Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2013041700795Circuit Breaker · failed"PITOT HEAT STBY " CAUTION ILLUMINATED IN CLIMB. PITOT HEAT CIRCUIT BREAKER POPPED L7. RETURNED TO FIELD, LANDING UNEVENTFUL. REMOVED COCKPIT ENTRYWAY FLOORBOARD , INSPECTED WIRE BUNDLES FOR DAMAGE OR CHAFING, NO DEFECTS NOTED , DISCONNECTED CONNECTOR PLUG P4SDR CA130429008Transducer · faulted(CAN) AFTER ADVANCING THE POWER LEVERS ON THE R/W THE NR 1 PEC CAUTION ILLUMINATED AND THE POWERPLANT MESSAGE ILLUMINATED. THE T/O WAS REJECTED. THE ACFT WAS RETURNED TO STAND. TASK 61& 8722,20 & 8722,06 & 8722,810 & 8722,818 -FAULT CODE 260. SERVO CURRENT SDR CA130430015Outflow Valve · failed(CAN) DURING CRUISE AT FL200,. ALL PRESSURIZATION INDICATIONS WERE NORMAL UNTIL CREW NOTICED PRESSURE CHANGE IN CABIN. CABIN RATE OF CLIMB SHOWED +3000FT/MIN, CREW DECIDED TO USE OXYGEN MASKS, SHORTLY AFTER "CABIN PRESS" WARNING LIGHT ILLUMINATED. CREW CONDUCTSDR CA130419006Line · leaking(CAN) HYDRAULIC SYSTEM NR 1 LEAK FOUND, WHICH WOULD HAVE LED TO COMPLETE LOSS OF NR 1 HYD SYSTEM, FURTHER INVESTIGATION REVEALED A FLEXIBLE LINE END FITTING WAS LOOSE, IMPROPERLY CRIMPED TO THE LINE, HOSE WAS REPLACED.SDR CA140716001Pivot · stiff(CAN) RUDDER PEDAL ADJUST MECHANSIM POOR OPERATION ATA CHAPTER - 2720 RUDDER & TAB ACTION TAKEN/COMMENTS - CREW REPORTED RUDDER NOT CENTRING. RUDDER PEDAL ADJUST MECHANISM INSPECTED AND FOUND TO BE STICKING AND NOT FREE/SMOOTH IN OPERATION. 6)L/H PEDAL PISDR CA130412015Valve · failed(CAN) DIVERTED DUE TO RT OTBD STABILIZER L/E DEICE BOOT WOULD NOT DEFLATE. ACFT WAS INBOUND THAT WAS EXPERIENCING ICING CONDITIONS. ACFT MAINTENANCE TROUBLESHOT THE ACFT REPLACED THE VALVE-DUAL HEAT, PN 4100S005-04, SN 3237, REPLACE WITH 4100S005-04, SN 310SDR CA130410011Oil System · cracked(CAN) DURING CRUISE AT 21,000 FT, RT WINDSHIELD CRACKED. CREW DECIDED TO RETURN TO THE BASE. THE ACFT LANDED UNEVENTFULLY. THIS WINDSHIELD WAS INSTALLED ON 6TH APR FOR WINDOW HEATING SYSTEM TROUBLESHOOTING.SDR CA130410001Pin · disengaged(CAN) FLIGHT CREW REPORTED THAT EVEN WITH THE LOCK ISOLATED, GUARDED SWITCH SELECTED, THE FORTIFIED FLIGHT COMPARTMENT DOOR WAS STILL LOCKING ITSELF. MAINTENANCE FOUND THE LATCH RELEASED MECHANISM PIVOT PIN PARTIALLY DISENGAGED DUE TO A MISSING COTTER PIN. THSDR QXEA2013040400752Frame · corrodedFRAME BS 547, FLANGE DOUBLER IS CORRODED STR 24P. REMOVED FLANGE DOUBLER IAW SRM 51-42-05-02-01, REV 12. FOUND TO BE OUT OF LIMITS IAW SRM 53-30-15-00-01, REV 12. INSTALLED NEW CLEAT AND REINFORCING ANGLE IAW SRM 51-42-05-02-01 REV 12.SDR CA140303014Pump · failed(CAN) NR 2 HYD FLUID HOT LIGHT ILLUMINATED. THEREAFTER NR 2 HYD PRESS STARTED DECREASING, NR 2 HYD CAUTION LIGHT CAME ON AND HYD QUANTITY DECREASING. RECEIVED AN PTU IAW