What was found
MAIN CABIN FLOOR BEAM HAS A CRACK 1.5 INCHES LONG AT RADIUS OF THE UPPER CORD STATION 700, LBL 45.50. CUTOUT DAMAGE & INSTALLED REPAIR IAW ECRA5300-01807 NR 33108.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR BEAM HAS A CRACK 1.5 INCHES LONG AT RADIUS OF THE UPPER CORD STATION 700, LBL 45.50. CUTOUT DAMAGE & INSTALLED REPAIR IAW ECRA5300-01807 NR 33108.