What was found
AIRCRAFT RETURNED TO PLATFORM, (RUDDER TRAVEL UNRESTRICTED) LIGHT TURNED OFF BEFORE TAKE OFF AND LT GENERATOR INOPERATIVE. PSEU TEST WAS PERFORMED, ALL CORRECT; RUDDER LIMITER PROXIMITY SWITCH WAS CLEANED AND CHECKED, RUDDER WAS ACTUATED WITH HYDRAULIC PRESSURE AND FAIL CONTINUE. AIRCRAFT WAS SENT TO THE HANGAR AND DURING OVERNIGHT SERVICE, D1-33 AND D1-34 RUDDER SENSOR TAG WAS ADJUSTED IAW MM 27-20-00 AND TESTED IAW MM 27-20-06, ALL CORRECT.