QRH THEREAFTER HYD QUANTITY WENT BELOW 25 PERCENT & PTU FAIL LIGHT. HYD QTY AND PR WENT SDR CA130416009Valve · leaking(CAN) THERE WAS A REPORTED OIL ODOR AND MIST IN CABIN DURING DESCENT. THE ACFT LANDED NORMALLY AT DESTINATION. POST FLIGHT INSPECTION REVEALED OIL WAS COMING OUT FROM THE P2.2 VALVE PORT.SDR CA130412016Flow Divider · failed(CAN) ENGINE 2 START SELECTED, NO FUEL FLOW INDICATION IN FLIGHT DECK SO START ABORTED. GROUND CREW NOT ON HEADSET BUT RECEIVED NO ABNORMAL HAND SIGNALS. SECOND START ATTEMPT MADE WITH SAME RESULT. AFTER PHONE CALL, THIRD START ATTEMPT MADE USING GROUND POWESDR CA130412012Brush Block · shorted(CAN) DURING CRUISE FLIGHT THE PILOT SELECTED PROP DEICE ON AND GOT BOTH AC GEN CAUTIONS AND BOTH DROPPED OFF LINE. HE SELECTED PROP DEICE OFF AND RESET THE GENS IAW HIS CHECK LIST AND THE GENS CAME BACK TO NORMAL. AG GEN ISSUE, FOUND AND VERIFIED SHORTED NR SDR QXEA2013032800688Stringer Clip · corrodedSTRINGER 24S CLIP IS CORRODED AT STA 449.5. STRINGER CLIP AT 24S STA 449.5 IS CORRODED OUT OF LIMITS IAW SRM 53-30-03-00-01, REV 12. STRINGER CLIP WAS REMOVED IAW SRM REV 12, 51-42-05-02-01. RECEIVED NEW PART AND MATCH DRILED TO AC IAW SRM REV 12, 51-40-07-0SDR CA130401024Connector · corroded(CAN) FLIGHT DECK ELT TRANSMISSION LIGHT ILLUMINATED. ELT TURNED ONFF AND DEFERRED. ELT CONNECTOR 2560-P1, PN 126-223 SOCKET A, FOUND CORRODED AND ALMOST BROKE IN HALF.SDR CA130412011Actuator · failed(CAN) FLAP DRIVE CAUTION LIGHT ILLUMINATED WHEN FLAPS MOVING TO 0. FLAPS STOPPED AT 10. MULTIPLE ROLLER AND TRACK DAMAGE FOUND. RT NR 2 FLAP ACTUATOR REPLACED.SDR CA130401017Oil System · overtemp(CAN) DURING T/O ROLL, THE CREW OBSERVED A FLUCTUATING OIL TEMPERATURE, BETWEEN 40 C AND 50 C. THE T/O WAS ABORTED. TROUBLESHOOTING FOUND NO PROBLEMS. THE DOWNLOAD OF THE ENGINE MONITORING UNIT SHOWED NO TEMPERATURE DROP. THE FADEC AND OIL TEMPERATURE SENSORSDR CA130412009Uplock · worn(CAN) LT MLG DID NOT INDICATE DOWN AND LOCKED WHEN GEAR SELECTED DOWN. ALT GEAR EXTENSION PERFORMED. BOTH MLG UPLOCKS WORN BEYOND LIMITS. LT GEAR WAS WORN TO 0.75MM.SDR CA130412008Flow Valve · failed(CAN) AFTER BLEEDS OFF TAKEOFF, ACFT FAILED TO PRESSURIZE IN AUTO OR MANUAL. MAINTENANCE DISCOVERED NO BLEED FLOW FROM APU OR ENGINES. TRACED TO A FAULTY PFCSOV WHICH WAS REPLACED.SDR CA130328001Oil System · low pressure(CAN) IN-FLIGHT, NR 2 ENGINE OIL PRESSURE WARNING CAME ON, PRESSURE WAS CONFIRMED LOW AND ENGINE SHUTDOWN. AFTER LANDING, INVESTIGATION REVEALED MAIN OIL FILTER WAS CLOGGED WITH METALLIC DEBRIS. THIS IS STILL UNDER INVESTIGATION AS TO THE SOURCE OF METAL. ESDR CA130328002Hydraulic System · contaminated(CAN) AFTER AN ENGINE SHUT DOWN DUE TO LOW ENGINE OIL PRESSURE, HYDRAULIC POWER TRANSFER UNIT FAILED TO PRESSURIZE THE NR 