Pratt & Whitney JT8D series
Service difficulty reports · 1,122
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM88041103Apu · leakingATB, SMOKE IN THE CABIN AFTER T/O AFT LAV SMOKE DETECTORS WENT OFF. NO SMOKE NOTED IN LAVS OR AFT CABIN. REPLACED APU AND PERFORMED DUCT BURNOUT.SDR GTIA040858Filter · cloggedORF - FLT 379 - RIGHT OIL STRAINER CLOGGING LIGHT CAME ON DURING TAKEOFF, DIVERTED TO ORF. REMOVED OIL FILTER AND FOUND CLOGGED FILTER, INSTALLED NEW OIL FILTER AND SECURED. PERFORMED ENGINE RUN UP WITH CREW. REMOVED OIL FILTER AND INSPECTED FOR CONTAMINENTSDR GTIA040854Fan Blade · damagedLP NR 281042-3; UPON INSPECTION, AFTER AIRCRAFT RETURNED TO THE GATE, FOUND NR 2 ENGINE C-1 (6 EA) FAN BLADES CURLED. REMOVED AND REPLACED NR 2 ENGINE.SDR GTIA040831Shaft · shearedAIR RETURN DUE TO LOSS OF LT SYSTEM HYDRAULIC PRESSURE. REMOVED AND REPLACED NR 1 ENGINE HYDRAULIC PUMP, NOTED SHEARED SHAFT. LEAK AND OPS CHECK GOOD.SDR C7WA200400064Landing Gear · lack of lubeNOSE LANDING GEAR FAILED TO EXTEND NORMALLY. RED NOSE GEAR UNSAFE LIGHT ON. MANUALLY LOWERED NOSE LANDING GEAR IAW AOM VOL 1. INSPECTED NOSE GEAR ACTUATOR, LOCKING ACTUATOR AND LINKAGE NO DAMAGE NOTED. LUBRICATED NOSE GEAR TRUNNIONS, ACTUATOR AND DRAG BRACSDR GTIA040823Lanyard · disconnectedR1 DOOR EMERGENCY SLIDE LANYARD DISCONNECTED. SECURED R1 DOOR EMERGENCY SLIDE LANYARD, OK FOR SERVICE.SDR GTIA040827Line · rupturedDURING CLIMB, LT HYDRAULIC QTY WENT TO 3 PRESS 0, LT HYD PRESSURE LOW ANNUN, DID QRH CHK LIST. FOUND LT ELEVATOR POWER CONTROL HYDRAULIC LINE RUPTURED NEAR UNION AT THE CONTROL VALVE, REMOVED AND REPLACED RUPTURED LINE. AIRCARFT TAIL SWAP WITH N814NK.SDR GTIA040826Solenoid · stuckLP 0264638; ON PRE-FLIGHT FOUND FLIGHT DECK AUDIO ALERTING CHIME INOPERATIVE. FOUND COCKPIT CHIME BELL SOLENOID STUCK AND SHORTING TO GROUND, REMOVED AND REPLACED COCKPIT CHIME BELL. AIRCRAFT TAIL SWAP WIGH N812NK.SDR GTIA040824Actuator · malfunctionedRUDDER TRIM HAS 6 UNITS RT TO MAINTAIN STRAIGHT AND LEVEL. FOUND YAW DAMPER ACTUATOR OUT OF MOUNTS. REMOVED AND REPLACED YAW DAMPER ACTUATOR, OPS CHECK NORMAL.SDR DLM88040984Turbine · failedSMOKE ODOR IN THE CABIN. REPLACED APU FOR LEAKAGE.SDR GTIA040817Handle · unsecureL1 DOOR HANDLE LOOSE. SECURED DOOR HANDLE ON DOOR IAW MD-80, MM 52-61-00. OPS CHECK GOOD.SDR GTIA040804Connector · brokenLT ENGINE LOOP B ILLUMINATED AT CRUISE. FOUND CONNECTORS INNER INSULATOR BROKEN. REMOVED AND REPLACED B LOOP CONNECTOR, LOWER CENTER.SDR DLM88040948Apu · smokeAPU CAUSED SMOKE IN THE CABIN AFTER LANDING IN LGA WITH LAV SMOKE DETECTOR GOING OFF. FOUND APU LEAKING OIL INTO INLET. PERFORMED PNEUMATIC SYSTEM DUCT BURN OUT OPN 5089. ALL NORMAL NO SMOKE OR ODOR IN CABIN, ALSO DEF APU PER MEL 49-00-01A.SDR ASMF200409013Control Panel · failedAIRCRAFT RETURNED TO