Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011053102631Floorbeam · corrodedFLOORBEAM STA 1640 RBL 41 TO RBL 52 HAS SIGNS OF CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION FROM FLOORBEAM BETWEEN RBL41-52 & FOUND OUT OF LIMITS. FABRICATED & INSTALLED T-CHORD SECTION, ANGLES & REPAIR PARTS AMT & INSP'D.SDR UALA2011053102624Wire · brokenFWD FLOOR EMERGENCY LIGHT STRIP AT COAT CLOSET INOP. REPAIRED BROKEN WIRE TAPE.SDR FDEA201105282019Firewall · gougedAPU COMPARTMENT, FWD FIREWALL HAS GOUGES, 8" FROM BOTTOM EDGE OF WALL. FOUND GOUGE TO BE .003" DEEP, DETERMINED TO BE OUT OF LIMIT IAW SRM 53-80-01, FIG 101 DET IX PG 109, REPAIRED DAMAGE PER SRM 53-80-08, FIG 201, SHEET 1 PG 201. MAJOR REPAIR.SDR UALA2011053102614Computer · failedRIGHT EICAS COMPUTER FAILED. CYCLED J29 TO RESTORE AND EICAS RETURNED, FAILED AGAIN MINUTES LATER. REPLACE EICAS COMPUTER. ASSURE EQUIP COOLING AIRFLOW TO COMPUTER AND THAT COOLING METERING PLATES NOT CLOGGED. REPLACED RT EICAS COMPUTER PER MM, OPS CHKS GOSDR UALA2011053102615Computer · faultyLEFT EICAS COMPUTER FAILED. INOP'D AND PLACARDED PER MEL. REPLACED LT EICAS COMPUTER PER MM. ALSO, REPLACED SWITCHING MODULE M10417 PER MM, OPS CHKS GOOD.SDR UALA2011052702604Shaft · out of toleranceDOOR 4R EXTERNAL HANDLE DOES NOT RETRACT OR STOW. REMOVED R-4 DOOR EXTERNAL HANDLE AND REPLACED CENTER SHAFT, YOKE, BEARING, CLUTCH COLLAR AND REGREASED PER MM. OPS CHECK GOOD ON NON ROUTINE 29063.SDR UALA2011052702605Mechanism · out of adjustDOOR 4R FAILS MIDWAY CHECK. ADJUSTED MAIN CABIN R-4 DOOR MODE SELECT LOCKOUT MECHANISM PER MM. OPS CHECK GOOD ON NON ROUTINE 29062.SDR UALA2011052702592Floorbeam · corrodedFWD GALLEY FLOORBOARDS POPPING UP DUE TO FLOORBEAM CORROSION AT STA 324. MANUFACTURED AND INSTALLED FLOORBEAM REPAIR PER UA-EVA-80904.SDR UALA2011052702588Angle · corrodedCORROSION ON FWD PIT ANGLE ASSY 143N5368-939 DETERMINED TO BE LEVEL 2 CORROSION. REPAIRED ANGLE.SDR UALA2011052702596Inlet · delaminatedNR 1 ENG INBOARD FAN COWL HAS A LARGE AREA OF DELAMINATION LOWER FWD CORNER. FOUND ONE LAYER OF DELAMINATED FIBERGLASS INSTALLED OVER ALUMINUM FOIL REPAIR. ALUMINUM FOIL DELAMINATED FROM COWL APPROX 27" X 18". DELAM BEYOND LIMITS. WILL REQUIRE REPAIR PER SSDR UALA2011052602576Lamp · inoperativeSEAT 24 EMERGENCY LIGHT INOPERATIVE, PER A-CHECK. REPLACED EMERGENCY LIGHT LAMP, CHECKED OKAY.SDR UALA2011052602577Lamp · inoperativeSEAT 26 EMERGENCY LIGHT INOPERATIVE, PER A-CHECK. REPLACED LAMP ASSEMBLY, OPS CHECK OKAY.SDR UALA2011052702598Light · unsecureEMERGENCY LIGHTING FLOOR STRIP AT ROW 13ABC IS COMING UP. RE-SECURED STRIP COVER TO FLOOR CHANNEL, LIGHT OPS GOOD. ROW 13 IS BULKHEAD FEED TO STRIP CAUSING SLIGHT RISE IN