Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011062003028Idg · faultyR GEN IS FAULTY. NO TIME ORD ** DL8334 CREATED TO MONITOR ** REPLACED R GCU, NO HELP, GCU FAULTS IDG-PMG. RE-INSTALLED ORIG GCU. REPLACE NR 2 IDG PER MM. LEAK CHECK AND OP CHECK OKAY.SDR UALA2011061702975Oxygen Bottle · missingOXYGEN BOTTLE MISSING - USED AT AFT CABIN. REPLACED O2 BOTTLE.SDR UALA2011062003014Control Panel · faultedFLT CREW REPORTING COMMUNICATION RADIO ISSUES ON BOTH CAPT AND FIRST OFFICER POSITION. MET AND DEBR IEF FLT CREW ON ARRIVAL. REPLACED F-O & OBS AUDIO SEL PANELS, OP CKS GOOD.SDR UALA2011062003015Feeder Cable · damagedSEAT ROW 20 TO 26 THE EMERGENCY LIGHTS ON LT AISLE SEAT END BAY INOP. FOUND DAMAGED EMERGENCY LIGHT CABLE AT SEAT ROW 25ABC, REPAIRED WIRE AS REQUIRED. OPS CHECKED OKAY.SDR UALA2011061702984Wire · shortedDOOR 1L SLIDE LIGHT WILL NOT ILLUMINATE WHEN SLIDE IS ARMED. TRIED ANOTHER LIGHT CAP NO HELP. COMPLIED WITH MEL CARD. VERIFIED LIGHT CAP WORKS AT OTHER LOCATION, FOUND WIRE SHORTED TO GROUND APPROX 2 OHMS, BETWEEN SPLICE SP50 AND W3582-A-PA, WITH OR WITHOUTSDR UALA2011061702985Module · failedFWD CARGO FIRE WILL NOT TEST. REPLACED SWITCH MODULE, TESTED OKAY.SDR UALA2011061702982Valve · unsecureUNWANTED FUEL TO CENTER FUEL TANK DURING FUELING. SECURED BOTH CENTER TANK FILL VALVES CLOSED AND CHECKED OKAY.SDR UALA2011061702983Indicator · reads lowCREW REPORTS COCKPIT O2 PRESS READS 7 0PSI. SERVICED CREW O2 SYSTEM PER MM. CHECKED SYSTEM FOR LEAKS AND FOUND NONE.SDR UALA2011061602963Attach Fitting · looseSLIDE LIGHT DOOR 3R INOPERATIVE. FOUND FLOOR FITTING ATTACH SCREWS NOT SCREWED DOWN ALL THE WAY PREVENTING DOOR FROM ARMING. SECURED SCREWS. DOOR ARMING OPERATION NORMAL.SDR UALA2011061602964Cowling · delaminatedNR 2 ENG OUTBOARD FAN COWL HAS DELAMINATION ON INSIDE FWD EDGE 20" BY 42". REPLACED WITH SERVICEABLE COWLING. BOTTOM LATCHES ARE SECURE.SDR UALA2011061502947Gcu · malfunctionedEICAS MESSAGE RIGHT IDG TEMP SENSOR DISPLAYED AFTER PARKING AIRCRAFT FROM REPOSITIONING. BIT BPCU, MESSAGE IDG-OIL OUT BULB-WIRING, REPLACED RIGHT GCU. REPLACED RT IDG PER MM. RAN ENG, OPS CHECK GOOD.SDR UALA2011061402938Gcu · faultyRIGHT GENERATOR CONTROL CYCLING ON AND OFF AFTER LANDING. SERVICED IDG NR 2 OIL AND REPLACED GCU NR 2 PER AMM. GENERATOR NR 2 CHECKED OKAY ON 5 MIN IDLE RUN.SDR UALA2011061502956Collar · lack of lubeNOSE GEAR STEERING USING FOOT PEDDLES PRODUCES APPROX 1 DEGREE LEFT WITH FULL LEFT INPUT AND APPROXIMATELY 8 DEGREES RT WITH FULL INPUT. INSPECTED NLG, NO DEFECTS NOTED. FOUND STEERING COLLAR WITH INSUFFICIENT LUBRICATION. ACCOMPLISHED GEAR LUBE AND RIG CHESDR UALA2011061302896Packing · damagedL HYD QTY EICAS. FLUID DROPPED TO .46RF. SECURED L ENG & ELEC PUMPS. LEAK STOPPED. PRESSURIZED LT