Pratt & Whitney PW2037
Service difficulty reports · 12,809
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013122393904Door Seal · tornFWD CARGO DOOR PRESSURIZATION SEAL TORN, AT LOWER AFT RADIUS. REPAIRED DOOR SEAL.SDR CALA2013122393905Socket · dirtyLT ENG OVERHEAT LIGHT FAILS TO ILLUMINATE WHEN DOING FIRE TEST, ADD LIGHT TEST. CLEANED LIGHT SOCKET, TESTED OK.SDR CALA2013122693912Unknown · malfunctionedIN UNDER 2 HR FUEL IN LT TANK UP BY 1500 LBS. IAW FUEL IMBALANCE, FUEL EVEN USING CTR PUMPS. 1:50 AFTER TANK TO ENG LT TANK 1500 LBS ABOVE RT. LT ENG BURN 100 PPH MORE THAN RT ENG IAW SEQ 4502010, 4502009, 4502007 & 4502002. COMPLETED FUEL TRANSFERS WAS UNASDR CALA2013122093849Controller · faultyLT ENG BLEED AIR SURGES AT LOW POWER SETTINGS, WILL NOT OPEN ENG ANTI ICE AT IDLE. DUCT PRESS. REPLACED NR 1 ENG HIGH STAGE PILOT CONTROL. RAN ENG, OPERATED NORMAL. OPERATIONS CHECK OF ENG ANTI ICE VLV CHECKED GOOD.SDR CALA2013122393859Skin · crackedDOOR 4R INNER SKIN CRACKED ADJACENT TO PULL ASSIST HANDLE. CUTOUT DAMAGE, HFEC VERIFIED DAMAGE, REMOVED IAW NDT PT 6, 51-00-19, NO DAMAGE NOTED. FABRICATED INNER SKIN DOUBLER & INSTALLED IAW ECRA 5200-01267. THIS IS A PERMANENT REPAIR.SDR CALA2013122393860Floorbeam · crackedMAIN CABIN FLOOR BEAM HAS A CRACK 1.5 INCHES LONG AT RADIUS OF THE UPPER CORD STATION 700, LBL 45.50. CUTOUT DAMAGE & INSTALLED REPAIR IAW ECRA5300-01807 NR 33108.SDR CALA2013122393861Door Frame · damagedDOOR 2L CUTOUT FRAME FLANGE STATION 690 HAS FOUR EACH HOLES ON INNER FLANGE, LOCATED NEAR UPPER LOCKING CAM. CUTOUT DAMAGED FASTENER HOLES & INSTALLED REPAIR DOUBLER & SPLICE PARTS IAW ECRA 5300-01 803.SDR CALA2013122393871Warning System · false activationTE FLAP DISAGREE EICAS ILLUMINATED WHEN FLAP LEVER MOVED FROM 20 TO 25 FLAPS. TROUBLE SHOT IAW FIM 27-51 PG 135 & FOUND A RT FLAP TRANSMITTER WIRE FAULT ON THE 2 FSCU. SWAPPED THE 2 & 3 FSCU. PERFORMED BITE TEST & HAVE NO MORE FAULTS. DID CHECK THE CP ON TSDR CALA2013122393873Connector · defectiveAUTO SPEED BRAKE DID NOT DEPLOY ON LANDING. REPLACED S10697 & CONNECTOR RT GEAR TILT SWITCH IAW WDM 27-62-01. AUTO SPEED BRAKE OPERATIONS CHECKED GOOD.SDR CALA2013122393874Apu · flamed outEVIDENCE OF FLAME & SMOKE COMING FROM APU TAILPIPE. SUSPECT APU TURBINE SEALS BLOWN & WILL REQUIRE APU REPLACEMENT. IAW DF151, APU FIRE SYS DEACTIVATED. DO NOT OPERATE APU UNTIL FIRE SYS RESTORED. APU SMOKE, FLT CREW ELECTED TO DISCHARGE APU FIRE BOTTLE PRSDR