CARPET. NO DEFECTS NOTED. OK PER SMF MM.SDR UALA2011052702599Piston · out of adjustMAIN CABIN L-4 DOOR RED BAND ON POWER SPRING CYLINDER PISTON NOT VISIBLE. ADJUSTED L-4 DOOR SPRING CYLINDER PISTON PER MM ON NON ROUTINE 29335.SDR UALA2011052702600Hinge · wornR-1 DOOR CUTOUT UPPER HINGE BEARING WORN OUT. REMOVED UPPER HINGE LINK AND REPLACED HINGE LINK BEARING WITH NEW AND RE-INSTALLED HINGE LINK PER MM AND GN-MM 1-0-1-097.SDR UALA2011052702597Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CHORD, BS 1660, LBL 9.5 - LBL 26. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION ON FLOORBEAM PER SRM. REMAINING MATERIAL FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA ON UPPER CHORD SAT 1660 LBL 12- LBL-27, NDT AND HFEC AREA ASDR UALA2011052702595Controller · faultyFLT DECK WARMER THAN SELECTED WITH SWITCH ON & TEMP CONTROL IN AUTO. INOP LIGHT EXISTING. PRESS ECS REC BUTTON AND RECORD ZONE TEMPS. PROG TEXT: ACCOMPLISH CHRONIC REVIEW. -CHRONIC. PROCEDURE 1 USED ON MEL 2161E. REPLACED ZONE TEMP CONTROLLER. CHECKS OSDR UALA2011052502560Bottle · unserviceableMAIN CABIN, R-4 DOOR EMERGENCY POWER BOTTLE DATE OF MANUFACTURE NOT VISIBLE, HYDROSTATIC TEST DATE EXPIRED AS NOTED ON ROUTINE JIC 5R52I8050. REPLACED R-4 DOOR EMERGENCY POWER RESERVOIR BOTTLE PER MM ON NON ROUTINE 29382.SDR UALA2011052502565Regulator · out of adjustDOOR 2L SLIDE RAFT SAFETY PIN WILL NOT GO ALL THE WAY IN. ADJUSTED MAIN CABIN L-2 DOOR SLIDE REGULATOR ASSY PER MM ON NON ROUTINE 29039 .SDR UALA2011052502566Door · out of adjustDOOR 2R FAILS MIDWAY CHECK. ADJUSTED MAIN CABIN R-2 DOOR MODE SELECT LOCKOUT MECHANISM PER MM AND DOOR OPS CHECKED GOOD ON NON-ROUTINE 29061.SDR UALA2011052502567Valve · out of adjustDOOR 4R EMERGENCY ESCAPE SLIDE SAFETY PIN CANNOT BE INSERTED INTO THE INFLATION CYLINDER VALVE. ADJUSTED MAIN CABIN DOOR R -4 ESCAPE SLIDE VALVE ASSY PER MM ON NON ROUTINE 29134.SDR UALA2011052602581Nut Plate · damagedDAMAGED NUT PLATE ON RT ELEVATOR PCU ACCESS PANEL 345DB FWD OTBD SIDE. ONE NUT PLATE ON BLADE PANEL AFT OF PANEL 345DB. DAMAGED NUT PLATES REPLACED AND PANELS REINSTALLED.SDR UALA2011052502548Rivet · damagedLT FUSE AT STA 680 STR 25L HAS RIVET DAMAGED BY LIGHTNING STRIKE. MAJOR REPAIR ACCOMPLISHED: REMOVED RIVET AND INSTALLED CHERRYMAX RIVET PER MM. NEEDS TO BE RE-INSPECTED AT C CHECK AND REPLACED AT HMV. ** MF7573 CREATED TO MONITOR ** MAJOR REPAIR OF FUSESDR UALA2011052502554Floorbeam · corrodedCORROSION ON FLOORBEAM TOP STA 1640 RBL 23-58. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED PORTION OF T-CHORD AT STA 1640 LBL 9 TO RBL 67 IAW SRM. FABRICATED REPAIR ANGLES AND STRAPS IAW SRM 53-00-51 REPAIR NR 3. INSTALLED NEW T-CHORD P/N BAC1505-100880 PER SDR UALA2011052502555Floorbeam · corrodedCORROSION ON FLOORBEAM TOP STA 661 RBL 57. