Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010093003625Shutoff Valve · faultyRT ENG BLEED AIR VALVE 'OFF' LIGHT NOT ON WITH SWITCH 'ON' & ENG RUNNING. DUCT PRESS WAS NORMAL. REPLACED PRSOV AND PRSOV REG IAW MM. CHECKS GOOD ON ENGINE RUN.SDR DALA1023935502Skin · crackedDURING RT ENGINE CHANGE FOUND CRACK IN PYLON SKIN AT 2 O’ CLOCK POSITION NEXT TO FASTENER LIGHTNING HOLE. REPAIRED IAW ERA 485603-14, SEC I, SEC II REQUIRES PERMANENT REPAIR WITHIN 24 MONTHS OR 3000 CYCLES AFTER SECTION I ACCOMPLISHMENT.SDR DALA1024840613Wire · damagedDURING A SERVICE CHECK, MX FOUND THE LT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD.SDR UALA2010092803581Tube · rupturedREFUELING PROBLEM. FOUND TEE TUBE FWD OF LT REFUELING VALVE IN REFUELING MANIFOLD RUPTURED AT TEE JUNCTION. PN 344N2017-10 ON AOG N5628. TUBE REMOVED FROM TANK. REPLACED FUEL MANIFOLD IAW MM.SDR UALA2010092703566Cover · looseEMERGENCY EXIT PATH LIGHTS ROWS 30-34 ARE LOOSE. REPLACED EMERGENCY LIGHT TRACK COVER.SDR UALA2010092703563Light · inoperativeEMERGENCY LIGHT AT SEAT 18 AND 19 INOPERATIVE. REPLACED EMERGENCY LIGHT STRIPS, OPS OKAY.SDR UALA2010092703564Light · inoperativeSECTION OF EMERGENCY LIGHTING INOP AT AFT LAV. INSTALLED SERVICEABLE EMEGENCY LIGHT STRIP.SDR UALA2010092703567Wire · shortedCREW REPORTS LT AFT GALLEY CART PIGTAIL NR62 WAS ARCING. CREW PULLED CBS FOR CART CONTROLLERS M61, M62 , M63 PRECAUTIONARY. WIRES DAMAGED, CB PULLED AND COLLARD FOR CART 62 CONTROLLER M62. REPLACED PIGTAIL, OPS CK OK.SDR UALA2010092703574Module · faultyNO DUCT PRESSURE FROM APU. LOW AIR PRESSURE FROM APU. APU PRESSURE RETURNED TO NORMAL. REOPENED BY ORD MM FOR: LOW BLEED PRESSURE PROBLEM RETURNED. REPLACED APU AIR FLOW SENSOR MODULE. APU DUCT PRESSURE CONSTANT NOW AT 28 PSI. OPERATES BOTH PACKS AND DRY MOTSDR UALA2010092403550Oxygen Mask · damagedCAPT AND OBS SMOKE MASK STRETCHED OUT. REPLACED BOTH MASKS.SDR FDEA201009223634Skin · dentedPREVIOUS SKIN DENTED AT BS 309, S18L. ACCOMPLISHED SKIN REPAIR IAW EA F-5330-141203, BS 309, BELOW S17L. DENT WAS OUT OF LIMITS DUE TO PROXIMITY TO BS 310.5 FRAME. 2EA. SHEAR TIES WERE FABRICATED ON TRAVELERS T10/855076 AND T10/855075. MAJOR REPAIR.SDR UALA2010092203518Hinge · damaged13ABC BIN INOP. NO EMERGENCY EQUIPMENT INSIDE. REPLACED RT HINGE.SDR UALA2010092103516Connector · burnedCONNECTOR TO ADI HAS BURNED PINS. REPLACED CAPT. EADI CONNECTOR D87. INSTALLED NEW LEFT EADI AND RESET CB. FINAL OPS CHECK SATISFACTORY.SDR UALA2010092003479Skin · dentedDENT IN FUSE 5, FRAMES FWD OF DOOR 2L, 2 STRINGERS BELOW SKIN LAP. DENT APPROX 8 