CALA2013121993816Wire · brokenR4 DOOR SLIDE INDICATION IS WEAK. CLEANED CONTACTS, NO HELP. TRIED ANOTHER LED LENS CAP, NO HELP. NEED LIGHT ASSEMBLY PCN 561-2342. REPAIR IAW WDM 25-66-11, FOUND WIRE 3682-E-PA BROKEN OFF NEAR SPLICE AT PROXI SW S10224. REPAIRED WITH ENVIRONMENTAL SPLICESDR CALA2013122093832Seat Track · brokenRT INBD SEAT TRACK HAS A BROKEN LUG. INSTALLED NEW SEAT TRACK SECTION & REPAIR ANGLES & STRAP REPAIR STATION 1180 - 1250, RBL 24 IAW SRM 53-00-52, FIG 201, NR 34227.SDR CALA2013122093833Bleed Valve · malfunctionedAPU BLEED VLV CYCLES CLOSED UNCOMMANDED.SDR CALA2013122093851Regulator · faultyLOW LT ENG DUCT PRESS AT THROTTLE UP, RT DUCT PRESS NORMAL. LT BLEED & LT PACK EICAS MESSAGES. REPLACED BOTH HIGH STAGE PILOT & PRSOV REGULATOR IAW MM 36-11-08, MM 36-11-19 ON LT ENG. RAN ENG BOTH DUCT PRESS NORMAL NO BLEED OFF LIGHT ILLUMINATED. NO EICAS SDR CALA2013122093853Switch · faultyCAPTAIN`S VHF RADIO HAS A STUCK MIC. REPLACED CAPTAIN`S CONTROL COLUMN PUSH TO TALK SWITCH IAW WDM, OPERATIONS CHECKED GOOD AT THIS TIME.SDR CALA2013122093854Light · inoperativeDOOR 2L SLIDE ARM LT INOPERATIVE, AFTER PUSH BACK. RELAMPED & OPERATIONS NOW NORMAL.SDR CALA2013122393870Switch · defectivePREFLIGHT CHECK OF CTR FUEL PUMPS FAILED. CTR PUMP LIGHTS DO NOT ILLUMINATE AFTER 10 SEC. TROUBLE SHOT IAW WDM 28-21-11. R & R S346 FUEL PANEL DOOR OPEN SWITCH. FUEL PUMPS OPERATION IS NORMAL IAW AMM 28-22-00.SDR CALA2013121993791Stringer Splice · corrodedCORROSION ON STRINGER SPLICE STATION 1465, STRINGER 28R. R & R STRINGER 28R SPLICE AT STATION 1465 IAW SRM 51-40-02, FIG 2, 3, 8, & 12 PN 146N3820, N-R 230031.SDR CALA2013121993803Door · frozenAPU WILL NOT START. OPENED INLET DOOR MANUALLY VIA MANUAL DRIVE IAW AMM 49-15-06. FOUND ICE & SNOW STUCK IN INLET ACTUATOR AREA. APU INLET DOOR FROZEN ICED SHUT. RAN APU & MELTED COMPARTMENT. CYCLED APU SEVERAL TIMES, OPERATIONS NORMAL.SDR CALA2013121893766Structure · damagedFUSELAGE HAS APPROXIMATELY 1" X 3-4" DENT APPROXIMATELY 1 - 2" BELOW DOUBLER REPAIR & 28" AFT OF DOOR 2 LT. DENT WITHIN LIMITS OF SRM 52-00-01 AREA HAS BEEN NDT NO CRACKS FOUND. MEASURE DENT A=.80, Y=.054 A-Y=18.5, OUT OF LIMITS IAW SRM 53-00-01,FIG101, DETSDR CALA2013121893767Floorbeam · corrodedCORROSION AT MAIN CABIN FLOOR BEAM BS 377 LBL 60. CORROSION AT MAIN CABIN FLOOR BEAM BS 377, LBL 60 IS OUT OF LIMITS IAW SRM 53-00-51, FIG101 DETAIL VI. REPAIRED FLOOR BEAM IAW ECRA 5310-05536, REPAIR 3.SDR CALA2013121893779Trim