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL FOUND TO BE OUT OF LIMITS IAW B757 SRM. FABRICATED NEW T-CHORD PER SRM, TREATED AND PRIMED NEW CHORD, STRAPS AND ANGLES IAW 757 AMM. INSTALLED ALL ANGLE AND STRAPSDR UALA2011052502556Floorbeam · corrodedCORROSION UNDER FLOORBEAM AROUND SCREW HOLE STA 377 LBL 50. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED FLOORBEAM FROM STA 377 LBL 37 TO LBL 64 PER SRM, FABRICATED REPAIR FLOOR BEAM AND ANGLES PER SRM, LOCATED AND DRILLED NEW REPAIR FLOORBEAM IAW SRM. INSTALSDR UALA2011052502549Antenna · damagedNR 1 VHF -UPPER- ANTENNA LEADING EDGE HAS ALL FINISH ERODES AND A CRACK FROM SIDE TO SIDE OPEN IN LEADING EDGE ABOUT .5 INCH ABOVE VENT HOLE. REPLACED ANTENNA USING GEL GASKET.SDR UALA2011052702594Link · out of toleranceNR 7 FLAP TRACK AFT FAIRING ATTACH POINT BEARINGS TO LINK ROD AND LINKAGE HAVE EXCESSIVE AXIAL PLAY - BEARINGS HAVE FAILED. REPLACED ADJUSTMENT LINK AND INSTALLED WASHER IN SUPPORT LINK.SDR FDEA201105241960Floorbeam · gougedFLOORBEAM AT STA 1600 HAS NUMEROUS GOUGES BETWEEN RBL 60 TO LBL 60. REMOVED AND REPLACED FLOORBEAM, FOUND TO BE OUT OF LIMITS PER SRM 53-00-51 FIG.101 DETAIL 3. LOCATED AND DRILLED FASTENER HOLES IN NEW FLOORBEAM PER SRM 51-40-02. APPLIED TOP COAT PER SRM 51SDR UALA2011052402537Slide · defectiveDOOR 1R SLIDE LIGHT DOES NOT ILLUMINATE. SAMC TEXT: GIRT BAR UNATTACHED AND DROPPED AND DAMAGED WHEN DOOR CLOSED. REPLACED SLIDE.SDR UALA2011052302517Light · looseEMERGENCY LIGHT STRIP LOOSE BY FWD F/A JUMPSEAT. SECURED, CHECKED OPERATION.SDR UALA2011052302530Nose Cowl · damagedNR 1 ENGINE CONTACTED LOADING BRIDGE ON ARRIVAL TO GATE. REPLACED NOSE COWL.SDR UALA2011052502544Slide · malfunctionedDOOR 1R SLIDE LIGHT DOES NOT ILLUMINATE. GIRT BAR UNATTACHED AND DROPPED AND DAMAGED WHEN DOOR CLOSED. REPLACED SLIDE PER MM.SDR UALA2011052302512Valve · faultyNO LAND 3 ON BOTH AUTOLAND STATUS INDICATORS. MAINT TEXT: MCDP LAST LEG FAULT WAS "ILS CP-ILS L" AND "AIL SER VO-FCC L". MCDP TEST 7 INTERMITTANTLY FAILS "AIL SRVO R". SOME MCDP HISTORY FOR THIS FAULT SEVERAL LEGS AGO. DUE TO FAULTS ON BOTH SIDES A-C WAS SDR UALA2011052302503Bearing · splitMAIN ENTRY DOOR 1 RT BODY TORQUE TUBE BEARING, LOWER HINGE BRG SPLIT IN TWO IN CAM PLATE. INSTALLED NEW BRG IN CAM PLATE AND INSTALLED LWR TORQUE TUBE ASSY.SDR UALA2011052302506Pressure Switch · faultyABORTED T/O AT 110 KNOTS DUE TO RT ENG OIL PRSR IND. R ENG OIL PRESS LIGHT AND EICAS ILLUMINATED ON TAKEOFF. REPLACED SWITCH PER MM. ACCOMPLISH LEAK AND OP CHECK OF NR 2 ENG LOW OIL PRESS WARNING SWITCH. ACP RUN UP TEST FAILED FOR LOW OIL PRESSURE LIGHT WOSDR