PLATFORM, CONFIGURATION AUDIBLE ALARM WAS ACTIVATED AND AUTO SPOILER FAIL LIGHT WAS DEFERRED BY MEL. TAKEOFF CONFIGURATION WAS CHECKED BEING CORRECT. DURING OVERNIGHT SERVICE AUTO SPOILERS AND CONFIGURATION ALARM WERE CHECKED. AUTO BRAKE SDR WX0400035Brake Assy · overheatedAFTER DEPARTURE AT 10000 FT AGL F/O WAS HAND FLYING AIRCRAFT AND REPORTED TO CAPTAIN THAT PRIMARY TRIM SWITCHES ON BOTH CONTROL WHEELS FAILED. CAPTAIN TRIED YOKE SWITCHES AND SUITCASE HANDLES ON PEDESTAL, NEITHER WORKED. CAPTAIN CHECKED ALTERNATE TRIM SWITCHESDR WX0400036Battery Pack · inoperativeMAINTENANCE REPORTED OVERHEAD EMERGENCY LIGHTS, ROW 31 TO 35 AND EMERGENCY POWER OVERHEAD LIGHTS, ROW 25, 29 AND 33 INOPERATIVE. MAINTENANCE REPLACED BATTERIES IN BATTERY PACK IAW 33-53-00. LIGHTS ROW 31 TO 35 OPERATIONALLY CHECK GOOD. MAINTENANCE REPLACEDSDR 0WX0400034Power Supply · inoperativeMAINTENANCE REPORTED OVERHEAD EMERGENCY LIGHTS BETWEEN ROWS 31 AND 35 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY IAW MM REF 33-53-01. SYSTEM OPERATIONALLY CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR AALA20040990Pump · inoperativeDEN - INFLIGHT ON INITIAL CLIMBOUT SHORTLY AFTER AIRFOIL ANTI ICE TURNED ON, RIGHT ENGINE FAILED OR WENT TO IDLE POWER. RIGHT ENGINE STARTED TO PROVIDE NORMAL POWER AFTER 1 AND ONE HALF TO TWO MINUTES. RETURNED TO DEN AND LANDED WITHOUT INCIDENT. AIRCRAFT TSDR WX0400033Seal · leakingAFTER NORMAL TAKEOFF ROLL AT APPROXIMATELY 600 FT TO 800 FT AGL MASTER WARNING LIGHT ILLUMINATED, TRIGGERED BY TAIL COMPARTMENT TEMPERATURE HIGH LIGHT. CREW FOLLOWED QRH PROCEDURES AND RETURNED TO AIRPORT, NO EMERGENCY DECLARED AND AIRCRAFT LANDED WITHOUT INSDR GTIA040784Guide Vane · crackedFOUND LT ENGINE INLET GUIDE VANES CRACK FOUND ON 3 VANES AT 3 O'CLOCK POSITION. REMOVED AND REPLACED INLET CASE. (M)SDR P9RA20040040Power Supply · inoperativeEXTERIOR EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY POWER SUPPLY IAW MM.SDR WX0400031Battery · dischargedMAINTENANCE REPORTED AFT SERVICE DOOR AND AFT ENTRANCE DOOR EMERGENCY EXIT LIGHTED SIGNS INOPERATIVE, OVERHEAD EMERGENCY EXIT LIGHTS AFT FLIGHT ATTENDANT STATION, OVERHEAD EMERGENCY EXIT LIGHT ROW 2 AND OVERHEAD EMERGENCY EXIT LIGHTS ROWS 31 TO 33 INOPERATIVESDR WX0400030Connector · looseMAINTENANCE REPORTED SEAT EMERGENCY EXIT LIGHT AT ROW 20 INOPERATIVE. MAINTENANCE SECURED LOOSE CONNECTOR, EMERGENCY EXIT LIGHT OPERATES NORMALLY. AIRCRAFT RETURNED TO SERVICE.SDR WX0400024Battery · dischargedAFTER SCHEDULED LANDING, MAINTENANCE REPORTED EMERGENCY FLASHLIGHT AT L-1 DOOR CHARGE LIGHT DOES NOT BLINK. MAINTENANCE REMOVED AND REPLACED BATTERY IAW MM 25-00-00. OPERATIONALLY CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR MWEA040135Connector · looseSTANDBY LIGHT INOPERATIVE AT ROW 23, LT SIDE. SECURED