System · malfunctionedON CLIMB OUT RUDDER TRIM STUCK AT 1.0 LT & WOULDN'T TRIM FURTHER. FREED UP AFTER RT INPUT. RUDDER TRIM ON GND IS INOPERATIVE, NO MOVEMENT.SDR CALA2013122093852Actuator · stuckON CLIMB OUT RUDDER TRIM STUCK AT 1.0 LEFT & WOULDN'T TRIM. FREED UP AFTER RT INPUT. RUDDER TRIM ON GND IS INOPERATIVE, NO MOVEMENT. REPLACED RUDDER TRIM ACTUATOR & UPPER ARM ASSEMBLY.SDR CALA2013121893778Guard · out of adjustEMERGENCY EXIT LIGHTS COME ON IN THE OFF POSITION. CREW REPORTS WHEN EMERGENCY LIGHTS SWITCH IS TURNED OFF, EMERGENCY LIGHTS ILLUMINATE. FOUND AFT ATTENDANT PANEL SWITCH GUARD FOR EMERGENCY LIGHT BLOCKING SWITCH FROM PUSHING COMPLETELY OUT. ADJUSTED AFT ATTESDR CALA2013121693737Guide Arm · out of adjustIAW LM 7835, DURING OPERATIONAL CHECK OF DOOR 1L, FOUND UPPER HINGE COVER OUT OF SEQUENCE & CONTACTING DOOR HINGE DURING OPERATION. LARGE CLUNKING NOISE AS DOOR IS CLOSED APPROXIMATELY MIDPOINT OF DOOR SWING. ADJUSTED GUIDE ARM IAW AM M 52-11-04.SDR CALA2013121693740Floorbeam · corrodedMAIN CABIN FLOOR BEAM BS 1660 BL 0 TO BL 21 HAS CORROSION. CORROSION OUT OF LIMITS IAW SRM 53-00-51 FIG 101. REPAIRED IAW ECRA 5310-05563 FIG 202 REPAIR 2.SDR CALA2013121693741Floorbeam · corrodedMAIN CABIN FLOOR BEAM HAS CORROSION AT BS 1640 RBL 52 TO RBL 60. CORROSION OUT OF LIMITS IAW SRM 53-00-51 FIG 101. REPAIRED IAW SRM 53-00-51 REPAIR 8 FIG 201.SDR CALA2013121693742Floorbeam · corrodedCORROSION ON MAIN CABIN FLOOR BEAM AT BS 365 FROM B L0 TO RBL 60. CORROSION OUT OF LIMITS IAW SRM 53-00-51 FIG 101. REPAIRED FLOOR BEAM IAW ECRA 5310-05536 REPAIR 3.SDR CALA2013121693753Actuator · leakingHYD LEAK LT OTBD WING NEAR AIL. REPLACED LT INBD PCA ACTUATOR.SDR CALA2013121693754Cover · damagedEMERGENCY FLOOR TRACK LIGHT COVER AT ROW 28 - 30 DAMAGED. INSTALLED EMERGENCY LIGHT COVER CLEAR LENS AT ROW 29, OK FOR SERVICE.SDR CALA2013121693735Mechanism · obstructedDOOR 1L WILL NOT ARM WITH DOOR CLOSED. REMOVED DEBRIS FROM ARMING MECHANISM, OPERATIONS CHECKED GOOD.SDR CALA2013122793991Seat · unsecureSEATS 22DEF NOT SECURED TO FLOOR. SECURED SEATS IAW MM.SDR CALA2013122093836Duct · contaminatedCABIN BECAME HAZY SHORTLY AFTER TURNING APU BLEED ON & RT PACK ON. ACCOMPLISHED PACK BURNOUT IAW PG 204 THROUGH V AFTER CLEANOUT OF REHEATER & PACK DUCTS OF DEICING FLUID. NO ODOR OR HAZE IN CABIN AFTER 15 MIN RUNS WITH BOTH BLEEDS & PACKS.SDR CALA2013122793990Wire · faultyEICAS MESSAGE, MACH SPD TRIM, DISPLAYED & MACH SPD LIGHT