IN LONG, 4 IN WIDE, 3-8 IN DEEP AND EXTENDS INTO EXISTING DOUBLER. MAJOR REPAIR ACCOMPLISHED: INSTALLED REPAIR DOUBLER, STRUCTURAL FILLER AND TRIPLER.SDR UALA2010092003498Controller · malfunctionedRIGHT BLEED VALVE DID NOT CLOSE WITH SWITCH. ONLY CLOSED WHEN ISOLATION VALVE IS OPEN AND LT BLEED OPEN, DEFERRED. REPLACED RT ENG BLEED REVERSE FLOW CHECK CONTROL ASSY. OPS CHECKED GOOD, NO FAULTS.SDR UALA2010092003482Isolation Valve · faultyDUE TO REPORTS OF ISOLATION VALVE WOULD NOT OPEN (POPPED CB). REPLACED VALVE REF AMM, OPS CHECKS OK. CONNECTOR INSP AND PIN RETENTION CHECK OK, REMOVED RELAYS AND OVERHEAD PANEL AND MEGGERED WIRING, NO FAULTS FOUND.SDR UALA2010092003497Battery · overheatedSMELL OF SMOKE IN CABIN. FOUND SOURCE OF SMELL AND SMOKE AS APU BATTERY VERY HOT AND ODOR THE SAME AS WHAT WAS IN CABIN AREA JUST ABOVE THE E6 RACK. REPLACED APU BATTERY AND APU CHARGER PRECAUTIONARY. ALSO, REPLACED K116 RELAY PRECAUTIONARY. OPS CHECK NORMSDR UALA2010092103510Connector · burnedRIGHT ENGINE SEC CONTROL, RT ENG REVERSER CONTROL AND RT ENG LIMIT PROTECTION EICAS & LIGHT CAME ON. FOUND CONNECTOR OR RT ENG PMA WITH BURNED PINS. REPLACED PMA. RAN ENGINE AT IDLE FOR 5 MIN, ENG OPERATES OK.SDR DALA1023115636Battery Pack · inoperativeDURING LINE CHECK, MX FOUND THE EMERGENCY EXIT SIGNS AT DOORS 3L, 3R, AND THE AFT GALLEY INOPERATIVE. MX REPLACED THE POWER SUPPLY AND BATTERY PACK. OPS CHECK WAS GOOD.SDR UALA2010091603467Isolation Valve · faultyISOLATION VALVE WILL NOT CLOSE. FOUND VALVE NOT FULLY FUNCTIONAL. REPLACED ISOLATION VALVE, OPS CHECKS OK.SDR DALA1023460675Skin · dented09-15-10 ON ARRIVAL, DENTS FOUND AFT OF DOUBLER REPAIR AT L-2 2 INCHES OUTSIDE REPAIR, INSTALLED REPAIR DOUBLER. REPAIR IAW ERA 485677-14, REV 0.SDR UALA2010091403422Start Valve · failedNUMBER 1 ENGINE FAILED TO START, NO N2 ROTATION WITH START VALVE LIGHT ILLUMINATED. REPLACED NR 1 ENG STARTER CONTROL VALVE. OPS AND LEAK CHECK GOOD.SDR UALA2010091303400Lamp · burned outEMERGENCY LIGHT AT DOOR 4 RT IS OUT. RELAMPED, OPS CHECK OK.SDR UALA2010091403420Skin · dentedSKIN DENT AT STA 1681, STR 29L. MAJOR REPAIR ACCOMP. IAW EVA 80086 AND EA PD57-53-051 ON NR 228Z0046 AND 228Z0099.SDR UALA2010091303384Audio Panel · faultyNR 2 VHF RADIO BLEEDS OVER TO NR 1 VHF RADIO FLT IN PH. RADIO IS MALFUNCTIONING. REPLACED F-O AUDIO SELECT PANEL. OPS GOOD.SDR UALA2010091303397Gate · crackedMAIN ENTRY DOOR 1 RT UPPER GATE IS CRACKED IN 2 LOCATIONS. REPLACED GATE ASSY.SDR FDEA201009113344Skin · misrepairedRT APU DOOR EXISTING FLUSH REPAIR AT BS 1957, STR 29R DOES NOT COMPLY WITH