2 HYD SYSTEM, EMERGENCY LANDING GEAR EXTENSION PERFORMED AND AC LANDED SAFELY. THIS IS STILL UNDER INVESTIGATION, HYDRAULIC SYSTEM FLUID SDR CA130401006Engine · making metal(CAN) CUSTOMER ADVISED THE MAIN OIL PRESSURE WAS FLUCTUATING 20 MIN INTO THE FLIGHT. THE OIL PRESSURE STARTED TO DROP TO 47 PSI THEN THE PILOT ELECTED TO SHUTDOWN AND SECURE THE ENGINE. THE TROUBLESHOOTING FOUND BOTH ENGINE OIL FILTERS WERE CLOGGED WITH BRONZSDR CA130319003Steering Sys · erratic(CAN) FLIGHT CREW FROM ACFT, SN 4372, REPORTED PERSISTENT ERRATIC STEERING. MAINTENANCE CREW OF ACFT, SN 4372 REPORTED DURING PUSH FROM THE GATE THAT THE STEERING SYS WAS ARMED AND THE NOSE WHEEL TURNED IMMEDIATELY HARD LT, APPROXIMATELY 70 DEGREES, FLIGHT WSDR CA130319005Wire Harness · burned(CAN) LT AOA VANE CB TRIPPED, INTAKE 1 CB TRIPPED, LT SCREEN HT CB TRIPPED, NR 1 AUXILIARY FUEL PUMP CB TRIPPED, WIRING CHECKS REQUIRED. WINDSHIELD HEAT CAUTION AND STICK PUSH FAIL WITH RELATED CB`S TRIPPED AND BURNING ODOR ELECTRICAL HARNESS FOUND WITH BURNSDR CA130412006Pump · failed(CAN) ON PASSING APPROXIMATELY 12000 FT ON CLIMB TO CLEARED LEVEL OF FL220, 1 HYD FLUID HOT, CAUTION LIGHT ILLUMINATED. QRH CONSULTED, APPROXIMATELY 5 MINUTES LATER, THE 1 ENG HYD PUMP, FOLLOWED BY NR 1 HYD ISO VALVE, ELEVATOR PRESS AND HYDRAULIC SHUTOFF VALSDR QXEA2013031200581Engine · malfunctionedNR 2 ENGINE OIL PRESSURE WAS AEE AT IE THEN STARTED DROPPING FOLLOWED BY MASTER WARNING OIL TEMP REMAINED NORMAL. LT ENGINE RUNNING PRESSURE STABALIZED AT 15 PSI. ON APPROACH NR 2 PROP STARTED TO ROLL BACK ON THREE OCCASIONS. OIL PRESSURE DROPPED TO ABOUT 3SDR CA130411018O-Ring · damaged(CAN) NR 2 OIL PRESS ERRATIC THEN DROPPED AND WARNING LIGHT CAME ON. OIL PRESSURE STABILIZED AT 15 PSI AND THE PROPELLER RPM ROLLED BACK 2 DURING APPROACH. DURING TAXI IN, OIL PRESSURE DROPPED TO 3 PSI AND THE ENGINE WAS SHUTDOWN. THE NR 2 OIL PRESSURE LIGHSDR CA130312002Windshield · cracked(CAN) THE OUTER PANE OF THE LT WINDSHIELD SHATTERED IN CRUISE FLIGHT AT FL 240. THE CREW DESCENDED TO FL 140 AND CONTINUED TO THEIR DESTINATION. THE LT WINDSHIELD WAS REPLACED. LEFT WINDSHIELD, PN NP-157901-19, SN 11164H1273. ACFT & LT WINDSHIELD TSN 4059, CSDR CA130308001Bearing Race · corroded(CAN) BLADE WAS REMOVED SERVICEABLE FROM A HUB THAT WAS DUE FOR O/H. DURING INSTALLATION ONTO A SERVICEABLE HUB, TSO 0, THE LOCKING CABLE ASSY COULD NOT BE INSERTED DUE TO HIGH RESISTANCE. BLADE WAS DISSASSEMBLED TO INSPECTE THE SLEEVE INTERNAL AREA FOR POSSSDR CA130306001Engine · fire(CAN) PRELIMINARY, THE ACFT HAD NR 2 ENGINE FIRE WARNING AFTER TAKEOFF. BOTH BOTTLES WERE DISCHARGED. AFTER LANDING, THERE IS EVIDENCE OF AN ENGINE FIRE IN NR 2 ENGINE. FIRE WARNING AT 20,000 FT, 47 PASSENGER ON BOARD. PASSENGER DEPLANED ON