LOOSE CONNECTION.SDR MWEA040136Connector · looseEMERGENCY LIGHT INOPERATIVE AT ROW 11 RT SIDE. SECURED LOOSE CONNECTION.SDR MWEA040132Fitting · corrodedCORROSION AT GALLEY 1 FORWARD ATTACH POINT JUST AFT OF WATER SUPPLY PAN FITTING AT STATION 160 AND RT OF THE BUTT LINE. FABRICATED AND INSTALLED FITTING.SDR MWEA040133Fitting · corrodedCORROSION AT G1 FORWARD ATTACH POINT JUST AFT OF POTABLE WATER SUPPLY FITTINGS AT FRAME STATION 200. FABRICATED AND INSTALLED FITTING.SDR MWEA040134Web · corrodedSUB FLOOR AT FRAME STATION 200 JUST AFT OF RT AFT GIRT BAR ATTACH FITTING, CORRODED. FABRICATED AND INSTALLED WEB.SDR ASMF200408007Ahrs · failedAIRCRAFT RETURNED TO PLATFORM, AHRU NR 1. AIRCRAFT WAS SENT TO THE HANGAR AND DURING CHECK WERE DETECTED RT RMI FLAGS. AHRU NR 1 WAS REPLACED AND DURING WORKS THE SAME FAILURE APPEARED ON RT SIDE. AHUR NR 2 AND FLUX VALVE WERE REPLACED IAW 34-21-10 AND 34-2SDR ASMF200408008Servo Valve · leakingDURING TRANSIT CHECK, HYDRAULIC LEAKAGE WAS DETECTED IN INTERIOR DOUBLE SERVO VALVE. IT WAS REPLACED IAW MM32-43-02, TEST WERE CORRECT.SDR CALA0400593Floor Support · corrodedINSPECTION FOUND CABIN FLOOR SUPPORT CORRODED AT STA 1155 BETWEEN LT IB AND LT MID SEAT TRACK. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-1 AND 51-30-5.SDR ASMF200408005Control Valve · damagedAIRCRAFT WAS SENT TO THE HANGAR TO ATTEND FLAPS DIFFERENCE INDICATIONS AND FLAPS DID NOT RETRACT COMPLETELY. FLAPS CONTROL VALVE AND INTERIOR FLAPS ACTUATORS WERE REPLACED IAW MM 27-50-01 AND 27-50-02, BUT FAIL CONTINUES. FLAPS CONTROL VALVE WAS REPLACED AGAINSDR MWEA040128Angle · crackedCABIN SIDE OF AFT PRESSURE BULKHEAD, A STIFFNER AT TWELVE O'CLOCK POSITION IS CRACKED ON OB END. FABRICATED AND INSTALLED ANGLE.SDR MWEA040129Fitting · gougedKEEL TO SLANT PRESSURE PANEL ATTACH BRACKETS IN THE LT WHEEL WELL HAS SEVERAL GOUGES. FABRICATED AND INSTALLED FITTINGS.SDR MWEA040130Doubler · corrodedMODERATE CORROSION ON LOWER FUSELAGE BETWEEN STA 769 TO STA 807 IN THE AREA OF RT LOWER WING TO FUSELAGE FILLET RUB STRIP AT LONGERON RT 29 AND RT 28. FABRICATED AND INSTALLED DOUBLER.SDR MWEA040131Bracket · corrodedFORWARD AND AFT BRACKETS FOR THE FLOOR SUPPORT BETWEEN STATION 148-200 RT OF FUSELAGE CENTER LINE ARE CORRODED. FABRICATED AND INSTALLED TWO EACH BRACKETS.SDR C8GA20040014Smoke Detector · defectiveFLT 707 FROM KPHX TO KMCI. DURING CRUISE, THE LOWER AFT CARGO FIRE WARNING CAME ON. FOLLOW ALL CCIA AOM ABNORMAL PROCEDURES, CONTACTED ATC AND DECLARED AN EMERGENCY. THE AIRCRAFT DIVERTED TO KGCK AND LANDED WITHOUT INCIDENT. UPON LANDING, THE AIRCRAFT WAS THENSDR DHL2004745540Airstair · damagedDURING A C-CHECK, REMOVE AFT AIRSTAIR INFLIGHT LOCK, FABRICATE AND INSTALL DOUBLER IAW SRM. REMOVED AFT AIRSTAIR INFLIGHT LOCK IAW SRM 51-30-2 FABRICATED