SYSTEM. FOUND SPRAYING LEAK AT LT ELECTRIC PUMP. REPLACED PACKING AT OUTLET PRESSURE LINE FITTING. REPRESSURIZED SYSTEM - FOUND NO FURTHER LEAKAGE. SERVICSDR UALA2011061302906Slide · obstructedTHE 3R SLIDE DOES NOT SHOW ARMED WHEN ARMED. REMOVED LOOSE DEBRIES. SLIDE ARM AND DISARM OPERATION CHECKS OKAY.SDR UALA2011061302907Seat · looseSEAT ASSY LOOSE 32ABC, 37DEF, 39ABC, 39DEF, 40DEF. SECURED SEAT ASSY IAW AMM.SDR UALA2011061302899Cap · dislodgedEND CAP CAME OFF EMERGENCY EXIT PATH LIGHTS BY FWD CLOSET. REPLACED END CAP, FLOOR LIGHTS CHECKED NORMAL.SDR UALA2011061402927Chiller · faultyCREW REPORTS FLIGHT ATTENDANT IN FORWARD GALLEY SMELLED AN ACRID ODOR. CREW TURNED OFF THE LIGHTS FOR THE FORWARD GALLEY AND THE SMELL DISSIPATED. DEBRIEFED CABIN CREW UPON ARRIVAL TURNED OFF GALLEY LIGHTS AND CHILLER SMELL DISSIPATED. FOUND WATER IN CHILLESDR UALA2011061402929Floorbeam · corrodedCORROSION AT FLOORBEAM STA 365 AT RBL 38. MAJOR REPAIR ACCOMPLISHED: CORROSION WAS BEYOND SRM LIMITS & THE UPPER CHORD OF THE FLOORBEAM REQUIRED REPLACEMENT PER THE INSTRUCTIONS ON PEMCO EA PD57-53-137 WITHOUT DEVIATION. THIS IS CONSIDERED A PERMANENT REPAISDR UALA2011061302882Wire · brokenAFTER T-S FOUND BROKEN WIRE IN FWD EE PANEL P-32. WIRE IS MARKED AA AND W1132. IT LOOKS LIKE IT IS GOING ON THE RT UTIL BUS CB AT TOP OF P-32 PANEL. BROKEN WIRE REPAIR ON PTT 8322002 SECURED RT UTILITY BUS CB ON P32 PANEL REF 24-51-24.SDR UALA2011061302887Unknown · malfunctionedL ENG BLEED LIGHT NOT ON WITH ENGINE SHUT DOWN. REPLACED PRSOV PER MM. JUMPED PINS ON CONNECTOR-STILL NO LIGHT WITH BLEED OFF. RAN ENGINE PER JRH AND FOUND DUCT PRESSURE TO READ ABOVE 15 PSI WHEN OPEN AND ZERO WHEN CLOSED.SDR UALA2011061302889Filter · faultyF/A REPORTED AIRFLOW IN CABIN EXTREMELY LOUD FROM OVERHEAD DUCTING. AIRFLOW SUFFICIENT THROUGHOUT A-C BUT STRONGER AND NOISIER IN SEVERAL AREAS. SUGGEST A-C MAY NEED ENTIRE A-C DUCT CLEANING TO EQUALIZE AIRFLOW THROUGHOUT CABIN. NOISE IS FROM RISERS ON BOTHSDR UALA2011061302891Unknown · vibrationVERY HEAVY VIBRATION ON FLAP RETRACTION AT FLAPS 1 COMING THROUGH HANDLE.SDR UALA2011061302892Seat · looseSEAT ASSY LOOSE IN THE TRACKS 10ABC, 11ABC , 20ABC, 24ABC, 26ABC, 26DEF, 27ABC, 30ABC, 34ABC, 35ABC, 36ABC, 37ABC, 38ABC, 39ABC. SECURED SEATS IN TRACKS IAW AMM.SDR UALA2011061302924Controller · faultyRIGHT PACK WENT FULL COLD PLACED SELECTOR IN STBY NORMAL. BITE SHOWS CONTROLLER FAULT. REPLACED RT CONTROLLER. OPS CHECK OKAY.SDR UALA2011061302925Control Valve · faultyRT PACK TRIPPED OFF ON FINAL. REPLACED FCV, OPS CHECKS OK.SDR UALA2011061302894Stringer · corrodedCORROSION ON STRINGER 29R AT STA 1420. MAJOR REPAIR. REMOVED CORRODED STRINGER AND FOUND OUT OF LIMITS. FABRICATED REPLACEMENT STRINGER, ACCOMPLISHED HFCF INSP AND