KNOWN APPROVED DATA. REMOVED EXISTING REPAIR IAW SRM 51-40-02. REPAIRED APU DOOR SKIN, RT, IAW SRM 52-40-01, FIG 201, P205, REPAIR NR 5. CAT "A" MAJOR REPAIR, NO REPETITIVE INSP REQUISDR DALA1022265522Skin · dentedDURING M-CHECK FOUND DENT AND SCRATCH ON FUSELAGE SKIN AT BS 620 S16L. REPAIRED IAW ERA 484243-14.SDR FDEA201009083310Floorbeam · corrodedMAIN DECK FLOORBEAM UPPER TEE CORRODED FROM BL 0 TO LBL 24.5 STA 345. REMOVED CORROSION IAW SRM 51-10-02. CHECKED LIMITS ORIGINAL THICKNESS .125" AFTER REMOVED .106" FOUND OUT OF LIMITS IAW 53-00-51, FIG 101, DET III REMOVED FLOORBEAM AT STA 345 BET, LBL 70 SDR FDEA201009083317Fitting · misalignedAT STA 1640 LT THE 657N3161-11 FITTING HAS 2EA EXISTING SED FASTENERS AT LWR, INBD, END OF FITTING ALSO 5EA, EXISTING FASTENERS WHERE DWG SHOWS 4EA, AT LWR END OF FITTING APPROX WL 202 TO WL 208 AND JUST INBD OF THAT LOCATION 5EA EXISTING FASTENERS AT INBD, EDSDR UALA2010090803334Terminal Block · looseFOUND TERMINAL BLOCK J1 LOOSE AT CAPT'S NR1 WINDOW. NEED TO REPLACE NR1 CAPT'S WINDOW. REMOVED WINDOW. REMOVED WINDOW. INSTALLED NEW CAPT'S NR 1 WINDOW, WINDOW HEAT OPS OK, COMPLETED 2ND TORQUE & SEALED, SEALANT CURED, REMOVED TAPE & REPOSITIONED WIPER BACSDR DALA1021715636Battery Pack · inoperativeDURING LAYOVER CHECK, MX FOUND THE SEAT 26-30 EMERGENCY PATH LIGHTS, PLUS ROW 29 EMERGENCY EXIT LIGHT INOPERATIVE. MX REPLACED BATTERY PACK M10699. OPS CHECK WAS GOOD.SDR FDEA201009073309Fitting · corrodedR1 DOOR FWD LOWER TORQUE TUBE ROLLER FITTING HAS PITTING CORROSION. R & R FWD LOWER TORQUE TUBE CAM ROLLER FITTING IAW CMM 52-11-05. MAJOR REPAIR.SDR UALA2010090703300Bottle · lowDOOR 2 RT DOOR ASSIST BOTTLE READING ZERO. REPLACED EMERGENCY POWER RESERVOIR.SDR UALA2010090803322Drain · cloggedFWD GALLEY SINK DRAIN LEAKING BEHIND GALLEY. GALLEY HAS TO BE REMOVED TO ACCESS LEAK. DRAIN SYS MADE INOPERATIVE. FWD GALLEY AND FWD LAV DRAIN CLOGGED, WATER BACK-UP, OVERFLOW BEHIND AND UNDER CHILLER. NO LEAKS NOTED. FOUND BAD SECTION OF HOSE IN E&E COMPT SDR DALA1021335522Gate · gougedDURING M-CHECK FOUND GOUGE ON BOTTOM FWD CORNER OF DOOR 4R GATE. REPAIRED IAW SRM 51-70-16 & SRM 52-11-38-401-926A.SDR UALA2010090703301Connector · damagedWINDSHIELD 1L TERMINAL J5 IS DAMAGED. SUPPLEMENTAL DATA UPDATE J5 TERMINAL BLOCKS FOUND NR 1 LEFT WINDOW J5 CONNECTOR CROSS THREADED. REMOVED NR 1L WINDSHIELD. NEW WINDOW IS IN, FIRST TORQUE ACP. REPLACED L1 CONNECTOR J5. INSTALLED NR 1L WINDSHIELD, WINDOW HESDR UALA2010090703308Guard · faultyCOCKPIT EMERGENCY EXIT LIGHT WILL NOT ARM WITH SWITCH CLOSED. REPLACED GUARD.SDR