RUNWAY. NO SMOKESDR QXEA2013030500537Engine · fireACFT FIRE WARNING INDICATION ON NR 2 ENGINE AT 20,000. ENGINE SHUTDOWN INFLIGHT. FIRE BOTTLES USED. FIRE WARNING REMAINED ON AFTER BOTH BOTTLES USED. LANDING UNEVENTFUL. FIRE DAMAGE NOTED IN NACELLE AFTER LANDING. OPENSDR CA130311010Engine · fire(CAN) AN ENGINE FIRE WARNING WAS ANNUNCIATED ON THE RT 2 ENGINE, APPROXIMATELY 20 MINUTES AFTER DEPARTURE. THE CREW SECURED THE ENGINE AND DISCHARGED BOTH FIRE BOTTLES, RETURNING TO DEPARTURE. A SINGLE ENGINE LANDING WAS UNEVENTFUL. IT WAS REPORTED THAT A LOSDR QXEA2013030400547Wire Harness · damagedCHAFE DAMAGE ON RT ENGINE WIRE HARNESS, LOCATED FWD END OF F4 EMS STRUT. INSPECTED, CHAFE DAMAGE IS TO OUTER WIRE WRAP ONLY, NO DAMAGE TO INNER WIRE NOTED. WRAPPED WIRES WITH FIBERGLASS TAPE IAW WM CHAPTER 20-12-10-201, REV 39.SDR CA130304012Wire Harness · chafed(CAN) DURING TROUBLESHOOTING OF AN INOPERATIVE GALLEY OVEN, SEVERE DAMAGE WAS FOUND TO A WIRE BUNDLE AT THE LT INBD WING REAR SPAR, AT WING STATION YW117,20. DAMAGE HAS APPARENTLY STARTED WITH CHAFED WIRE INSULATION AND HAS PROGRESSED TO AN OVERHEAT DAMAGE OFSDR CA130305002Blowout Panel · dislodged(CAN) CREW REPORTED A LOUD BANG DURING CLIMBOUT WHILE DEPARTING. RETURNED TO WITHOUT INCIDENT. MAINTENANCE FOUND THE AFT BAGGAGE BLOWOUT PANEL POPPED OUT, SAME PANEL WAS RESECURED AND PRESSURIZATION RUN CONDUCTED IAW AMM 21-31-00-720-801, RESULTING IN A NO SDR CA130304016Proximity Sensor · failed(CAN) AFTER CLIMBING OUT FROM RUNWAY 26, THE CAPTAIN DETECTED THE NLG AMBER LIGHT REMAINED ILLUMINATED. WITH THE LDG GEAR INOPERATIVE. ILLUMINATED, THE CAPTAIN SPOKE WITH MAINTENANCE AND THE F/O & THEY THEN ELECTED TO RETURN TO DEPARTURE. ACFT HAD A VISUAL ANSDR CA130411016Wire · broken(CAN) DURING CLIMB, THE AFT BAGGAGE DOOR INDICATED OPEN. MAINTENANCE FOUND DOOR LOCK SENSOR WIRE BROKEN AT DOOR HINGE AREA. THE WIRE WAS REPAIRED.SDR CA130314002Wire · damaged(CAN) RIGHT SIDE MAIN GEAR DOORS DID NOT CLOSE AFTER GEAR RETRACTION. CREW COMPLETED ALTERNATE EXTENSION. ACFT RETURNED TO FIELD WITHOUT INCIDENT. AN ELECTRICAL SHORT, SHORTENED WIRE BEHIND THE BACKSHELL OF CONNECTOR 3261-P54, TO RT SOLENOID SEQUENCE VALVE,SDR CA130314007Wire · broken(CAN) DURING CLIMB AFT BAG DOOR INDICATED OPEN. MAINTENANCE FOUND DOOR LOCK SENSOR WIRE BROKEN AT DOOR HINGE AREA. WIRE REPAIRED.SDR CA130228007Bypass Valve · failed(CAN) AFTER TAKEOFF AT APPROXIMATELY 15000 ASL, THE OIL TEMP ON THE NR 2 ENGINE INDICATED 105 DEGREES. IAW QRH POWER WAS REDUCED BY 20 PERCENT AND TIMER WAS SET TO MONITOR THE TEMPERATURE. TEMPERATURE WENT TO 126 DEGREES THE ENGINE WAS SHUT DOWN AS PER QRH. EMSDR CA130311008Oil System · overtemp(CAN) NR 2 ENGINE MOT WENT TO A MAX TEMP OF 127.8 C, AREA B FOR 666 SECONDS AND AREA D FOR 261 