FOUND CRACK FREE. INSTALLED STRINGER AND SPLICE REPAIR IAW SRM. TREATED & PRIMED IAW AMM SDR UALA2011061302895Bear Strap · corrodedAFT CARGO BEAR STRAP BETWEEN BS 1400 AND BS 1420 RBL 23 HAS CORROSION. MAJOR REPAIR. REPAIRED BEAR STRAP AT AFT CARGO PER PD 57-53-140 AND EVA 80920.SDR UALA2011061302898Skin · damagedFUSELAGE SKIN HAS LIGHTNING STRIKES AT BS 249, STR 16-17L. MAJOR REPAIR ACCOMPLISHED: BLENDED AREA AND FOUND TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGE AND FABRICATED A REPAIR FILLER & DOUBLER AND INSTALLED PER REO G13718, REV C ON NON ROUTINE 40068. PER SDR UALA2011061302901Controller · faultyON APU START, GOT A FAULT LIGHT. CONTROLLER SHOWING FUEL SOLENOID FAULT. SOLENOID MAY HAVE TO BE ROBBED FROM FCU OR FROM APU SHOP. REPLACED APU FUEL CONTROL UNIT PER MM.SDR UALA2011061302890Actuator · faultyRECEIVED AN APU SHUTOFF VALVE MESSAGE. RECONNECTED CONNECTOR TO ACTUATOR & PERFORMED MULTIPLE OPS CHECKS.SDR UALA2011061302881Bearing · out of positionUNABLE TO CLOSE DOOR 2L. LOWER GATE CONTACTS THRESHOLD. EXCESSIVE FORCE REQUIRED TO CLOSE AND AND LOCK DOOR 2L. FOUND LOWER HINGE BEARING MIGRATED. REPLACED BEARING AND INSTALLED DOOR. INSTALLED GUIDE ARM AND ADJUSTED DOOR.SDR UALA2011061302884Acm · malfunctionedHEAVY VIBRATION AND NOISE IN CRUISE FL 410 WITH RT PACK STANDBY NORMAL AND LT PACK RETURNED TO AUTO. LT ACM WAS REPLACED. RIGHT PACK PUTS OUT VERY LOW AIR FLOW. WILL NOT HOLD CABIN PRESSURE WITH LT PACK OFF. FOUND RT PACK BAY FLEX CONNECTOR PARTIALY DISCONNSDR UALA2011061302917Circuit Card · faultyLEFT ENG STARTER WILL NOT HOLD IN GND. LT START HOLD-CUTOUT START SYSTEM INOP. MANUAL HOLD PROCEDURES APPLY. INSTALLED NEW LEFT ENGINE SPEED CARD M10298 PER MM. ACCOMPLISHED LT ENG START AFTER SPEED CARD REPLACEMENT. START HOLD FUNCTION CHECK TESTED GOOD.SDR UALA2011061302879Floorbeam · corrodedCORROSION AT CABIN FLOOR SUPPORT SHEAR TIE STA 1681.8, BL 0 - RBL 40. MAJOR REPAIR. REPAIRED AFT DECK WEB AT STATION 1680 - 1690 RBL 27-53 IAW EA PD 57-53-134.SDR UALA2011061402926Hinge · brokenGROUND POWER ACCESS PANEL, ONE HINGE IS BROKEN. DOOR REMOVED AND PLACED IN THE LOB. DOOR REMOVED AND PARTS PLACED IN COCKPIT. INF- :HINGE PCN 170-0975 SEE IPC 52-49-01-001 ITEM #260. INF- :HINGE 170-0975 PLACED ON OSTF X2511. *OPBLMOH* CDL REF: 52L (PARTSDR UALA2011061502948Hinge · brokenGROUND POWER ACCESS PANEL, ONE HINGE IS BROKEN. DOOR REMOVED AND PLACED IN THE LOB. DOOR REMOVED AND PARTS PLACED IN COCKPIT.SDR UALA2011061302915Wire · brokenCREW REPORTED SMOKE IN CABIN. FA DESCRIBED ELECRICAL ODOR IN 1ST CLASS ON DESCENT. NO DEFINITE LOCATION. NO ODORS NOTED IN COCKPIT OR COACH, OR FWD GALLEY. EMERGENCY PROCEDURES CLEARED HAZY SMOKE AT 10,000'. IN P32 PANEL FOUND 0058 WIRE C1 LUG BROKEN OFF AT SDR