UALA2011052302526Wire · burnedDOOR2L SLIDE ARM LIGHT NOT ILLUMINATING WHEN DOOR IS ARMED. ON COMPLETION OF LM8651, FOUND BURNT WIRES ON FWD GIRT BAR PROXIMITY SWITCH. REPAIRED WIRE WITH ENVIRONMENT SPLICE. OPS CHECK SLIDE LIGHT GOOD.SDR UALA2011052302508Oxygen Mask · damagedCAPTS O2 MASK "NORM"-"COMF" LEVER BROKE OFF. REPLACED CAPTS O2 MASK.SDR UALA2011052002484Controller · inoperativeFLT DECK TEMP CONTROLLER INOP. TEMP VARIED BTWN 92 AND 61. CREW REPORTED STBY SYSTEM WORKED WHEN SWITCHED OVER. REPLACED LEFT PACK TEMP CONTROLLER PER AMM, OPS CHECK NORMAL.SDR UALA2011052002485Shutoff Valve · faultyLOUD WHISTLING NOISE WRT RECIRC OR BOTH PACKS ON. AIR NOISE TOO LOUD INTERF W COCKPIT COM. COMPLIED WITH MEL. CK SOUND & AIRFLOW LEVELS AT START & END TO COMPARE IMPROVEMENT. SUGGEST ACP STEP-4 OF ABOVE SVC TIP. IF NO FAULTS FOUND SUGGEST REPLACE LT PACK SDR UALA2011052002495Link · lack of lubeDOOR 1L HARD TO DISARM AND ARM. FOUND ARMING LEVER IMPOSSIBLE TO FREELY MOVE. REMOVED DOOR LINERS PER AMM. INSPECTED DOOR ARMING LINKAGE AND CABLES, NO DEFECTS FOUND. LUBRICATED ALL ROD ENDS AND MOVEABLE LINKS FOR ARMING SYSTEM, AFTER WORKING, MOVEMENT NORSDR UALA2011051902475Floorbeam · crackedSTA 700 FLOORBEAM CRACKED. REPAIRED PER UA EVA 80851 ACP ON SMB W-U F5524P.SDR UALA2011052002488Mechanism · lack of lubeDOOR 3R DIFFICULT TO ARM AND DISARM. SUPPLEMENTAL DATA UPDATE REMOVED LINER AND LUBED ARMING MECHANISMS. OPS OKAY.SDR UALA2011051802470Cam · out of adjustL-1 DOOR, MUST PUSH ARM LEVER VERY HARD TO GET DOOR SLIDE LIGHT TO COME ON. ADJUSTED L-1 DOOR LIFTER CAM BRACKETS PER MM AND DOOR OPS CHECK GOOD ON NON ROUTINE 47544.SDR UALA2011051802471Slide · misinstalledMAIN CABIN DOOR 2R EMERGENCY SLIDE NOT IN MOUNTS PROPERLY. REMOVED AND RE-INSTALLED R-2 DOOR SLIDE CORRECTLY PER MM ON NON ROUTINE 47013.SDR UALA2011051802447Cap · crackedDOOR 1L THRESHOLD REVEAL INSTL. CAP HAS 2.5 IN CRACK ON OTBD EDGE. REMOVED REVEAL CAP. R&R TO SHOP FOR WELDING. REINSTALLED CAP WET WITH SEALANT.SDR UALA2011051802442Selector Panel · faultyCOMM ON SERVICE INTERPHONE. NOISY & INOPERATIVE FROM AUDIO SELECTOR PANEL. NORMAL FROM OTHER CREW POSNS. LOUD BACKGROUND NOISE-BUZZ, CONTINUOUS IN ALL SELECTIONS. REPLACED NR 2 AUDIO SELECTOR PANEL, TESTED OKAY.SDR UALA2011051802448Slide · misinstalledMAIN CABIN DOOR 1L DOOR SLIDE NOT IN MOUNTS PROPERLY. REINSTALLED SLIDE CORRECTLY PER MM.SDR UALA2011051802449Lever · out of adjustL-2 DOOR ARM AND DISARM LEVER IS BINDING. ADJUSTED L-2 DOOR ARM AND DISARM LEVER PER MM AND OPS CHECK GOOD ON NON ROUTINE.SDR UALA2011051802450Rod End · lack of lubeMAIN CABIN DOOR 45R SLIDE ARM HANDLE STIFF TO OPERATE. LUBED DOOR ROD ENDS AND BEARING PER MM.
Back to Pratt & Whitney PW2037