DALA1021846712Slide · partial deployDOOR 4L OPENED PARTIALLY WHILE ARMED. SLIDE DID NOT FULLY DEPLOY AND DOOR DID NOT FULLY OPEN DUE TO SURVIVAL KIT LANYARD TANGLED IN GIRT BAR. REPLACED 4L DOOR SLIDE AND INFLATOR BOTTLE.SDR UALA2010090703286Circuit Card · faultyCREW REPORTS LT ENGINE FIRE LP 2 STATUS MESSAGE DISPLAYED. ACCOMPLISHED FIM 26-11-00. LT ENGINE FIRE TEST CHECKS OK. IAW CREW MESSAGE WENT AWAY DURING FLIGHT. FOUND NO ACTIVE MSGS. REPLACED M682 LOOP 2 LT FIRE DET CARD AND OP-CHECK SATISFACTORY IAW MM AS PSDR UALA2010090703294Extinguisher · leakingAFT WATER FIRE EXT LEAKING. REPLACED FIRE EXTINGUISHER AFT GALLEY AREA.SDR UALA2010090703297Feeder Cable · failedEMERGENCY EXIT STRIP AROUND 13A HAS BEEN PULLED OUT UNABLE TO RESET BACK INTO HOLDER. EMERGENCY LIGHT STRIP INOP BETWEEN ROW 9 AND 13, CABLE ASSY CONNECTOR PINS BROKEN. ACCOMPLISHED WALK AROUND AND NO DISCREPANCIES FOUND. ALSO FOR WORK ACCOMPLISHED ON EMERGSDR UALA2010090703306Circuit Card · failedAPU BLEED VALVE CLOSES EARLY (31 PERCENT N2) DURING ENG START ON THE RT ENG LT ENG START NORMAL REPLACED RT ECS BLEED CONF CARD IAW WD. ACCOMPLISHED ENGINE START. OP CHECKED OK.SDR UALA2010090703293Link · displacedMAIN ENTRY DOOR 4 LT LOWER BODY TORQUE TUBE BEARING, LOWER LINK OUT OF SERPENTINE PLATE, IN 2 PIECES. R & R LOWER CAM PLATE REINSTALLED BOTH PLATES AND LWR LINK. REMAINING WORK COVERED BY ADDITIONAL SMC ITEMS.SDR DALA1021325522Sill · corrodedDURING M-CHECK FOUND CORROSION ON AFT CARGO LOWER DOOR SILL, UPPER CHORD FASTENER HOLES BETWEEN BS 1380 & BS 1440. REPAIRED IAW SRM 51-40-02, SRM 51-40-05.SDR DALA1022080673Wire Harness · brokenSEAT-MOUNTED EMERGENCY ESCAPE LIGHT AT 3CD WILL NOT ILLUMINATE. FOUND BROKEN WIRE HARNESS UNDER SEAT AND REPLACED THE HARNESS. OPS CHECK NORMAL.SDR DALA1025060617Frame · dentedDENT ON FRAME FLANGE STA 1300 RT STR 26. REPAIRED IAW ERA 485376-14 REV ORIG.SDR UALA2010090703289Bearing · migrated2 LT ENTRY DOOR BODY TORQUE TUBE LOWER SERPENTINE PLATE BEARING MIGRATED UP OUT OF PLATE. RESEATED BEARING ASSY.SDR UALA2010090703291Fitting · failedLT INBD AFT AFT FLAP DRIVE TORQUE TUBE ATTACH FITTING ON LWR SURFACE BEARING RETENTION FAILED, BEARING MIGRATED BUT TRAPPED INSIDE TUBE LUGS AND FITTING. R & R FITTING ASSY.SDR UALA2010090703285Shutoff Valve · failedFUEL LEAKING FROM CTR TANK REAR SPAR AT APU SHUTOFF ACTUATOR. REMOVED COUPLINGS TO APU FUEL SHUTOFF INSIDE FUEL TANK. REMOVED ACTUATOR ON THE OUTSIDE AND SHUTOFF VALVE AND SEAL FROM INSIDE TANK. REPLACED APU SHUTOFF VALVE AND REINSTALLED APU SHUTOFF VALVE
Back to Pratt & Whitney PW2037