As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOORBEAM UPPER CHORD, BS 1660, LBL 9.5 - LBL 26. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION ON FLOORBEAM PER SRM. REMAINING MATERIAL FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA ON UPPER CHORD SAT 1660 LBL 12- LBL-27, NDT AND HFEC AREA AND FOUND IT TO BE CRACK FREE. FABRICATED DRILLED AND INSTALLED IAW SRM.