE. INVESTIGATION IS ONGOING.SDR CA131104021Engine · fluctuates(CAN) THE PILOT WAS REQUIRED TO USE EMERGENCY PROCEDURE DUE TO A TORQUE FLUCTUATION FROM THE NR 2 ENGINE. INVESTIGATION IS ONGOING.SDR CA140221015Electrical Box · failed(CAN) PILOT REPORT: ON GEAR RETRACTION: GEAR SELECTOR LIGHT FLASHING AMBER , RH MAIN GEAR UNSAFE RED WARNING. QRH CONSULTED. GEAR VERIFIED AS UP BOTH VISUALLY AND SECONDARY LIGHTS RETURN TO BASE. GEAR SELECTED DOWN SATIS PERFORMED TROUBLESHOOTING NO PRESENT FSDR CA131017011Pump · failed(CAN) NR 2 HYDRAULIC QTY LOSS AND RETURN TO BASE. NR 2 HYDRAULIC EDP CAUTION LIGHT CAME ON MOMENTARILY, NORMAL EXTENSION OF LANDING GEAR PERFORMED BEFORE TOTAL LOSS OF FLUID. NR 2 EDP REPLACED, ACFT RTS.SDR CA131104019Engine · overspeed(CAN) THE PILOT ELECTED TO SHUT THE NR 1 ENGINE DOWN DUE TO A PROPELLER OVERSPEED INDICATION. THE EMU DATA DOWNLOAD CONFIRMED THE OVERSPEED WITHIN ACCEPTABLE TOLERANCES FOR THE PROPELLER AND CONTROL SYSTEM. THE INVESTIGATION IS ONGOING TO DETERMINE THE ROOT SDR CA140209002Pcu · failed(CAN) DURING CLIMB PROP RPM INCREASED TO 1060 FOLLOWED BY THE NR 1 PEC CAUTION AND POWERPLANT MESSAGE. PROP WAS FEATHERED AND ENGINE SHUTDOWN. ACFT RETURNED TO FIELD AND AN UNEVENTFUL LANDING PERFORMED. MAINTENANCE REPLACED THE NR 1. PROP CONTROL UNIT (PCUSDR CA131017008Proximity Sensor · damaged(CAN) AFTER TAKEOFF THE UNDER CARRIAGE WAS SELECTED AND THE GEAR RETRACTED AND LOCKED NORMALLY. ALL LIGHTS EXTINGUISHED EXCEPT THE NOSE GEAR DOORS. THIS WAS RECOGNIZED AND THE CLIMB CONTINUED WITH DUE SPEED CONSIDERATION. ATC INFORMED AND A REQUEST TO ENTER SDR CA131017009Pump · failed(CAN) NR 1 HYD ISOLATION VALVE CAUTION LIGHT CAME ON ALONG WITH ROLL SPOILER INBD CAUTION AND NR 1 RUD HYD CAUTION LIGHT HYD QTY IS OK, PRESSURE WAS 0. MAINTENANCE REPLACED NR 1 EDP.SDR CA131011007Starter Gen · failed(CAN) SHORTLY AFTER TAKEOFF, FLIGHT CREW REPORTED AN AIR TURN BACK DUE TO A START SELECT LIGHT ILLUMINATING. AFTER STARTING THE LT ENGINE, THE STARTER DID NOT DISENGAGE. AFTER ROTATION, IT WAS NOTED THAT THE STARTER WAS STILL ENGAGED. FLIGHT CREW MANUALLY DSDR CA131008005Manifold · failed(CAN) AFTER LANDING AND VACATING RUNWAY, NOSE WHEEL STEERING FAILED WITH ASSOCIATED CAUTION. UNABLE TO STEER ONTO STAND WITH DIFFERENTIAL BRAKING SO SHUTDOWN ON TAXIWAY. SCU FAULT CODE SOVC, STEERING MANIFOLD REPLACED.SDR CA131008009Cover · cracked(CAN) NOSE GEAR PROXIMITY SENSOR COVER CRACKED SURROUNDING LT MOUNTING. DEFERRED FOR 50 FHRS IAW RD 8/4-32-0217. DAMAGED WOW SENSOR COVER REMOVED.SDR CA131009008Cover · broken(CAN) FOLLOWING RECEIPT OF ALL OPERATOR MESSAGE AOM NR 581 DATED 2 OCT 2013, THE NLG "COVER ASSEMBLY" WOW SENSOR, PN 47142-3, IPC 32-21-01, FIG. 1-100B, WAS INSPECTED AND FOUND BROKEN. THE COVER WAS REMOVED IAW RD84-32-0217. ACFT TSN 6285, CSN 4286.SDR CA131009013Connector · overheated(CAN) DURING CLIMB, FLIGHT/CABIN CREWS NOTICED A BURNING PLASTIC SMELL THROUGHOUT THE CABIN AND COCKPIT. DECISION WAS TAKEN TO RETURN AND LAND. AS THE ACFT TURNED BACK, CABIN CREW DEACTIVATED THE COFFEEMAKERS AND SMELLS DISSIPATED. AN EMERGENCY WAS DECLAREDSDR CA131007018Cover · broken(CAN) NLG WOW SENSOR COVER FOUND BROKEN, AFTER INSPECTION DUE TO SPECIAL AWARENESS RAISED BY AFTER MFG AOM MEMO 581. COVER REPLACED AND ACFT RELEASED FOR SERVICE.SDR CA131007023Cover · damaged(CAN) FOUND BOTH ATTACH TANGS BROKEN, REPLACED WITH NEW PART AND ACFT RELEASED FOR SERVICE.SDR CA131009007Cover · broken(CAN) THE NOSE LANDING GEAR WOW SENSOR COVER ASSEMBLY WAS INSPECTED AND FOUND BROKEN. THE COVER WAS REPLACED.SDR CA131007014Engine · malfunctioned(CAN) THE PILOT REPORTED THE ENGINE NR 2 HAD AN UNCOMMANDED POWER CHANGE. EVENT DETAILS ARE NOT AVAILABLE. THE CUSTOMER ENGINEERING OFFERED TROUBLESHOOTING ASSISTANCE TO PORTER.SDR CA131003005Nozzle · separated(CAN) DURING THE CLIMB, THE CREW HAD A LT ENGINE EMERGENCY FIRE WARNING AFTER ROTATION. THEY FOLLOWED EMERGENCY PROCEDURES AND AFTER SECURING THE ENGINE AND FIRING THE FIRST BOTTLE, THE FIRE WARNING WAS EXTINGUISHED. THEY DECLARED AN EMERGENCY AND LANDED WISDR CA131009006Cover · broken(CAN) THE NLG COVER ASSY WOW SENSOR WAS INSPECTED AND FOUND BROKEN. THE COVER WAS REPLACED.SDR CA140209001Skin · detached(CAN) ON LANDING AT DESTINATION AIRPORT, A PORTION OF THE LT INBD FLAP SHROUD WAS DISCOVERED DETACHED AND PEALING.SDR CA131001012Anti-Ice System · damaged(CAN) ENG ADPT HEAT 2 CL ON.HEATER CB POPS. (ENGINE INTAKE ADAPTER HEATER ASSEMBLIES) (RESOLVED ON W/O: 402704 TASKCARD: NR-00001) FOUND THE NR 2 ENGINE AIR INTAKE ADAPTER HEATER ELEMENT HAD SHORTED OUT.INSULATION FOAM MATERIAL FROM ADAPTER HEATER BLOWN OUT I
Back to Pratt & Whitney Canada PW150A