ILLUMINATED. FOR AIRCRAFT N501UA-N522UA DO 27-09-00 FIG106C AIRCRAFT N523UA-N594UA DO 27-09-00 FIG 106. CREW COMMENTS ILLUMINATED AFTER USE OF ALTERNATE STAB TRIM LEVERS, ITEM ROLLED FWD. WHEN ACTIVATSDR CALA2013121393681Lock · failedCOCKPIT DOOR LOCK FAILED. HAD PREVIOUS HIT. AUTOMATIC LOCKING SYS INOPERATIVE.SDR CALA2013121793764Oven · contaminatedCREW REPORTED SMOKE IN THE MID GALLEY OVEN AREA. FOUND HEATING ELEMENT CONTAMINATED BY GRAVY.SDR CALA2013120993577Frame · damagedFWD CARGO DOOR HAS FIVE DENTS & GOUGES ON FRAME. INSTALLED NEW FRAME IAW SRM 51-40-02.SDR CALA2013120993547Bottle · failedTEST 2 LT EMERGENCY ESCAPE SLIDE SQUIB FAILED TO TEST. REPLACED K10486, NO HELP. REPLACED OVERWING BOTTLE IAW MM.SDR CALA2013120993571Heater · inoperativeWHILE ACCOMPLISHING SMOKE FUME CHECK MM 05-51-56. FOUND DOOR AREA HEATER FOR DOOR 4 LT & RT NOT WORKING.SDR CALA2013120993545Light · detachedEMERGENCY LIGHT STRIP 9ABC NEEDS RE ATTACHED. SECURED EMERGENCY EXIT LIGHT STRIP.SDR CALA2013120993546Blade · crackedNR 2 ENG, CRACK INDICATED DURING HFEC INSPECTION ON SEVEN EACH BLADES' LE. REPAIRED IAW MM 72-31-02, OKAYED FOR SERVICE.SDR CALA2013120993552Seal · brokenLT AILERON RT SIDE HAS BROKEN GAP SEAL. PLACED ON CF IAW ECRA 573-01528.SDR CALA2013121393654Unknown · odorSMELL IN AFT GALLEY, FLT DIVERTED.SDR CALA2013120593480Door Seal · loose1R PRESS LEAK NOISE SECURED, CLEANED & LUBED DOOR 1R SEAL. VISUALLY INSP DOOR 1R EXTERIOR, ALL NORMAL.SDR CALA2013121993818Bleed Air Sys · malfunctionedAPU SOV INOPERATIVE. APU BLEED STOPPED WORKING NOT SURE OF SOURCE OR BLEED LEAK. PERFORMED APU PERFORMANCE CHECK, NO FAULT FOUND & PERFORMANCE CHECKED NORMAL IAW DIS 245.SDR CALA2013120493455Filter · defectiveAPU BLEED AIR SURGES. REPLACED APU SURGE VLV ELEMENT FILTER IAW AMM, OPERATIONS CHECKED NORMAL.SDR CALA2013121193591Kit · missingFLIGHT ATTENDANT CANNOT LOCATE ONBOARD SECURITY KIT. SECURITY KIT MISSING DF2520 FT. REPLACED SECURITY KIT.SDR CALA2013120293350Frame · dentedBS 1480 FRAME IN AFT CARGO COMPARTMENT IS DENTED NEAR STRINGER 26L. REPAIRED FRAME IAW SRM 53-00-07 FIG 201 REPAIR 5.SDR CALA2013120293351Contact · dirty2L WILL NOT ARM, ARM LIGHT INOPERATIVE. CLEANED ARM LIGHT CONTACTS & CYCLED ARMING LEVER SEVERAL TIMES. ARM LIGHT CHECKED GOOD. FOUND NO OTHER DEFECTS.SDR CALA2013121193589Vsi · inoperativeLIGHT ON FIRST OFFICER`S VSI OUT. REPLACED FIRST OFFICER`S VSI INDICATOR IAW MM, CHECKED GOOD.
Back to Pratt & Whitney PW2037