UALA2011061002856Flex Hose · out of positionLOUD NOSE & MAIN GEAR NOISE. STARTED AT 17500 290 KTS. CONSTANT AIRFRAME VIBRATION NOISE. NOISE WENT AWAY WHEN THROTTLE PULLED BACK, IT WAS LIKE A MOTOR GOING ON AND OFF. AIRCRAFT WILL NOT HOLD PRESSURE WITH ONLY LEFT PACK ON. RIGHT PACK HOLDS PRESSURE SDR UALA2011061302918Slide · unserviceableDOOR NR 2 LEFT SLIDE PRESSURE IS IN RED BAND. REPLACED DOOR 2L EMERGENCY ESCAPE SLIDE. SLIDE ARMS & DISARMS NORMAL, REMOVED SLIDE & BOTTLE PINS, VERIFIED BY SUPERVISOR & INSPECTOR.SDR UALA2011061302868Crease Beam · corrodedCORROSION AROUND FASTENER ON CREASE BEAM AT RT STA 1050. COMPLETED REPAIR IAW EA PD 57-53-129.SDR UALA2011061302869Angle · crackedEXTERNAL FUSELAGE ANGLE AT BS 1180 COMMON TO BODY FAIRING FRAME AT LBL 11 HAS A 1 INCH CRACK IN ANGLE RADIUS. MAJOR REPAIR ACCOMPLISHED OF FUSELAGE FAIRING SUPPORT ANGLE AT BS 1180 BETWEEN STRINGER 27L & 29L IAW EA PD57-53-138 AND EVA 80917 WITHOUT DEVIATION.SDR UALA2011060902839Light · inoperativeNOSE GEAR UNSAFE LIGHT INOP AT TEST SWITCH. REPLACED LAMP 1665, OPS GOOD.SDR UALA2011060902845Module · faultyGEAR DISAGREE LIGHT ILLUM. DEBRIEFED CREW AND NOTED GEAR AMBER LIGHT ILLUMINATED WITH ASSOCIATED GEAR DISAGREE EICAS MSG. THIS HAPPENS 3X DURING GEAR CYCLES ON FINAL AND GO-AROUND. PSEU SHOWS FAULTS 421,422 ,423,424. FIM SHOWS REPLACE LANDING GEAR LEVER ASSDR UALA2011060802824Life Vest · missingLIFE VEST MISSING FROM 10C, 11E, 14C AND 18A. INSTALLED VESTS.SDR UALA2011060902852Pilot Valve · faultyUNABLE TO COOL AC ON GROUND WITH ENGINE BLEEDS ONLY ON IDLE. R 8 PSI, L 15 PSI. AC NORMAL IN FLT. PER MEL REPLACED HI STAGE PILOT PER AMM.SDR UALA2011060902836Pushrod · out of adjustMAIN CABIN L-4 DOOR MODE SELECTOR LEVER FAILS MIDWAY CHECK. ADJUSTED MAIN CABIN DOOR L -4 MODE SELECTOR LEVER GIRT BAR CRANK PUSH RODS PER MM. DOOR MIDWAY CHECK IS GOOD PER MM ON NON ROUTINE 39871.SDR UALA2011060802830Terminal Block · looseWITH NO OTHER INDICATIONS NOTED SMELLED AN ACRID ODOR TWO TIMES WITHIN 10 MINUTES. THERE WAS NO REPEAT, NO SMOKE OR OTHER INDICATIONS ANYWHERE IN THE COCKPIT OR CABIN. CALLED DD AND MM. REPORTED ODOR WAS COMING FROM GLARESHIELD AREA. MM ACCOMPLISHED VISUAL OSDR UALA2011060902837Cam · faultyMAIN CABIN R-4 DOOR MODE SELECTOR LEVER FAILS MIDWAY CHECK. REMOVED AND REPLACED R-4 DOOR LOCKOUT CAM AND ADJUSTED LOCK OUT CAM MECHANISM PER MM AND OPS CHECK GOOD. ADJUSTED R-4 DOOR CRANK PUSH RODS PER MM ON NON ROUTINE 39872.SDR UALA2011060902853Fan · inoperativeWEATHER RADAR FAILED ON PRE FLIGHT. REPLACED WEATHER RADAR TRANSCEIVER. OPS CHECKED GOOD. BITE TEST FAILURE MESSAGE WAS "RT". NOTED SEVERAL RECENT HISTORIES WITH TRANSCEIVER AND CONTROL PANEL REPLACED. TRANSCEIVER BOX WAS VERY WARM. SUSPECT COOLING FAN I
Back to Pratt & Whitney PW2037