SECONDS IAW MM. THE CAPTAIN REDUCED THE TORQUE DOWN TO 68 PERCENT WHEN OIL TEMP WENT ABOVE 100 C. THE ENGINE WAS SHUTDOWN IN FLIGHT AT A MOT INDICATION OF 126C. SUSDR CA130225015Bearing · damaged(CAN) DURING WALK AROUND, FLIGHT CREW, NOTICED EXCESSIVE GREASE STREAKING ON LT OTBD AILERON ASSY ACTION. MAINTENANCE TOOK AIRCRAFT OUT OF SERVICE AND AFTER THOROUGH INSPECTION TO THE AILERON AREA IT WAS FOUND THAT THE LT OTBD AILERON HINGE BEARING HAS FAILEDSDR CA130228004Control Unit · failed(CAN) THE ACFT HAS EXPERIENCED SEVERAL UN-COMMANDED STEERING EVENTS BEGINNING ON 7 JAN 2013. THE DEFECT HAS BEEN INTERMITTENT IN NATURE WHICH HAS HAMPERED TROUBLESHOOTING EFFORTS. DURING THE FIRST EVENT ON 7 JAN 2013, THE ACFT VEERED TO THE LT AFTER LANDING SDR CA140221013Bracket · worn(CAN) PILOT REPORTED EXCESSIVE GREASE STREAKING FROM LT AILERON DRAIN HOLE NEAR THE TIP. MAINTENANCE WAS CALLED AND INVESTIGATED THE OUTBOARD NR 4 AILERON HINGE NEAR THE DRAIN HOLE AND BY VISUAL INSPECTION, COULD NOT SEE ANY ATTACHMENT HARDWARE INSTALLED AT THSDR CA130311012Actuator · malfunctioned(CAN) RT MLG UNLOCKED LIGHT REMAINS ILLUMINATED ON RETRACTION, GEAR RETRACTS AND DOORS CLOSE. DOWN AND LOCKED INDICATION OK. RETRACTION ACTUATOR REPLACED. GEAR FUNCTION CHECKED. ACFT RETURNED TO SERVICE.SDR CA130314006Bypass Valve · failed(CAN) DURING CLIMB PASSING 16,000 OIL TEMPERATURE ON THE NR 2 ENGINE WAS INDICATING 107 DEGREES AND CONTINUE TO CLIMB TO 113 DEGREES. THE TIMER WAS STARTED AT WHEN THE TEMP WAS RECOGNIZED AT 107 DEGREES AFTER THE E/A CHECKLIST WAS COMPLIED WITH AND POWER REDUSDR CA130225017Latch · failed(CAN) THE UNLOCKING OF THE AFT BAGGAGE DOOR HANDLE TRIGGERS THE FUSELAGE DOORS WARNING LIGHT WHICH RESULTED IN THE AIR TURNBACK OF PO 682. DOOR AFT CARGO INDICATOR CAME ON UPON ROTATION FORCING ACFT RETURN, DOOR HANDLE FOUND OPEN/UNLOCKED. RESET DOOR AND FOUNSDR CA130314005Solenoid Valve · intermittent(CAN) ON APPROACH GEAR SELECTED DOWN BOTH MAINS EXTENDED AND LOCKED DOWN WITH GREEN ILLUMINATED. NLG DID NOT EXTEND. NO AMBER DOOR LIGHT EVIDENT, DOORS DID NOT OPEN. NLG RED ILLUMINATED ON THE LANDING GEAR CONTROL PANEL. GO-AROUND CONDUCTED, ALTERNATE EXTENSDR CA130312012Line · failed(CAN) AS WE DESCENDED THROUGH 4000 ON APPROACH TO LAND, NR 2 HYD SYS FAILED. TOTAL LOSS OF NR 2 HYDRAULIC FLUID. A VISUAL MISSED APPROACH CONDUCTED AND WE HELD VISUALLY EAST, WHILE QRH CHECKLIST CARRIED OUT. ALTERNATE GEAR EXTENSION CARRIED OUT IAW QRH. RSDR CA130314003Control Unit · failed(CAN) FLAP POWER CAUTION ON APPROACH. FLAPS STUCK AT SLIGHTLY BEYOND 15 DEGREES. ENGINEERS INTERROGATED CDS WITH NO FAULT CODES. FLAP NVM RESET COMPLETED AND OPS CHECK OF THE FLAPS COMPLETED WITH NO FAULTS. FLAP CONTROL UNIT REPLACED.
Back to Pratt & Whitney Canada PW150A