DOUBLER FROM 2024-T3 .063 SIZE 9 .25 INCH X 4.75 INCH PO NR 900790 IAW SRM 53-30-3 TREATED AND PRIMED PARSDR ASMF200407035Lever · brokenAIRCRAFT RETURNED TO PLATFORM, FUEL LEVER UNLOCKED. DURING MAINTENANCE REVISION, SPRING LOCK LEVER WAS DETECTED BROKEN. AIRCRAFT WAS SENT TO THE HANGAR AND SPRING WAS REPLACED IAW MM 76-12-00, TEST CORRECT.SDR ASMF200407036Skin · damagedDURING TRANSIT CHECK WAS DETECTED APU DIVERTER FLUID AND FUSELAGE SKIN WITH DAMAGES. FINAL REPAIR WAS PERFORMED ON LT SIDE OF FUSELAGE SKIN IAW SRM 53-04 AT Y-1272 STATION, BETWEEN LT 23 AND 25 LONGERONS. DIVERTER FLUID WAS REPLACED IAW SRM 51-30-0 AND 51-10-4SDR ASMF200407032Proximity Sensor · dirtyAIRCRAFT RETURNED TO PLATFORM, (RUDDER TRAVEL UNRESTRICTED) LIGHT TURNED OFF BEFORE TAKE OFF AND LT GENERATOR INOPERATIVE. PSEU TEST WAS PERFORMED, ALL CORRECT; RUDDER LIMITER PROXIMITY SWITCH WAS CLEANED AND CHECKED, RUDDER WAS ACTUATED WITH HYDRAULIC PRESSURSDR P9RA20040023Proximity Switch · stickingIB FLIGHT, APPROXIMATELY 10 MINUTES BEFORE LANDING, TAIL CONE ANNUNCIATOR ILLUMINATED AND REMAINED ON. QRH PROCEDURE FOLLOWED. NO EMERGENCY DECLARED. UNEVENTFUL LANDING. FOUND DOOR PROXIMITY SWITCH STICKING. CLEANED AND LUBRICATED SWITCH.NO OTHER DEFECTS NOSDR DLM88040705Apu · failedAPU GEN KICKED OFF INFLIGHT WITH A/C XTIE LOCKOUT RESULTING IN RT A/C BUS UNPOWERED. REPLACED GCU.SDR ASMF200407030Slide · dislodgedDURING TRANSIT CHECK, CAPTAIN REPORTED THAT FOOD SERVICES COMPANY PERSONNEL FELL DOWN THROUGH LT SERVICE DOOR SLIDE. LT SERVICE DOOR SLIDE WAS REINSTALLED IAW MM 25-62-01. DURING OVERNIGHT SERVICE, LT SERVICE DOOR SLIDE INSTALLATION WAS CHECKED IAW MM 25-62-SDR ASMF200407024Indicator · failedCAPTAIN REPORTED THAT AT THE BEGINNING OF THE TAXI, APPEARED THE AIR SPEED A/S FLAG IN THE LT AIRSPEED INDICATOR. IT WAS PERFORMED A RESET AND THE CADC SWITCH WAS CHANGED OF POSITION, BUT THE TROUBLE CONTINUED. AIR SPEED INDICATOR WAS REPLACED AND SYSTEM TESTSDR DLM88040683Tire · damagedNR 2 MAIN TIRE LOST RECAP ON TAKEOFF. DAMAGE TO LT IB FLAP AND BUTE DOOR. ALSO DAMAGE TO LOWER LT ENGINE INLET COWL AT 6 O'CLOCK POSITION LOWER SIDE. NO DAMAGE TO ENGINE FAN BLADES. REPAIRED/REPLACED DAMAGED PARTS.SDR DL73S040677Skin · crackedFUSELAGE SKIN CRACKED AT STA 750 AND STR 18R ADJACENT TO AN EXISTING CHEM-MILL. AREA REPAIRED IAW ERA 092053-14.SDR MWEA040122Doubler · corrodedFORWARD SERVICE DOOR THRESHOLD SUBFLOOR AT FRAME STATION 168, CORRODED. FABRICATED AND INSTALLED DOUBLER.SDR ASMF200407022Valve · failedDURING FUELING IN TRANSIT CHECK, FILLED FUEL CENTRAL VALVE FAILED. VALVE, TOTALIZER AND FUEL QUANTITY INDICATOR WERE CHECKED IAW MM 28-40-02, ALL CORRECT. DURING TRANSIT CHECK AT MEX VALVE FAILED AGAIN AND IT WAS REPLACED IAW MM 28-20-02, TEST CORRECT.
Back to Pratt & Whitney JT8D series